Laserfiche WebLink
DRAWING LEGEND <br />NNN I XXX ROOM NUMBER / ROOM NAME <br />&\ SPECIFIC NOTE <br />OX WINDOW TYPE <br />A LOUVER TYPE <br />-_<N> WALL TYPE <br />NNN DOOR NUMBER <br />X N DOOR TYPE / FRAME TYPE <br />N ELEVATION NUMBER <br />AN.N LOCATION SHEET <br />N <br />A N SECTION NUMBER <br />LOCATION SHEET <br />N DETAIL NUMBER <br />AN.N LOCATION SHEET <br />n'-n'I n.n" ARCHITECTURAL (CIVIL) ELEV <br />T/O CONC LOCATION <br />ABBREVIATIONS <br />A/C AIR CONDITIONING <br />AFF ABOVE FINISHED FLOOR <br />ALUM ALUMINUM <br />8/0 BOTTOM OF <br />B/W BETWEEN <br />CIVIL CIVIL ENGINEERING DRAWINGS & SPECIFICATIONS <br />CLG CEILING <br />CL CENTER LINE <br />CT CEILING TILE <br />CONC CONCRETE <br />CMU CONCRETE MASONRY UNIT <br />CONT CONTINUOUS <br />CJ CONTROL JOINT <br />DR DOOR <br />EJ EXPANSION JOINT <br />ELEC ELECTRICAL DRAWINGS AND SPECIFICATIONS <br />ELEV ELEVATION <br />EW EACH WAY <br />EWC ELECTRIC WATER COOLER <br />EQ EQUAL <br />EXIST EXISTING <br />EXT EXTERIOR <br />FACP FIRE ALARM CONTROL PANEL <br />FEX FIRE EXTINGUISHER <br />FEC FIRE EXTINGUISHER CABINET <br />FD FLOOR DRAIN <br />FIN FINISH <br />FL FLOOR <br />GA GAUGE <br />GALV GALVANIZED <br />GC GENERAL CONTRACTOR <br />GYP BD GYPSUM BOARD <br />HC HANDICAPPED <br />HM HOLLOW METAL <br />HOR HORIZONTAL <br />HSS HOLLOW (TUBE) STRUCTURAL STEEL <br />ISA INTERNATIONAL SYMBOL OF ACCESSIBILITY <br />LAV LAVATORY <br />MAX MAXIMUM <br />MECH MECHANICAL DRAWINGS & SPECIFICATIONS <br />MO MASONRY OPENING <br />MTL METAL <br />MIN MINIMUM <br />MTD MOUNTED <br />NIC NOT IN CONTRACT <br />NO NUMBER <br />NOA MIAMI-DADE NOTICE OF ACCEPTANCE <br />NOM NOMINAL <br />NTS NOT TO SCALE <br />O/C ON CENTER <br />OH OPPOSITE HAND <br />PC PAINTED CONCRETE <br />PGB PAINTED GYPSUM BOARD <br />PLAM PLASTIC LAMINATE <br />PL PLATE <br />PLUMB PLUMBING DRAWINGS AND SPECIFICATIONS <br />PREFAB PREFABRICATED <br />PREFIN PREFINISHED <br />PT PRESSURE TREATED (WOOD) <br />REIN REINFORCED <br />SIM SIMILAR <br />SPECS TECHNICAL SPECIFICATIONS MANUAL <br />SS STAINLESS STEEL <br />STRUCT STRUCTURAL DRAWINGS AND SPECIFICATIONS <br />SAP SUSPENDED ACOUSTICAL PANEL (CEILING) <br />THK THICK <br />THR THRESHOLD <br />T&B TOP AND BOTTOM <br />T/O TOP OF <br />TYP TYPICAL <br />LION UNLESS OTHERWISE NOTED <br />VCT VINYL COMPOSITION TILE <br />VIF VERIFY IN FIELD <br />VERT VERTICAL <br />WC WATER CLOSET <br />WD WOOD <br />WWF WELDED WIRE FABRIC <br />W/ WITH <br />XTR EXISTING TO REMAIN <br />GENERAL PROTECT NOTES <br />1. EXISTING ITEMS AND CONDITIONS ARE DEPICTED AND DESCRIBED ON THESE <br />DRAWINGS ACCORDING TO INFORMATION OBTAINED FROM THE BEST AVAILABLE <br />DOCUMENTS AND SURVEYS. THE ARCHITECT PROVIDES NO ASSURANCE AS TO, <br />AND ASSUMES NO RESPONSIBILITY FOR THE ACCURACY OF THESE DEPICTIONS <br />AND DESCRIPTIONS. FIELD VERIFY AND DETERMINE BY ANT MEANS NECESSARY, <br />THE ACTUAL LOCATION AND CONDITION OF ALL PERTINENT ITEMS, INCLUDING <br />THOSE THAT MAY BE IN CONCEALED LOCATIONS. IF IT IS DISCOVERED THAT THE <br />ACTUAL CONDITIONS DIFFER FROM WHAT IS SHOWN IN THESE DRAWINGS OF IF <br />THE CONDITIONS THAT ARE TO REMAIN AS PART OF THE FINISHED WORK ARE <br />UNSUITABLE TO SUPPORT OR ACCOMMODATE THE PROPOSED WORK, OR DO NOT <br />MEET CODE REQUIREMENTS OR CONSTRUCTION INDUSTRY STANDARDS, <br />IMMEDIATELY NOTIFY THE ARCHITECT VIA A "REQUEST FOR INFORMATION" (RFI) <br />DOCUMENT AND DO NOT PROCEED WITH THE WORK UNTIL RECEIPT OF A <br />RESPONSE FROM THE ARCHITECT. <br />2. THE CONTRACT DOCUMENTS INCLUDE THESE DRAWINGS AND SPECIFICATIONS. <br />IF THE DRAWINGS AND THE MANUAL DIFFER IN THE DESCRIPTIONS OF ITEMS <br />OR FEATURES, IMMEDIATELY NOTIFY THE ARCHITECT VIA A "REQUEST FOR <br />INFORMATION" (RFI) DOCUMENT AND DO NOT PROCEED WITH THE WORK UNTIL <br />RECEIPT OF A RESPONSE FROM THE ARCHITECT. <br />3. ESTABLISH, WITH THE OWNER, AREAS AND LIMITS OF CONSTRUCTION ACTIVITY <br />INCLUDING: ACCESS WAYS, MATERIALS & EQUIPMENT STORAGE AREAS, FIELD <br />OFFICE SPACE, CONSTRUCTION PERSONNEL TOILET FACILITIES AND PARKING, <br />PROVIDE SIGNS, BARRIERS, AND TEMPORARY ILLUMINATION AS NECESSARY TO <br />SUFFICIENTLY PROTECT AND SEPARATE THE OWNER'S EMPLOYEES, PATRONS, <br />VISITORS, AND THE GENERAL PUBLIC FROM THE WORK RELATED ACTIVITIES. <br />4. CAREFULLY REMOVE ONLY THOSE MATERIALS, ASSEMBLIES, FIXTURES, DEVICES, <br />AND COMPONENTS NECESSARY TO ACCOMMODATE THE ALTERATIONS AND <br />ADDITIONS. PROVIDE TEMPORARY STRUCTURAL ASSEMBLIES WHERE REQUIRED <br />TO STABILIZE AND SUPPORT THE REMAINING CONSTRUCTION, PROVIDE <br />SUFFICIENT PROTECTION TO PREVENT UNNECESSARY DAMAGE TO THE <br />REMAINING CONSTRUCTION, FINISHES AND FACILITIES. REPAIR OR REPLACE ANY <br />EXISTING ITEMS AND FINISHED DAMAGED BY WORK RELATED ACTIVITIES AT NO <br />COST TO THE OWNER. WHERE REMOVALS OCCUR, PROVIDE CLEAN, UNIFORM <br />BREAKS AND CUTS AT THE REMAINING MATERIALS. FILL AND PATCH WITH NEW <br />MATERIALS AND ASSEMBLIES MATCHING THE REMAINING ADJACENT <br />CONSTRUCTION ASSEMBLY AND FINISH MATERIALS IN KIND, STRENGTH, AND <br />APPEARANCE, SO AS TO BE STRUCTURALLY INTEGRATED WITH THE REMAINING <br />CONSTRUCTION AND TO FINISH UNIFORMLY WITHOUT TELEGRAPHING <br />DIFFERENCES BETWEEN THE NEW, PATCHES AND REMAINING CONSTRUCTION, <br />5. THE WORD "PROVIDE", WHERE USED ON THESE DRAWINGS, MEANS TO FURNISH <br />AND INSTALL THE REFERENCED ITEM OR FEATURE SO THAT IT IS COMPLETE AND <br />FULLY FUNCTIONING ACCORDING TO IT'S INTENDED PURPOSE AND THE OWNER'S <br />REQUIREMENTS. INCLUDE ALL MATERIALS, LABOR, AND COORDINATION WITH <br />OTHER WORK REQUIRED TO ACCOMPLISH THIS OBJECTIVE. PROVIDE FINISHED <br />WORK THAT MEETS OR EXCEEDS CURRENT CONSTRUCTION INDUSTRY STANDARDS <br />FOR QUALITY AND PERFORMANCE. THE WORK WILL BE CONSIDERED COMPLETE <br />AND ACCEPTABLE ONLY AFTER INSPECTION AND APPROVAL BY THE OWNER, THE <br />ARCHITECT, AND THE AUTHORITY HAVING JURISDICTION. <br />6. ITEMS OR FEATURES NOTED "TYPICAL" (TYP) ON THE DRAWINGS APPLY FOR ALL <br />SIMILAR ITEMS OR FEATURES ON THESE DRAWINGS UNLESS OTHERWISE NOTED. <br />7. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN. <br />8. TOP OF CONC SLAB ELEV 0'-0" ON THE ARCHITECTURAL DRAWING SHEETS <br />CORRESPONDS TO THE EXISTING LOWEST FINISH FLOOR OF THE EXISTING BUILDING <br />9. PROVIDE, TO THE ARCHITECT AND THE AUTHORITY HAVING JURISDICTION, A <br />FLORIDA PRODUCT APPROVAL, ISSUED BY THE FLORIDA DEPARTMENT OF <br />BUSINESS & PROFESSIONAL REGULATION, OR A MIAMI-DADE NOTICE OF <br />ACCEPTANCE (NOA), ISSUED BY THE MIAMI-DADE COUNTY GOVERNMENT, <br />CERTIFYING THAT TESTING, APPROVED AND MONITORED NY THESE AGENCIES, <br />HAS SUFFICIENTLY DEMONSTRATED THAT EACH EXTERIOR BUILDING <br />COMPONENT AND CLADDING ASSEMBLY, AS DESIGNED AND MANUFACTURED, <br />WILL WITHSTAND THE WIND PRESSURES AND WIND-BORNE MISSILE IMPACT <br />FORCES IN COMPLIANCE WITH ALL CODE AND JURISDICTIONAL REQUIREMENTS <br />FOR THE PROJECT LOCATION WHEN INSTALLED ACCORDING TO THE <br />MANUFACTURER'S SPECIFICATIONS AND INSTRUCTIONS AD WELL AS THOSE <br />INSTRUCTIONS THAT MAY BE PROVIDED WITHE THE FLORIDA PRODUCT <br />APPROVAL OR NOA DOCUMENTS. <br />10. KEEP AND MAINTAIN ON THE JOB SITE COMPLETE AND LEGIBLE SETS OF <br />CONSTRUCTION DOCUMENTS, ADDENDA, SUPPLEMENTAL INSTRUCTIONS, <br />SUPPLEMENTAL DRAWINGS, MEETING NOTES, ETC. <br />11. TREAT THE SOIL WITH APPROVED TERMITICIDE UNDER ALL NEW SLAB AREAS <br />OF THE BUILDING. <br />12. PROVIDE A 6 MIL VAPOR BARRIER UNDER ALL NEW SLAB AREAS. <br />13. PROVIDE FIRE -RETARDANT TREATED WOOD FOR ALL WOOD BLOCKING & NAILERS <br />USED IN CONCEALED SPACES. <br />14. LOCATE AND CONCEAL CONDUIT, PIPING, ETC. WITHIN WALL CAVITIES OR UNDER <br />SLABS AS MUCH AS POSSIBLE. PROVIDE ACCESS BOXES WITH REMOVABLE <br />COVERS FOR VALVES, CLEANOUTS, JUNCTION BOXES, ETC, WHERE REQUIRED. <br />15. PROVIDE GALVANIZED STEEL FOR ALL STRUCTURAL STEEL AND STEEL DECK. <br />16. WHERE DISSIMILAR METALS MAY CONTACT EACH OTHER OR WHERE METALS <br />MAY CONTACT CORROSIVE SUBSTRATES, SUCH AS CEMENTIOUS OR WOOD <br />SUBSTRATES, PROTECT AGAINST GALVANIC ACTION BY PAINTING CONTACT <br />SURFACES WITH A BITUMINOUS COATING OR BY OTHER TYPE OF PERMANENT <br />SEPARATION AS RECOMMENDED BY SMACMA. <br />17. COORDINATE KEYING OF ALL DOORS WITH THE OWNER. <br />18. CONTRACTOR SHALL PROVIDE PROPER SAFEGUARDS IN COMPLIANCE WITH CODES <br />DURING ALL PHASES OF CONSTRUCTION. <br />19. CONTRACTOR TO INSTALL BARRIERS AS NECESSARY AND REQUIRED AROUND <br />PERIMETER OF CONSTRUCTION LIMITS TO PROTECT THE PUBLIC. <br />20. CONTRACTOR TO REMOVE ALL DEBRIS FROM SITE AT END OF EACH DAY. <br />COPYRIGHT NOTE <br />THE ARCHITECT'S COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS ARE <br />HEREBY RESERVED IN THE IDEAS, DESIGNS, PLANS, DRAWINGS, AND SPECIFICATIONS <br />PRODUCED BY THE ARCHITECT. THESE IDEAS, DESIGNS, PLANS, DRAWINGS, AND <br />SPECIFICATIONS SHALL NOT BE REPRODUCED OR CONVEYED IN ANY MANNER NOR <br />ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN <br />PERMISSION OF THE ARCHITECT. CONSENT IS HEREBY GRANTED TO GOVERNMENTAL <br />AGENCIES TO REPRODUCE THE CONSTRUCTION DRAWINGS IN COMPLIANCE WITH STATE <br />STATUTES. TO THE BEST OF THE ARCHITECT'S OR ENGINEER'S KNOWLEDGE, THE PLANS <br />AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES AND <br />THE APPLICABLE FIRE SAFETY STANDARDS AS DETERMINED BY THE LOCAL AUTHORITY <br />IN ACCORDANCE WITH CHAPTERS 553 AND 633 OF THE FLORIDA STATUTES. <br />FIRE DEPARTMENT NOTES <br />1. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A <br />WITHIN 75 FOOT TRAVEL DISTANCE TO ALL PORTIONS OF THE BUILDING ON EACH <br />FLOOR, AND ADDITIONAL EXTINGUISHERS AS REQUIRED BY FIRE DEPARTMENT FIELD <br />INSPECTOR OR BUILDING DEPARTMENT INSPECTOR. <br />2. PROVIDE EXIT SIGN WITH 6" LETTERS OVER REQUIRED EXITS, WHERE SHOWN ON <br />DRAWINGS, AND ADDITIONAL SIGNS AS REQUIRED BY BUILDING DEPARTMENT <br />INSPECTOR OR FIRE DEPARTMENT FIELD INSPECTOR. CONNECT EXIT SIGNS TO <br />EMERGENCY POWER CIRCUITS, COMPLY WITH BUILDING CODES. <br />3. MAINTAIN AISLES AT LEAST 44" WIDE AT PUBLIC AREAS. <br />4. EVERY EXIT DOOR SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY <br />OR ANY SPECIAL KNOWLEDGE OR EFFORT. SPECIAL LOCKING DEVICES SHALL BE OF <br />AN APPROVED TYPE. ALL NEW DOORS SHALL HAVE APPROVED LEVER HANDLES. <br />5. DOORS OPENING INTO REQUIRED 1-HOUR, FIRE -RESISTIVE CORRIDORS SHALL BE <br />PROTECTED WITH A SMOKE OR DRAFT STOP ASSEMBLY HAVING A 20-MINUTE RATING <br />AND SHALL BE SELF -CLOSING. (WHERE REQUIRED) <br />6. 20-MINUTE DOOR JAMBS TO BE TIGHT -FITTING, SMOKE AND DRAFT CONTROLLED. <br />7. EXIT DOORS SHALL SWING IN THE DIRECTION OF TRAVEL WHEN SERVING 50 OR <br />MORE PERSONS AND IN ANY HAZARDOUS AREA. <br />8. INTERIOR WALL AND CEILING FINISHES FOR EXIT CORRIDOR SHALL NOT EXCEED AN <br />END POINT FLAME SPREAD RATING: <br />A. CLASS I, FLAME SPREAD 0-25, SMOKE DENSITY 150, FOR MATERIALS INSTALLED IN <br />VERTICAL EXITS. <br />B. CLASS II, FLAME SPREAD 26-75, SMOKE DENSITY 300, FOR MATERIALS INSTALLED <br />IN HORIZONTAL EXITS. <br />C. CLASS III, FLAME SPREAD 76-200, SMOKE DENSITY 450, FOR MATERIALS <br />INSTALLED IN ANY OTHER LOCATION. <br />9. DECORATIONS (CURTAINS, DRAPES, SHADES, HANGINGS, ETC.) SHALL BE <br />NON-COMBUSTIBLE OR BE FLAMEPROOFED IN AN APPROVED MANNER. <br />10. PROVIDE FIRE DAMPERS OR DOORS WHERE AIR DUCTS PENETRATE FIRE -RATED <br />WALLS OR CEILINGS. <br />11. STORAGE, DISPENSING OR USE OF ANY FLAMMABLE OR COMBUSTIBLE LIQUIDS, <br />FLAMMABLE GAS AND HAZARDOUS SUBSTANCES SHALL COMPLY WITH UNIFORM <br />FIRE CODE REGULATIONS. <br />12. WOOD BLOCKING SHALL BE FIRE TREATED IN ACCORDANCE WITH APPLICABLE <br />CODE REQUIREMENTS. <br />13. PROVIDE NEW, EXTEND OR MODIFY EXISTING FIRE/ LIFE SAFETY SYSTEM AS REQUIRED TO <br />PROVIDE AN APPROVED FIRE/ LIFE SAFETY SYSTEM. SUBMIT PLANS TO FIRE DEPARTMENT <br />WITH COMPLETE DESCRIPTION OF SEQUENCE OF OPERATION, AND OBTAIN APPROVAL <br />PRIOR TO INSTALLATION. <br />ACCESSIBILITY NOTES <br />I. IN BUILDINGS AND FACILITIES, FLOORS OF A GIVEN STORY SHALL BE A COMMON <br />LEVEL THROUGHOUT.OR SHALL BE CONNECTED BY PEDESTRIAN RAMPS.PASSENGER <br />ELEVATORS OR SPECIAL ACCESS LIFTS. <br />2. FLOOR SURFACES SHALL BE SLIP -RESISTANT. <br />3. EVERY CORRIDOR AND AISLE SERVING AN OCCUPANT LOAD OF 10 OR MORE <br />SHALL BE NOT LESS THAN 44' IN WIDTH. <br />4. ABRUPT CHANGES IN LEVEL ALONG ANY ACCESSIBLE ROUTE SHALL NOT EXCEED <br />1/2' IN HEIGHT. LEVEL CHANGES NOT EXCEEDING 1/4' MAY BE VERTICAL. BEVEL <br />OTHERS WITH A SLOPE NO GREATER THAN 1:2 <br />5. LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE IN <br />A PATH OF TRAVEL SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE <br />HARDWARE, PANIC BARS, PUSH-PULL ACTIVATING BARS, OR OTHER HARDWARE <br />DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE <br />OPENING HARDWARE. MOUNT DOOR OPENING HARDWARE BETWEEN 30' AND 44' <br />ABOVE FLOOR FINISH. <br />6. CENTER HAND ACTIVATED DOOR OPENING HARDWARE BETWEEN 30' AND 44' <br />ABOVE THE FLOOR. <br />7. MAXIMUM PULL OR PUSH EFFORT TO OPERATE DOORS SHALL NOT EXCEED 8.5 <br />POUNDS FOR EXTERIOR DOORS AND 5 POUNDS FOR INTERIOR DOORS, MEASURED <br />AT RIGHT ANGLES TO HINGED DOORS AND AT CENTER PLANE OF SLIDING OR <br />FOLDING DOORS. CORRESPONDING DEVICES OR AUTOMATIC DOOR OPERATORS <br />MAY BE UTILIZED TO MEET THE ABOVE STANDARDS. MAXIMUM EFFORT TO OPERATE <br />REQUIRED FIRE DOORS MAY BE INCREASED NOT TO EXCEED 15 POUNDS. <br />8. THE BOTTOM 10' OF ALL DOORS (EXCEPT SLIDING AND AUTOMATIC) SHALL HAVE A <br />SMOOTH UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A <br />WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. <br />PROVIDE A 10' HIGH SMOOTH PANEL ON THE PUSH SIDE OF NARROW FRAME <br />DOORS. <br />9. EVERY REQUIRED ENTRANCE OR PASSAGE DOORWAY SHALL BE NOT LESS THAN 3' IN <br />WIDTH AND NOT LESS THAN 6'-8' IN HEIGHT. DOORS SHALL BE CAPABLE OF <br />OPENING AT LEAST 90 DEGREES AND SHALL BE SO MOUNTED THAT THE CLEAR WIDTH <br />OF THE DOORWAY IS NOT LESS THAN 32'. <br />10. WHERE A PAIR OF DOORS IS UTILIZED. AT LEAST ONE OF THE DOORS SHALL PROVIDE <br />A CLEAR, UNOBSTRUCTED OPENING WIDTH OF 32' WITH THE LEAF POSITIONED AT AN <br />ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION. <br />II. IDENTIFY ACCESSIBLE ENTRANCES WITH AT LEAST ONE STANDARD SIGN AND WITH <br />ADDITIONAL DIRECTIONAL SIGNS, AS REQUIRED, VISIBLE FROM APPROACHING <br />PEDESTRIAN WAYS. <br />12. THE FLOOR OR LANDING ON EACH SIDE OF AN ENTRANCE OR PASSAGE DOOR <br />SHALL BE LEVEL AND CLEAR.THE LEVEL AND CLEAR AREA SHALL HAVE A LENGTH IN <br />THE DIRECTION OF DOOR SWING OF AT LEAST 60' AND THE LENGTH OPPOSITE THE <br />DIRECTION OF DOOR SWING OF 44' AS MEASURED AT RIGHT ANGLES TO THE PLANE <br />OF THE DOOR IN ITS CLOSED POSITION. <br />13. FLOORS OR LANDINGS SHALL BE NOT MORE THAN 112'LOWER THAN THE THRESHOLD <br />OF THE DOORWAY. CHANGE IN LEVEL BETWEEN 1/4' AND 1/2' SHALL BE BEVELED <br />WITH A SLOPE NO GREATER THAN 1:2. <br />14. TO ALERT THE VISUALLY IMPAIRED, MARK THE UPPER APPROACH AND THE LOWER <br />TREAD OF EACH INTERIOR STAIR WITH A STRIP OF CLEARLY CONTRASTING COLOR <br />AT LEAST 2' WIDE, PLACED PARALLEL TO AND NOT MORE THAN V FROM THE NOSE <br />OF THE STEP OR LANDING. THE STRIP SHALL BE OF A MATERIAL THAT IS AT LEAST AS <br />SLIP RESISTANT AS THE OTHER TREADS OF THE STAIR. <br />15. CENTER ELECTRICAL RECEPTACLE OUTLETS NOT LESS THAN 15' ABOVE THE FLOOR <br />OR WORKING PLATFORM. <br />16. SANITARY FACILITIES LOCATED ON AN ACCESSIBLE FLOOR OF A BUILDING SHALL BE <br />ACCESSIBLE TO THE PHYSICALLY HANDICAPPED. <br />r---I <br />n I I IQ r - - - - <br />-- <br />V <br />p 118' MIN 142' MIN <br />FRONT APPROACH, FRONT APPROACH, HINGE APPROACH, <br />PULL SIDE PUSH SIDE PULL SIDE <br />z <br />I p 136' MIN <br />12' MIN I c N I 22' MIN <br />HINGE APPROACH, <br />FRONT APPROACH, PULL SIDE HINGE APPROACH, <br />PUSH SIDE DOOR PULL SIDE <br />PROVIDED WITH <br />BOTH CLOSER AND <br />LATCH <br />z a z ---a <br />j 122' MIN c 124' MIN � 24' MIN <br />_71"F <br />LATCH APPROACH, LATCH APPROACH, <br />PULL SIDE PULL SIDE, DOOR <br />HINGE APPROACH, PROVIDED WITH <br />PUSH SIDE DOOR CLOSER <br />PROVIDED WITH <br />BOTH CLOSER AND <br />LATCH <br />z <br />I i 2 1� I <br />v 4 24'IMIN Q I 24':MIN <br />LATCH APPROACH, LATCH APPROACH, <br />PUSH SIDE PUSH SIDE, DOOR <br />PROVIDED WITH <br />CLOSER <br />REFER TO FLORIDA ACCESSIBILITY CODE 2014 CHAPTER 4 <br />3 CLEARANCES AT DOORS <br />G1.2 NOT TO SCALE <br />8'. EO EO 8". <br />EXIT SIGN - <br />PRECAST CONCRETE LINTEL. LENGTH - <br />CUT TO BLOCK DIMENSIONS TYP. <br />i, 8" ABOVE T/O FRAME HEAD <br />Y B/O EXIT SIGN <br />ik 80" AFF <br />B/O STROBE <br />OL 60" AFF <br />I <br />48" AFF <br />T/O OUTLET, LIGHT <br />SWITCH, PULL STATION <br />OIL 16" AFF <br />B/O OUTLET <br />OIL FINISH FLOOR <br />FIRE ALARM <br />STROBE <br />ROOM SIGNAGE <br />FIRE ALARM <br />PULL STATION <br />LIGHT SWATCH <br />ELECTRICAL OR <br />COMMUNICATIONS <br />OU TILE T <br />12' ��. DOOR FRAME �I� 12' FIRE <br />EXTINGUISHER <br />CABINET <br />THERMOSTAT <br />ELECTRICAL OR <br />COMMUNICATIONS <br />OUTLET ABOVE <br />COUNTERTOP <br />TYPICAL DEVICE PLACEMENT <br />NOT TO SCALE <br />SECTION A -A <br />1. WALL ASSEMBLY - THE FIRE RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY SHALL <br />BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL <br />U300 OR U400 SERIES WALL AND PARTITION DESIGNS IN THE UL FIRE RESISTANCE <br />DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: <br />A. STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL <br />STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. LUMBER SPACED 16 IN. OC. <br />STEEL STUDS TO BE MIN 3-5/8 IN. WIDE AND SPACED MAX 24 IN. OC. <br />B. GYPSUM BOARD' - NOM 5/8 IN. THICK GYPSUM WALLBOARD, AS SPECIFIED IN THE <br />INDIVIDUAL WALL AND PARTITION DESIGN. DIAM OF OPENING IS 1-1/2 IN. LARGER <br />THAN THE OUTSIDE DIAM OF PIPE. <br />2. THROUGH PENETRANT - ONE METALLIC PIPE, CONDUIT OR TUBING TO BE CENTERED <br />WITHIN THE FIRESTOP SYSTEM. AN ANNULAR SPACE OF 3/4 IN. IS REQUIRED WITHIN THE <br />FIRESTOP SYSTEM. PIPE, CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES <br />OF WALL ASSEMBLY, THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES, CONDUITS OR <br />TUBING MAY BE USED: <br />A. STEEL PIPE - NOM 12 IN. DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE. <br />B. CONDUIT - NOM 6 IN. DIAM (OR SMALLER) ELECTRICAL METALLIC TUBING OR STEEL <br />CONDUIT, <br />C. COPPER TUBING - NOM 6 IN. DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING. <br />D. COPPER PIPE - NOM 6 IN. DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE. <br />3. FILL, VOID OR CAVITY MATERIAL ' - SEALANT MIN 5/8 IN. THICKNESS OF FILL MATERIAL <br />APPLIED WITHIN ANNULUS, FLUSH WITH BOTH SURFACES OF WALL ASSEMBLY. <br />3M COMPANY FB-2000+ <br />*BEARING THE UL CLASSIFICATION MARKING SYSTEM N0. W-L-1084 <br />JULY 29, 1995 <br />F RATING - 1 HR <br />T RATING - 0 HR <br />UL SYSTEM NO. W-L-1084 <br />PIPE PENETRATIONS <br />30' <br />MIT <br />48' <br />z Off, <br />cal I � <br />EQI <br />FORWARD PARALLEL <br />APPROACH APPROACH <br />x <br />SPOUT <br />LOCATION <br />z <br />WATER COOLER <br />CLEARANCES <br />16--188' c <br />I MIRROR <br />TOP 'MIN. <br />M 36'IMIN <br />:60' MIN <br />CLEAR FLOOR SPACE <br />TYPICAL <br />CLEARANCES <br />54' MIN. <br />TOILET 42' MIN. <br />PAPER <br />TOP <br />' <br />Zn <br />l t�71 <br />1. 56' MIN <br />CLEAR FLOOR SPACE <br />WATER CL O SET <br />CLEARANCES <br />UPPER SPOUT HEIGHT <br />LOWER SPOUT HEIGHT 19' MIRROR <br />NOTE: - X �' TOE CLEARANCE <br />DUAL UNITS STANDARD k a F w <br />AND WHEEL CHAIR ACCESS a P W a x z z ? z <br />EQUIPMENT PERMITTED IN Z M pP �� > 1 2 3 <br />SHADED AREA17 <br />Inrn N N In <br />N <br />8' MIN. 8' MIN. 6' MAX. <br />6' MAX. KNEE 17' <br />CLEARANCE MIN DEPTH <br />X <br />WATER COOLER LAVATORY LAVATORY <br />CLEARANCES CLEARANCES CLEARANCES <br />� <br />ACCESSIBLE TOILET NOTES: <br />x <br />w <br />w <br />1. <br />WATER CLOSET SEATS SHALL BE MOUNTED BETWEEN 17-19 INCHES MEASURED FROM THE FINISH FLOOR TO THE <br />iv Lr <br />TOP OF THE SEAT, <br />O <br />ro <br />2. <br />GRAB BARS SHALL BE PROVIDED AND LOCATED 33-36 INCHES FROM THE FINISH FLOOR AND SHALL BE PARALLEL <br />TO THE FLOOR. OUTSIDE DIAMETER OF GRAB BAR SHALL BE 1-1/2" AND SHALL PROVIDE 1-1/2" OF CLEARANCE <br />BETWEEN THE RAIL AND WALL. GRAB BARS SHALL BE STAINLESS STEEL AND SHALL SUPPORT A LOAD OF 250 LBS. <br />APPLIED AT ANY POINT DOWNWARD OR HORIZONTALLY. <br />3. <br />SIDE BAR SHALL BE 42" LONG MINIMUM AND MOUNTED 12" FROM WALL TO EDGE OF GRAB BAR - REAR BAR <br />SHALL BE 36" LONG (MIN.) MOUNTED 12" MIN. OFF CENTER OF THE TOILET TO WALL SIDE EDGE OF GRAB BAR. <br />4. <br />FLUSH CONTROLS, TOILET PAPER DISPENCERS, FAUCETS, ETC. SHALL COMPLY WITH ALL CODE REQUIREMENTS. <br />5. <br />LAVATORIES SHALL HAVE LEVER OPERATED FAUCETS AND NARROW APRONS AND SHALL BE MOUNTED AT A <br />MAXIMUM OF 34 INCHES AS MEASURED FROM THE FINISH FLOOR. TOE AND KNEE CLEARANCES SHALL BE AS SHOWN <br />ON THE DETAIL. <br />6. <br />HOT WATER AND DRAIN PIPES UNDER LAVATORIES SHALL BE INSULATED OR OTHERWISE PROTECTED. THERE SHALL <br />BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES. <br />7. <br />PROVIDE A MIRROR IN EACH TOILET ROOM AS SHOWN OR A MINIMUM OF 18" X 30" WITH THE BOTTOM EDGE OF THE <br />REFLECTING SURFACE MOUNTED NO HIGHER THAN 40" ABOVE THE FINISH FLOOR. <br />8. <br />PROVIDE A STAINLESS STEEL TOILET PAPER DISPENSER IN EACH TOILET ROOM MOUNTED AT A MINIMUM OF 19" ABOVE <br />FINISHED FLOOR. PROVIDE A STAINLESS STEEL SANITARY NAPKIN DISPENSER IN TOILET ROOMS DESIGNATED AS WOMANS <br />TOILET ROOMS. <br />9. <br />TYPICAL TOILET ROOM DOOR SHALL BE 3'-0" X 6'-8" WITH ADA AND FLORIDA HANDICAP APPROVED PRIVACY HARDWARE <br />PROVIDE ADA APPROVED SIGNAGE AT THE EXTERIOR FACE OF DOOR AS SHOWN ON 4/C1.2 <br />10. <br />H.C. TOILET ROOMS SHALL COMPLY WITH ALL APPLICABLE REQUIREMENTS OF THE FLORIDA HANDICAP CODE, THE ADA, <br />AND ALL OTHER APPLICABLE CODES. <br />1 ACCESSIBLE TOILET DIMENSIONS <br />(_1 7 1 SCALE 1/4' = I'-0' <br />I I <br />I I <br />z I I <br />z I � I 1 z I <br />I t v I 1 > 1 I <br />1 <br />rn I I I I fn I I <br />L--------1 L --- I I---------1 <br />L 48' MIN 30' MIN 1 48' MIN <br />III L <br />CLEAR FLOOR SPACE FORWARD APPROACH PARALLEL APPROACH <br />c <br />N <br />x <br />60' MIN <br />x z <br />L_. <br />I I <br />I�----------I Z <br />F I'll M 60' MIN ,- \\`�--���/ I I `v <br />36' MIN L 60' MIN 12- 1 36 MIN 1 12' 1 <br />MIN MIN <br />CLEAR FLOOR SPACE IN ALCOVES TURNING SPACE <br />REFER TO FLORIDA ACCESSIBILITY CODE 2017 CHAPTER 3 <br />MINIMIM CLEAR FLOOR <br />2 SPACE FOR WHEEL CHAIR S <br />Revisions Date By <br />Mark A. lonnatti <br />Florida Ali 0010778 <br />JONNATTI <br />ARCHITECTURE <br />INCORPORATED <br />21021 US Highway 19 N <br />Clearwater, Florida 33765 <br />(727) 725 ARCH <br />(727) 725-2603 fx <br />www. jarch. com <br />info@jarch.com <br />® JonnattiArchitecture <br />Incorporated 2022 <br />ZEPHR <br />RETAIL <br />DEVELOPMENT <br />DOC MJ <br />SUITE 6603 <br />US HWY 301 <br />GALL BL VD <br />ZEPHYRHILLS <br />FLORIDA <br />33542 <br />GENERAL <br />NOTES AND <br />DETAILS <br />Drawn <br />MAJ <br />Check <br />MAJ <br />Date <br />JAN 18, 2022 <br />Scale <br />AS NOTED <br />Job No <br />ZEPHR RB <br />G102 <br />NOT TO SCALE <br />