Laserfiche WebLink
ELECTRICAL LEGEND <br />SYMBOL <br />DESCRIPTION <br />N <br />LAY -IN CEILING RECESSED LIGHT FIXTURE (OR SURFACE MOUNTED "CLOUD" FIXTURE WHERE <br />SCHEDULED) LETTER DENOTES MARK IN LIGHTING FIXTURE SCHEDULE <br />ig EX <br />EXIT LIGHT FIXTURE <br />LETTER DENOTES MARK IN FIXTURE SCHEDULE <br />1�kEM <br />EMERGENCY LIGHT FIXTURE <br />LETTER DENOTES MARK IN FIXTURE SCHEDULE <br />t <br />FLUSH MOUNTED SINGLE POLE WALL SWITCH, 20 AMP, HUBBELL CAT. NO. 12211 OR EQUAL <br />$M <br />LEVITON OSS10 OR LUTRON LOS-SIR-HD OCCUPANCY SENSOR WALL SWITCH <br />FLUSH MOUNTED DUPLEX WALL RECEPTACLE. NEMA 5-15R. MOUNTED AT 19" AFF UNLESS NOTED <br />OTHERWISE <br />&D <br />DEDICATED FLUSH MOUNTED DUPLEX WALL RECEPTACLE, NEMA 5-15R, MOUNTED AT 19" AFF UNLESS <br />NOTED OTHERWISE <br />FLUSH MOUNTED QUAD WALL RECEPTACLE, NEMA 5-15R, MOUNTED AT 19" AFF UNLESS NOTED <br />OTHERWISE <br />PANEL <br />ELECTRICAL PANEL: LETTERING IDENTIFIES PANEL <br />EF <br />ELECTRICAL FAN - SEE MECHANICAL PLAN <br />LIGHT FIXTURE SCHEDULE <br />TYPE <br />MANUACTMRER <br />CATALOG li <br />VOLTS <br />WATTS <br />LAMPS <br />MOMNTIlVG <br />NOTES <br />A <br />LITHONIA LIGHTING <br />2BLT4 40L ADP EZI LP840 <br />120 <br />38 <br />LED <br />CEILING/RECESS <br />1,2 <br />EX <br />LITHONIA LIGHTING <br />ELM4L <br />120 <br />3.15 <br />LED <br />WALL <br />3.4 <br />EMX <br />LITHONIA LIGHTING <br />ECRG RD M6 <br />120 <br />2 <br />LED <br />CEILING/SURFACE <br />3,4 <br />LIGHT CONTROL SCHEDULE <br />TYPE <br />MAAWACTIIRER <br />DESCRIPTION <br />CATALOG Ii <br />VOLTS <br />NOTES <br />ACUITY <br />WALL MOUNT LINE VOLT VACANCY SENSOR <br />WSX PDT SA WH <br />120V <br />--- <br />$Lv <br />ACUITY <br />WALL MOUNT LOW VOLTAGE OVERRIDE SWITCH <br />nPODM WH <br />LOW VOLTAGE <br />RJ-45 CONNECTIONS <br />os <br />ACUITY <br />CEILING MOUNT LOW VOLT OCCUPANCY SENSOR <br />nCM PDT 9 RJB <br />LOW VOLTAGE <br />RJ-45 CONNECTIONS <br />ACUITY <br />nLIGHT POWER PACK <br />I nPP16 EFP <br />LOW VOLTAGE <br />RJ-45 CONNECTIONS <br />NOTES: <br />I. CONNECT AHEAD OF SWITCHING. <br />2. VERIFY MOUNTING HEIGHT WITH OWNER/ARCHITECT. <br />3. CONNECT BATTERY TO STRAIGHT HOT LIGHTING CIRCUIT. <br />4. PROVIDE WITH 90 MINUTE BACKUP OPTION. <br />PANEL <br />B <br />SURFACEMOUNTED <br />120/208 VOLT 3 PHASE <br />4 W IRE W ITH GROUND <br />EXISTING(RELOCATED) <br />200A MIA <br />NEMA 1 <br />NOTES <br />CKT. <br />DESCRIPTION <br />BREAKER <br />A <br />B <br />C <br />BREAKER <br />DESCRIPTION <br />CKT. <br />NOTES <br />NO. <br />TRIP <br />POLE <br />VOLT <br />VOLT <br />POLE <br />TRIP <br />NO. <br />2 <br />11 <br />SPARE <br />20 <br />1 <br />120 <br />1 3480 <br />120 <br />1 <br />30 <br />INSTA-HOT <br />2 <br />5 <br />1 <br />3 <br />LIGHTING <br />20 <br />1 <br />120 <br />469 <br />ZO88 <br />208 <br />3 <br />25 <br />RTU-1 <br />4 <br />3 <br />2 <br />5 <br />RECEPTACLE <br />20 <br />1 <br />120 <br />540 1 2088 <br />208 <br />3 <br />25 <br />6 <br />3 <br />2 <br />7 <br />RECEPTACLES <br />20 <br />1 <br />120 <br />720 1 2088 <br />208 <br />3 <br />25 <br />8 <br />2 <br />9 <br />RECEPTACLES <br />20 <br />1 <br />120 <br />720 <br />1 180 <br />120 <br />1 <br />20 <br />1 ROOFTOP RECEPTACLE <br />10 <br />2 <br />111 <br />1 <br />12 <br />13 <br />14 <br />15 <br />16 <br />17 <br />18 <br />19 <br />20 <br />211 <br />22 <br />231 <br />24 <br />25 <br />26 <br />27 <br />28 <br />29 <br />30 <br />31 <br />32 <br />33 <br />34 <br />351 <br />36 <br />37 <br />1 <br />208 <br />3 <br />30 <br />SPD <br />38 <br />39 <br />1 <br />208 <br />3 <br />30 <br />40 <br />41 <br />1 <br />208 <br />3 <br />1 30 <br />42 <br />CONNECTED VA <br />SYSTEM VOLTS <br />PHASEAMPS <br />6298 34571 <br />120/208V, 3 PHASE <br />52 29 <br />CONNECTED NEC DEMAND <br />469 1.25 <br />2160 1 <br />4176 1 <br />0 0 <br />3480 1 <br />0 1.25 <br />0 0.66 <br />TOTAL <br />1N208V 3 PHASE 1 <br />2628 <br />22 <br />DEMAND LOAD <br />586.25 VA <br />2160 VA <br />4176 VA <br />0 VA <br />3480 VA <br />0 VA <br />0 VA <br />110402 VA <br />1 29M <br />NOTES ( ) <br />(I1 BREMCE RS FOR MULTI WIIRE BRANCH CIRCUITS TO BE <br />SUPPLIED WrMIWHANDLES. <br />NOTES <br />LOAD TYPE <br />IS LARGER <br />1 <br />LIGHTING <br />2 <br />RECEPTACLES <br />3 <br />AIR CONDITIONING <br />4 <br />HEATING <br />5 <br />MISC. NON -CONTINUOUS <br />6 <br />CONTINUOUS <br />7 <br />KITCHEN <br />LIGHTING PLAN <br />SCALE 1/8" = 1'-0" <br />0 <br />EXISTING 120408 3-PHASE SERVICE <br />POWER RISER DIAGRAM - <br />NOT TO SCALE <br />EXISTING FEEDER SCHEDULE <br />OCU-200 <br />200A PANEL FEEDER: (3) 3/0 CU, (1) 3/0 CU NEUTRAL <br />& (1) 06 CU GROUND IN 2' CONDUIT. <br />POWER RISER NOTES: <br />O1 EXISTING 120/208V, 3-PHASE, 200A, MLO, PANEL 'B', 42 CKT, TO BE RELOCATED <br />(SEE PLANS). EXTEND WIRING AS NECESSARY. <br />a <br />°x <br />FLORIDA ENERGY CODE <br />POWER PLAN <br />BRANCH CIRCUIT WIRE SIZES SHALL COMPLY WITH FLORIDA <br />ENERGY CODE, 7TH EDITION (2020) C405.7.3.1 AND C405.7.3.2 <br />FOR VOLTAGE DROP. <br />GENERAL RULE: <br />-USE 810 FOR 20A, 277V BRANCH CIRCUITS LONGER THAN 200' <br />-USE 0110 FOR 20A, 120V BRANCH CIRCUITS LONGER THAN 75' <br />-USE 08 FOR 20A, 277V BRANCH CIRCUITS LONGER THAN 250' <br />-USE 48 FOR 20A, 120V BRANCH CIRCUITS LONGER THAN 150' <br />ARC FLASH NOTE <br />THE ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL <br />SIGNAGE/LABELS FOR ARC FLASH/SHOCK HAZARD FOR ALL <br />SERVICE EQUIPMENT AS PER N.E.C. ART. 110.24 AND NFPA <br />70E. SIGNAGE/LABELS MUST SUITABLE TO WITHSTAND THE <br />ENVIRONMENT AND SHALL INCLUDE THE MAXIMUM AVAILABLE <br />FAULT CURRENT, LEVEL OF PPE REQUIRED, APPROACH <br />BOUNDARIES AND DATE OF CALCULATION. <br />SCALE 1/8' = 1'-0" <br />ELECTRICAL NOTES: <br />I. ALL ELECTRICAL WORK SHALL BE IN COMPLIANCE WITH THE 2020 FLORIDA BUILDING <br />CODE, 2017 NATIONAL ELECTRIC CODE AND ALL OTHER APPLICABLE CODES AND <br />ORDINANCES. <br />2. GENERAL CONTRACTOR SHALL INCLUDE ALL WORK REQUIRED FOR A COMPLETE <br />INSTALLATION AND FOR PROPER OPERATION OF ELECTRICAL SYSTEMS, INCLUDING ALL <br />WORK REQUIRED BY CODE OR REGULATORY AGENCIES. <br />3. CONTRACTOR SHALL COORDINATE THE INSTALLATION OF INTERNE(DATA) CONNECTIONS <br />TO THE BUILDING. INTERNET PROVIDERS ARE TO BE PROVIDED BY THE OWNER. MAKE <br />PROVIDER CONNECTIONS FROM THE LOCATIONS OFF -SITE TO THE LIMITED ENERGY <br />SYSTEMS PANEL. <br />4. ALL SWITCHES, RECEPTACLES. & COVER PLATES SHALL BE WHITE DECORA TYPE. <br />REPLACE EXISTING TO REMAIN AS NECESSARY. <br />5. EGRESS ILLUMINATION CONFORMS TO COMMERCIAL REQUIREMENTS OF IFC IN THE PATH <br />OF EXIT PER FBC 1006.1 <br />6. ALL COMMERCIAL LIGHTING CONTROLS COMPLY WITH THE FLORIDA ENERGY CODE E C405. <br />ELECTRICAL POWER KEYNOTES: <br />O1 RELOCATED 120/208V, 3-PHASE 200A, MLO PANEL W. <br />SEE SHELL BLDG DRAWINGS FOA ORIGINAL LOCATION. <br />O2 EXISTING METER. <br />O3 ELECTRICAL CONTRACTOR TO CONFIRM EXACT 'CU" & 'AHU' ELECTRICAL SPECS. <br />NOTIFY ELECTRICAL ENGINEER OF RECORD OF ANY CHANGES TO BREAKER SIZES. <br />O4 HVAC, DISCONNECT & RECEPTACLE SHOWN FOR CLARITY (TYP.). <br />ELECTRICAL LIGHTING KEYNOTES: <br />O1 CONNECT TO NEAREST 'CONSTANT HOT' POWER SOURCE. USE LIGHTING CIRCUITS ONLY. <br />O CONNECT TO BATHROOM MOTION SWITCH. <br />ELECTRICAL LIGHTING CONTROL ORDER OF OPERATION: <br />USER IS TO TURN SWITCHLEGS ON MANUALLY. MOTION SENSORS ARE TO TURN OFF <br />ALL FIXTURES AFTER NO MOTION IS DETECTED FOR A SET PERIOD OF TIME. <br />EXCEPTION: RESTROOM LIGHTS ARE ALLOWED TO BE AUTOMATIC ON / AUTOMATIC OFF. <br />TYPICAL LIGHTING CIRCUIT AND SWITCHLEG KEY <br />Fixture <br />LA I CAPITOL LETTER <br />DENOTES FIXTURE TYPE <br />CIRCUIT <br />(Constant hot provided to power pack) <br />PANEL NAME <br />PoWack CKT B - 4 3 <br />LOWERCASE LETTER <br />DENOTES SWITCHLEG <br />I CIRCUITING EXAMPLE KEY <br />CKT: a <br />DENOTES LIGHTING SWITCH LEG <br />DENOTES PANEL NAME (BY ROOM). LIGHTING PLAN ONLY <br />DENOTES CIRCUIT NUMBER <br />(Revisions Date By <br />Mark A. ]onnatti <br />Florida Ali 0010778 <br />JONNATTI <br />ARCHITECTURE <br />INCORPORATED <br />21021 US Highway 19 N <br />Clearwater, Florida 33765 <br />(727) 725 ARCH <br />(727) 725-2603 fx <br />www. jarch. com <br />info@jarch.com <br />® Jonnatti Architecture <br />Incorporated 2022 <br />�P,��.0 F• FC �90 <br />A. J04,, ••� <br />2/3/22 <br />ZEPHR <br />RETAIL <br />DEVELOPMENT <br />DOC M <br />SUITE 6603 <br />US HWY 301 <br />GALL BLVD <br />ZEPHYRHILLS <br />FLORIDA <br />33542 <br />POWER AND <br />LIGHTING <br />LAN <br />(Drawn <br />MAJ <br />Check <br />MAJ <br />Date <br />JAN 18, 2022 <br />Scale <br />AS NOTED <br />Job No <br />ZEPHR RB <br />I <br />heefi <br />El 0 1 <br />