My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6741 Shelby Lynn Way (2)
Zephyrhills
>
Building Department
>
Building Plans
>
6741 Shelby Lynn Way (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 3:38:36 PM
Creation date
2/19/2025 8:26:19 AM
Metadata
Fields
Template:
Building Plans
Street #
6741
Location
Shelby Lynn Way
Contractor
K Hovnanian
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br />0 <br />0 <br />12 <br />SEE ROOF <br />PLAN <br />INSULATION PER - <br />COMMUNITY SPEC. <br />SEE ENERGY CALCS. <br />1/2" (MIN.) CLG. BD. <br />1 x PT DRAPE BLKG - <br />ABOVE WINDOWS 1/2" <br />G.W.B. <br />WINDOW PER PLAN <br />GYP.BD. — <br />WINDOW SILL <br />1/2" GYP. BD. OVER RADIANT <br />BARRIER INSULATION (R-4.1) <br />ATTACHED TO ix2 PT. <br />FURRING @ 24" O.C. <br />BASE BOARD <br />SEE SOFFIT AT RAKE (BEYOND) <br />ROOF PLAN REFER TO PLANS <br />_ FINISH PER PLAN <br />7/8 STUCCO OVER LATH <br />W/ 60 MIN. GRADE D PAPER BACKED <br />LATH OVER BARRICADE PLUS WRB <br />(OR APPROVED EQUAL) <br />BENT METAL FLASHING <br />REFER TO "L" FLASHING DETAIL <br />2X LEDGER BOARD <br />u IN, v�Y(REFER TO ELEV.) <br />INSULATION AS 2X ALUM WRAPPED FASCIA <br />PER SPECS. ----- BD. w/ALUM DRIP EDGE <br />PRE-ENGINEERED SOFFIT INSTALLED PER <br />GABLE END ROOF MANUF. SPECS <br />TRUSS - REFER TO 2X PT BLOCKING <br />STRUCTURALS HURRICANE STRAP - REFER TO <br />STRUCTURALS <br />1/2" (MIN.) CLG. BD. MASONRY LINTEL - REFER TO <br />STRUCTURALS <br />TYP. HIPPED PENT ROOF DETAIL <br />SCALE: 1/2" = 1'-O" <br />ROOF SHINGLES OVER <br />TWO LAYERS OF ASTM D226 TYPE II OR <br />SYNTHETIC UNDERLAYMENT COMPLYING <br />WITH ASTM D226 TYPE II INSTALLED PER <br />R905.1.1.1 (SEE SHEET CS2) <br />PRE-ENGINEERED ROOF <br />TRUSSES AT TYP. 24" O.C. <br />BOTTOM CHORD VARIES. REFER <br />TO TRUSS MFGR. DRAWINGS. <br />HURRICANE STRAP EACH END <br />OF TRUSS - REFER TO <br />STRUCTURAL. <br />OIL TOP OF C.M.U. <br />(REFER TO ELEV.) <br />2x6 ALUM WRAPPED FASCIA <br />BD. w/ALUM DRIP EDGE <br />SOFFIT INSTALLED PER <br />MANUF. SPECS <br />2X PT BLOCKING <br />SEE STRUCTURAL <br />PLAN <br />PRECAST WIN. SILL <br />SLOPE GRADE AWAY <br />FROM HOUSE <br />0'-0" <br />FIN. FL. <br />FOUNDATION <br />PER STRUCTURAL DRAWINGS <br />TYP. 1-STORY WALL @ WINDOW <br />SCALE: 1/2" = 1'-O" <br />ATTIC OR <br />SECOND FLOOR <br />LIVING SPACE <br />REFER TO PLANS <br />PROVIDE 2X4 <br />FRAMED <br />ENCLOSURE FOR <br />ELECTRICAL <br />PANEL, FINISH W/ <br />J" GYPSUM <br />BOARD <br />ELECTRIC METER <br />LOCATION - SEE <br />PLANS. VERIFY <br />INSTALLATION IN <br />FIELD <br />STUCCO <br />FINISH <br />EXTERIOR \, <br />CMU BLOCK <br />WALL <br />NOTE: ELECTRICAL <br />PANEL IS TO BE <br />INSTALLED ACCORDING <br />TO ALL APPLICABLE <br />LOCAL, STATE AND <br />NATIONAL CODES. <br />VERIFY PANEL <br />DIMENSIONS PRIOR TO <br />CONSTRUCTION. <br />GYPSUM <br />BOARD z <br />a <br />3 1 /2" � <br />w <br />GARAGE a <br />J, <br />N <br />ELECTRICAL M <br />PANEL <br />N <br />CO <br />0o <br />CONCRETE CV <br />CURB REFER <br />TO PLANS <br />GRADE <br />GYPSUM — <br />BOARD <br />"' GYPSUN <br />BOARD <br />NICHE FOI <br />ELECTRIC <br />PANEL & <br />WIRING <br />ELECTRIC <br />PANEL <br />EXTERIOF <br />CMU BLOC <br />WALL <br />CONCRET <br />CURB REF <br />TO PLANS <br />DONCRETE <br />SLAB ON <br />GRADE AT <br />GARAGE <br />FLOOR <br />1-STORY - MASONRY WALL <br />ROOF SHINGLES OVER <br />TWO LAYERS OF ASTM D226 TYPE II OR <br />SYNTHETIC UNDERLAYMENT COMPLYING <br />WITH ASTM D226 TYPE II INSTALLED PER <br />12 R905.1.1.1 (SEE SHEET CS2) <br />�SEEROOF PRE-ENGINEERED ROOF <br />PLAN TRUSSES AT TYP. 24" O.C. <br />BOTTOM CHORD VARIES. REFER <br />TO TRUSS MFGR. DRAWINGS. <br />HURRICANE STRAP EACH END <br />OF TRUSS - REFER TO <br />STRUCTURAL. <br />OC TOP OF C.M.U. <br />'IF(REFER TO ELEV.) <br />2x6 ALUM WRAPPED FASCIA <br />BD. w/ALUM DRIP EDGE <br />1/2" (MIN.) ---- <br />CLG. BD. SOFFIT INSTALLED PER <br />(t" TYPE 'X' GYP. BD. MANUF. SPECS <br />TO BE PROVIDED 2X PT BLOCKING <br />WHEN LIVING SPACE <br />IS ABOVE GARAGE) SEE STRUCTURAL <br />PLAN <br />8" CMU BLOCK <br />W/ CEMENTITIOUS <br />FINISH (BEYOND) <br />EXPANSION JOINT <br />GARAGE SLAB, 4" SPECS DRIVEWAY PER COMMUNITY <br />SEE STRUCTURAL <br />PLANS SLOPE SLOPE 0'-0" <br />FIN. FL. <br />0 <br />M <br />WALL SECTION <br />SCALE: 1/2" = 1'-O" <br />ATTIC OR SECOND <br />FLOOR LIVING SPACE <br />REFER TO PLANS <br />ELECTRICAL PANEL NICHE AT CMU BLOCK WALL <br />SCALE: 1/2" = 1'-O" <br />FOUNDATION <br />PER STRUCTURAL DRAWINGS <br />GARAGE DOOR <br />NOTE: THESE DETAILS DEPICT <br />ARCHITECTURAL SPECIFICATIONS AND <br />FINISHES ONLY. REFER TO STRUCTURAL <br />DRAWINGS FOR STRUCTURAL INFORMATION <br />,,`'`01G11FR/ 4, <br />♦♦�. �1••.\GfcNSF C <br />• 77624 <br />-0 pTE OF <br />10 <br />� S <br />r,. <br />W <br />�00P <br />w cc¢O <br />p <br />c)Ufr <br />Ww <br />Q=WFQ- <br />U) W W <br />p cr cr_ <br />Y O F— Z <br />�LLOOU) <br />Z Z Z ~ Z <br />� J Q J <br />W = c a <br />a:c)p0c..) <br />- Z LL U) <br />�F--QZO <br />cz <br />Q <br />�t Q O <br />Z <br />H <br />0 <br />0 <br />0 <br />U <br />0 <br />cn <br />0 <br />z <br />0 <br />0 <br />mj ISM <br />1-i <br />m <br />w <br />UU <br />w <br />�w <br />a <br />a u) <br />w <br />w <br />w <br />2 <br />X <br />cn <br />O <br />R <br />rz <br />N <br />W <br />z <br />Z <br />04 <br />� <br />O <br />I=Z <br />aaaaa <br />I� <br />W <br />:Q= <br />Lu <br />302021 <br />COMMUNITY: <br />LINKS AT CALUSA <br />SPRINGS <br />PLAN # 6100 <br />RELEASED: 9/21/21 <br />SHEET <br />A5•2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.