My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6750 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6750 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2025 10:45:14 AM
Creation date
2/19/2025 8:26:29 AM
Metadata
Fields
Template:
Building Plans
Street #
6750
Location
Back Forty Lp
Contractor
Lennar Home
Building Plans - Permit #
6303
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- -L -- - I 1 1' 1' 1 1 1L I I 1 11 1 -- - -- -- - I I <br />- - i Afl- - - 1 1 1 <br />42" KNEE WALL WITH <br />1x8 CAP & CASING OR <br />36" RAILING <br />36" H. CONT. <br />GRASPABLE <br />RAILING <br />3/4" PLYWOOD <br />DECKING 16 <br />/ 15 <br />14 <br />13 <br />PRE-ENG FLOOR 12 <br />TRUSS <br />11 <br />1xTREAD(TYP.) 10 <br />/ 9 3/4" PLYWOOD <br />j8 DECKING <br />2x4 THRUST 1x RISERS (TYP.) / / 7 <br />00 BLOCK r / 2x6 LANDING <br />(3) 2x12 I / 60 <br />6 2x4 FRAMING <br />STRINGERS 42" KNEE WALL WITH ,( // 5 <br />3/4" PLYWOOD 1x8 CAP & CASING OR `� 4 <br />DECKING 36" RAILING 3 <br />ih 2x6 LANDING 2x4 THRUST 2 <br />BLOCK <br />2x4 FRAMING 1 / <br />TYP. STAIR SECTION <br />STAIR CALCULATIONS: <br />TOTAL RISE = 10'-0 3/4" <br />(16) RISERS AT 7 -9/16" <br />10" TREADS w/ 3/4" NOSING <br />Stairway construction shall conform to the FBC Residential 6th Edition (2017) sections R311.7, R312 and R302.7. <br />Riser height: <br />The riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading edges of the <br />adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Tread depth: <br />The tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the vertical planes of <br />the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The greatest tread depth within any <br />flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Winders: <br />Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the foremost <br />projection of adjacent treads at the intersections with the walkline. Winder treads shall have a tread depth of not less than 6 <br />inches at any point within the clear width of the stair. <br />Nosings: <br />The radius of curvature at the nosing shall be not greater than 9/16 inch. A nosing projection not less than 3/4 inch and not <br />more than 11/4 inches shall be provided on stairways with solid risers. The greatest nosing projection shall not exceed the <br />smallest nosing projection by more than 3/8 inch between two stories, including the nosing at the level of floors and landings. <br />Beveling of nosings shall not exceed 1/2 inch. <br />Handrails: <br />Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more risers. Handrail <br />height measured vertically from the sloped plane adjoining the tread nosing, or finish surface of ramp slope, shall be not less <br />than 34 inches and not more than 38 inches. Handrails for stairways shall be continuous for the full length of the flight, from a <br />point directly above the top riser of the flight to a point directly above the lowest riser of the flight. Handrail ends shall be <br />returned or shall terminate in newel posts or safety terminals. Handrails adjacent to a wall shall have a space of not less than <br />1/2 inches between the wall and the handrails. <br />Grip -size: <br />Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater than 2 inches <br />r provide equivalent grasp -ability in compliance with Section R311.7.8.3. <br />Guards: <br />Guards shall be located along open -sided walking surfaces, including stairs, ramps and landings, that are located more than 30 <br />Inches measured vertically to the floor or grade below at any point within 24 inches horizontally to the edge of the open side. <br />Required guards at open -sided walking surfaces, including stairs, porches, balconies or landings, shall be not less than 36 <br />nches in height as measured vertically above the adjacent walking surface or the line connecting the leading edges of the <br />reads. Required guards shall not have openings from the walking surface to the required guard height that allow passage of a <br />sphere 4 inches in diameter. <br />nder-stair protection: <br />nclosed accessible space under stairs shall have walls, under -stair surface and any soffits protected on the enclosed side <br />ith 1/2-inch gypsum board. <br />SEE PLAN FOR LANDING DEPTH r <br />MIN. (3) 2x STUDS R <br />@ END OF LANDINC <br />BELOW HDR. BEAM <br />STANDARD (3) 2xl <br />STRINGERS w/ <br />SIMPSON A35/USP <br />MP34 CLIP TO <br />FLOOR SYSTEM O' <br />LANDING FRAMING <br />(2) 2x HDR. <br />REQ'D @ ENC <br />LANDING FOF <br />STRINGERS" <br />CONNECT TC <br />PLY SHEATHING OVER <br />LANDING ATTACHED PER <br />GENERAL FLOOR <br />CONSTRUCTION NOTES <br />2x8 #2 SYP JOISTS @ LANDING <br />@ 16"O.C. w/ SIMPSON A35/USP <br />MP34 OR LUS26 HANGER ON <br />EA. SIDE <br />MASONRY OR WOOD WALL, <br />SEE PLAN <br />2x8 #2 SYP (P.T. IF MASONRY <br />WALL) CONTINUOUS LEDGER <br />w/ (3) 16d NAILS @ 16" O.C. MAX. <br />TO EA. STUD. ((2) 1/4"X3 1/2" <br />TITENS @ 16" O.C. MAX. FOR <br />MASONRY WALL) <br />GENERAL LANDING FRAMING INFO. <br />SCALE: N.T.S. <br />9'-0" MAX LANDING LENGTH <br />CONT. HANDRAIL <br />RETURN TO <br />WALL DETAIL B SCALE: NTS <br />25'-0" <br />2'4" 16'-1 " 1. 6-7" <br />2x4 #2 SPF STUDS @ 16" 1 <br />O.C. TYP. @ 2nd FLOOR OW (kI <br />O6 1. U ) H1 D2 <br />EXTERIOR WALLS <br />1/2 33 SH TYP S <br />TEMP D2 (EGRESS CORNERS <br />o OF2'- <br />in <br />I <br />� RB P I " <br />w= SPECS. I <br />-j = 4'-4 &D 5'-6" o <br />I <br />a�Jih <br />wZZ I �O BATH 3 <br />D2 <br />H O Y A l l 8' 0" FLAT CLG SMSTAM36IM. w/ 1 <br />TILE R/SH o G-( ) <br />'-'-'-'-' <br />48x42 - � - - - �" <br />3 RECESS TB iv @ BASE <br />D2 SHOWERi <br />7'-0" 2-3'-�- 12'-10" <br />SIM. w/ (1) TILE TO V�� <br />I I 36" x 22" <br />MSTAM36 T A. .F. I I I ATTIC <br />@BASE �i L___' -- ACCESS OWNER'S <br />co in WV <br />N fV 8'-0" F T CLG in SUITE <br />04 C RPET <br />TIP I 2468 8'-0" FLAT CLG <br />CARPET ;n <br />N <br />N <br />4068 <br />B.F. <br />00 <br />o <br />BEDROOM 2 ---- R/SH <br />8'-0" FLAT CLG - <br />CARPET <br />ran 12'-2" 4'-8" 4" T-6" <br />6 =w <br />o D2 N w 19 M <br />LO <br />H1 O <br />^� 5068 (2668 42" H 1/2 WALL I 16 v <br />B.F. OR RAILING PER 15 <br />SPECS 1 <br />J 1 14 <br />6- - - - - - - - - - - - - - - U CO 1 6 <br />TYP. 2 R/SH " I 13 � D2 <br />STORY. SEE a, I 12 "= <br />JJ/S6 FOR0 <br />o 00 TECH I 11 OC H1 <br />STEMWALL ° ° CENTER <br />OPT. I <br />r 1 10 <br />5_7" 3'4" L 6-8" T-3" 19 T-11" <br />I LE TO ]BATH s 1 8 1 <br />' A.F.F. 8'-0" FLAT C ��, I L1 <br />TILE P 2868 7 <br />I 6 <br />I <br />co 1 3 <br />C° D2 <br />N <br />N 1 2 3 4 5 SIM. w/ (1) <br />6� MSTAM36 <br />�`O @BASE <br />D2 BEDROOM 3 4-SH N N r <br />N <br />SIM. wl 1 8'-0" FLAT CLG o� <br />MSTAM36 <br />CARPET G.T. <br />@ BASE <br />11'-6"- _ - _ 12 -4-111'-2" <br />11 <br />G.T- <br />Sim. w/(1) ----- = I - 00 o------- <br />MSTAM36 OI a I . rri <br />@ BASE BEDROOM 4 r3 <br />3 ( 8'-0" FLAT CLG D2 <br />D2 G T CARPET SIM. w/ (1) <br />MSTAM36 <br />00 <br />@ BASE <br />1/2 33 SH m I v <br />Y I 6 B H1 I <br />25-SH 25-SH <br />9 EGRESS 9 <br />D2 EGRES <br />B H1 2D1 D2 O H1 <br />I <br />L---------- <br />2-10" 2'-10" 2'-11" 13'-6" <br />5'-8" 19'-4" <br />I 25-0" <br />I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />L- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -.- J <br />REVISION NOTES 12/17/2009: <br />1. ALL CLOSETS THAT ARE NOT WALK-IN CLOSETS <br />ARE TO BE FRAMED DOWN TO 8'-0" A.F.F. <br />2. ALL BLOCK WALL FURRING IS TO BE 24" O.C. <br />EXCEPT IN WET AREAS. SPACE WET AREA <br />FURRING AT 16" O.C. <br />3. NO RECESSES FOR SHOWERS. SHOWERS ARE <br />TO BE PANNED WITH A PRE-FAB. BASE. <br />4. ALL VANITY HEIGHTS ARE 36" A.F.F. <br />5. SLIDING GLASS DOORS ARE TO HAVE A 1-1/2" <br />RECESS. REFER TO MASON'S SCOPE FOR <br />RECESS WIDTH. <br />6. ALL BATHROOMS HAVE ONE MEDICINE CABINET <br />7. ALL 50' PLANS. FRAME BAR TOP AT 40-1/2" A.F.F. <br />8. ALL TUB DECKS ARE SIZED AS FOLLOWS; <br />40' PRODUCT LINE - MIN. 48" x 64" <br />50' PRODUCT LINE - MIN. 48" x 76" <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H 1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) - 1 3/4" X 9 114" <br />LVL 2.0E Fb=2950 <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2950 <br />(2) - 2X4 #2 SYP W/ 1/2" <br />Follow Q/S4. See Plan for <br />RAG <br />FLITCH PLATE <br />Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />OPENING PRESSURES <br />ENCLOSED-EXPOSURE"C" <br />0 <br />+29.7 / -32.2 <br />© <br />+29.7 / -39.7 <br />© <br />+28.3 / -30.8 <br />OD <br />+28.3 / -37.0 <br />�E <br />+26.6 / -29.1 <br />OF <br />+26.6 / -33.5 <br />GG <br />SEE SIN SHEET OH SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />1 +29.7 / -39.7 <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20X26 <br />182X25' <br />S.H. <br />13 <br />20X383 <br />18JX37 <br />S.H. <br />14 <br />20 X 50 g <br />18 � X 50 <br />S.H. <br />15 <br />20X63 <br />18JX62 <br />S.H. <br />16 <br />20X72 <br />182X71 <br />S.H. <br />1H2 <br />271/4X26 <br />26X25 <br />S.H. <br />iH3 <br />271/4X38g <br />26x374 <br />S.H. <br />1 H4 <br />27 4 X 50 1 <br />26 x 50 <br />S.H. <br />1115 <br />27 4 X 63 <br />26 X 62 1/2 <br />S.H. <br />1H6 <br />274X72 <br />26X711/2 <br />S.H. <br />22 <br />37 X 26 <br />36 J X 25 112 <br />S.H. <br />23 <br />37 X 38 a <br />361 X 37 3/4 <br />S.H. <br />24 <br />37 Ja X 501 <br />36 1 X 50 <br />S.H. <br />25 <br />37 a X 63 <br />36 2' X 62 112 <br />S.H. <br />26 <br />37 J X 72 <br />36 z X 71 1/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 � WIDE <br />S.H. <br />32 <br />54 X 26 <br />5212 X 25 <br />S.H. <br />33 <br />54 X 38 8 <br />52 12X 37 <br />S.H. <br />34 <br />54 X 50' <br />521 X 50 <br />S.H. <br />35 <br />54 X 63 <br />5212 X 621 <br />S.H. <br />36 <br />54 X 72 <br />5212 X 71 <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or class duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501A7.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic , crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />MASONRY HGT. @ 8'-0" A.F.F. <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO <br />UPLIFT CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />FIRST FLOOR LIVING AREA 952 S.F. <br />SECOND FLOOR LIVING AREA 1121 S.F. <br />TOTAL LIVING AREA <br />2073 S.F. <br />GARAGE <br />396 S.F. <br />LANAI <br />104 S. F. <br />ENTRY <br />32 S.F. <br />TOTAL SQ. FT. <br />2605 S.F. <br />INSULATION REQ. <br />LOCATION <br />R-VALUE / TYPE <br />EXT CONC WALL <br />R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 <br />R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 <br />R-19 KRAFT FACED <br />CONDITIONED CEILING <br />R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION <br />R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />SECOND FLOOR PLAN - ELEV-13 <br />SCALE: Y4"=V-0" <br />is <br />N t� <br />r u. <br />>. E <br />rr � <br /><o � <br />= E <br />_ <br />a. <br />M <br />N <br />0 <br />N <br />0 <br />0 <br />.<t:.vel4i <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code <br />- <br />Residential 7th Edition. Engineer's signature and seal <br />is only for <br />the structural engineering portions <br />of the drawing pages bearing <br />Engineer's signature and seal. <br />N <br />W <br />Q <br />v E 9 N <br />0 0 8 N� <br />V <br />N O <br />0 <br />��T 00 ae LL <br />�{NMv� LL <br />Mi <br />a <br />a a <br />@�i� a <br />Z <br />Z <br />Z <br />�rn <br />ii <br />r2o o 0 <br />;NN c0 m j Q <br />W <br />rn�O'� m <br />o w <br />LL^ <br />0 <br />N M Z Y!1 H <br />;Z <br />o d ❑a❑ <br />Z <br />W <br />z N <br />z <br />Q <br />V) <br />2 <br />Z v <br />� o <br />o <br />r <br />O w <br />V) c <br />W J <br />® <br />U � H <br />53 <br />-O <br />c <br />Q N � <br />sm <br />0 <br />Z <br />M <br />J <br />Z � <br />� <br />E <br />>n <br /><N <br />a p; <br />E <br />� U! <br />sz <br />z a <br />2 <br />H N <br />g <br />pz�¢ <br />D <br />Z <br />o� <br />W ti <br />wg <br />Z <br />w= <br />O <br />cn c <br />QI <br />a o <br />< <br />m 0 <br />o° <br />Zr <br />Z <br />m v <br />JI <br />,2 <br />�m <br />>Z <br />�m <br />g <br />0� <br />go <br />W <br />yy4 <br />C. <br /><� <br />0 <br />2 <br />3 <br />o <br />w <br />w ¢ <br />C� <br />-0 <br />t� <br />v <br />olQ <br />a <br />o � <br />0 <br />2O <br />= <br />>co <br />Ocm <br />0 <br />C:) <br />LO <br />N <br />o <br />L0 <br />�-. <br />Q <br />° <br />N <br />�� <br />m <br />N <br />�- <br />O <br />LO <br />O <br />LIL <br />r*,- <br />-lc <br />m 04 <br />0) <br />N <br />N <br />r <br />Q <br />LO <br />E <br />c <br />Z <br />Z <br />E T <br />m <br />m <br />0- <br />E <br />U -1 <br />v <br />Q <br />c <br />c <br />JOB <br />NO: <br />23-03652 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />1.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.