My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6750 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6750 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2025 10:45:14 AM
Creation date
2/19/2025 8:26:29 AM
Metadata
Fields
Template:
Building Plans
Street #
6750
Location
Back Forty Lp
Contractor
Lennar Home
Building Plans - Permit #
6303
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI LIL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11.In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W P <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />I� <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />FO <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />-� <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUST FAN <br />�+ <br />EXHAUST FAN/LIGHT COMBINATION <br />�D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />�BD <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />a <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />TV <br />TELEVISION (OPTIONAL) <br />a 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />/I] <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />L J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />r J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />150A/200A INDOOR <br />PANEL CENTER <br />#14 to lights & outlets <br />NEMA 1 #12 to appliances and GFI <br />150 AMP/ <br />200 AMP 01 #10 to WH <br />10 #8 to Range <br />10 #6 to HVAC <br />MAIN -,+ <br />150=2/0 <br />200=4/0 in 2" Conduit <br />200 amp <br />150 amp IT <br />UNDERGROUND Disconfe <br />SERVICE BY POWER CO. <br />INTERSYSTEM 4 Bare Cu Ground <br />BONDING o 4 GROUNDING WIRE <br />TERMINATION PER �I WITH CODE APPROVED <br />NEC 17, 250.94- CLAMP PER 250,50 AND <br />250.52 OF THE 2017 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />1.5" VTR <br />lit^ <br />I <br />I <br />III 3" VTR <br />I � � <br /><� I I <br />1" VTR <br />3" <br />W <br />SWITCH FOR <br />DISPOSAL <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />PW <br />KITCHEN <br />DEDICATED <br />RECEPTACLE FOR <br />CROWAVE RANGE <br />HOOD PER SPECS <br />A/C PAD <br />GFI WID DISC. <br />�PIB <br />/ I <br />I <br />�ENTRY <br />�P <br />DB & GFI TO GFI <br />BE ALIGNED - - - - - - - <br />VERTICALL <br />I <br />I <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS <br />COACH LIGHTS COACH LIGHTS <br />OR PREWIRE AS / OR PREWIRE AS <br />PER SPECS / PER SPECS <br />SPEC 3 & 4 KITCHEN FIRST FLOOR ELECTRICAL PLAN - ELEV-B <br />SCALE: 1/4"=V-0" <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />I I I <br />I I I <br />I I I <br />I I I <br />I I I <br />L- - - - - - - - - - I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />1 I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />1 I <br />I I <br />L----------------------------------------I <br />SECOND FLOOR ELECTRICAL PLAN <br />ELEV-B <br />CV <br />GV <br />a <br />Cam' <br />O <br />�- <br />oY <br />5- <br />3 � <br />n+ <br />�7 <br />E <br />a ,-. <br />.a U <br />M <br />O <br />CV <br />o_ <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code <br />- <br />Residential 7th Edition. Engineers signature and seal <br />is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />F <br />a <br />0 E S gN <br />o In 8 '0 <br />N_pp <br />I+ <br />y <br />0 <br />co r n J <br />co LL <br />di <br />rn r r �? LL W <br />M <br />a <br />��v w ° wa <br />LL a he <br />Z <br />J LL z <br />p 0 <br />m c� <br />t cco O <br />O <br />Tj .�N GO m L Q <br />Q K <br />LLW <br />10 w <br />LO (h Z U <br />N u H <br />O U ❑❑❑ <br />Z <br />W <br />V M � <br />N O <br />O <br />Z 00 <br />I QNQ <br />Q <br />O <br />N <br />M <br />Z v <br />C-1 <br />AQ) <br />� <br />w <br />O <br />U <br />g <br />0 <br />w $ <br />Ly N <br />tNt ^ <br />v' <br />� <br />LD .-. <br />U d <br />w <br />° <br />U 'o <br />N <br />sm <br />� <br />0 <br />CO <br />Z <br />Z <br />M <br />J <br />¢ <br />Z <br />E <br />LL <br />p <br />za <br />>ry <br />an <br />a <br />E <br />� <br />0� <br />z® <br />LliQ <br />O E <br />aZ <br />.o <br />Ott <br />a <br />aZ <br />COro <br /><o <br />mo <br />J1 <br />01 <br />CID'SI <br />¢ <br />2� <br />ZZ <br />go <br />aw <br />Ww <br />o <br />m <br />LL <br />o� <br />ch <br />R <br />a r= <br />O- <br />3 <br />O <br />N <br />>M <br />of <br />m <br />M <br />0 <br />L <br />O <br />co � <br />N <br />CL <br />U')^ <br />Q <br />Ct '4 <br />� o <br />LL <br />tp <br />N <br />+� <br />O <br />Ln <br />O <br />LL <br />Yr__ <br />co <br />N <br />N <br />N <br />Q <br />LO <br />n LO <br />r <br />Ew <br />E <br />c <br />co <br />o <br />Z <br />ro <br />Z <br />E T <br />N <br />� <br />c <br />ca <br />U <br />v :? <br />16 <br />c <br />a <br />_j <br />Q <br />JOB <br />NO: <br />23-03652 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.