4- <br />I <br />INDEX OF DRAWINGS <br />SHEET DESCRIPTION <br />SHEET <br />No. <br />CS COVER SHEET <br />1.1 FIRST FLOOR PLAN <br />1.2 SECOND FLOOR PLAN <br />2.1 EXTERIOR ELEVATIONS <br />2.2 EXTERIOR ELEVATIONS <br />3 ELECTRICAL PLAN <br />4 ROOF PLAN <br />5 FOUNDATION PLAN <br />6.1 FIRST FRAMING PLAN <br />6.2 SECOND ROOF FRAMING PLAN <br />ABBREVIATIONS 7 -LINTEL PLAN AND -DETAILS <br />SN STRUCTURAL <br />AB or A.B. Anchor Bolt FIX or FXD Fixed RA or R/A or R.A. Return Air SN1 DETAILS <br />ABV or Abv. Above FLR or Fir. Floor RAD or Rad. Radius <br />AC or A/C Air -Conditioner FUR SYS or Fir Sys Floor System RAG or Rag. Return Air Grill S3 DETAILS <br />ADJ or ADJ. Adjustable FOM or F.O.M. Face Of Masonry REC or Rec. Recessed <br />AFF or A. F.F. Above Finished Floor FP or F.P. Fireplace RECEPT Receptacle S4 -DETAILS <br />AHU or A.H.U. Air Handler Unit FR DR French Door REF or Ref. Refrigerator S5 DETAILS <br />AL T or ALT. Alternate FRT Front REINF Reinforcing <br />BC Base Cabinet FT or Ft. Foot/ Feet REQD or Req'd. Required S6 DETAILS <br />BF Bifold Door FTG or Ftg. Footing RM or Rm. Room ST STAIR DETAILS <br />BK SH or Bk Sh BookShelf FXD GL Fixed Glass RND or Rnd. Round <br />BILK or BILK. Block GALV or Galv. Galvanized RO or R.O. Rough Opening SS RETROFIT DETAILS <br />BLW or BLW. Below GC or G.C. General Contractor RS, RIS, R/SH or R&S Rod and Shelf D1 SECTIONS & DETAILS <br />BM or Bm. Beam GFI or G.F.I. Ground Fault Interrupter SC Solid Core <br />BOT or Bot. Bottom GT or G.T. Girder Truss SD or SD. Smoke Detector D2 SECTIONS & DETAILS <br />BP or B.P. Bypass (door) GYP BD or Gyp. Bd. Gypsum Board SGD Sliding Glass Door WIP ­ WATER - PROOFING , . DETAILS <br />BRG or BRG. Bearing HB Hose Bibb SH or Sh. Shelves <br />C Carpet HC Hollow Core SHT Sheet PA1.0 PRODUCT APPROVAL NUMBERS <br />CAB Cabinet HDR or. Hdr. Header SHWR or Shwr. Shower <br />CIR or Cir. Circle HGT or Hgt. Height SL or S.L. Side Lights PA1.1 PRODUCT , - APPROVAL NUMBERS <br />CJ or C/J Control Joint HH or H.H. Hand Held (plumbing faucet) SPECS or SPECS. Specifications PA1.2 PRODUCT APPROVAL NUMBERS <br />CLG or Cig. Ceiling HORIZ Horizontal SPF or S.P.F. Spruce Pine Fir — — — — — — — — — — — — — — — — — — — — — — — — — -- — — — — — — — — — — — — — — — — — - <br />CIMU Concrete Masonry Unit HS Hard Surface (flooring) SQ FT or SF or S.F. Square Foot (feet) PA1.3 PRODUCT APPROVAL NUMBERS <br />COFF or Coff. Coffered or Tray Ceiling ILO In Lieu Of SQ or Sq. Square sH1.0 _HukmcmE SHUTTER PRODUCT APPROVAL <br />COL or Col. Column INSUL or Insul. Insulation STO Storage <br />COMM or Comm, Community INT or Int. Interior SW or S.W. Shear Wall SH1.1 HURRICANE SHUTTER PRODUCT APPROVAL <br />COMP or Comp. Compressor KNVALL or K/Wall Kneewall SYP or S.Y.P. Southern Yellow Pine <br />SH1.2 HURRICANE SHUTTER PRODUCT APPROVAL <br />CONN or CONN. Connection KS or K.S. Knee Space TB Towel Bar H - HURRICANE sHufTLk PRODUCT APPROVAL <br />CONT or Cont. Continuous LAUN or Laun. Laundry TEMP or Temp. Tempered s 1.3 <br />CSMT Casement LAV or Lay. Lavatory THIKN or Thik'n, Thicken -HURRICANE SHUTTER PRODUCT APPROVAL <br />CT or C.T. Ceramic Tile LF or L.F. Linear Ft. TOB or T.O.B. Top of Block ', SH1.4 <br />D or D. Dryer LL Lintel Length TOM or T.O.M. Top of Masonry Fill SH1.5- HURRICANE PRODUCT APPROVAL <br />DB Door Bell LT Laundry Tub TOP or T.O. P. Top of Plate uU FLT <br />DBIL or Dbl. Double MAS or Mas. Masonry TP Toilet Paper Holder <br />0 <br />DCF Decorative Cementitious Finish MAX or Max Maximum TR Towel Ring <br />DEC or Dec. Decorative MC Medicine Cabinet TRANS WDW or Trans, Transom Window OC]OC�000 <br />DIED or Ded. Dedicated (outlet) MFR or Mfr. Manufacturer TYP or Typ. Typical <br />DIA or Dia. Diameter MGT Management (room) LIC or u.c. Under Counter <br />DISP or Disp. Disposal MIN or Min Minimum UCL Under Cabinet Lighting <br />DIST or Dist. Distance MIR or Mir. Mirror U NO or U.N.O. Unless Noted Otherwise <br />DMF Decorative Masonry Finish MIL or M.L. Microlam V or v. Valve (shower or tub/shower) <br />DS or D.S. Drawer Stack MONO or Mono Monolithic VB Vanity Base <br />1:71 E71 El El 71 [71:171 __ - __ <br />DTL Detail MW or MICRO or Micro. Microwave VERT or Vert. Vertical <br />DV or D.V. Dryer Vent NTS or N.T.S. Not to Scale VIL or V.L. Versalam <br />DVP or D.V.P. Diverter Valve (plumbing) OE or O.E. Owner's Entry VTR or VTE Vent through Roof / Exterior <br />DW or D.W. Dishwasher OPNG or Opn'g. Opening Worw Washer MEAN ROOF 15 FT. HIGH TYPICAL <br />EA or Ea. Each OPT or Opt. Optional W1 or w/ With <br />ELEC or Elec. Electrical PC Pull Chain WA or W.A. Wedge Anchor FOR SINGLE STORY HOMES <br />ELEV or Elev. Elevation FED or Ped. Pedestal WC or W/C or W.C. Water Closet (toilet) <br />EQ Equal PH Phone WD or Wd Wood MEAN ROOF 30 FT. HIGH TYPICAL <br />EW or E.W. Each Way PKT or Pkt. Pocket (Door) WDVV HDR or WDW, HDR. Window Header FOR 2 STORY HOMES <br />EXP or Exp. Expansion PL or P.L. Parallam WH or W. H. Water Heater <br />EXT or Ext. Exterior PLIF Pounds per linear foot WIC or W.I.C. Walk-in Closet THIS DRAWING AND DESIGN IS VALID <br />FBC Florida Building Code PLNT SHLIF or Pit. Sh. Plant Shelf WIM or W.M. Wall Mounted (plumbing fixture) FOR 12 MONTHS AFTER THE DATE IT <br />FDN or Fdn. Foundation PILT HT or Pit. Ht. Plate Height WIP Water Proof(ing) IS SIGNED AND SEALED OR WHILE <br />FFB Finsh Floor Break PSF Pounds per square foot WS Water Softener CURRENT CODE IS VALID <br />FG Fiberglass (Shower Pan) PT or P.T. Pressure Treated WWF Welded Wire Fabric (Mesh) <br />FIN Finished PW or P.W. Pre -wire CODE REFERENCES ARE SUMMARIES <br />FIN FLR or FF or Fin. Flr. Finished Floor PWDR or Pwd. Powder Room REV. 06.23.22 OF CODE SECTIONS. <br />SEE FBCR (CURRENT VERSION) FOR <br />PLAN REVISIONS COMPLETE CODE INFORMATION. <br />DATE VERSION DESCRIPTION Notice to Builder & All Subcontractors <br />It is the intent of Designer/Engineer listed in the titleblock of these <br />04/25/12 1.0 NEW BASE PLAN documents that these documents be accurate, providing Licensed <br />Professionals clear information. Every attempt has been made to <br />prevent error. The Builder and all subcontractors are required to <br />review all the information contained in these documents, prior to <br />06/25/12 2.0 GRADE BEAM FOUNDATION the commencement of any work. The Designer/Engineer are not <br />responsible for any plan errors, omissions,or misinterpretations <br />undetected and not reported to the Designer / Engineer prior to <br />08/11/15 3.0 2015 NEW CODE UPDATE construction. All construction MUST be in accordance to the <br />information found in these documents. Any questions regarding <br />FBC 2017 CODE UPDATES & MODEL the information found in these plans should be directed to our <br />03/06/18 4.0 Office at (407) 880-2333 immediately. No backcharges will be <br />UPDATES considered for reimbursement by the Designer/Engineer without <br />REVISED SGD, LANAI & WINDOWS advanced notification and approval by the Designer/Engineer, <br />06/01/18 4.1 <br />Payments will be made in accordance to the terms of the <br />AT REAR agreement. <br />06/07/18 4.2 REVISED DINING WINDOW TO 35-SH Control of Construction Site <br />The Designer/Architect and engineer of record (EOR) have no <br />control over the construction site and shall not be responsible in <br />any manner for control of the construction site including, but not <br />12/19/20 5.0 FBC 2020 CODE UPDATE limited to, scheduling and sequencing of work, jobsite safety, and <br />ventilation of the building and thereby shall not be responsible for <br />the indoor air quality, or the effects thereof, for any reason <br />whatsoever. The Designer/Architect and FOR has no duty to <br />1E r protect, without limitation, the residence, construction site, <br />materials, or equipment, from moisture, mold, fungus, fire, theft, <br />vandalism, trespass, or any other peril or condition, at any time, <br />expressly including, but not limited to, the period of time before <br />construction, during the construction of the project, or after <br />construction and the Designer/Architect and FOR has no duty to <br />take any action or preventive measures to protect such property <br />against any such peril at any time for any reason. <br />Care and Maintenance <br />Yearly maintenance and inspections by the builder/homeowner <br />are necessary for the future life of this home. Care must be taken <br />to check windows and doors for caulking, remove leaves and <br />debris off roofs, make sure that water flow is away from the <br />house and have your home repainted every 3 - 5 years to protect <br />1763 the coatings. The designer and engineer of record are not <br />responsible for the upkeep of the home and will not be held <br />liable for instances that may occur over the normal life of the <br />home without proper maintenance, <br />M <br />40*J <br />% (D -0 <br />CD <br />CL <br />W -0 C14 <br />E <br />C= <br />Co <br />CIO <br />V_ <br />E <br />0 <br />18. <br />P <br />Cl> <br />cli <br />C=) <br />cli <br />....... .... <br />c <br />NO P,'-"-' '7�_' <br />ST <br />V, <br />We <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and sea[. <br />in <br />W <br />AAh 11- C, E S <br />8 c,4 <br />.0 0, <br />. 6 <br />C'4 C5 <br />, C <br />0 T,LL <br />u- <br />'Z <br />04 0 <br />U_ CD Z <br />0 <br />Z my 0 <br />Lu <br />C� 2W <br />0 <br />05 <br />W <br />Z LO <br />CC) IL Z <br />a N < <br />Z <br />W <br />CD Cq !R <br />0o <br />c) <br />< < <br />V) <br />CD <br />WCn <br />3 <br />0 <br />LU <br />V) 04 <br />V) A§ <br />U) <br />W <br />Sk- <br />E <br />U3 4, <br />< �0 0 <br />CC) <br />cll'� <br />Z <br />ZE <br />_JOZ <br />LL_ <br />c6- E <br />CL 0 <br />E V <br />'Z <br />Z< <br />K <br />a <br />Q <br />< 5 <br />2 <br />R <br />. <br />00 <br />.0 <br />E <br />0." <br />00 <br />Cf.) <br />_C3 <br />Z <Z <br />0, <br />Z <br />Z <br />gZz <br />o <br />W <br /><'0 . <br />M <br />MillV0, <br />0 <br />.0 C) <br />0) <br />LO <br />co Lr) <br />C) <br />N CL <br />LO <br />< <br />0 <br />cr 0 <br />CN <br />U) <br />M <br />0 <br />LO <br />ILL <br />0 <br />00 <br />-id <br />U C10 <br />C) <br />(.0 <br />co <br />M C'4 <br />0) <br />b <br />L0 <br />00 N <br />< V) <br />r- LO <br />E <br />2:1 r.0 Nt <br />0) <br />0 <br />Z <br />Z <br />E <br />12- <br />Eai <br />0 ca <br />U < 0 <br />0) <br />JOB <br />NO: 23-03651 <br />SCALE : AS NOTED <br />SHEET NO. <br />CS <br />