6758 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6758 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 6:21:54 PM
Creation date
2/19/2025 8:27:05 AM
Metadata
Fields
Template:
Building Plans
Street #
6758
Location
Back Forty Lp
Contractor
Lennar Home
Building Plans - Permit #
6301
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SIN <br />CONT. HANDRAIL <br />RETURN TO. <br />i- WALL DETAIL <br />A) SCALE: NTS <br />STAIR CALCULATIONS: <br />TOTAL RISE = 10'-0 3/411 <br />(16) RISERS AT 7 -9/1611 <br />10" TREADS w/ 3/4" NOSING <br />140C <br />REV 10.1.20 CAB <br />EXTERIOR 2ND FLOOR <br />BEARING WALL SCHEDULE <br />HEIGHT <br />STUD <br />SPECIES <br />SPACING <br />SPF #2 <br />8'-0" <br />2x4 <br />SYP #2 <br />16" O.C. <br />SPF #2 <br />9'-0" <br />2x4 <br />SYP #2 <br />16" O.C. <br />SPF #2 <br />>9'-0" <br />2x6 <br />SYP #2 <br />16" O.C. <br />* WHEN THE TOP OF WALL IS GREATER THAN T-0", THEN AT <br />EACH EXTERIOR CORNER WITHIN THE 4'-0" END ZONE, THE <br />STUDS WILL BE DOUBLE STUDS @ 16" O.C. OR SINGLE STUDS <br />@ 12" O.C.* <br />THIS IS ONLY USED WITH PLASTER OR STUCCO EXTERIOR <br />FINISH <br />** WALL SHEATHING 15/32" EXPOSURE 1 OR EQUIVALENT. <br />REFER TO SHEATHING SCHEDULE FOR ATTACHMENTS- <br />F- - - - - - - - - - - - - - - - - - - - 1 <br />A I 125'-0" <br />\ I I 8'-9" 3'-8" <br />I I <br />42" KNEE WALL WITH ; H1 I H1 <br />16 <br />1 x8 CAP & CASING TYP. @ D2 ; 12 O A TYPS6 D2 <br />3/4" PLYWOOD CORNERS I 125 H U.N.O.. 25 H <br />DECKING USP MP3 CLIP EA. EGRESS* EGRESS* <br />STRINGER TO BEAM/ ___ B 60"x36" <br />SHOWER <br />FLOOR SYSTEM TYP. FIBERGLASS <br />C`Mld 16 -- O- -- SURROUND <br />P! \ TOWNER'S <br />T 15\\\ 36" H. CONT. _ ° 5 SUITE <br />I <br />\ 0) 8'-0" FLAT CLG. <br />M -- ! B T - <br />\ 6 = 268 CARPET <br />14 \\ GRASPABLE , H1 r <br />FLOOR - D2 <br />SYSTEM 13vvv I o�AT. <br />o RAILING 1 �aB Ti�E� G.T.50 <br />I O <br />v v M I IT I as '-10" 33 - - - 16-8'- f - - <br />12 v v I 4-SH <br />\ I <br />11 10" I _____ _____ <br />I R&S <br />3 \i <br />1x TREAD 10 i = 42" KNEE D2 rWIC <br />Mid \\ I SIM. W/ (1) 8t 0" FLAT CLG. <br />o (TYP.) 9 1 00 WALL WITH I CARPET = 2068 <br />MSTAM36 4"� <br />\ I 1 oD I r ACCESS, <br />� 1 x8 CAP & STRAPS @ � I '� _ n r! <br />r00STORAGE 8 \\ I CASING M BASE L----- <br />00 <br />UNDER 7 I _ °°---R&s--- <br />STAIRS I r <br />2x FRAMED 5\\\ ; TUB/SHWR MT-3- <br />TILETO7 -- BEDROOM 4 <br />WALL j A.F.F. O 8'-0" FLAT CLG. <br />4 \� 1X8 CAP & _ rn CARPET <br />1x RISERS -- BA 2' -00 <br />(TYP.) 3 CASING o-FLTCLG-8 <br />\ TB; Rv <br />ALL OR <br />2x FRAMED (3) 2x12 2 RAILING PER SPECS <br />iio ILL0 <br />WALL STRINGERS 1 <br />= TECH CENTER ILL <br />2x4 #2 SYP. P.T. THRUST BLOCK U) 7-9" 5'-11" 2668 11'-4" <br />W/(2)- 1/4 "x 3 1/2" TAPCONS @ H1 �D2 N 2668 <br />E-- ------ BF <br />16"o.c. AND 3" FROM EA. END. .. I ! ! ! <br />TYP. STAIR SECTION <br />SEE PLAN FOR LANDING DEPTH <br />MIN. (3) 2x STUDS R <br />@ END OF LANDINC <br />BELOW HDR. BEAM <br />STANDARD (3) 2x1. <br />STRINGERS w/ <br />SIMPSON A35/USP <br />MP34 CLIP TO <br />FLOOR SYSTEM O <br />LANDING FRAMINC <br />(2) 2x HDR. <br />REQ'D @ ENC <br />LANDING FOF <br />STRINGERS - <br />CONNECT TC <br />PLY SHEATHING OVER <br />LANDING ATTACHED PER <br />GENERAL FLOOR <br />CONSTRUCTION NOTES <br />2x8 #2 SYP JOISTS @ LANDING <br />@ 16"O.C. w/ SIMPSON A35/USP <br />MP34 OR LUS26 HANGER ON <br />EA. SIDE <br />MASONRY OR WOOD WALL, <br />SEE PLAN <br />2x8 #2 SYP (P.T. IF MASONRY <br />WALL) CONTINUOUS LEDGER <br />w/ (3) 16d NAILS @ 16" O.C. MAX. <br />TO EA. STUD. ((2) 1/4"X3 1/2" <br />TITENS @ 16" O.C. MAX. FOR <br />MASONRY WALL) <br />GENERAL LANDING FRAMING INFO._ <br />SCALE: N.T.S. 9'-0" MAX LANDING LENGTH <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H 1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1 /2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) - 1 3/4" X 9 1/4" <br />LVL 2.oE Fb=2950 <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.oE Fb=2950 <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.oE Fb=2950 <br />(2) - 2X4 #2 SYP W/ 1/2" <br />Follow Q/S4. See Plan for <br />RAG <br />FLITCH PLATE <br />Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />2x4 #2 SPF STUDS @ 16" <br />O.C. TYP. @ 2nd FLOOR <br />EXTERIOR WALLS <br />SIM. W/ (1) <br />MSTAM36 <br />STRAPS @ <br />BASE <br />OPENING PRESSURES <br />ENCLOSED-EXPOSURE"C" <br />AO <br />+29.7 / -32.2 <br />© <br />+29.7 / -39.7 <br />© <br />+28.3 / -30.8 <br />�D <br />+28.3 / -37.0 <br />UE <br />+26.6 / -29.1 <br />FO <br />+26.6 / -33.5 <br />GO <br />SEE SN SHEET HH SEE SN SHEET <br />6&140MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />1 +29.7 / -39.7 <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20X26 <br />18JX25 <br />S.H. <br />13 <br />20X383 <br />181X373 <br />S.H. <br />14 <br />20X505 <br />181X50 <br />S.H. <br />15 <br />20 X 63 <br />1812 X 62 2 <br />S.H. <br />16 <br />20X72 <br />1812X714 <br />S.H. <br />1112 <br />271/4X26 <br />26X252 <br />S.H. <br />1H3 <br />271/4X388 <br />26x37 <br />S.H. <br />1 H4 <br />27 a X 50 s <br />26 x 50 <br />S.H. <br />1H5 <br />274X63 t <br />26X621/2 <br />S.H. <br />1H6 <br />2711X72 <br />26X711/2 <br />S.H. <br />22 <br />37 a X 26 <br />361 X 25 1/2 <br />S.H. <br />23 <br />37 4 X 38 g <br />36 2 X 37 3/4 <br />S.H. <br />24 <br />37' X 501 <br />36' X 50 <br />S.H. <br />25 <br />37 a X 63 <br />36 ' X 62 1/2 <br />S.H. <br />26 <br />37 a X 72 <br />36 z X 71 1/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 2'WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 2 X 251 <br />S.H. <br />33 <br />54 X 38 g <br />52 � X 37 <br />S.H. <br />34 <br />54 X 50 g <br />52 2 X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 4 X 62 <br />S.H. <br />36 <br />54 X 72 <br />52 2'X 71 <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />Stair and Railing General Notes <br />Stairway construction shall conform to the FBC Residential 7th Edition (2020) sections R311.7, R312 <br />and R302.7. <br />Riser height: <br />The riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading <br />edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by <br />more than 3/8 inch. <br />Tread depth: <br />The tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the <br />vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The <br />greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Winders: <br />Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the <br />foremost projection of adjacent treads at the intersections with the walkline. Winder treads shall have a tread <br />depth of not less than 6 inches at any point within the clear width of the stair. <br />Nosings: <br />Nosings at treads, landings and floors of stairways shall have a radius of curvature at the nosing not greater than <br />9/16 inch or a bevel not exceeding '% inch. A nosing projection not less than 3/4 inch and not more than 1114 <br />inches shall be provided on stairways. The greatest nosing projection shall not exceed the smallest nosing <br />projection by more than 3/8 inch within a stairway. <br />Handrails: <br />Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more <br />risers. Handrail height measured vertically from the sloped plane adjoining the tread nosing, or finish surface of <br />ramp slope, shall be not less than 34 inches and not more than 38 inches. Handrails for stairways shall be <br />continuous for the full length of the flight, from a point directly above the top riser of the flight to a point directly <br />above the lowest riser of the flight. Handrail ends shall be returned or shall terminate in newel posts or safety <br />terminals. Handrails adjacent to a wall shall have a space of not less than 11/2 inches between the wall and the <br />handrails. <br />Grip -size: <br />Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater <br />than 2 inches or provide equivalent grasp -ability in compliance with Section R311.7.8.3. <br />Guards: <br />Guards shall be provided for those portions of open -sided walking surfaces, including stairs, ramps and landings, <br />that are located more than 30 inches measured vertically to the floor or grade below at any point within 24 inches <br />horizontally to the edge of the open side. Required guards at open -sided walking surfaces, including stairs, <br />porches, balconies or landings, shall be not less than 36 inches in height as measured vertically above the <br />adjacent walking surface or the line connecting the leading edges of the treads. Required guards shall not have <br />openings from the walking surface to the required guard height that allow passage of a sphere 4 inches in <br />diameter. <br />Under -stair protection: <br />Enclosed space under stairs that is accessed by a door or access panel shall have walls, under -stair surface and <br />any soffits protected on the enclosed side with 1/2-inch gypsum board. <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic, crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />MASONRY HGT. @ 8'-8" A.F.F. <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO <br />UPLIFT CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />FIRST LIVING 728 S.F. <br />SECOND LIVING 1036 S.F. <br />TOTAL LIVING 1764 S.F. <br />LANAI 60 S.F. <br />GARAGE 379 S.F. <br />ENTRY 62 S.F. <br />TOTAL SQ. FT. 2265 S.F. <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 R-19 KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />SECOND FLOOR PLAN -B <br />eery <br />C%�I <br />0 <br />a� U <br />UJ <br />ccvN <br />- � <br />W- <br />N R Q a- <br />'y <br />d <br />c r� <br />E <br />Co ca <br />0 <br />cL <br />0 <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code- <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />.Wsslot <br />EOo o <br />O <br />= <br />v <br />N U N <br />Y 6�' J <br />0 <br />_ <br />�M0 LL <br />M <br />Q <br />0_ a <br />wa <br />J LL u- <br />Z <br />Z <br />. 0 <br />L 7 <br />3 y� o <br />f6 r- t9 b] Q <br />9 W <br />p 'C� <br />W <br /><o26'O' � Z <br />Z <br />LL <br />w <br />N Z 4 x <br />_ <br />Z <br />N U U to F <br />O �Q❑ <br />Z <br />W <br />V M <br />N M <br />z � S <br />Z o <br />Q� <br />JJ <br />IU) <br />N <br />M <br />z _ <br />CV <br />C 0 <br />4-1 <br />W <br />Vm <br />0 <br />o <br />Ln <br />LU <br />[�_ <br />ONall <br />v <br />W <br />E <br />i <br />li <br />_ 'Ji <br />z <br />0 <br />Q o <br />N to <br />ti <br />o <br />CID <br />MJ <br />L <br />o <br />N <br />zo <br />a <br />N U <br />wz <br />Z© <br />oa <br />1 <br />no <br />wtt <br />oE <br />x0< <br />d=&Z <br />jo <br />O ( <br />co <br />ao <br />ow� <br />� L' <br />Gn <br />¢p <br />¢ <br />m� <br />�¢ <br />O U <br />u <br />O LL <br />m J <br />m <br />" <br />¢ w <br />Z Z <br />3 0 <br />CID <br />� < <br />WF <br />T <br />LO <br />wLL <br />¢o <br />oZ <br />�- <br />�3 <br />Jw <br />=F <br />o <br />M <br />wa <br />Yo <br />aF <br />_ <br />z¢ <br />0 <br />c Q <br />Lo <br />0 <br />m <br />0 <br />:3 N <br />o <br />L0 <br />^ <br />Cr <br />0N <br />� <br />U) <br />J <br />o <br />Ln <br />.� <br />a--+ <br />0 <br />� <br />o <br />CL) <br />co N <br />0) <br />00 o <br />LO <br />�-- <br />LO <br />�-- <br />nLO <br />E <br />C <br />f6 <br />Z <br />� <br />E O <br />m <br />N <br />E <br />C <br />it <br />U J <br />Q 0 <br />J <br />JOB <br />NO: <br />23-03651 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />1.2 <br />