Laserfiche WebLink
THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METAL LATH <br />16GAx1-1\2" LONG (3/4%1" CROWN) <br />STAPLES @ 6" O.C. VERT BETWEEN <br />STUDS (NOTED THUS:—) - OFFSET <br />STAPLES BETWEEN STUDS AS SHOWN <br />WALL SHEATHING <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking, <br />1/8" gap <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4) Place joists together and nail from each side with 2 rows of 10d nails <br />16GAxl-1/2" LONG (3/4"-1" 2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite <br />CROWN) STAPLES @ 6" OF THE JOIST ASA REQUIRED LEAVING Ys" GAP @ TOP sides by 6". <br />O.C. VERT INTO STUDS <br />(NOTED THUS:—) DOUBLE JOIST CONNECTION <br />METAL LATH ATTACHMENT DETAIL <br />REV. 09.24.21 SCALE: 3/4" = V-0" <br />*DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 703.7.1 LATH* <br />**ONLY APPLIES TO LENNAR TPA/JAX** <br />10'-0" <br />TANK -LESS W/H <br />CORNER OF <br />HOME H C G <br />GARAGE SIDE 0 0 0 <br />5'-0" - <br />STUB -OUT FOR Q o 0 <br />� <br />GAS METER 0 o <br />U <br />iV = <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />**ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />7'-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />1 SIMPSON HTS20 OR 3 16d TOENAILS <br />2" X 12" 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR 4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />'IT-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" orp <br />5000s 1.8/1.7 <br />net <br />wood panels <br />Two 3/4" wood panels or 2 x <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x — + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2x _ lumber <br />Double 2 x _ lumber <br />N.T.S <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />* Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />consideration. Check <br />wall or beam below.* <br />local building <br />1/16 <br />code for appropriate <br />details in1--or--20 <br />One 10d box <br />areas=20 of high <br />sinker <br />lateral load. <br />nail each side <br />at bearing. <br />- -11�) <br />Squash block / <br />(2x4 minimum) —/ <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />NO HOLES (EXCEPT <br />KNOCKOUTS) ALLOWED <br />IN BEARING ZONES —1 <br />DO NOT cut, notch <br />or drill flanges <br />Boise Joist Blocking <br />C Provide adequate bearing <br />for each lapped joist. <br />10dnails SECTION @ INT. BRG. WALL <br />N.T.S. <br />MINIMUM SPACING = 2x GREATEST <br />D DIMENSION OF LARGEST HOLE <br />(see table below) (KNOCKOUT EXEMPTS) D <br />(see table below) <br />FILL CELL STD. 90° HOOK F <br />BOND BEAM <br />SIMPSON MGT <br />w/(22)10d <br />w NAILS TYP. �GIRDERTRUSS <br />cr <br />STD. 900 CONT. #5 <br />BAR CONT. #5 I HOOK (� �r BAR r 2X TOP PLATE <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />v BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />T CONT. BASE PLATE <br />BEARING COLUMN SEE PLAN FOR REQ'D . `�,/—PLYWOOD FLOOR <br />COLUMN AND <br />fi �- Gy' i_.:::='' SHEATHING PER PLAN <br />I - <br />CONNECTION �TJI TO BE CUT TO ALLOW <br />� <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />1 INTERIOR BRG. WALL <br />TJI PER PLAN <br />1 OTHERWISE SOLID <br />/tBLOCKING TO MATCH <br />Solid block all posts from # OF 2nd FLOOR <br />above to bearing below. STUDS <br />SECTION @ INT. BRG. WALL <br />N.T.S. <br />1/8" min. )Small gap 2" min. <br />2" max. 4" max. — Web Stiffener Fastener Schedule <br />Joist Bearing Lo at— <br />i Series Depth End _Intermediate <br />9-1/2" 2-8d 24d <br />- BCl5000sP 11-7/8" 2-8d 3-8d <br />14" 2-8d 5-8-d <br />Clinch nails 9-1/2" 2-8d 2-8d <br />when Cl 6000s� � <br />11-7/8" 2-8d 3-8d <br />possible V BCI 6500s® 14" 2- 5-8d <br />V l 11 6-8d- <br />11-7/8" 2-8d3-8d� <br />-fill60s® 14" �2 8d 5-8d <br />Tight fit ----.— -- 16" 2-8d_ 6-8d <br />7/8" 3-13-16d ` 3-16d <br />2x4/Plywood/OSB web stiffener 2" min. gCl 90so �14-" 5-16d IL 5-16d � <br />required when indicated or 4" max. _ 16� 6-16d I 6-16d <br />- Hangers with side nailing. <br />- Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />- Birdsmouth cuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls: - for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />'1� blocking and wall or beam below.* <br />Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration. — <br />ISt UUI ANYVVIitrkt IN CANTILEVER <br />THE WEB. PROVIDE AT <br />LEAST 3" OF CLEARANCE <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Yz" <br />NOTES: <br />DO NOT CUT HOLES <br />LARGER THAN 1Y" <br />ROUNDIN <br />CANTILEVERS. <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. %" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />�When joists meet over wall, provide <br />1 3/4" minimum bearing for each. <br />Plumbing <br />Joist <br />I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S. <br />Backer block (12" wide min.) <br />Nail with 10-10d nails. <br />Install tight to top flange. <br />Joist hanger <br />\ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gap <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />h—I 4 requirements <br />0.6 X Joist <br />o .7 7 depth <br />OJ � <br />I -JOISTS BUCKETS <br />N.T.S. <br />5/8"0 <br />THRU <br />BOLT <br />I.0 <br />SIMPSC <br />wl (22) - <br />NAILS 1 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON META12 / <br />META12 TSS INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />SLEEVE THRU STEMS • <br />SEE PLAN FOR--'•• a .. <br />FOUNDATION INFO ` Q' <br />STEM FOUNDATION <br />GRADE <br />v <br />A/C CHASE 4" PVC <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />REINF. SEE PLAN <br />(2) #5 REBAR <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />- LOCATION OF <br />SECOND H10A <br />SIMPSON H10A ° • °' / (WHEN <br />w/ (18)10d x 1 1/2" REQUIRED) <br />NAILS�l <br />UPLIFT =1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />12" BELOW <br />GRADE <br />a <br />4 v <br />'d 4 v <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />a <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE VERTICAL THRU FND. <br />TOP (2) #5's x 4'4' <br />CENTERED @ PIPE <br />PENETRATION <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />4 •' o'4 a <br />�L �SA d <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION PLUMBING LINE <br />4 v141° <br />- — ° °o G <br />0 <br />a <br />4 <br />° ° <br />v <br />SEE FND. PLN. <br />SIZE & REINF. <br />N M <br />o =� _10 X <br />N i-L. Q_ <br />C N L <br />f <br />'S <br />LL Y t� <br />0 O <br />s :i t •� <br />U. <br />G� <br />z <br />1<4 <br />"'ritnC�P� <br />,~ <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residentlal 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />a <br />W <br />I- o <br />a N 8 <br />N <br />8O `' °° 9_ <br />l30 h r- S J <br />a J W W <br />U. <br />U. S a <br />W� rrn m <br />W <br />Z°"° � i d � <br />N <br />I IL <br />O U <br />rvii <br />W ❑D <br />U <br />z <br />z <br />a <br />(n <br />to z <br />C1 <br />CD <br />0M <br />N LL <br />O <br />Ln <br />�to <br />_U � <br />2 e <br />8 <br />_2 <br />U <br />*1 <br />M <br />N <br />_J <br />l► <br />g o <br />ZO <br />a_E <br />IT ni <br />�W <br />o o <br />1K <br />Z <br />Q <br />04 <br />4 <br />0:C, <br />�� <br />w <br />C <br />9 <br />O <br />o� <br />N c <br />z <br />fn <br />�3 <br />r <br />=I� <br />g � <br />4 <br />> I� <br />� <br />O <br />lr7 <br />T <br />_M <br />O <br />M <br />� <br />00 <br />U) i"n <br />O <br />r <br />Q <br />N <br />LO <br />Ic <br />-n CY) N <br />O <br />Q <br />LOA <br />Ito <br />00 In <br />o <br />E <br />z <br />E <br />c <br />a. <br />ov <br />v a M <br />JOB <br />NO : 22-05620-05615 <br />SCALE : AS NOTED <br />SHEET NO. <br />SN1 <br />PASCO COUNTY <br />