ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150At200A INDOOR <br />NEMA1 <br />150 AMP/ <br />200 AMP <br />I to lights & outlets <br />t to appliances and GFI <br />)to WH <br />to Range <br />150=2/O <br />200=4/0 in 2" Conduit <br />200 amp <br />150 amp <br />COMP. <br />WP <br />DISC. <br />14I �2'1 <br />I TR <br />h� <br />I � <br />UNDERGROUND connect � /J I I VV" v v <' I <br />SERVICE BY POWER CO. I 21j I 1 <br />4 Bare Cu Ground <br />__ OWNER'S OPT. CLG. FAN/ 3a R I <br />INTERSYSTEM � 11 <br />#4GROUNDING WIRE 1r�Irrn /, `\LIGHT PRE -WIRE I <br />TERMINATION PIER WITH CODE APPROVED SUITE G�I v v �n A �A%, <br />NEC 17.250.94 CLAMP PER 250.50 AND / / f'� G 3 3p N N <br />250.52 OF THE 2017 NEC. I �(� �At <br />GENERAL ELECTRICAL NOTES: <br />Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance With R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI LIL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the Installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped With a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would Include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />�...® <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />3 <br />THREE-WAY SWITCH <br />6. <br />iP4 <br />FOUR-WAY SWITCH <br />jR <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />;Ot <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />�P <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />©2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />JQ <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />(✓ J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />(i J <br />OPT. CEILING FAN <br />GD <br />(1) PHONE LINE, (1) DATA PORT <br />SMOKE DETECTORS <br />SMOKE DETECTORS SHALL BE IN ALL SLEEPING <br />AREAS, SHALL BE INTERCONNECTED, SHALL BE WITHIN <br />1' TO 3' OF PEAK, AND SHALL BE 3' FROM THE <br />SUPPLY OR AIR STREAM, AND EQUIPPED WITH <br />BATTERY BACK-UP. ALL SMOKE DETECTORS TO BE <br />ARC -FAULT PROTECTED. <br />FAIR HOUSING ACT REQUIREMENTS: <br />OPERABLE PARTS OF THE CONTROLS FOR LIGHT SWITCHES, ELECTRICAL <br />OUTLETS, THERMOSTATS AND OTHER ENVIROMENTAL CONTROLS MUST BE <br />LOCATED NO HIGHER THAN 48", AND NO LOWER THAN 15", ABOVE THE FLOOR. <br />IF THE REACH IS OVER AN OBSTRUCTION (FOR EXAMPLE, AN OVERHANGING <br />SHELF) BETWEEN 20 AND 25 INCHES IN DEPTH, THE MAXIMUM HEIGHT IS <br />REDUCED TO 44" FOR FORWARD APPROACH; OR 46" FOR SIDE APPROACH <br />PROVIDED THE OBSTRUCTION (FOR EAXMPLE, A KITCHEN BASE CABINET) IS <br />NOT MORE THAN 24 " IN DEPTH. OBSTRUCTIONS SHOULD NOT EXTEND MORE <br />THAN 25" FROM THE WALL BENEATH A CONTROL. <br />VERIFY P/ <br />LOCATOOP <br />BUILDER <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />UNIT 1500 - ELECTRICAL PLAN <br />SCALE: 1/4"=V-0" <br />N <br />q .S:: <br />o <br />(� 0 <br />C* <br />N <br />o <br />N <br />Ml X <br />CL <br />W <br />Q " <br />N <br />0 t) M <br />K <br />cn <br />0 <br />< <br />N y/ r: a) <br />•j ' ) W <br />;=0_0 <br />�_-L�c:: <br />!; O O <br />11 O W <br />N <br />O <br />N <br />rn <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code <br />Residential 7th Edition. Engineer's signature and seal <br />- <br />is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />N <br />L 0 <br />00 <br />0�M7� <br />a <br />LL <br />.J <br />� LLw <br />13 <br />��LL_ Lu <br />0 <br />W <br />, <br />1;--.g R <br />Z <br />LMZL IL <br />= <br />-H <br />04 <br />2 - d <br />N O U <br />W <br />0) <br />❑❑ <br />Ut N <br />Z <br />Z <br />Z � <br />a S <br />4-J <br />f0 <br />z) " <br />W <br />O <br />c <br />U <br />U <br />a 7 <br />N <br />o <br />w <br />J <br />"- <br />9 <br />aLL <br />� <br />�a <br />zu <br />Q <br />W v <br />� <br />-2 a_ <br />QQ E <br />! <br />a <br />g& <br />Zrn <br />J <br />pW <br />8U <br />W <br />Z <br />w� <br />_�'� <br />3 <br />121) (V <br />> Ln <br />Cn <br />_c <br />— <br />rn <br />is <br />O <br />O <br />M_ <br />T <br />MCo <br />L T <br />O <br />O <br />T <br />MQYi� <br />(may <br />°° <br />T <br />Cr <br />to m <br />a <br />0 <br />N <br />P r7 <br />c <br />.0 M <br />N <br />0 <br />Q r <br />0)to <br />CO <br />N <br />r- <br />O <br />E <br />Z <br />r <br />Z <br />a <br />Ev <br />U <br />¢ <br />c <br />°� <br />JOB <br />NO: 22-05620-05615 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />8 <br />