Laserfiche WebLink
*DIAGONAL SPACED <br />AT 15'-0" O.C. MAX <br />CONTINUOUS LATERAL <br />BRACING- NAIL OVER <br />X-BRACE AS SHOWN - <br />INSTALL BLKG. AT TRUSS <br />WEBS FOR NAILING <br />CROSS BRACING DETAIL (TYP.) <br />SCALE: 1/2" = V-0" <br />SEE ROOF <br />PLAN SHE <br />BLOCKING <br />2X4 BLOCKING <br />BETWEEN TRUSSES <br />SECT. A -A <br />X-BRACING - 2x4 SPF OR <br />SYP w/ 2-16d @ EACH TRUSS <br />WEB <br />G.T. <br />ADD 2X4 ALONGSIDE <br />TOP CHORD WHEN REQ'D <br />TO PREVENT PLYWOOD <br />SPAN FROM EXCEEDING <br />MAX 24" SPAN (EITHER <br />SIDE OR BOTH IF REQ'D) <br />PROVIDE 2X4 MIN. BLOCKING AT <br />Q OF HIP/RIDGE, TYP.BETWEEN <br />TRUSSES W/ (2) 12D NAILS EACH <br />END TO TRUSS TOP CHORD <br />TYP. <br />�A TRUSS <br />USSES <br />(2) 12D NAILS <br />AT 12" O.C. MAX <br />HIP/RIDGE BLOCKING DETAIL 2 <br />SCALE: 1/2"=1'-0" <br />TRUSS NOTES. <br />TYP. HAND FRAMING ABOVE TRUSS <br />FRAMED RIDGE 2X4 STUDS & PLATES AT 2.O. O.C. <br />CON1. <br />WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TP1-2002 <br />MAY B <br />MAYBE NAILED EACH DIRECTION TYP. U.N.O. <br />TRUSS PLATE INSTITUTE NOTE THAT THE COMBINED WIND AREA IS GREATER <br />( ) <br />w/ MIN. (4) 12d WHEN <br />BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE <br />IT LANDS NEXT TO <br />INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST <br />PRE-ENG. TRUSS 2x8 BLKING. NAILED @ EACH <br />COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES <br />SIDE w/ (3) 12d NAILS WHEN <br />OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD <br />REQUIRED w/ (2) USP HTW20 <br />SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & <br />SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION <br />W/ (14) - 10d X 1 1/2" EACH <br />OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED <br />ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER <br />A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. <br />�C <br />2. <br />ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS <br />LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTER ALL LATERAL BRACING <br />SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'-0" <br />'k <br />O.C. MAXIMUM. <br />3. <br />ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED W/ 2-16D <br />NAILS AT EACH TRUSS INTERSECTION. <br />CB <br />4. <br />ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS <br />DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT <br />TB <br />ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. <br />pg B <br />5. <br />PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS <br />DEPTH EXCEEDS STANDARD HEEL HEIGHT. SEE TYP. TRUSS BLOCKING DETAILS <br />PRE-ENG. TRUSS <br />2X4 DIAGONAL AT 8'-0" O.C. 2X4 BLOCKINGBETWEEN EA. TRUSS <br />CONT. ROOF SHEATHING AT TRUSS TOP <br />MAX & EACH END ALTERNATE A <br />DIRECTION TYP. ---\ A 41 <br />CHORD AT ALL HAND FRAMED AREAS TYP. <br />-----Z—WOOD TRUSS J <br />A <br />TYP. WOOD TRUSS BLOCKING DETAIL <br />SCALE: 1 /2"= V-0" <br />2 x P.T. BLOCKING <br />BY FRAMER FOR PROVIDE 25" LAP <br />PLYWOOD EDGE SPLICE @ F.C. REBAR <br />NAILING <br />PROVIDE (4) 10d <br />TOENAILS FROM TOP -CHORD BEARING <br />TRUSS TO LEDGER FLOOR TRUSSES @ <br />24" O.C. <br />4/ 2) 2x8 SYP #2 P.T. <br />LEDGER ATTACHED TO <br />MASONRY w/ (2) ROWS <br />1/2" SIMPSON TITEN HD, <br />MIN. 4" EMBEDMENT PER <br />54/D1 SPACING. <br />DOUBLE KNOCK -OUT <br />BLOCK w/ (1) #5 CONT. <br />IN EACH COURSE. <br />FLOOR CONNECTION @EXTERIOR WALL <br />SCALE: 3/4" = 1'-0" <br />VERTICAL SCAB <br />2 x 6 #2 SPF 48" O.C. <br />W/ (4) 10d TOP & <br />BOTTOM OR USP RT7 <br />OR HCLR/LL W/ 8 - 8d <br />IN PLACE OF (4) 10d <br />COLLAR TIE <br />EVERY 3rd <br />RAFTER <br />2x4 SPF 2 <br />(2) #7X 3-1/2" WOOD <br />SCREW EACH TRUSS <br />OR USP RT7 @ 48" O.C. <br />BEVEL CUTS <br />(OPTIONAL) <br />DIAGONAL 2x8 #2 SPF RIDGE BEAM <br />AT 8'-0" WOOD <br />MAX TRUSS 2x6 #2 SYP RAFTERS FOR SPANS 4FT <br />TO 8FT 2X4 RAFTERS FOR SPANS LESS <br />THAN 4FT @ 2'-0"O.C. MAX. w/ (3) 10d <br />COMMON TOENAILS TO RIDE BEAM <br />2X4 CONT. ATE CONC. MASONRY <br />T & B CHORD STEEL OR WOOD <br />BEARING SUPPORT <br />A -A ALTERNATE BLOCKING <br />DETAIL a@ INTERIOR BEARING 3 <br />SCALE: 1/2" = V-0" <br />PROVIDE BLOCKING AT ALL TRUSS BEARING <br />SUPPORT WHERE TRUSS DEPTH EXCEEDS <br />STANDARD HEEL HEIGHT <br />2'-0" MIN. <br />1'-0" 6" 6" V-0" 6" 6" 1'-0" <br />10 <br />TYP. TYP. <br />O O 1 O O O O- <br />I SPLICE <br />O I O O O <br />2'-0" SPLICE BEYOND 2'-0" <br />PART. ELEV. VIEW <br />DBL. KO. BLOCK <br />b- <br />n- <br />- - - <br />MIN.1 <br />MIN. <br />TYP. <br />24" MIN. <br />(2) 2x8 P.T. <br />ATTACHED <br />PROVIDE 30" LAP SPLICE <br />@ F.C. REBAR. <br />PROVIDE 8d NAILS <br />@4"O.C. <br />FLOOR TRUSSES <br />@ 24" O.C. <br />DOUBLE KNOCK -OUT <br />BLOCK W/ (1) #5 ALTERNATE: <br />CONT. IN EACH SINGLE 2x8 SYP #2 P.T. <br />HIP COURSE LEDGER ATTACHED TO MASONRY W/ <br />G.T (2)-1/2" DIA. TITEN HD MIN. 6" <br />EMBEDMENT PER 54/D1 SPACING <br />USP HGAM10 @ <br />4'-0"O.C.T&B <br />FLOOR ATTACHMENT 50 <br />SCALE: 3/4" = V-0" <br />(2) 2x8 SYP #2 P.T. CONT. <br />LEDGER w/ (2) ROWS OF 1/2" <br />TITEN HD STAGGERED @ 24" <br />O.C. w/ 4" EMBEDMENT & 6" <br />EACH SIDE OF SPLICE & <br />EACH END. <br />LEDGER <br />LAP SPLICE TOGETHER w/ <br />PART. PLAN VIEW (2) ROWS OF 10d @ 6" O.C. <br />LEDGER SPLICE DETAIL 54 <br />SCALE: 3/4" = V-0" <br />OPTIONAL 6" WIDE BOARD BATTEN <br />STRIPS TO ELIMINATE 3/4" AIR <br />SPACE. SEE MANUFACT. SPECS. <br />MASONRY <br />SEE PLAN <br />i')N_-I M TnC:nIAILS <br />2X6 P.T. CONT. <br />-EDGER T&B W/ (2) <br />1/4" X 3" TAPCONS @ <br />24" O.C. T&B <br />TRUSS <br />vvr vow vvr r v� r Iry X 1 i2" <br />NAILS TRUSS TO LEDGER <br />LEDGER DETAIL <br />SCALE: 3/4" = V-0" <br />MASONRY WALL <br />SEE FLOOR <br />PLAN FOR MORE <br />INFO. <br />STRUCTURAL SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />- VARIES W/ <br />ROOF SLOPE <br />MIN. 2x4 #2 SPF P.T. <br />CONT. W/ (2) 1/4 <br />/rTITENS SCREWS AT <br />16" O.C. <br />TRUSS OR <br />ROOF SYSTEM <br />SHEAR TRANSFER <br />EXTERIOR. WALL 52 <br />SCALE: 3/4" = V-0" <br />12 <br />SEE <br />ELEV. <br />v' 3/4" MIN. AIR SPACE <br />SEE ROOF PLAN <br />WOOD TRUSS <br />FOR STRAP INFO. <br />1" DENSGLASS ULTRA <br />TOP COURSE W/ <br />ATTIC DETAIL - ADJACENT TO TRUSSES SHAFT LINER <br />1 #5 CONT. <br />OPTIONAL 6" WIDE BOARD GA ASW 1002 SCALE: 3/4"=1'-0" <br />� <br />BATTEN STRIPS TO <br />SEE PLAN <br />ELIMINATE 3/4" AIR SPACE. 2x4 BLOCKING @ 48" O.C. MAX. W/ 5 LB FELT (SHINGLES) <br />TOP OF PLATE <br />SEE MANUFACT. SPECS. (2) 16d TOE NAILS @ EACH END & <br />FOR INSTALLATION. GLUED TO ROOF SHEATHING <br />IRE RESISTANT OSB 7/16" <br />2" CLG. RUNNER FIRE CAULK <br />SHEATHING 4' ON EA. SIDE <br />CEILING BOARD <br />PRE-ENGINEERED ROOF RUNNER TO SHEATHING <br />OF WALL NOT STAGGERED <br />TRUSSES AT 24" O.C. MAX ABOVE AT EACH SIDE <br />OVER PARTY WALL <br />LINTEL SEE <br />2x4 LEDGER @ 48" O.C. <br />MAX VERTICALLY NAILED <br />(2) LAYERS 1"x24" PROPRIETARY <br />y' <br />I TO TRUSS WEBS W/ (2) <br />° <br />TYPE "X" GYP. PANELS INSERTED <br />8d (TYP.) <br />SEE PLAN <br />E <br />BETWEEN 2" FLOOR & CLG. RUNNERS <br />BASE BOARD <br />T WIND W <br />W/ 2" STEEL H STUDS BETWEEN <br />°' <br />I <br />EXTEND BURN CLIPS AS PER <br />PER SPECS. <br />ADJACENT PAIRS OF GYP. PANELS. <br />° ° <br />2 x P.T. BLOCKING <br />FIRE WALL MFG. <br />BY FRAMER FOR <br />WINDOW PER PLAN <br />2" FLOOR RUNNER <br />° ° <br />° <br />R30 INSUL. MIN. <br />SPECIFICATIONS NAILED INTO <br />PLYWOOD EDGE <br />W/ 3/16" DIA. x 1 3/4" <br />TAPCONS AT 16" <br />" <br />2x4 LEDGER ONLY AT EACH <br />SIDE OF STEEL H STUD. <br />NAILING <br />O.C. FIRE CAULK <br />PROVIDE (4)-10d <br />RUNNER TO BLOCK <br />TOENAILS FROM <br />8" C.M.U. WALL <br />WALL EACH SIDE <br />TRUSS TO LEDGER <br />(1) LAYER 1/2" HIGH STRENGTH <br />EACH SIDE <br />STD 909 HOOK <br />OR 5/8" GYP. WB. W/ 1 3/8" <br />NOTES: <br />DRYWALL NAILS OR DRYWALL <br />3/4" FLOOR <br />1. SEPARATION WALL IN THE <br />SCREWS 7" O.C. EDGES. <br />SHEATHING <br />ROOF SYSTEM PROVIDES <br />2-HRS. PROTECTION PER <br />GP WHI 945-0743. <br />2. MASONRY WALL PROVIDES <br />(1) #5 VERT. IN FILL CELLS <br />s ` <br />1x P.T. NAILER INSTALLED <br />10'-8" <br />2-HRS PROTECTION PER <br />(SEE FILL CELL PLAN FOR <br />LOCATIONS) <br />1 <br />AFTER INSTALLING RBC'S <br />^ <br />UL-U905 <br />8"x8"x16" CONC. KNOCKOUT <br />2 x P.T. BLOCKING BY FRAMER FOR <br />BLK. W/ 1 #5 ROD CONT. <br />PLYWOOD EDGE NAILING <br />FILLED W/ GROUT <br />\� ; %� <br />� <br />DOUBLE KNOCK -OUT <br />(2) 2x8 SYP #2 P.T. CONT. LEDGER w/ (2) <br />4"1 INSPECTION PORT AT <br />W/ (1) #5 CONT. IN. <br />ROWS OF 1/2" TITEN HD STAGGERED @ <br />EACH FILLED CELL (TYP.) <br />EACH COURSE <br />24" O.C. w/ 4" EMBEDMENT & 6" EACH <br />SIDE OF SPLICE & EACH END, SEE 5401. Z <br />w <br />U <br />1x P.T. BASE NAILER <br />PRE-ENGINEERE <br />7 <br />3/4" PLYWOOD DECKING GLUED AND <br />STD. 909 HOOK <br />FLOOR TRUSS' AT <br />O.C. 24" O.C. <br />NAILED W/ 8d COMMON AT 6" O.C. N <br />� <br />� <br />(SEE DETAIL) <br />j - <br />q <br />gI <br />NAIL FLOOR TRUSS TO LEDGER <br />—W/ <br />EDGES AND 12" O.C. FIELD <br />e <br />/ <br />f (4) 10d TOENAILS (TYP.) <br />GYP. BOARD CLG. <br />1/2" GYP. WB. OR 3/8" PLYWOOD/TYP 2-M-W / <br />OSB (DRAFTSTOPPING) TO BE NAILED W/ 8d <br />COMMEN AT 6" O.C. TO ONE SIDE OF FLOOR TOP CHOft tRI <br />TRUSS FOR AN AREA < 1000 S.F. AND SEALED \ FLOOR'SYSTEM <br />PENATRATION AREAS W/ FOAM. DRAFTSTOPPI^ 6 '� <br />SHALL DIVIDE THE CONCEALED SPACE INTO <br />APPROX. EQUAL AREAS <br />(1) LAYER 1/2 HIGH STRENGTH OR 5/8 GYP. <br />WB. (OR 5/8" GYP. TYPE "X" @ GARAGE W/ <br />A HABITABLE ROOM ABOVE) W/ 1 3/8" <br />DRYWALL NAILS OR DRYWALL SCREWS <br />7" O.C. CEILING, 8" O.C. WALLS & 4" O.C. EDGES <br />(1) #5 VERT. IN FILL CELLS <br />(SEE FOUNDATION PLAN FOR LOCA <br />8" CONC. BLOCK (TYP.) <br />1x P.T. BASE NAILER <br />6x6 W1.4xW1.4 WWF. —� <br />M <br />=_ <br />\_8"x8"x16" CONC. KNOCKOUT <br />BLOCK W/ (1) #5 ROD CONT. <br />'. <br />FILLED W/ GROUT <br />' <br />1" P.T. NAILER <br />R-3 MIN. INSUL. PER. FBC. <br />1/2" GYP. WB. <br />TYP. "S" MORTAR (TYP.) <br />U <br />z <br />W <br />' <br />N <br />N <br />4"x4" INSPECTION PORT. <br />ji. <br />AT EACH FILLED CELL (TYP.) <br />_9 <br />T <br />(4) #5 CONT. STD. 902 HOOK <br />ON 3" CHAIR 8" 2'-0" 8" (SEE DETAIL) <br />2-STORY PARTY WALL SECTION PWO <br />SCALE: 3/4"=V-0" <br />SEE 53/D1 FOR <br />LEDGER CONNECTIONS <br />1/2" GYP. BD. —� <br />(2)-1 X 4 P.T o ^ <br />NAILER <br />BASE BOAT <br />PER SPEC: <br />CONC. S1 <br />SEE FOUND <br />6 MIL VISQUI <br />TREATED; <br />REINFORCING W/ MATCHING <br />#5 DOWELS IN SOLID <br />GROUTED CELL W/ MIN. 25" <br />LAP SPLICE MIN. <br />8" C.M.U. WALL <br />JP OF SLAB <br />bo <br />N <br />v- <br />3 #5 CONT. 20" <br />TYP. 2 STORY WALL SECTION <br />SCALE: 3/4" = V-0" <br />0'-0" <br />F.F. <br />VARIES WITH <br />SITE GRADES <br />SEE PLAN <br />181 <br />c^4 <br />N <br />wy <br />i <br />j W <br />CDYo <br />C2- r o <br />G A m � <br />�L.�a <br />u, cc o <br />✓� O cp c7 <br />4 <br />d 6) <br />io �� c) <br />v � <br />L' <br />G <br />7A& <br />o <br />. <br />L Q!�` <br />2 <br />,✓'�,oOFCSSiMONP <br />�� <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />N <br />W <br />ag,s <br />v E <br />0 <br />0 <br />o <br />N <br />>�a0 rn <br />v�-'Z— 2 <br />M <br />Q <br />M CD <br />V # LL <br />N 25Z J <br />a LL U_ 5 LL (1 <br />Z <br />_ w <br />rn o 5 <br />LU <br />N c_p O <br />r- o <br />W <br />LL <br />-U p 0 coJ <br />M G <br />(9Z <br />N OU o <br />Z <br />W <br />❑El <br />Z N Ih <br />og <br />�g <br />r <br />M <br />z <br />Cz <br />0-1 <br />a <br />LL <br />4-1 <br />(6 <br />w � <br />'° <br />U <br />O <br />N <br />�N <br />S <br />C N <br />W <br />w <br />J <br />U o <br />c U) 0 <br />Q O] 0 <br />m <br />®0 <br />N <br />CD <br />w <br />co <br />o <br />a <br />� <br />� <br />>� <br /><o <br />41 <br />C 0 <br />20 <br />oa <br />UO <br />CDp <br />CV <br />_ U <br />a <br />w Z. <br />U <br />Oa <br />a Z <br />a � <br />r. <br />a <br />O <br />0 <br />Z�c <br />�z <br />� J <br /><tl <br />zo <br />U <br />hw <br />J W <br />S <br />IIIII� <br />co <br />c0 <br />a = <br />0 <br />� <br />iIa <br />� <br />.y0 C <br />V <br />> LO <br />co <br />O <br />O <br />\ <br />� <br />T <br />Al <br />M <br />CU TCD <br />Q <br />r <br />OO <br />/ A o <br />V/ m <br />00 <br />oQ <br />T <br />0 <br />N <br />�= <br />N <br />CD <br />Q <br />N <br />N <br />C) <br />to <br />E <br />E <br />z <br />c v00 <br />7 V <br />N <br />z <br />E <br />E <br />w <br />m <br />c <br />0 <br />U J <br />t7 <br />Q 0 <br />c <br />J <br />JOB <br />NO: 22-06575-06570 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />D 1 <br />