Laserfiche WebLink
a ­.w..: .-,:. n,,-.,_,. -..•,. .,. „ - --- 1 n - - -- - ---- - - -- - - I -. " II1'I�II <br />LEGEND <br />— — <br />COLD WATER PIPE <br />— — — — — — <br />HOT WATER PIPE <br />S <br />SANITARY PIPE <br />— — — — — — — — <br />VENT PIPE <br />O— c <br />PIPE UP / PIPE DOWN <br />T <br />PIPE TEE FROM TOP / TEE FROM BOTTOM <br />E 4— <br />PIPE CAP/ PIPE CONTINUATION <br />—•—� <br />BALL VALVE / CHECK VALVE <br />FLOOR DRAIN / FLOOR SINK <br />oc <br />P-TRAP <br />VENT THROUGH ROOF <br />'a <br />CONNECTION TO EXISTING <br />ABBREVIATION5 <br />A/C <br />ABOVE CEILING <br />FFE <br />FINISHED FLOOR ELEVATION <br />A/F <br />ABOVE FLOOR <br />HW <br />HOT WATER <br />B/F <br />BELOW FLOOR <br />IMB <br />ICE MACHINE BOX <br />BFP <br />BACKFLOW PREVENTEK <br />L / LAV <br />LAVATORY <br />CD <br />CONDENSATE DRAIN <br />MS <br />MOP SINK <br />CONT <br />CONTINUATION <br />MV <br />MIXING VALVE <br />CW <br />COLD WATER <br />S / SAN <br />SANITARY <br />DN <br />DOWN <br />SK <br />SINK <br />ET <br />EXPANSION TANK <br />TYP <br />TYPICAL <br />EWC <br />ELECTRIC WATER COOLER <br />V <br />VENT <br />FCO <br />FLOOR CLEANOUT <br />WC <br />WATER CLOSET <br />FD <br />FLOOR DRAIN <br />WMB <br />WASHING MACHINE BOX <br />ELECTRIC WATER HEATER 5CH EDU LE <br />TANK <br />TAG <br />RECOVERY <br />5ETPOINT <br />ELECTRICAL <br />BA515 <br />CAPACITY <br />WH- 1 <br />30 GAL <br />8 GPH @ 80- RISE <br />1 20' <br />1 .5 KW <br />RHEEM EG5P30 <br />P ELECTRICAL PRIOR TO SUBMITTAL OR PURCHASE-THEPLUMBING CONTRACTOR SHALL VERIFY THE APPROPRIATE E ELEC R CHARACTERISTICS OF THE <br />SELECTED WATER HEATER. COORDINATE DIRECTLY WITH THE ELECTRICAL CONTKACTOK AND THE POWER PANEL SCHEDULES ON THE ELECTRICAL <br />DRAWINGS. <br />PLUMBING FIXTURE SCHEDULE <br />WATER RUNOUT <br />WATER CONN. <br />MARK <br />DESCRIPTION <br />WASTE <br />WASTE <br />VENT <br />5PECIFICATION <br />RUNOUT <br />CONN. <br />CW <br />HW <br />CW <br />HW <br />WALL HUNG LAVATORY (AMERICAN STANDARD "LUCERNE," 0355.0 12) WITH CONCEALED <br />ARM CARRIER MOUNTING (ZURN Z 123 1). PROVIDE 0.5GPM SINGLE HANDLE FAUCET WITH <br />POLISHED CHROME FINISH (DELTA 50 1 LF-HGMHDF). HANDICAP DRAIN OFFSET W/GRID <br />L- I <br />LAVATORY (ADA) - WALL HUNG <br />2" <br />1 1/2" <br />2" <br />112" <br />1/2" <br />3/8" <br />3/8" <br />DRAIN (Z_URN Z874G-PC) AND CHROME PLATED P-TRAP (ZURN Z5701 -PC). CHROME PLATED <br />BiRA55 ANGLE SUPPLY STOPS WITH FLEX SUPPLIES (MCGU(RE H I G5). INSULATE OFFSET, <br />TRAP AND SUPPLY LINES (TRUEBRO "LAVGUARD.." # 103 E-Z). PROVIDE MIXING VALVE TO <br />TEMPER HOT WATER TO I 10 DEGREES (LAWLER 7MM', ASSE 1070, LEAD FREE). <br />WALL HUNG LAVATORY (WHITEHAUS WH- 103K-W). PROVIDE 0.5GPM SIIIGLE HOLE, SINGLE <br />HANDLE FAUCET WITH POLISHED CHROME FINISH (KOHLER K-97282-4). PROVIDE GRID <br />L-2 <br />LAVATORY - WALL HUNG <br />2" <br />1 1 /2 <br />211 <br />11211 <br />1 /2 <br />3/8 <br />3/8 <br />DRAIN AND CHROME PLATED P-TRAP. PROVIDE MIXING VALVE TO TEMPER NOT WATER TO <br />I 10 DEGREES (LAWLER'TMM', ASSE 1070, LEAD FREE). <br />FLOOR MOUNTED, ELONGATED ADA TANK TYPE WATER CLOSET (AMERICAN STANDARD <br />"CADET PRO RIGHT HEIGHT," 21 5AA. 104), 1.25 GPF, WHITE VITREOUS CHINA, GRAVITY FED <br />FLUSH ACTION, TOP OF RIM AT 1 G.S" AFF. HIGH EPFICIENCY'WATFRSENSF' LISTED. <br />PROVIDE ALTERNATE TANK CONFIGURATION (2 1 5AA. 1 05) WITH TRIP LEVER ON RIGHT HAND <br />WC- <br />WATER CLOSET (ADA) - TANK TYPE <br />4" <br />3" <br />2" <br />I/2" <br />/2° <br />SIDE IF NECESSARY TO HAVE LEVER ON MOST ACCESSIBLE SIDE OF WATER CLOSET. HEAVY <br />DUTY OPEN FRONT SEAT. LESS COVER, WITH 5ELF-5U5TAIN[NG CHECK HINGE (BEMIS <br />105555C). CHROME PLATED BRASS ANGLE SUPPLY STOP WITH 1 2" LONG X 3/5" FLEX <br />SUPPLY (MCGUIRE M I GG). <br />BI-LEVEL WATER COOLER (ELKAY EZSTLBLFC) WITH GLASS FILLER ACCESSORY (ELKAY <br />WATER COOLER (ADA) - BI-LEVEL, <br />LK I I 10). ORIFICES AT 38 3/8" AND 327/8" AFF. 8 GPH OF 50DEG WATER @ BODEG <br />EWC- I <br />2" <br />112" <br />2" <br />112 <br />_-- <br />112" <br />--- <br />WITH GLASS FILLER <br />ROOM TEMPERATURE. PROVIDE ACCESSORY APRON (LKAPREZL) IF INSTALLED ON AN <br />5PECIFICA F ION5 <br />ALL WORK SHALL COMPLY WITH ALL STATE, CITY AND LOCAL CODES, RULES AND REGULATIONS. <br />CONTRACTOR SHALL SECURE ALL REQUIRED PERMITS AND INSPECTIONS ASSOCIATED WITH THIS WORK, <br />AND SHALL PAY ALL COSTS AND FEES INVOLVED. <br />THESE DRAWINGS ARE DIAGRAMMATIC AND DO NOT REFLECT ALL POSSIBLE PHYSICAL CONDITIONS. <br />REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS AND EXACT LOCATIONS OF EQUIPMENT <br />AND FIXTURES. <br />THE CONTRACTOR IS RESPONSIBLE FOR REVIEWING THE ARCHITECTURAL, STRUCTURAL, CIVIL, <br />MECHANICAL 4� ELECTRICAL DRAWINGS (AS APPLICABLE) TO ENSURE ALL PLUMBING WORK IS IS <br />COORDINATED WITH PHYSICAL CONDITIONS. PROVIDE NECESSARY OFFSETS, RISES, AND PIPING TO <br />COORDINATE WITH THE BUILDING STRUCTURE, WORK OF OTHER TRADES, AND CONNECT POINTS TO <br />SITE UTILITIES (AS APPLICABLE). <br />CONTRACTOR SHALL REVIEW ALL CONTRACT DOCUMENTS AND SHALL BE FAMILIAR WITH THE SCOPE <br />AND REQUIREMENTS OF THIS PROJECT. ANY DISCREPANCIES OR LACK OF CLARITY IN THE DOCUMENTS <br />SHALL BE IDENTIFIED TO THE AIE PRIOR TO THE SUBMISSION OF PRICING BIDS. WITH A SUBMITTED <br />BID, CONTRACTOR IS ACCEPTING THESE DOCUMENTS AS SUFFICIENT DEFINITION OF THE SCOPE OF <br />WORK, AND ANY ADDITIONAL COSTS BASED ON UNCLARITY OF CONTRACT DOCUMENTS WILL NOT BE <br />CONSIDERED, <br />CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND LOCATIONS FOR EQUIPMENT INSTALLATION PRIOR <br />TO THE SUBMITTAL OF SHOP DRAWINGS. ALL EQUIPMENT AND DEVICES SHALL BE INSTALLED SUCH <br />THAT THEY ARE EASILY ACCESSIBLE AND SERVICABLE. THIS EQUIPMENT INCLUDES, BUT IS NOT LIMITED <br />TO: PLUMBING FIXTURES, WATER HEATERS, VALVES, CLEANOUTS, THERMOMETERS, GAUGES, <br />STRAINERS AND TRAP PRIMERS. <br />COORDINATE THE ELECTRICAL REQUIREMENTS AND CHARACTERISTICS OF ALL PLUMBING EQUIPMENT <br />WITH THE ELECTRICAL CONTRACTOR PRIOR TO PURCHASING EQUIPMENT. <br />ALL WO SHALL BE INSTALLED IN ACCORDANCE WITH THE BEST RECOGNIZED PRACTICE! IN THE FIELD <br />WORK R R RA <br />CONCERNED. MANUFACTURED ITEMS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE <br />MANUFACTURER'S PRINTED DIRECTIONS, SPECIFICATIONS AND RECOMMENDATIONS. <br />THE CONTRACTOR 15 RESPONSIBLE FOR REVIEWING THE ARCHITECTURAL DRAWINGS TO ENSURE THERE <br />IS ADEQUATE WALL THICKNESS SUCH THAT ALL WATER PIPING, SANITARY PIPING, VENT PIPING, WALL <br />CLEANOUTS, HOSE BIBBS, NON FREEZE WALL HYDRANTS, AND RECESSED ACCESS PANELS WILL FIT IN <br />WALL SPACE. CONTRACTOR SHALL NOTIFY THE ARCHITECT IF WALL SPACE IS INADEQUATE PRIOR TO <br />COMMENCING WORK. <br />UNLESS NOTED OTHERWISE, ALL DRAINAGE PIPING SHALL BE SLOPED AT A MINIMUM Of/5" PER FOOT <br />2" SANITARY PIPING AND ALL GREASE WASTE PIPING SHALL BE SLOPED ATY4 PER FOOT. <br />DOMESTIC WATER PIPING SHALL BE PURGED OF DELETERIOUS MATTER AND DISINFECTED PRIOR TO <br />UTILIZATION. PIPING TO BE FLUSHED AND STERILIZED IN ACCORDANCE WITH IPC G 10, 1 AND ALL <br />APPLICABLE LOCAL AND STATE HEALTH DEPARTMENT STANDARDS. <br />PIPE PENETRATIONS THROUGH FIRE RATED WALLS OR FLOORS SHALL HAVE EQUIVALENTLY RATED <br />SLEEVES AND SHALL BE SEALED AND FIRE CAULKED WITH A U.L. LISTED FIRE STOPPING SYSTEM <br />INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S LISTED DETAILS AND SPECIFICATIONS. <br />THE CONTRACTOR SHALL OBTAIN EXACT WALL, FIXTURE, AND LAYOUT DIMENSIONS FROM THE <br />ARCHITECTURAL DRAWINGS. THE CONTRACTOR 15 RESPONSIBLE FOR OBTAINING ROUGH -IN AND <br />INSTALLATION DRAWINGS FOR ALL PLUMBING FIXTURES, KITCHEN EQUIPMENT AND OWNER FURNISHED <br />EQUIPMENT (AS APPLICABLE), AND SHALL COORDINATE THE PLUMBING INSTALLATION PRIOR TO <br />COMMENCING THE WORK, THE CONTRACTOR IS PESPONSLBLE FOR PROVIDING AND INSTALLING ALL <br />NECESSARY VALVES, CONNECTIONS, TRAPS, ACCESS PANELS, UNIONS, ESCUTCHEONS, WATER <br />HAMMER ARRESTORS, VACUUM BREAKERS, RELIEF VALVES, PIPE INSULATION, AND EQUIPMENT <br />SPECIALTY DEVICES AS REQUIRED TO FACILITATE COMPLETE AND OPERATIONAL CONDITIONS WHICH <br />ARE IN STRICT COMPLIANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. <br />THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING WITH THE REQUIREMENTS OF THE COUNTY <br />HEALTH DEPARTMENT AND OTHER LOCAL AUTHORITIES HAVING JURISDICTION REGARDING CROSS <br />CONNECTION CONTROL OR OBTAINING A FOOD SERVICE PERMIT (AS APPLICABLE). REPORT ANY <br />OBSERVED DISCREPANCIES TO THE AIE PRIOR TO COMMENCING WITH THE WORK. <br />PLATFORM MOUNTED ELECTRIC WATER HEATER <br />NO SCALE <br />VACUUM RELIEF VALVE <br />(WATTS LFN3G-M I OR <br />EQUAL) <br />THERMOMETER <br />DIELECTRIC UNION <br />(TYP) <br />ENGINEERED <br />SUSPENDED WATER <br />HEATER PLATFORM <br />SYSTEM BY'HOLDRITE,' <br />INCLUDING GALVANIZED <br />HOT WATER <br />5PEC1 FICATION5 <br />WASTE AND VENT PIPING SYSTEMS AND ACCESSORIES <br />SANITARY PIPING BELOW GROUND SHALL BE PVC SCHEDULE 40 TYPE DWV WITH SOLVENT WELD JOINTS. SOLVENT <br />WELD JOINTS SHALL MEET ASTM T-702.3 AND ASTM D-2GG5. <br />SANITARY PIPING AND VENT PIPING ABOVE GROUND SHALL BE PVC SCHEDULE 40 TYPE DWV WITH SOLVENT WELD <br />JOINTS. SOLVENT WELD JOINTS SHALL MEET ASTM D-2GG5. <br />WASTE AND VENT PIPING SHALL BE TESTED IN ACCORDANCE WITH THE GOVERNING CODES. AT A MINIMUM, WASTE <br />PIPING SHALL BE TESTED WITH AT LEAST 10 FOOT OF WATER HEAD PRESSURE APPLIED. TESTING WITH AIR IS NOT <br />ALLOWED. <br />ALL VENTS THROUGH ROOF SHALL BE LOCATED AT LEAST 1 0'-0" AWAY FROM ANY AIR INTAKE, EVAPORATIVE <br />COOLER, OR ANY OTHER DEVICE THAT WOULD DRAW AIR FROM THE VENT. FLASH AROUND ALL PIPES PENETRATING <br />THROUGH ROOF WITH STANDARD MANUFACTURED FLA5HINGS. FLASHING SHALL BE SHEEI METAL WITH RUBBER <br />GASKETS AND SHALL EXTEND INTO ROOFING AND UP PIPE DISTANCES IN ACCORDANCE WITH THE LOCAL CODE. <br />DOMESTIC WATER SYSTEMS AND ACCESSORIES <br />WATER PIPING ABOVE FLOOR: HOT AND COLD WATER PIPING ABOVE GROUND SHALL BE CPVC (CHLORINATED <br />POLYVINYL CHLORIDE) SCHEDULE 40 WITH SOLVENT WELD JOINTS WHEN APPROVED BY THE AUTHORITY HAVING <br />JURISDICTION. PIPING SHALL MEET ASTM D 2848 AND SHALL BE CERTIFIED BYTHE NSF INTERNATIONAL FOR USE <br />WITH POTABLE WATER SYSTEMS. SOLVENT CEMENTS FOR CPVC PLASTIC PIPING SHALL MEET ASTM 1`437, ASTM <br />P438 AND ASTM 1`439. <br />ALL DOMESTIC HOT WATER PIPING SHALL HAVE A MINIMUM PRESSURE RATING OF I OOPSI AT 1 80°F <br />DOMESTIC WATER PIPING SHALL BE TESTED IN ACCORDANCE WITH ALL GOVERNING CODES. PIPING SHALL BE <br />PURGED OF DELETERIOUS MATTER AND DISINFECTED PRIORTO UTILIZATION. PIPING TO BE FLUSHED AND <br />STERILIZED IN ACCORDANCE WITH IPC G I O. I AND ALL APPLICABLE LOCAL AND STATE HEALTH DEPARTMENT <br />STANDARDS. <br />BALL VALVES SHALL BE TWO-PIECE BRONZE BODY, LARGE PORT WITH SOLID, SMOOTH BORE CHROME PLATED <br />BRASS BALL. SEATS SHALL BE REINFORCED TFE WITH TEFLON PACKING RING AND THREADED ADJUSTABLE PACKING <br />NUT. PROVIDE STEM EXTENSION AS NEEDED TO PROVIDE HANDLE ON OUTSIDE OF PIPE INSULATION. VALVES <br />SHALL BE APOLLO 70 OR EQUAL. <br />3ACKFLOW PREVENTERS SHALL BE INSTALLED IN ACCESSIBLE LOCATIONS FOR EASE OF TESTING AND SERVICING. <br />FOR BACKPLOW PREVENTERS WITH VENT CONNECTIONS, ROUTE VENT LINE TO NEAREST DRAIN AND DISCHARGE <br />WITH AIR GAP. BACKFLOW PREVENTERS SHALL BE TESTED IN ACCORDANCE WITH IPC 312. 10.2. CONTRACTOR <br />SHALL PROVIDE CERTIFICATIONS THAT STATE DEVICES HAVE BEEN TESTED AND APPROVED. <br />INSULATION <br />INSULATE ALL DOMESTIC HOT WATER PIPING REGARDLESS OF MATERIAL. WHERE RECIRCULATED HOT WATER IS <br />SHOWN, INSULATE ALL HOT WATER AND RECIRCULATION PIPING WITH 1 " THICK INSULATION PER CHAPTER 5 OF IECC. <br />FOR NON -RECIRCULATED HOT WATER SYSTEMS, INSULATION THICKNESS SHALL BE AS FOLLOWS: PIPE UP TO 1": y" <br />THICK INSULATION. PIPE 14" TO 2": 1 " THICK INSULATION <br />FOR CPVC COLD WATER PIPING, INSULATE ALL HORIZONTAL PIPING 11" AND OVER LOCATED ABOVE CEILING. THE <br />INSULATION SHALL BE 1 " THICK. <br />FOR COPPER COLD WATER PIPING, INSULATE ALL HORIZONTAL PIPING LOCATED ABOVE CEILING AND ALL VERTICAL <br />PIPING LOCATED IN AN EXTERIOR WALL. <br />PIPE UP TO 1 ":y" THICK. PIPING ly" AND OVER: 1 11 THICK INSULATION <br />INSULATION SHALL HAVE A K-FACTOR (AVERAGE THERMAL CONDUCTIVITY) NOT TO EXCEED 0.27 BTU-IN/(HXSQFTX°F). <br />TANK TYPE WATER HEATERS <br />WATER HEATERS SHALL BE U_L. LISTED AND SHALL MEET OR EXCEED THE STANDBY LOSS REQUIREMENTS OF U.S. <br />DEFT. OF ENERGY AND CURRENT EDITION OF ASHRAEIIESNA 90. I <br />WATER HEATERS SHALL HAVE 1 50PSI WORKING PRESSURE AND BE EQUIPPED WITH EXTRUDED HIGH DENSITY ANODE <br />ROD AND HIGH TEMPERATURE CUTOFF SWITCH. WATER HEATERS SHALL BE THERMOSTATICALLY CONTROLLED AND <br />SET TO 120' UNLESS OTHERWISE NOTED. WATER HEATERS SHALL BE INSTALLED ON SUSPENDED PLATFORM, STEEL <br />STAND OR CONCRETE PAD, AS INDICATED ON DRAWINGS. <br />WATER HEATERS SHALL HAVE A MINIMUM 3 YEAR LIMITED WARRANTY <br />WATER HEATERS SHALL BE INSTALLED LEVEL AND PLUMB, FIELD COORDINATE EXACT WATER HEATER LOCATION. <br />MAINTAIN MANUFACTURERS RECOMMENDED CLEARANCES, AND INSTALL SUCH THAT CONTROLS AND DEVICES ARE <br />ACCESSIBLE FOR SERVICING. <br />INSTALL SHUTOFF VALVES IN COLD WATER INLET AND HOT WATER OUTLET, INSTALL THERMOMETER ON HOT WATER <br />OUTLET. WATER HEATER SHALL HAVE ASME RATED COMBINATION TEMPERATURE AND PRESSURE RELIEF VALVE IN <br />TOP PORTION OF TANK (FACTORY OR FIELD INSTALLED). PIPE RELIEF VALVE OUTLET TO FLOOR DRAIN, MOP SINK,. <br />INDIRECT WASTE RECEPTOR ORTO EXTERIOR. MAINTAIN CONTINUOUS DOWNWARD PITCH TOWARD DISCHARGE <br />LOCATION AND PROVIDE AIR GAP AT DISCHARGE LOCATION. WHERE WATER HEATER DRAIN PAN IS INDICATED ON <br />PLANS, ROUTE DRAIN TO SAME LOCATION AS RELIEF VALVE AND DISCHARGE WITH AIR GAP. <br />COLD WATER <br />BALL VALVE (TYP) <br />CHECK VALVE <br />THERMAL EXPANSION <br />TANK (SEE PLMB <br />FIXTURE SCHEDULE) <br />IF NOT FACTORY PROVIDED, <br />INSTALL ASME RATED TAP <br />RELIEF VALVE (WATTS 40XL <br />SERIES OR EQUAL) <br />HARDWARE PROVIDI <br />WITH KIT. REFER TC <br />MANUFACTURER'S <br />INSTALLATION <br />INSTRUCTIONS FOR <br />SPECIFIC DETAILS C <br />ATTACHING BRACEE <br />TO MASONRY WALL <br />FRAMED WALL, ETC. <br />TWO DIAGONAL <br />BRACES ACROSS TOP <br />OF WATER HEATER <br />FIELD COORDINATE <br />STRUCTURE ABOVI <br />RIGIDLY SUPPORT I <br />FOUR THREADED R <br />CONTRACTOR SHA <br />PROVIDE/2" THREA <br />CONNECT TO EACI- <br />FOUR CORNER BR/ <br />DRAIN PAN WITH <br />FACTORY PROVIDE <br />PVC DRAIN CONNE <br />(TYPICAL BOTH DEI <br />OPTION 'A'- SUPPORT FROM WALL <br />OPTION 'B' - SUPPORT FROM STRUCTURE ABOVE <br />PROFICIENT <br />E N G I N E E R I N G <br />6991 Peachtree Industrial Blvd Building 700 <br />Peachtree Cornets, Georgia 30092 <br />404.330.9798 <br />PROJECT # 118166 <br />H > <br />w Z�Zo <br />H 000N <br />2 2 <br />� pro <br />Q azow <br />F- r- <br />�Rm� <br />Vr zOO <br />zom= <br />F <br />2 '.1.V ' <br />oO. <br />Zn0=, <br />w �Qa3V <br />p <br />w w�>� <br />=zoz0 <br />C7 �azao <br />0 <br />`��y�aaurr,►,rp <br />i * : No. 70199 <br />IOR10p •. � ,,. <br />��. <br />G <br />N <br />E <br />H <br />U <br />W <br />H <br />U <br />N <br />o2 <br />MO <br />�Q U <br />V <br />Z <br />z(D <br />�LLLLN <br />QLL <br />w <br />LO <br />LJJ = Il- <br />00 <br />Z `./ <br />Q Z <br />a(D <br />U10� <br />w <br />w LL <br />= <br />U) <br />LO <br />PT SOVL41TtONIS: <br />Z <br />O0 LO <br />_ UQM <br />LL. w <br />� o � LL <br />JJow <br />^ J m J <br />(`,r) 2 J 2 <br />Cn <br />M <br />-17 <br />a o rl <br />NI�� N <br />04-09-2018 <br />