DRYER EXHAUST DETAIL <br />NO SCALE <br />PROVIDE FIRESTOPPING AT <br />PENETRATION OF RATED <br />ASSEMBLIES <br />PROVIDE (2) 1 8x 10 <br />MAKEUP AIR GRILLES <br />EQUAL TO TITUS 350ZFL <br />DOOR <br />NOTE: <br />EXTEND DRYER VENT TO <br />U.L. LISTED CAP WITH <br />BACKDRAFT DAMPER. <br />4" Q DRYER VENT <br />IN WALL DOWN TO <br />DRYER WALL BOX. <br />DRYER WALL BOX <br />FLEXIBLE CONNECTOR <br />31-01, <br />(0-0" FOR STACKED) <br />I . EXHAUST DUCT VENT PIPE FOR CLOTHES DRYERS <br />SHALL BE SHEET METAL, MINIMUM 2G GAUGE, AND <br />HAVE A SMOOTH INTERIOR FINISH AND SHALL BE <br />MINIMUM OF 4"0. THE ENTIRE EXHAUST SYSTEM <br />SHALL BE SUPPORTED AND SECURED IN PLACE WITH <br />NO PENETRATIONS OF THE DUCTWORK. THE MALE END <br />OF THE DUCT AT OVERLAPPED DUCT JOINTS SHALL <br />EXTEND IN THE DIRECTION OF AIRFLOW. <br />2. DRYER EXHAUST DUCT SHALL TERMINATE IN WALL AT A <br />DRYER WALL BOX. THE BOX SHALL HAVE A <br />CONNECTION IN THE VERTICAL POSITION FOR FLEXIBLE <br />CONNECTOR TO DRYER COLLAR. <br />3. CLEAN -OUT OF THE DRYER VENT EXHAUST SYSTEM <br />CAN BE ACCOMPLISHED BY REMOVING THE FLEXIBLE <br />CONNECTOR AND REMOVING ANY EXCESS DRYER LINT. <br />4. THE ENTIRE DRYER EXHAUST VENT SYSTEM SHALL BE <br />IN ACCORDANCE WITH THE LATEST LOCAL <br />MECHANICAL CODES AND AMENDMENTS. <br />5. IF LAUNDRY CLOSET DOOR IS LOUVERED, MAKEUP AIR <br />GRILLES MAY BE OMITTED. <br />DRYER VENT WALL BOX DETAIL <br />NO SCALE <br />DRYER VENT <br />DRYERBOX N <br />425 OR EQL <br />BASEBOARD <br />,RYER <br />JST DUCT <br />)TES; <br />I NSTALL DRYER VENT BOX <br />PER MANUFACTURER'S <br />RECOMMENDATIONS. <br />DRYER BOX 15 RATED TO BE <br />INSTALLED IN A I -HOUR <br />WALL WHEN INSTALLED IN <br />ACCORDANCE WITH U.L. <br />SYSTEM NO. W-L-71 29. <br />DIFFUSER TAKE -OFF DETAIL <br />NO SCALE <br />ROUND SHEET <br />METAL DUCT <br />DIAMETER AS <br />INDICATEDON <br />PLANS. <br />TRUNK DUCT <br />NOTE: <br />SPIN -IN FITTING <br />WITH SCOOP <br />DAMPER HERE FOR <br />ACCESSIBLE CEILINGS <br />CONNECT FLEX DUCT ENDS TO <br />SHEET METAL DUCT AND DIFFUSER <br />NECK WITH NYLON TIES. INTERIOR <br />LINER AND EXTERIOR INSULATION OF <br />FLEX DUCT TO BE TIED INDIVIDUALLY. <br />INSTALL USING TEN510NING TOOL AS <br />PER MANUFACTURER'S <br />RECOMMENDATIONS. <br />NYLON TIE ON EXTERIOR INSULATION <br />NYLON TIE ON INTERNAL LINER <br />INTERIOR LINER <br />PREIN5ULATED FLEXIBLE <br />DUCTWORK. SEE <br />SPECIFICATIONS. LENGTH <br />SHALL NOT EXCEED 8'-0" <br />PROVIDE SUPPORT PER <br />SMACNA STANDARDS. <br />INSTALL FREE OF KI NK5 <br />SAGS. <br />DAMPER HERE FOR <br />INACCESSIBLE CEILINGS <br />(I.E. HARD CEILINGS) <br />J PROVIDE FACTORY, <br />f PRE -MOLDED INSULATION <br />BLANKET ON DIFFUSER <br />BACKPLATE <br />SUPPLY DIFFUSERV CEILING <br />SEE ARCH. <br />WHERE BRANCH DUCT SIZE DIFFERS FROM <br />SCHEDULED DIFFUSER NECK SIZE, CONTRACTOR <br />SHALL PROVIDE NECESSARY TRANSITION. <br />DUCTWORK DETA I US <br />NO SCALE <br />5-CLIP JOINT OR <br />ADHESIVE GASKET <br />FITTING <br />450 <br />LATERAL��' <br />TEE <br />O <br />i <br />O <br />� <br />ROUND <br />- ROUND <br />CONICAL TEE <br />Al RFLOW <br />O <br />�— <br />oL <br />Q <br />M.V.D. <br />RECTANGULAR - <br />ROUND <br />M.V.D. <br />Al RFLOW <br />X I <br />4— <br />Q <br />--I X2 <br />WHERE: <br />X2 = (I /4)'(X 1), 4" MIN. <br />RECTANGULAR <br />- RECTANGULAR <br />SPECIFICATIONS <br />SHOP DRAWINGS: <br />SUBMIT SHOP DRAWINGS FOR REVIEW. PDF FILES PREFERRED. SHOP DRAWINGS SHALL BE <br />BOUND INTO VOLUMES (FILES), WITH EACH VOLUME (FILE) CONTAINING ONE COPY OF ALL <br />SHOP DRAWINGS. ALL SHOP DRAWINGS SHALL BE SUBMITTED SIMULTANEOUSLY; NO SHOP <br />DRAWINGS WILL BE CHECKED UNTIL ALL HAVE BEEN SUBMITTED. <br />SUBMITTALS SHALL BE SUPPORTED BY DESCRIPTIVE MATERIAL, SUCH AS CATALOG CUTS, <br />DIAGRAMS, PERFORMANCE CURVES AND CHARTS PUBLISHED BY THE MANUFACTURER, TO <br />SHOW CONFORMANCE TO SPECIFICATION' AND DRAWING REQUIREMENTS; MODEL NUMBERS <br />ALONE WILL NOT BE ACCEPTABLE. ALL LITERATURE SHALL CLEARLY INDICATE THE SPECIFIED <br />MODEL NUMBER, DIMENSIONS, ARRANGEMENT, RATING AND CHARACTERISTICS OF THE <br />PROPOSED EQUIPMENT. CAPACITIES AND RATINGS SHALL BE BASED ON CONDITIONS <br />INDICATED OR 5PECIFIED HEREIN. ANY DEVIATIONS FROM SPECIFIED EQUIPMENT <br />(PARTICULARLY THOSE WHICH REQUIRE COORDINATION WITH OTHER TRADES) SHALL BE <br />CLEARLY NOTED IN A CONCISE LIST ON A SEPARATE SHEET. <br />TEST AND BALANCE: <br />THE CONTRACTOR SHALL RETAIN THE SERVICES OF AN INDEPENDENT TEST AND BALANCE <br />AGENCY THAT IS INDEPENDENT OF ANY CONTRACTOR RA R R SUB CONT CTO OMANUFACTURER <br />TO PERFORM THE TESTING AND BALANCING AND PREPARE REPORTS TO THE GENERAL <br />CONTRACTOR. THE INDEPENDENT TEST AND BALANCE AGENCY SHALL HAVE A CERTIFIED <br />MEMBER OF THE NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEBB). <br />TEST AND BALANCE SHALL ALSO PROVIDE QUOTE TO PERFORM BALANCING FOR COMFORT SIX <br />MONTHS AFTER THE SPACE IS OCCUPIED. <br />P-TAB.COM OR EQUIVALENT. <br />GUARANTEE THAT EACH PIECE OF APPARATUS SHALL BE OF THE CUSTOMARY STANDARD AND <br />QUALITY FURNISHED BY THE DESIGNED MANUFACTURER FOR THAT CATALOG NUMBER. <br />GUARANTEE THAT THE AIR SYSTEMS SHALL OPERATE WITHOUT AERODYNAMIC NOISE <br />GENERATED FROM THE FAULTY INSTALLATION OF DUCT WORK OR ANY COMPONENT OF THE <br />AIR DISTRIBUTION SYSTEM. <br />GUARANTEE THAT ALL SYSTEMS AND COMPONENTS SHALL BE PROVIDED WITH A ONE YEAR <br />WARRANTY FROM THE TIME OF DATE OF SUBSTANTIAL COMPLETION. THE WARRANTY SHALL <br />COVER ALL MATERIALS AND WORKMANSHIP DURING THIS WARRANTY PERIOD, ALL DEFECTS IN <br />MATERIALS AND WORKMANSHIP SHALL BE CORRECTED BY REPAIR OR REPLACEMENT WITHOUT <br />INCURRING ADDITION'S TO THE CONTRACT, <br />GENERAL NOTES: <br />REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF ALL CEILING <br />MOUNTED EQUIPMENT. <br />ALL DUCT DIMENSIONS INDICATED IN THESE DOCUMENTS ARE INSIDE -CLEAR DIMENSIONS. <br />PORTIONS OF DUCTWORK OR PIPING VISIBLE THROUGH GRILLES AND REGISTERS IN FINISHED <br />AREAS SHALL BE PAINTED FLAT BLACK. PAINT BLACK BEHIND ALL GRILLES. <br />ALL WIRING IN THE CEILING PLENUM SHALL BE PLENUM RATED CABLE. <br />MOUNTING FRAME OF CEILING MOUNTED AIR DISTRIBUTION DEVICES SHALL BE COMPATIBLE <br />WITH CEILING TYPE. REFER TO ARCHITECTURAL DRAWINGS FOR CEILING TYPE. <br />ALL FIRE SEPARATIONS MUST BE PROTECTED WHEN APPLICABLE. <br />PROVIDE NEW FILTERS (MERV 7 OR BETTER PER OWNER) FOR ALL APPLICABLE HVAC <br />EQUIPMENT AT THE END OF CONSTRUCTION. <br />ALL MATERIAL IN PLENUM MUST MEET FIRE AND SMOKE SPREAD AS REQUIRED BY NFPA 90A. <br />ALL ROOF PENETRATIONS TO BE 1 2" APART AND AT LEAST 1 2" AWAY FROM CURBS, WALLS, <br />AND DRAIN SUMPS TO PROVIDE ROOFING CONTRACTOR WITH SUFFICIENT ACCESS FOR <br />FLASHING EACH ROOF PENETRATION. <br />SUBSTITUTIONS MUST BE APPROVED IN WRITING BY ARCHITECT PRIOR TO BID SUBMISSION. <br />CONTRACTOR SHALL REVIEW ALL CONTRACT DOCUMENTS AND SHALL BE FAMILIAR WITH THE <br />SCOPE AND REQUIREMENTS OF THIS PROJECT. ANY DISCREPANCIES OR LACK. OF CLARITY IN <br />THE DOCUMENTS SHALL BE IDENTIFIED TO THE ARCHITECT OR ENGINEER PRIOR TO THE <br />5UBMI55ION OF PRICING BIDS. WITH A SUBMITTED BID, CONTRACTOR 15 ACCEPTING THESE <br />DOCUMENTS AS SUFFICIENT DEFINITION OF THE SCOPE OF WORK, AND ANY ADDITIONAL <br />COSTS BASED ON UNCLAKITY OF CONTRACT DOCUMENTS WILL NOT BE CONSIDERED. <br />THE CONTRACTOR SHALL REFERENCE THE FULL SET OF CONSTRUCTION DOCUMENTS DURING <br />PRICING AND CONSTRUCTION FOR COORDINATION BETWEEN DISCIPLINES RELATIVE TO THE <br />MECHANICAL SCOPE. <br />DUCTWORK AND ACCESSORIES: <br />INDUSTRY STANDARDS: COMPLY WITH 5MACNA (SHEET METAL AND AIR CONDITIONING <br />CONTRACTORS' NATIONAL ASSOCIATION) HVAC DUCT CONSTRUCTION STANDARDS, <br />RECOMMENDATIONS FOR FABRICATION, GAUGES, CONSTRUCTION AND DETAILS, AND <br />INSTALLATION PROCEDURES, EXCEPT AS OTHERWISE INDICATED. <br />COMPLY WITH ASHRAE (AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR <br />CONDITIONING ENGINEERS) FUNDAMENTALS HANDBOOK RECOMMENDATIONS, EXCEPT AS <br />OTHERWISE INDICATED, <br />DUCTWORK METAL AND GAUGES: EXCEPT AS OTHERWISE INDICATED, FABRICATE DUCTWORK <br />FROM GALVANIZED SHEET STEEL COMPLYING WITH ASTM A527, LOCKFOKMING QUALITY, WITH <br />ASTM A525 GOO ZINC COATING, MILL PH05PHATIZED, GAUGES TO COMPLY WITH SMACNA <br />STANDARDS. <br />DUCT SEALANT: NON -HARDENING, NON -MIGRATING MASTIC OR LIQUID ELASTIC SEALANT (TYPE <br />APPLICABLE FOR THE FABRICATION/INSTALLATION DETAIL) AS COMPOUNDED AND <br />RECOMMENDED BY THE MANUFACTURER SPECIFICALLY FOR SEALING JOINTS AND SEAMS IN <br />DUCTWORK <br />DUCTWORK SUPPORT MATERIALS: EXCEPT AS OTHERWISE INDICATED, PROVIDE UPPER <br />ATTACHMENT, HANGERS OF GALVANIZED STEEL STRAPS, OR STEEL RODS AND LOWER <br />ATTACHMENT FOR SUPPORT OF DUCTWORK. HANGING/SUPPORT 5Y5TEM5 SHALL BE IN <br />ACCORDANCE WITH SMACNA REQUIREMENTS. <br />EXPOSED DUCTWORK SHALL BE DOUBLE -WALL SPIRAL PIPE WITH PAINT GRIP UNLESS <br />OTHERWISE NOTED OR SUBSTITUTION APPROVED BY OWNER. <br />VOLUNTARY ALTERNATE EXPOSED DUCTWORK SHALL BE SINGLE -WALL SPIRAL PIPE UNLESS <br />OTHERWISE NOTED OR 5UB5TITUTION APPROVED BY OWNER. ALL EXPOSED DUCTWORK <br />SHALL BE LINED IN LIEU OF WRAPPED. DUCT LINER THERMAL RESISTANCE SHALL MEET THE <br />MINIMUM VALUES SPECIFIED IN PARAGRAPH 'DUCT INSULATION' BELOW. <br />DUCT INSULATION: <br />K-5 SUPPLY, OUTSIDE AND RETURN AIR DUCT INSULATION IN UNCONDITIONED SPACES <br />K-8 SUPPLY AND RETURN AIR DUCT INSULATION OUTSIDE THE BUILDING <br />K-8 INSULATION BETWEEN DUCTS AND THE BUILDING EXTERIOR WHEN DUCTS ARE PART OF A <br />BUILDING ASSEMBLY <br />SPECIFICATIONS <br />DIFFUSERS, GRILLES, 4 REGISTERS: <br />EGGCRATE GRILLE: <br />RETURN GRILLES SHALL BE TITUS MODEL 50F FOR THE SIZES AND MOUNTING TYPES AS <br />SHOWN ON THE PLANS AND OUTLET SCHEDULE. RETURN GRILLES MUST PROVIDE A FREE AREA <br />OF AT LEAST 90%. OUTER BORDERS SHALL BE CONSTRUCTED OF HEAVY EXTRUDED <br />ALUMINUM WITH A THICKNESS OF O.040-0.050 INCH AND SHALL HAVE COUNTERSUNK <br />SCREW HOLES FOR A NEAT APPEARANCE. BORDER WIDTH SHALL BE I %4 INCHES ON ALL SIDES <br />AND SHALL BE INTERLOCKED AT THE FOUR CORNERS AND MECHANICALLY STAKED TO FORM A <br />RIGID FRAME. CHOICE OF THREE SIZES OF ALUMINUM GRID: V2 X /2 X %2 INCH, �/2 X %2 X I <br />INCH, OR I X I X I INCH SHALL BE AVAILABLE. <br />OPTIONAL OPPOSED -BLADE VOLUME DAMPER SHALL BE CONSTRUCTED OF HEAVY GAUGE <br />STEEL OR ALUMINUM. DAMPER MUST BE OPERABLE FROM THE FACE OF THE GRILLE. <br />PLAQUE DIFFUSERS: <br />ARCHITECTURAL SQUARE PANEL CEILING DIFFUSERS SHALL BE OF THE SIZES AND MOUNTING <br />TYPES SHOWN ON THE PLANS AND OUTLET SCHEDULE. THE FACE PANEL IS REMOVABLE BY <br />OF F MEANS O OUR HANGER BRACKETS. THE EXPOSED SURFACE O THE FACE PANEL SMALL BE <br />SMOOTH, FLAT, AND FREE OF VISIBLE FASTENERS. <br />THE BACK OF THE FACE PANEL SHALL HAVE AN AERODYNAMICALLY SHAPED, ROLLED EDGE TO <br />ENSURE A TIGHT HORIZONTAL DISCHARGE PATTERN. CEILING DIFFUSERS WITH A 24 X 24-INCH <br />FULL FACE SHALL HAVE NO LESS THAN AN 18 X 18-INCH FACE PANEL SIZE. CEILING DIFFUSERS <br />WITH A 12 X 12-INCH FULL FACE SHALL HAVE NO LESS THAN A 9 X 9-INCH FACE PANEL SIZE. <br />THE 13ACKPAN SHALL BE ONE PIECE PRECISION DIE -STAMPED AND SHALL INCLUDE AN <br />INTEGRALLY DRAWN INLET. THE DIFFUSER NECK SHALL HAVE A MINIMUM OF 1 �/4-INCH DEPTH <br />AVAILABLE FOR DUCT CONNECTION, <br />THE FINISH SHALL BE #2G WHITE. THE FINISH SHALL BE AN ANODIC ACRYLIC PAINT, BAKED AT <br />3 1 5°F FOR 30 MINUTES. THE PENCIL HARDNESS MUST BE HB TO H. <br />THE PAINT MUST PASS A 100-HOUR A5TM B 1 17 CORROSIVE ENVIRONMENTS SALT _`)PRAY <br />TEST WITHOUT CREEPAGE, BLISTERING OR DETERIORATION OF FILM. THE PAINT MUST PASS A <br />250-HOUR ASTM D870 WATER IMMERSION TEST. THE PAINT MUST ALSO PASS THE ASTM <br />D2794 REVERSE IMPACT CRACKING TEST WITH A 50-INCH POUND FORCE APPLIED. <br />OPTIONAL ROUND DAMPER SHALL BE CONSTRUCTED OF HEAVY GAUGE STEEL. DAMPER MUST <br />BE OPERABLE FROM THE FACE OF THE DIFFUSER. OPTIONAL DIRECTIONAL BLOW CLIPS SHALL <br />BE AVAILABLE TO RESTRICT THE DISCHARGE AIR IN CERTAIN DIRECTIONS. <br />OPTIONAL MOLDED INSULATION BLANKET SHALL BE AVAILABLE. THE INSULATION WILL BE K-G, <br />FOIL -BACKED, AND PROVIDE AN ADDITIONAL I -INCH GAP AROUND THE NECK TO INSTALL <br />INSULATED FLEX DUCT. <br />THE MANUFACTURER SHALL PROVIDE PUBLISHED PERFORMANCE DATA FOR THE SQUARE <br />PANEL DIFFUSER. THE DIFFUSER SHALL BE TESTED IN ACCORDANCE WITH AN5I/A5HRAE <br />STANDARD 70- 199 1 . <br />CEILING FAN: <br />CEILING MOUNTED EXHAUST FANS SHALL BE OF THE CENTRIFUGAL DIRECT DRIVE TYPE. THE <br />FAN HOUSING SHALL BE CONSTRUCTED OF STEEL. THE PLASTIC DUCT COLL\K SHALL BE A <br />TAPERED SLEEVE FOR EASE OF CONNECTION TO 3 IN AND 4 IN ROUND DUCTWORK AND SHALL <br />INCLUDE A BACKDKAFT DAMPER. THE GRILLE SHALL BE CONSTRUCTED OF NON -YELLOWING <br />HIGH STRENGTH POLYMER AND ATTACHED TO THE HOUSING WITH TORSION SPRINGS. THE <br />WHEELS SHALL BE CONSTRUCTED OF HIGH STRENGTH POLYMER. THE ACCESS FOR WIRING <br />SHALL BE EXTERNAL. THE MOTOR DISCONNECT SHALL BE INTERNAL AND OF THE PLUG IN TYPE. <br />ALL FANS SHALL BEAR THE AMCA CERTIFIED RATINGS SEALS FOR SOUND AND AIR <br />PERFORMANCE AND SHALL BE U.L. LISTED. <br />W -h <br />2 <br />9 o <br />U .N <br />0" <br />PROFICIENT �O <br />Q a �=pz <br />z ¢m� <br />E N G I N E E R I N G¢ <br />6991 Peachtree Industrial Blvd Building 700 ¢ � 0 5 <br />Peachtree Corners, Georgia 30092 = "� D. <br />w <br />W 3g°'=- <br />404.330.9798 (D g W i a <br />PROJECT # 118166 o m _ <br />LU u �ozLL <br />cD GZ 40 <br />9 <br />' * : No. T0,199 <br />FLORIDN .a� ,,. <br />G� <br />"411nu11111u10a�. <br />x <br />0 <br />w <br />N <br />It <br />02 <br />(y) p <br />QU <br />D ~ <br />Z <br />Q9 <br />F_ <br />Q � <br />J W N <br />LL 04 <br />LL <br />Q W C4 <br />Lll C <br />Z (8)(10. <br />i <br />It <br />< z .t <br />w O� <br />Q <br />Uw <br />D LL <br />LL <br />L.L <br />> _ <br />h U) <br />L0 <br />It <br />IQ OT-, M-L'U°E IONS <br />y <br />Z <br />O 0 'it_ U Q co <br />LL ILL <br />Cl) °w <br />_jm-j <br />O J = <br />Cn <br />0-oa <br />N tiN <br />M-2 <br />04-09-2018 <br />