7821 Gall Blvd (2)
Zephyrhills
>
Building Department
>
Building Plans
>
7821 Gall Blvd (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 11:12:14 AM
Creation date
2/19/2025 8:34:40 AM
Metadata
Fields
Template:
Building Plans
Street #
7821
Location
Gall Blvd
Contractor
Borregard Construction
Building Plans - Permit #
3504
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IT IS CRITICAL TO ROUTE THE GREASE DUCT STRAIGHT VERTICAL <br />Floor (+0.00"AFF) <br />SYSTEM DESIGN VERIFICATION (SDV) <br />IF ORDERED, CAS SERVICE WILL PERFORM A SYSTEM DESIGN VERIFICATION (SDV) ONCE ALL EQUIPMENT HAS HAD A COMPLETE START UP PER THE OPERATION AND INSTALLATION <br />MANUAL. TYPICALLY, THE SDV WILL BE PERFORMED AFTER ALL INSPECTIONS ARE COMPLETE. <br />ANY FIELD RELATED DISCREPANCIES THAT ARE DISCOVERED DURING THE SDV WILL BE BROUGHT TO THE <br />ATTENTION OF THE GENERAL CONTRACTOR AND CORRESPONDING TRADES ON SITE. THESE ISSUES <br />WILL BE DOCUMENTED AND FORWARDED TO THE APPROPRIATE SALES OFFICE. IF CAS SERVICE HAS TO <br />RESOLVE A DISCREPANCY THAT IS A FIELD ISSUE, THE GENERAL CONTRACTOR WILL BE NOTIFIED AND <br />BILLED FOR THE WORK. SHOULD A RETURN TRIP BE REQUIRED DUE TO ANY FIELD RELATED DISCREPANCY THAT CANNOT BE RESOLVED DURING THE SDV, THERE WILL BE ADDITIONAL TRIP <br />CHARGES. <br />DURING THE SDV, CAS SERVICE WILL ADDRESS ANY DISCREPANCY THAT IS THE FAULT OF THE MANUFACTURER. SHOULD A RETURN TRIP BE REQUIRED, THE GENERAL CONTRACTOR AND <br />APPROPRIATE SALES OFFICE WILL BE NOTIFIED. THERE WILL BE NO ADDITIONAL CHARGES FOR MANUFACTURER DISCREPANCIES. <br />DO NOT LEAK TEST USING SMOKE BOMBS CONTAINING <br />CHLORINES/CHLORIDES. CONSULT WITH CAPTIVEAIRE <br />FOR PROPER LEAK TESTING METHODS. <br />GREASE DUCT BCHIMNEY SPECIFICATIONS: <br />PROVIDE GREASE DUCT EQUAL TO CAPTIVEAIRE SYSTEMS MODEL "DW" <br />ROUND 20 GAUGE 430 STAINLESS STEEL DUCTWORK MODEL "DW" <br />IS LISTED TO UL-1978 AND IS INSTALLED USING "V" CLAMP LOCKING <br />CONNECTIONS SEALED WITH 3M FIRE BARRIER 2000 PLUS. MODEL "DW" <br />DOES NOT REQUIRE WELDING PROVIDING IT HAS BEEN INSTALLED PER <br />THE MANUFACTURES INSTALLATION GUIDE. <br />PROVIDE RATED ACCESS DOORS AT EVERY CHANGE IN DIRECTION AND EVERY 12' ON CENTER. PER MANUFACTURES LISTING MODEL "DW" HORIZONTAL RUNS LESS THAN <br />75 FT. CAN BE SLOPED 1116" PER 12", HORIZONTAL RUNS MORE THAN 75 FT. CAN BE SLOPED 3116" PER 12". <br />DUCT SHOULD BE SLOPED AS MUCH AS POSSIBLE TO REDUCE THE CHANCE OF GREASE ACCUMULATION IN HORIZONTAL RUNS. <br />IF THE DUCT OR CHIMNEY IS WITHIN 18INCHES OF COMBUSTIBLE MATERIAL, PROVIDE UL-2221 OR UL-103 HT LISTED DOUBLE WALL GREASE DUCT OR DOUBLE WALL <br />CHIMNEY EQUAL TO CAPTIVEAIRE SYSTEMS MODEL "DW- 2R, 211 TYPE HT, 3R, OR 3Z" ROUND 20 GAUGE 430 STAINLESS INNER DUCT INSULATED WITH A 24 GAUGE 430 <br />STAINLESS OUTER SHELL. <br />CAPTIVEAIRE SYSTEMS RECOMMENDS THE USE OF LISTED, PRE -FABRICATED ROUND <br />GREASE EXHAUST DUCT TO REDUCE STATIC PRESSURE IN THE SYSTEM, MINIMIZE <br />INSTALLATION AND INSPECTION TIMES, AND ENSURE DUCT IS LIQUID TIGHT <br />HVAC DISTRIBUTION NOTE <br />HIGH VELOCITY DIFFUSERS OR HVAC RETURNS SHOULD NOT BE PLACED WITHIN TEN <br />(10) FEET OF THE EXHAUST HOOD. PERFORATED DIFFUSERS ARE RECOMMENDED. <br />REVISIONS <br />E <br />n <br />........ <br />Robert E. Gregg FL #9927 <br />SKY #3396 <br />CT #8153 <br />CC #4334 <br />NJ 415414 <br />i'.;1S t2335 <br />1 � 4a737 <br />OH 45898 <br />TN #4334 <br />Copy of this plan is not valid unless <br />signed, sealed and dated by the <br />architect of record <br />Copywrite: <br />This drawing is the property of <br />R.E. Gregg Architects and under no <br />circumstances may this drawing be <br />reproduced, published, altered or used <br />in any way without written authorization <br />from R.E. Gregg Architects. <br />Contractor shall check and <br />verify all dimensions and <br />coordinate all field conditions. <br />All discrepancies and conflicts <br />shall be reported to the architect <br />in writing prior to proceeding or <br />continuing with construction. <br />Unreported discrepances and <br />conflicts shall remain the <br />responsibility of the contractor. <br />z <br />oM <br />J <br />LL <br />W <br />W <br />U3 <br />043 <br />ZD <br />Jc <br />—17 <br />L. <br />JC <br />z <br />J <br />Q <br />0— <br />N <br />_ <br />N <br />N <br />� <br />_ <br />z <br />ti <br />O <br />M <br />U_ <br />U <br />DRAWN BY: <br />KG <br />CHECKED BY: <br />REG <br />N <br />C- <br />� <br />N <br />ISSUE DATE: <br />1-12-2022 <br />DATE:12/16/2021 <br />REVISIONS: <br />DWG.#: <br />5198383 <br />DRAWN <br />Y: celso.saenz <br />SCALE: <br />3/4" = 1 '-0' <br />MASTER DRAWING <br />SHEET NO. <br />4 <br />PLAN <br />Min <br />