My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7821 Gall Blvd (2)
Zephyrhills
>
Building Department
>
Building Plans
>
7821 Gall Blvd (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 11:12:14 AM
Creation date
2/19/2025 8:34:40 AM
Metadata
Fields
Template:
Building Plans
Street #
7821
Location
Gall Blvd
Contractor
Borregard Construction
Building Plans - Permit #
3504
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WALL MOUNTED FIRE <br />EXTINGUISHER, SEE FLOOR PLAN <br />LU <br />W <br />Z <br />x <br />NOTE: <br />LL <br />FOR FIRE EXTINGUISHER IN WALL <br />CABINET, TOP OF EXTINGUISHER <br />4 <br />0 <br />NOTTOEXCEEDR—A.F.F. <br />II <br />0 <br />W <br />\ <br />U <br />o <br />/ <br />BOTTOM OF FIRE EXTINGUISHER <br />NOT TO BE LOWER THAN 4" A.F.F. <br />FLOOR LINE <br />FIRE EXTINGUISHER DETAIL <br />1. FINAL LOCATION OF FIRE EXTINGUISHERS TO BE DETERMINED BY FIRE <br />MARSHAL. <br />2. SHALL BE LOCATED SO THAT THE MAXIMUM TRAVEL DISTANCE FROM <br />ANY POINT TO THE NEAREST EXTINGUISHER IS LESS THAN 75 FT. <br />3. TO CONFORM TO THE (NFPA) NATIONAL FIRE PROTECTION ASSOCIATION, <br />PUBLICATION #10. <br />OCCUPANCY LOAD CALCULATIONS <br />TYPE OF CONSTRUCTION: INTERIOR BUILD OUT TO <br />ASSEMBLY SPACE <br />TOTAL AREA: 1540 SQ. FT. <br />TYPE OF OCCUPANCY: A-2 <br />TABLE 1004.1.1 <br />KITCHEN (200 GROSS) <br />510 SF 1200 = 3 PERSONS <br />PATRON AREA (15 NET) <br />432115 = 29 PERSONS <br />TOTAL = 32 PERSONS <br />NUMBER OF EXITS PROVIDED = 2 <br />LIFE SAFETY LEGEND <br />FIRE EXTINGUISHER MOUNTED ON MANUFACTURER'S <br />STANDARD BRACKET (SEE DETAIL) <br />CEILING MOUNTED LED EXIT SIGN <br />CEILING MOUNTED LED EXIT SIGN / EMERGENCY LIGHT <br />1-BULB EMERGENCY LED BATTERY LIGHT <br />2- BULB EMERGENCY LED BATTERY LIGHT <br />PRIMARY MEANS OF EGRESS <br />STATE OF FLORIDA FIRE PREVENTION CODE 2017 NFPA 101 LIFE SAFETY CODE 2012 <br />7.2 MEANS OF EGRESS COMPONENTS <br />7.2.1.2.3 Minimum Width. <br />Door openings in means of egress shall be not less than 32 in. (81 cm) in clear width. Where a <br />pair of doors is provided, not less than one of the doors shall provide not less than a 32-in. <br />(81-cm) dear width opening. <br />7.2.1.3 Floor Level. <br />The elevation of the floor surfaces on both sides of a door shall not vary by more than 114in. <br />(1.3 cm). The elevation shall be maintained on both sides of the doorway for a distance not <br />less than the width of the widest leaf. Thresholds at doorways shall not exceed ''Y2 in. (1.3 cm) <br />in height. Raised thresholds and floor level changes in excess of'% in. (0.64 cm) at doorways <br />shall be bevelled with a slope not steeper than 1 in 2.7.5 <br />ARRANGEMENT OF MEANS OF EGRESS <br />7.5.1.1 Exits shall be located, and exit access shall be arranged, so that exits are readily accessible at <br />all times. <br />7.5.1.2 Corridors shall provide exit access without passing through any intervening rooms other than <br />corridors, lobbies, and other spaces permitted to be open to the corridor, unless otherwise <br />provided in 7.5.1.2.1 and 7.5.1.2.2.. <br />7.5.1.3.1 Where more than one exit, exit access, or exit discharge is required from a building or portion <br />thereof, such exits, exit accesses, or exit discharges shall be remotely located from each other <br />and be arranged to minimize the possibility that more than one has the potential to be blocked <br />by any one fire or other emergency condition.. <br />LIFE SAFETY NOTES: <br />1. COORDINATE LOCATION OF EXIT SIGNS & EMERGENCY LIGHTING <br />WITH ELECTRICAL DRAWINGS <br />2, PORTABLE FIRE EXTINGUISHERS TO MEET REQUIREMENTS OF NFPA <br />10, LATEST EDITION <br />M <br />M <br />rt�hn E � <br />v+! M J y <br />U >O <br />`JO <br />r UM Z <br />W� <br />_ o <br />0 <br />il <br />X <br />LIFE SAFETY PLAN <br />SCALE: 3116" =1'-0" <br />Robert E. Gregg FL #9927 <br />KY #3396 CT #8153 <br />SC #4334 NJ «15414 <br />MS #2335 CIA #6737 <br />OH #5898 TN *4334 <br />Copy of this plan is not valid unless <br />signed, sealed and dated by the <br />architect of record <br />Copywrite: <br />This drawing is the property of <br />R.E. Gregg Architects and under no <br />circumstances may this drawing be <br />reproduced, published, altered or used <br />in any way without written authorization <br />from R.E. Gregg Architects. <br />Contractor shall check and <br />verify all dimensions and <br />coordinate all field conditions. <br />All discrepancies and conflicts <br />shall be reported to the architect <br />in writing prior to proceeding or <br />continuing with construction. <br />Unreported discrepances and <br />conflicts shall remain the <br />responsibility of the contractor. <br />o <br />L.- <br />W <br />W <br />043 <br />U3 <br />Z <br />Q <br />= <br />CD <br />0— <br />_ <br />W <br />� <br />N <br />CV <br />00 <br />ti <br />DRAWN BY: KG <br />CHECKED BY: REG <br />ISSUE DATE: 1-12-2022 <br />REVISIONS: <br />PLANS <br />G005 <br />
The URL can be used to link to this page
Your browser does not support the video tag.