Laserfiche WebLink
L® <br />O <br />O <br />TYPICAL NC UNIT <br />24V POWER <br />® Q 6 7 8 <br />WIRE IN SERIES <br />MTH ALL OTHER <br />SMOKE DETECTORS <br />AND ANSUL SYS. <br />ROUTE TO A/C TERMINALS <br />LOCATED IN CONTROL PANEL <br />TERMINALS <br />wI1T I I <br />GRN BLK RED <br />�4\18AW <br />16 t97 18 <br />FITS A 2-GANG WALL BOX <br />o ?cs d <br />ALARM PILOT RESET <br />ROUTE TO ALARM ANNUNCIATOR PANEL <br />USE 41COND. 20 AWG CABLE <br />SMOKE DETECTOR SCHEDULE <br />COMPONENT <br />MODEL <br />MANUFACTURER <br />SMOKE DETECTOR <br />RW UNI-N <br />SUNCOAST ENVIRONMENTAL CONTROLS OR EQUIVALEN <br />ANNUNCIATOR <br />AP-1 <br />SUNCOAST ENVIRONMENTAL CONTROLS (OR EQUIVALENT) <br />CONDUCTOR <br />4COND.I8AWG <br />STRANDED BC <br />SHIELDED PVC <br />CONNECT AIR INTERNATIONAL (OR EQUIVALENT) <br />CONTROLSEQUENCE <br />ANNUNCIATOR SHALL PROVIDE AUDIBLE AND VISUAL INDICATION UPON ACTIVATION OF SMOKE DETECTOR AND UPON TROUBLE CONDITION. ANNUNCIATOR SHALL PROVIDE <br />REMOTE TEST AND RESET FUNCTIONS. <br />SMOKE DETECTOR <br />CL OF JOIST (SEE PLAN)\ <br />L4" x 4" x 3/8" <br />(TYP) <br />JOIST TOP CORD <br />L4" x 4" x 1/4" <br />OPENING SIZE - SEE x 0'4" LONG <br />PLAN AND VERIFY W/ (x4) INCREASE <br />TRADE INVOLVED 1 FOR RTU FRAME <br />NP' 3M6� ANGLES ASREQ'D <br />RTU FRAME SCHEDULE <br />UNIT WEIGHT <br />ANGLE SIZE <br />0 - 675 Ibs <br />L4x3xl/4" <br />676-15001bs <br />L443/8" <br />1501-30001bs <br />L6x43/8" <br />3001-6000lbs <br />L6x6x3/8" <br />NOTES: <br />1. LOCATE L4" X 4" X 3/8" FRAMES AROUND ALL ROOF OPENINGS <br />U.N.O. REFER TO MECHANICAL CURB FRAMING DETAIL FOR <br />EQUIPMENT FRAME ANGLE SIZE. <br />2. CONTRACTOR SHALL VERIFY LOCATION AND SIZE OF <br />OPENINGS PRIOR TO STEEL FABRICATION <br />3• FRAME IS REQUIRED FOR ALL OPENINGS 12" AND GREATER <br />3 ROOF REINFORCEMENT DETAIL <br />MECH UNIT <br />#6 TEK SCREWS 12" OC <br />EACH SIDE <br />PREENGINEERED <br />CURB w/ 2x2 PT <br />NAILER <br />ROOFING <br />3/8" BOLTS w/ WASHERS @ DECKING <br />EA CORNER AND 24" OC ANGLES AS NOTED <br />PARTIAL SECTION <br />4 TYP ROOF CURB TO CONDENSER UNIT <br />MECHANICAL SYMBOLS <br />2' X 2' CEILING DIFFUSER, SUPPLY <br />: <br />MANUAL VOLUME DAMPER <br />El <br />2' X 2' CEILING DIFFUSER, RETURN <br />M.D. <br />O <br />7-DAY PROGRAMMABLE <br />CEILING DIFFUSER, SUPPLY <br />THERMOSTAT <br />O <br />HVAC RESET <br />SIDE DIFFUSER, SUPPLY <br />REMOTE SENSOR <br />EXTERIOR WALL CAP <br />FLEX DUCT -SUPPLY <br />■ <br />EXHAUST FAN <br />��.. ■ ■ ■ ■ ■ ■ <br />FLEX DUCT - RETURN <br />S/D <br />SMOKE DETECTOR <br />HARD DUCT - SUPPLY <br />(PROVIDE IF NOT EXSITING <br />■ ■ ■ ■ HARD DUCT - RETURN <br />EXHAUST FAN SCHEDULE <br />MARK <br />MODEL # <br />CFM's <br />Amps <br />Duct Dia <br />EF-1 <br />BROAN 684 <br />80 <br />.5 <br />4 <br />OUTSIDE AIR CALCULATIONS <br />VENTILATION PER ASHRAE STD 62.1 <br />2010 ADDITIONS <br />DINING ROOM <br />15 PEOPLE @ 7.5 CFM EACH = 113 <br />468 SF x 0.18 = 85 <br />TOTAL = 198 CFM <br />KITCHEN <br />3 PEOPLE @ 7.5 CFM EACH = 23 <br />251 SFx0.13= 33 <br />TOTAL = 76 CFM <br />SERVING AREA <br />3 PEOPLE @ 7.5 CFM EACH = 22 <br />259 SF x 0.18 = 47 <br />TOTAL = 69 CFM <br />TOTAL = 325 CFM <br />ROOFTOP UNIT A/C SCHEDULE <br />GOODMAN GPC146OH41 <br />COOLING BTUS - 57500 BTU <br />COOLING TONNAGE - 5 TONS <br />SEER - 14.2 SEER COOLING <br />CFM - 2000 (HIGH / LOW) <br />ELECTRIC HEAT CAPABILITIES - 10115 / 20 / 5 / 8 KILOWATTS <br />NOMINAL CFM - 2000 <br />REFRIGERANT- R410A <br />MAXIMUM OVERCURRENT PROTECTION (BREAKER) - 60 AMPS <br />COMPRESSOR TYPE - SCROLL <br />NOISE LEVEL - 80 DECIBELS <br />PRODUCT WEIGHT - 370 LBS <br />SHIPPING WEIGHT - 382 LBS <br />WIDTH - 66.5 INCHES <br />DEPTH - 34 INCHES <br />HEIGHT- 38.75INCHES <br />VOLTAGE - 208 / 230 VOLTS <br />FREQUENCY - 60 HZ <br />VOLTAGE PHASE -1 <br />RTU-1 <br />5-TON <br />FIELD LOCATE <br />MAKE-UP AIR VENT 115V GFI RECEIPT IN <br />WEATHERPROOF BOX <br />(PROVIDE IF NOT EXISTING) <br />HOOD EXHAUST FAN <br />O <br />MECHANICAL ROOF PLAN <br />SCALE: 3116" = V-0" <br />RTU-2 <br />5-TON <br />FIELD LOCATE <br />MECHANICAL PLAN <br />SCALE: 3/16" = V-0" <br />M <br />pC) U <br />/E <br />Wa <br />a <br />Robert E. Gregg FL #9927 <br />KY t#3396 CT #8153 <br />SC #4334 NJ 415414 <br />MS #2835 VA #5737 <br />OH #5808 TN -4334 <br />Copy of this plan is not valid unless <br />signed, sealed and dated by the <br />architect of record <br />Copywrite: <br />This drawing is the property of <br />R.E. Gregg Architects and under no <br />circumstances may this drawing be <br />reproduced, published, altered or used <br />in any way without written authorization <br />from R.E. Gregg Architects. <br />Contractor shall check and <br />verify all dimensions and <br />coordinate all field conditions. <br />All discrepancies and conflicts <br />shall be reported to the architect <br />in writing prior to proceeding or <br />continuing with construction. <br />Unreported discrepances and <br />conflicts shall remain the <br />responsibility of the contractor. <br />Z <br />J <br />WOM L.1_ <br />W Cn Cn <br />J <br />Of 117Y, <br />(29 <br />Z Q = <br />= W <br />r— IV <br />00 <br />DRAWN BY: KG <br />CHECKED BY: REG <br />ISSUE DATE: 1-12-2022 <br />REVISIONS: <br />O <br />O <br />O <br />O <br />O <br />O <br />O <br />O <br />PLAN <br />M 101 <br />