Laserfiche WebLink
FLOOR PLAN GENERAL NOTES <br />w <br />L2 <br />111 <br />C <br />25 GUAGE 3 5/8" MTL STUD <br />BRACE - SPACED 48" O.C. <br />ALTERNATE DIRECTION <br />STRUCTURE <br />*4'-0" MIN <br />Al <br />+ RT - All PYICTINr. <br />FLOOR PLAN <br />1 /4" = 1'-0" <br />WALL ANGLE <br />CEILING, SEE RCP <br />Q <br />ACOUSTICAL INSULATION <br />a <br />AT ACOUSTICALLY RATED <br />c� <br />PARTITIONS <br />z_ <br />J_ <br />W <br />U <br />0 <br />W <br />U <br />N1 4 %/$" <br />3 5/8" 25 GUAGE METAL STUDS 24" <br />O.C. WITH 5/8" GYP BOARD EACH <br />W <br />(If <br />SIDE, (STC49 W/3" INSUL, WHERE <br />W <br />REQUIRED) <br />U) <br />ACOUSTICAL INSULATION <br />TRACK (RUNNER) ATTACHED <br />MM SND MM <br />LL <br />TO FLOOR WITH POWER <br />N <br />ACTUATED PINS @ 24" OC MAX <br />(SEE RCP) <br />v <br />r <br />s N <br />3/4" MIN EMBEDMENT <br />_ <br />Cn <br />FLOOR FINISH AND BASE, <br />a _J /ir <br />SEE FINISH SCHEDULE <br />Nu ^ <br />Y <br />1, <br />a <br />� <br />GYP1. BOARD THRU CEILING PARTITION <br />5 Ni <br />N1 <br />1. <br />CDo <br />rn <br />0 CO01 <br />PARTITION TYPE <br />N 1 <br />2 <br />C 2 <br />N <br />STRUCTURE <br />FLOOR FINISH AND BASE, <br />SEE FINISH SCHEDULE <br />THRU CEILING FURRING PARTITION <br />1"=1'-0" <br />PARTITION TYPE N2 <br />1 " = 1'-0" <br />z <br />Q <br />J <br />d <br />c� <br />z <br />J <br />W <br />U <br />0 <br />W <br />U <br />W <br />J <br />U_ <br />W <br />af <br />W <br />W <br />UL PERMITS THE REPRODUCTION OF THE MATERIAL <br />REPRINTED FROM THE UL PRODUCT DIRECTORY <br />WITH PERMISSION FROM UNDERWRITERS <br />LABORATORIES INC.@ <br />COPYRIGHT© 2007 UNDERWRITERS LABORATORIES <br />DESIGN No. U465 <br />NONBERAING WALL RATING-1 HR. <br />SCALE: 1 "=1'-0" <br />1. Floor and Ceiling Runners — (not shown) — Channel <br />shaped runners, 3-5/8 in. wide (min), 1-1/4 in. legs, formed <br />from min No. 25 MSG galv steel, attached to floor and ceiling <br />with fasteners spaced 24 in. OC max. <br />2. Steel Studs — Channel shaped, 3-5/8 in. wide (min), 1-1/4 <br />in. legs, 3/8 in. folded back returns, formed from min No. 25 <br />MSG gals steel spaced 24 in. OC max. <br />3. Batts and Blankets* — (Optional) — Mineral wool or glass <br />fiber batts partially or completely filling stud cavity. See Sheet <br />A102 ACOUSTICAL INSULATION for more information. <br />4. Gypsum Board* — 5/8 in. thick, 4 ft wide, attached to steel <br />studs and floor and ceiling track with 1 in. long, Type S steel <br />screws spaced 8 in. OC. along edges of board and 12 in. OC <br />Z <br />in the field of the board. Joints oriented vertically and <br />OO <br />staggered on opposite sides of the assembly. When attached <br />w <br />to item 6 (resilient channels) or 6A (furring channels), wallboard <br />Y m <br />is screw attached to furring channels with 1 in. long, Type S <br />Q Z <br />steel screws spaced 12 in. OC. <br />Y <br />W Q <br />AMERICAN GYPSUM CO — Types AG-C <br />U) 0- <br />BORAL GYPSUM — Types BG-C <br />CANADIAN GYPSUM COMPANY — Types AR, C, IP-X2, <br />SCX, SHX, WRC or WRX. <br />CONTINENTAL GYPSUM COMPANY — Types CG-C, <br />CG5-5, CG6-6, CG9-9, CGTC-C. <br />G-P GYPSUM CORP, SUB OF GEORGIA-PACIFIC CORP <br />—Types 5, 9, C, GPFS6. <br />LAFARGE GYPSUM, A DIVISION OF LAFARGE CORP. <br />—Types LGFC6, LGFC-C. <br />NATIONAL GYPSUM CO, CHARLOTTE, NC — Types <br />FSK-G, FSW-G. <br />NATIONAL GYPSUM CO, RIYADH, SAUDI ARABIA — <br />Types FIR OR WR. <br />PABCO GYPSUM, DIV OF PACIFIC COAST BUILDING <br />PRODUCTS INC — Type PG-C <br />REPUBLIC GYPSUM CO. — Type RG-C. <br />STANDARD GYPSUM L L C — Types SG-C. <br />TEMPLE -INLAND FOREST PRODUCTS CORP — Type <br />TG-C. <br />UNITED STATES GYPSUM CO — Type AR, C, IP-X2, <br />SCX, SHX, WRC or WRX. <br />YESO PANAMERICANO SA de CV — Type AR, C, IP-X2, <br />SCX, SHX, WRC or WRX. <br />WESTROC INC—Type WESTROC FIREBOARD. <br />4A. Gypsum Board* — (As an alternate to Items 4) — Nom <br />3/4 in. thick, 4 ft wide, installed as described in Item 4 with <br />screw length increased to 1-1/4 in. <br />CANADIAN GYPSUM COMPANY — Types AR. <br />UNITED STATES GYPSUM CO — Type AR. <br />YESO PANAMERICANO SA de CV — Type AR. <br />4B. Gypsum Board* — (As an alternate to Items 4 or 4A) — <br />Nom 3/4 in. thick, 4 ft wide, installed as described in Item 4A <br />with screw length increased to 1-1/4 in. <br />CANADIAN GYPSUM COMPANY — Types WSX. <br />UNITED STATES GYPSUM CO — Type WSX. <br />YESO PANAMERICANO SA de CV — Type WSX. <br />5. Joint Tape and Compound — Vinyl, dry or premixed joint <br />compound, applied in two coats to joints and screw heads; <br />paper tape, 2 in. wide, embedded in first layer of compound <br />over all joints. As an alternate, nominal 3/32 in. thick gypsum <br />veneer plaster may be applied to the entire surface of <br />Classified veneer baseboard. Joints reinforced. <br />6. Furring Channel — (Optional -Not Shown) — 25 MSG galy <br />steel resilient channels spaced vertically max 24 in. OC, flange <br />portion attached to each intersecting stud with 1/2 in. long type <br />S-12 panhead steel screws. <br />*Bearing the UL Classification Marking <br />PARTION TYPE N3 <br />1" = 1'-0" <br />A. GC TO INSTALL FIRE RETARDANT BLOCKING AS REQUIRED FOR ALL <br />CASEWORK, SHELVING, COUNTERTOPS, & OWNER PROVIDED EQUIPMENT. <br />B. PATCH CONCRETE SLAB AS REQUIRED TO REPAIR CONDUIT INSTALLATION. SEE <br />ELECTRICAL FOR EXTEND OF SLAB TRENCHING. <br />C. ALL DIMENSIONS ARE FINISH TO FINISH UNLESS NOTED OTHERWISE. <br />D. MAINTAIN EXISTING FIRE RATINGS AT TENANT SEPARATION WALLS DURING DEMO / <br />CONSTRUCTION ACTIVITIES. <br />E. SEE REFLECTED CEILING PLAN ON SHEET A3.1 FOR ACT LAYOUT. <br />F. ALL MILLWORK / CABINETRY PROVIDED BY FIXTURE VENDOR. <br />G. SEE INTERIOR ELEVATIONS ON SHEET A6.1 FOR ALL WALLS WHERE NO FINISH OR <br />BASE IS INDICATED. <br />H. PAINT ALL SALES FLOOR DOORS AND FRAMES (ALUMINUM STOREFRONT NOT <br />INCLUDED) TO MATCH ADJACENT WALL COLOR, USING A SEMI -GLOSS FINISH <br />UNLESS NOTED OTHERWISE. <br />J. ADD KICK PLATES ON ALL INTERIOR DOORS. ADD DOOR CLOSER AT RESTROOM <br />DOORS. <br />FLOOR PLAN KEY NOTES <br />OCENTERLINES ARE USED TO LAYOUT STORE, INCLUDING CEILING, <br />POWER / DATA, FIXTURES, ETC. AND MUST BE MARKED AND VARIFIED <br />PRIOR TO START OF CONSTRUCTION. CONTACT ARCHITECT <br />IMMEDIATELY IF THERE ARE DIMENSIONAL DISCREPANCIES. <br />2OLIGHT FIXTURE ABOVE - SEE RCP FOR LOCATION AND <br />ADDITIONAL INFORMATION. <br />OBOH - PARTIAL WORK TO BE COMPLETED IN THIS CONTRACT - OTHER <br />PORTION N.I.C. SEE A2.2, A3.1 & R1.1 <br />4O CENTER THIS FIXTURE ON (� OF SALES FLOOR. <br />OADJUST LOCATION OF POSTER RAILS AS PER ACTUAL FIELD <br />LOCATION OF EXTERIOR GLASS AND WINDOW MULLIONS. <br />FIXTURE SCHEDULE <br />QTY <br />FIXTURE <br />DESCRIPTION <br />1 <br />44"X86" Sm Comm <br />Table <br />SMALL COMMUNITY TABLE <br />1 <br />AATV-BENCH <br />AATV BENCH <br />1 <br />AATV-SML <br />AATV Small <br />1 <br />ACC-DIA <br />DIAMOND ACCESSORY FIXTURE <br />1 <br />ACC-LRG <br />ACCESSORY FIXTURE <br />1 <br />ACC-SML <br />ACCESSORY FIXTURE <br />1 <br />AT&T <br />AT&T LOGO <br />1 <br />BCW-MED <br />BACKWRAP <br />3 <br />BP <br />Blocker Panel <br />1 <br />IP-D <br />L3 - 60" IPHONE FIXTURE <br />1 <br />LT-D <br />LEARNING TABLE <br />I <br />LT-D-ADA <br />ADA LEARNING TABLE <br />2 <br />LT-S <br />LEARNING TABLE STOOL <br />2 <br />LT-S-ADA <br />ADA LEARNING TABLE CHAIR <br />1 <br />MPOS <br />MOBILE POINT OF SALE <br />1 <br />MPOS-ADA <br />MOBILE POINT OF SALE <br />11 <br />MWU-D <br />LEVEL 3 MERCHANDISE UNIT <br />2 <br />WIN-B <br />WINDOW BANNER <br />WALL & DOOR LEGEND <br />NEW CONSTRUCTION WALL <br />EXISTING WALL TO REMAIN <br />® STOREFRONT GLAZING <br />EXISTING DOOR TO REMAIN <br />NEW CONSTRUCTION DOOR <br />d <br />EXISTING DEMISING WALL <br />www.brph.com Copyright © 2014 <br />Architects, Engineers <br />2727 Paces Ferry Road I Bldg 1 1 Suite 1800 <br />Atlanta I Georgia 1 30339 <br />770-933-9242 1 770-933-9246 f <br />Offices in Melbourne, Orlando, West Palm <br />Beach, Atlanta, Charleston, Seattle <br />These plans are protected by Federal Copyright <br />protection. Unauthorized use may result in an <br />infringement action. <br />ISSUE FOR PERMIT AND CONSTRUCTION <br />REVISION L <br />J <br />m <br />OC <br />G <br />06 <br />I— <br />J <br />Q <br />W <br />U) <br />J <br />J <br />W <br />N <br />Z <br />O <br />w <br />w <br />W <br />E.-OF F<O <br />gruc��• i��O< <br />ARCH/ENGROF RECORD <br />BRUCE A. LOTT <br />AR0012048 <br />DESIGNED BY <br />BDR <br />DRAWN BY <br />KCC/ BJG <br />CHECKED BY <br />BAL <br />PROJECT NUMBER <br />C06898.057.01 <br />DATE <br />08/13/14 <br />TITLE <br />ARCHITECTURAL <br />FLOOR PLAN <br />DRAWING NO. <br />A2* <br />a <br />U 0 N <br />a U co <br />1 ! 2 3 <br />El <br />P <br />