My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7886 Gall Blvd (2)
Zephyrhills
>
Building Department
>
Building Plans
>
7886 Gall Blvd (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 11:10:24 AM
Creation date
2/19/2025 8:34:51 AM
Metadata
Fields
Template:
Building Plans
Street #
7886
Location
Gall Blvd
Contractor
Geneva Construction
Building Plans - Permit #
15209
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FLOOR PLAN GENERAL NOTES <br />10 <br />10 <br />POWER/COMMUNICATIONS REFERENCE PLAN <br />1 /4" = 1'-0" <br />3/8" = 1'-0" <br />3'-4" <br />NOTE: WIREMOLD RFB4E FLOOR BOX <br />W/ 2 HUB ACCESSORY AND 6CTBKTR <br />COVER CAN BE USED IN PLACE OF <br />THE 881RC4ATCBK IF BOX IS <br />AVAILABLE. IF USED, CONDUIT <br />WOULD TERMINATE AT BOX AND NO <br />STUB -UP THROUGH FLOOR <br />NOTE: RECEPTACLES @ BACKWRAP <br />AND LEARNING TABLE TO BE ON A <br />SINGLE 20 AMP DEDICATED <br />CIRCUIT. DO NOT ADD OTHER <br />RECEPTACLES TO CIRCUIT. <br />NOTE: IF LEARNING TABLES ARE TO <br />BE TEMPORARILY USED AS POS <br />STATIONS. THE 2" CONDUIT SHOWN <br />IN ENLARGED PLAN IS REQUIRED IN <br />ORDER TO PROVIDE THE HDMI AND <br />USB CORDS AND AMPLIFIER FROM <br />THE BACKWRAP TO THE LEARNING <br />TABLE. <br />THE HDMI, USB, AND AMPLIFIER <br />SHOULD BE ORDERED THROUGH <br />GRAINGER AS REQUIRED. <br />AREA OF WORK 5"L...-OPE <br />OF BCW <br />3'-4" <br />------------------ -- <br />OUTLE I FOR GRID GRAPHIC LIGHTING, TO BE NIGHT LIGHT <br />I I t I 1 <br />�— ---------+--r-----r-----� <br />I 1 1 I I I I I I I I <br />I I I I I I I I I 1 <br />I I I I I I I I I I I <br />I I I I I ! I I I I I <br />I I I I I I I I I I <br />21 8 2 -$ 1 <br />--—J-----1--—Q—' LQ----L— ---� I <br />I I - V" <br />---- ---_ <br />I I I I I I 1 1 <br />I u to <br />-------------+---- ------ --� FINISH FLOOR <br />2 POWER <br />4 DATA & 1 PHONE, 4 POWER <br />ELEVATION @ BCW-MED <br />3/8" = 1'-0" <br />A. GC TO PROVIDE ALL WIRING IN FULL COMPLIANCE WITH THE MOST CURRENT <br />AT&T IT STANDARDS, RFP V2.5 OR LATER. <br />B. ELECTRICAL INFORMATION SHOWN FOR REFERENCE ONLY. REFERENCE <br />ELECTRICAL DRAWINGS FOR ENGINEERING DESIGN INFORMATION. <br />C. DATA OUTLET INFORMATION SHOWN FOR LOCATION REFERENCE ONLY. <br />REFERENCE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. <br />D. PROVIDE PULL STRINGS IN ALL VOICE / DATA OUTLET CONDUIT. <br />E. GROMMET LOCATIONS TO BE COORDINATED THROUGH GC WITH OWNER. <br />F. SAWCUT AND REMOVE EXISTING SLAB SHOWN FOR NEW MEP WORK. COORDINATE <br />LOCATIONS ON FIXTURE AND MEP DRAWINGS. PATCH AND REPAIR FLOORING AS <br />NOTED. GC TO COORDINATE WITH LANDLORD'S ON -SITE REPRESENTATIVE PRIOR TO <br />CUTTING OR DRILLING EXISTING SLAB. <br />G. ALL FACEPLATES, PLUG AND SWITCHES SHOULD BE WHITE. THEY SHOULD NOT BE <br />PAINTED. <br />H. REUSING EXISTING SWITCHBANK IS OKAY AS LONG AS THE SWITCHES AND <br />FACEPLATES ARE WHITE (OR REPLACED TO BE WHITE). IF NOT EXISTING, THEN LOCATE <br />NEW SWITCHBANK ON STOCKROOM SIDE OF SALES/STOCK WALL. <br />J. F4A FOR THE WINDOW BANNERS TO BE ON THE EXTERIOR SIGNAGE CIRCUIT AND <br />TIED TO THE EXTERIOR SIGN TIMECLOCK. <br />K. WI-FI SYSTEM (EQUIPMENT PROVIDED BY AT&T) REQUIRES A POA (POWER OVER <br />ETHERNET) CONNECTION TO A SINGLE ACCESS POINT, WITH SUCH ACCESS POINT TO <br />BE LOCATED ON THE CEILING NEAR THE MIDDLE OF THE STORE. POA TO EXTEND TO <br />THE WI-FI EQUIPMENT LOCATION IN BOH. <br />L. CONTRACTOR TO PROVIDE LABELING FOR THE DUAL SWITCHED/NON-SWITCHED <br />ELECTRICAL OUTLETS BEHIND THE MWU'S. <br />M. UNDERCARPET WIRING IS NOT ACCEPTABLE. FLUSH MOUNTED ELECTRICAL FLOOR <br />BOXES MUST BE INSTALLED IN LOCATIONS NOTED PER PLAN. <br />N. ANY DEALER -PROVIDED SECURITY EQUIPMENT TO BE WHITE OR SILVER COLOR <br />ONLY, NOT BLACK. <br />P. ANY CODE REQUIRED ALARM OR EMERGENCY LIGHTING DEVICES SHALL BE <br />LOCATED ABOVE 8' AFF (WITHIN "WHITE" PAINT AREA), IF ALLOWED BY CODE. <br />FLOOR PLAN KEY NOTES 0 <br />O CENTERLINES ARE USED TO LAYOUT STORE, INCLUDING CEILING, POWER / DATA, <br />FIXTURES, ETC. AND MUST BE MARKED AND VARIFIED PRIOR TO START OF <br />CONSTRUCTION. CONTACT ARCHITECT IMMEDIATELY IF THERE ARE DIMENSIONAL <br />DISCREPANCIES. <br />O PROMOTIONAL POSTER RAILS PROVIDED BY FIXTURE VENDOR, PROMOTIONAL <br />POSTER PROVIDED BY OTHERS. <br />O BOH SHOWN FOR REFERENCE ONLY AND BY OTHERS, NIC. <br />O NOT USED. <br />5O CONVENIENCE ELECTRICAL OUTLETS SHOWN MAYBE RELOCATED OF ELIMINATED <br />AS PER DEALER DIRECTION. <br />6O FLOOR SAW CUTTING, CONCRETE REMOVAL, INSTALLATION OF DOWELS & WIRE <br />MESH REINFORCING, REPOURING 4" CONCRETE SLAB SHALL BE BY THE GC. <br />TRENCHING, INSTALLATION OF CONDUITS, BACKFILLING & COMPACTION OF <br />BACKFILL BY ELECTRICAL CONTRACTOR. 4" CONCRETE SLAB SHALL BY DOWELLED <br />INTO EXISTING SLAB WITH #5 DOWELS, 6" INTO EXISTING SLAB AND EXTEND T-0" <br />INTO NEW SLAB POUR. THE NEW SLAB WIRE MESH REINFORCEMENT TO V-0" <br />SECTION OR DOWEL STICKING OUT OF EXISTING SLAB. REFERENCE SHEET R1.1 <br />FOR FLOOR BOX / STUB -UP LOCATIONS. <br />O PROVIDE DUAL BRANCH CIRCUIT FOURPLEX RECEPTACLE; 2 OUTLETS SWITCHED <br />(CONTROL FIXTURE LIGHTING), 2 OUTLETS HOT - PROVIDE BLACK ADHESIVE LABEL <br />WITH 1/4" LETTERING INDICATING "SWITCHED FOR LTG" ADHERED TO THE HALF OF <br />THE FOURPLEX PROVIDING POWER TO SWITCHED LIGHTING. CONNECT TO MAIN <br />SWITCH BANK LOCATED AS PER RCP. <br />O FIXTURE LIGHTS BEHIND AATV WALL MONITORS TO BE NIGHT LIGHTS. <br />9O RECEIPT PRINTER, 18" AFF DEDICATED CIRCUIT (MULTIPLE PRINTERS CAN SHARE <br />THE SAME CIRCUIT). <br />10 NOT USED. <br />11 PROVIDE ONE OUTLET TO BE OFF -CENTERED ON DISPLAY ELEMENT (WINDOW <br />BANNER). MOUNT TO CEILING ABOVE DISPLAY ELEMENT OR TO ADJACENT WALL <br />ABOVE STOREFRONT WINDOWS AS NEEDED (SEE REFERENCE PLANS). ADD <br />ADDITIONAL OUTLETS AS REQUIRED PER CODE. <br />12 2 DATA PORT IN CEILING FOR SHOPPERTRAK, FURNISHED AND INSTALLED BY <br />OTHERS. CENTER OVER ENTRY DOOR. <br />13 DEDICATED 20 AMP CIRCUIT FOR THE ELECTRICAL BEHIND BACKWRAP. <br />14 1 DATA PORT IN CEILING FOR WIFI ACCESS POINT. DEALER TO HAVE AVAILABLE <br />DUPLEX ELECTRICAL OUTLET IN "BACK OF HOUSE" AREA FOR WIFI EQUIPMENT; <br />DEALER TO MARK LOCATION OF JACK ON CEILING TO HELP WIFI TECHNICIAN <br />LOCATE; DEALER TO PROVIDE LADDER FOR WIFI TECHNICIAN'S USE. <br />15 TELCO BACKBOARD SEE ELECTRICAL FOR DETAILS. LOCATION TO BE VERIFIED BY <br />DEALER. <br />16 ADDITIONAL ELECTRICAL OUTLET AND OR DATA / VOICE. <br />POWER / COMMUNICATIONS <br />REFERENCE LEGEND <br />MEP DRAWINGS SHALL GOVERN <br />DUPLEX OUTLET <br />DUPLEX OUTLET DEDICATED <br />QUAD OUTLET <br />Ca <br />COAXIAL CABLE OUTLET <br />DATA OUTLET <br />0 <br />VOICE OUTLET <br />v <br />VOICE / DATA OUTLET <br />FLOOR DATA OUTLET <br />❑� <br />FLOOR DUPLEX OUTLET <br />0 <br />FLOOR QUAD OUTLET <br />0-i <br />THERMOSTAT <br />www.brph.com Copyright © 2014 <br />Architects, Engineers <br />2727 Paces Ferry Road I Bldg 1 1 Suite 1800 <br />Atlanta I Georgia 1 30339 <br />770-933-9242 1 770-933-9246 f <br />Offices in Melbourne, Orlando, West Palm <br />Beach, Atlanta, Charleston, Seattle <br />These plans are protected by Federal Copyright <br />protection. Unauthorized use may result in an <br />infringement action. <br />ISSUE FOR PERMIT AND CONSTRUCTION <br />REVISION A <br />PEI <br />Z <br />O <br />V <br />W <br />Of <br />W <br />U) <br />OF F/_O <br />ARCH/ENGR OF RECORD <br />BRUCE A. LOTT <br />AR0012048 <br />DESIGNED BY <br />BDR <br />DRAWN BY <br />KCC/ BJG <br />CHECKED BY <br />BAL <br />PROJECT NUMBER <br />C06898.057.01 <br />DATE <br />08/13/14 <br />TITLE <br />POWER/ DATA/ <br />FLOOR BOX <br />PLAN <br />DRAWING NO. <br />A7. 1 <br />1 I 2 <br />3 I 4 <br />5 I 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.