Laserfiche WebLink
NOTES: 1. ALLOW SUFFICIENT SPACE BELOW DRAIN PAN FOR TRAP <br />2. PITCH DRAIN FOR PROPER RUNOFF. <br />3. MANUALLY PRIME FILL TRAP BEFORE START-UP TO FORM <br />INITIAL DRAIN SEAL. <br />4. SUPPORT LENGTHY DRAIN LINES TO PREVENT SAG AND <br />CONDENSATE OVERFLOW. <br />A/C UNIT CLEANOUT VENT LINE <br />CAP <br />-(TYP.) PERFORATED <br />CAP <br />PITCH <br />DRAIN PAN ~ <br />PITCH <br />--► v <br />DRAIN PIPE <br />TO MATCH DRAIN <br />OUTLET SIZE. <br />(a) <br />THIS DIMENSION IN INCHES MUST BE <br />EQUAL TO THE MAXIMUM FAN SUCTION <br />THIS STANDARD DETAIL MUST <br />(NEGATIVE) STATIC PRESSURE IN INCHES <br />BE REVIEWED AND SITE <br />WG (WITH DIRTY FILTERS, COILS, AND <br />ADAPTED BY CONTRACTOR <br />MAXIMUM AIR FLOW) + 1" W.G. <br />PRIOR TO USE FOR FINAL <br />EQUIPMENT. <br />(b) <br />THIS DIMENSION IN INCHES MUST BE <br />EQUAL TO MIN. 1/2 OF THE (a) ABOVE <br />(c) <br />EQUALS (a) + (b) + PIPE DIA. + <br />+ INSULATION <br />DRAW THRU UNIT CONDENSATE TRAP <br />PROVIDE TEST TEE <br />WITH SCREWED COUNTER- <br />COLUMN OR PARTITION <br />SUNK ABS PLASTIC PLUG: <br />AS SHOWN ON FLOOR PLAN <br />TAPERED -THREAD WITH <br />CLEANOUT FACE SHALL <br />TFE JOINT COMPOUND. <br />BE WITHIN 4" OF WALL <br />SURFACE. PROVIDE <br />WHERE CLEANOUT TEE <br />PIPE EXTENSION IF REQUIRED. <br />IS CONCEALED IN A <br />CHASE OR PARTITION, <br />PROVIDE A ROUND 18 <br />GAUGE STAINLESS STEEL <br />COVER WITH BEVELED <br />EDGES AND FLATHEAD <br />MACHINE SCREW. <br />CONCRETE <br />FLOOR <br />SLAB <br />NOTPs <br />PROVIDE WCO WHERE SHOWN ON PLAN, AND ON SANITARY WASTE BRANCHES <br />NOT SERVED WITH A FLOOR CLEANOUT: LOCATE ABOVE FIXTURE FLOOD RIM <br />WITHIN 4' OF FLOOR. CONSULT LOCAL CODES FOR OTHER WCO REQUIREMENTS. <br />WALL CLEANOUT DETAIL <br />PLUMBING LEGEND <br />CO <br />CLEAN OUT <br />FD <br />FLOOR DRAIN <br />CW <br />DOMESTIC COLD WATER <br />HW <br />DOMESTIC HOT WATER <br />HWR <br />DOMESTIC HOT WATER RECIRCULATING <br />HB <br />HOSE BIBB <br />VTR <br />VENT THRU ROOF <br />m <br />GATE VALVE <br />D31 <br />GLOBE VALVE <br />CHECK VALVE <br />QN <br />17Q <br />BALANCING VALVE <br />i <br />GAS COCK <br />C <br />WATER HAMMER ARRESTER (PDI No.) <br />FD <br />FLOOR DRAIN <br />O <br />RECIRCULATION PUMP <br />SANITARY SEWER PIPING <br />-----i VENT PIPING <br />------i DOMESTIC COLD WATER PIPING <br />------- HOT WATER PIPING (110') <br />- - - HOT WATER RECIRCULATING PIPING <br />S- CD -S CONDENSATE PIPING <br />S-- SD -S STORM DRAIN PIPING <br />S- G -; GAS PIPING <br />fr-O-s PIPE RISE UP <br />PIPE DOWN OR DROP <br />E-- CAPPED END OF PIPE <br />POINT OF CONNECTION <br />-LJ P-TRAP <br />GENERAL SPECIFICATIONS <br />1. ALL WORK SHALL BE PERFORMED BY A LICENSED CONTRACTOR IN A <br />FIRST CLASS WORKMAN LIKE MANNER. SAID CONTRACTOR SHALL MEET <br />ALL REQURRMENTS SET FORTH BY ANY LOCAL OROIANCE AND OR <br />GOVERNING AUTHORITIES <br />2. ALL WORKMANSHIP AND MATERIALS SHALL BE IN STRICT ACCORDENCE <br />WITH APPLICABLE NATIONAL, STATE, AND LOCAL CODES, AND <br />ORDINANCES. <br />3. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE <br />ALL LABOR, MATERIALS, AND SUPERVISION NECESSARY TO <br />ACCOMPLISH THE WORK SHOWN AND/OR NOTED ON THE DRAWINGS. <br />4. ALL REQUIRED INSURANCE SHALL BE PROVIDED FOR PROTECTION <br />AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE <br />DURATION OF THE WORK. <br />5. CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO BID AND VERIFY <br />ALL CONDITIONS, LOCATIONS, DIMENSIONS AND COUNTS AS SHOWN <br />AND/OR NOTED ON THE DRAWINGS. THIS SHALL INCLUDE ANY AND <br />ALL FABRICATIONS REQUIRED PRIOR TO INSTALLATION. <br />6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR FOR THE <br />ADVANCED ORDERING OF LONG LEAD ITEMS AS NOT TO INTERFER WITH <br />THE PRODUCTION OF OTHER TRADES RESULTING IN ANY DOWN OR LAG <br />TIME. <br />7. CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP <br />FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN (1) YEAR <br />FROM DATE OF ACCEPTANCE, UNLESS INDICATED OR SPECIFIED <br />ORTHIDiWISE. <br />& ORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT <br />ADDITIONAL CHARGE AND SHALL INCLUDE REPLACEMENT OR REPAIR <br />OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN <br />DAMAGED THEREBY. <br />9. THE CONTRACTOR SHALL BE RESPONABLE TO REPAIR TO ORIGINAL <br />CONDITION ANY AND ALL DAMAGES TO BUILDING SURFACES, <br />EQUIPMENT, AND FURNISHINGS CAUSED DURING PERFORMANCE OF <br />WORK. <br />10. LOCATION OF PLUMBING ROUGH -IN MAY CHANGE. VERIFY EXACT <br />LOCATION WITH ARCHITECT/ENGINEER PRIOR TO INSTALLATION. <br />DRAWINGS ARE DIAGRAMMATIC, DO NOT SCALE FOR THE EXACT <br />LOCATION OF FIXTURES, PIPING, EQUIPMENT, ETC. <br />11. ALL MATERIALS SHALL BE NEW AND SHALL BEAR UNDERWRITER'S <br />LABEL WHERE APPLICABLE. <br />12. THE COMPLETED SYSTEM SHALL BE FULLY OPERATIVE AND <br />ACCEPTANCE BY ARCHITECT/ENGINEER MUST BE A CONDITION OF THE <br />CONTRACT. <br />I& ALL EXCAVATION AND BACKFILL AS REQUIRED FOR THIS PHASE OF <br />CONSTRUCTION SHALL BE A PART OF THIS CONTRACT. <br />14. CONTRACTOR SHALL PAY FOR ALL PERMITS, FEES, INSPECTIONS, AND <br />TESTINGS. <br />15. ARCHITECTURAL AND/OR ENGINEERING EXPENSES THAT ARE INCURRED <br />DUE TO REVISIONS OR SUBSTITUTIONS REQUESTED BY THE <br />CONTRACTOR SHALL BE PAID FOR BY THAT CONTRACTOR. <br />16. THE CONTRACTOR SHALL FURNISH ALL WATER METERS UNLESS <br />OTHERWISE NOTED. <br />17. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID <br />INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION. <br />1& VERIFY LOCATION, SIZE, ELEVATION, MATERIALS, AND PRESENT STATE <br />OF ALL EXISTING UTILITIES. <br />19. INSTALL READILY ACCESSIBLE GATE VALVES IN ALL BRANCH WATER <br />LINES SERVING ANY ROOM HAVING PLUMBING FIXTURES ALL <br />FIXTURES SHALL BE PROVIDED WITH READILY ACCESSIBLE VALVES. <br />20. MAIN WATER SUPPLY SHALL BE EQUIPTED WITH A BACKFLOW <br />PREVENTER <br />21. ALL THREADED WATER OUTLETS (EXCEPT FOR AUTOMATIC CLOTHES <br />WASHERS) SHALL BE FURNISHED WITH WATTS #BA APPROVED VACUUM <br />BREAKERS. <br />22 FURNISH AND INSTALL APPROVED WATER HAMMER ARRESTORS ON <br />QUICK CLOSING VALVES, NEAR THE FIXTURES IN AN EFFECTIVE RANGE. <br />23. WHERE DISSIMILAR METALS ARE TO BE JOINED, APPROVED INSULATING <br />UNIONS SHALL BE USED. <br />24. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT <br />ADDITIONAL CHARGE AND SHALL INCLUDE REPLACEMENT OR REPAIR <br />OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN <br />DAMAGED THEREBY. <br />25. IF THE CONTRACTOR PROPOSES TO USE ANY ARTICLE. DEVICE, <br />PRODUCT, OR MATERIALS WHICH IS NOT AS SPECIFIED, THE <br />CONTRACTOR SHALL BE RESPONSIBILITY TO PROVE TO THE <br />ARCHITECT/ENGINEER THAT THE PROPOSED SUBSTITUTION IS EQUAL. <br />26. THE CONTRACTOR SHALL KEEP ALL AREAS IN WHICH WORK IS BEING <br />PERPFORMED, FREE FROM DEBRIS AT ALL TIMES AND SAID AREAS <br />SHALL BE LEFT BROOM CLEAN AT THE END OF EACH WORKING DAY. <br />27. THE CONTRACTOR SHALL FURNISH A COMPLETE SET OF AS -BUILT <br />DRAWINGS, SHOWING ALL CHANGES AND DEVIATIONS, TO THE <br />ARCHITECT/I:NGINEER PROIR TO COMPLETION OF THE PROJECT. <br />HANGER NO. 24 EXISTING LATERAL DRAIN TIE IN LOCATION <br />BOTTOM BEAM C-CLAMP MODEL 300 CUT SLAB AS NEEDED FOR DRAINAGE <br />MICHIGAN SEE NOTE COVER PAGE FOR CONCRETE/REIN. <br />STEEL I -BEAM BOTTOM BEAM <br />OR BAR JOIST C-CLAMP OR <br />0 <br />HANGER ROD SHALL BE EQUAL WITH d <br />TIGHTENED HARD AGAINST LOCK NUT <br />THE STRUCTURAL STEEL <br />MEMBER <br />-�- ALL THREAD ROD z <br />"A" VARIES TANNING STOR. J EXIST. 1 <br />7-COPPER" <br />; <br />112 109 a C.W. LINE <br />SIMNEL RING 10'-0" AT CEILING WATER HEATER <br />HANGER F7 81 g I 31 3: <br />C4 I W1 C2 W2 _� o' r - -, -� __ d_: <br />+• PIPE <br />• L---- I -W. ---- �` <br />PIPE HANGER ! SUPPORT -/EX1 Fco \'\ <br />N.T.S. ,/ I `� <br />UI i <br />CONCRETE SLAB _i :5_ H.W. <br />----- -------- <br />DROP -IN /» <br />MIN. 5/8" ANCHOR LOOP VENT TYP _5" C. T- <br />HILTI HDI z I Q- <br />OR EQUAL j �, ; I PROP. MOP <br />c � <br />HANGER ROD _ <br />1. NOTE:ROVIDE WATER HEATER REUEF PVC DRAIN TO MOP-- <br />/ SINK FOR EMERGENCY OVERFLOW WOM EI'�-; �I N RAIN <br />"A" VARIES 2. PROVIDE NEW HVAC UNITS CONDENSATE DRAIN TO ' <br />MOP SINK 10 ; 3ii PROP. WC <br />3. PROVIDE SHUT OFF VALVUES AT ALL PLUM. FIXTURE <br />22.2 94 :-L___5__C.W_----------- <br />DROPS C2 W2 3i I -♦ <br />4. VERIFY BACKFLOW PREVENTOR FOR MAIN WATER =, <br />z i <br />�; Cr <br />, <br />CLEVIS HANGER <br />1/80-1/4 CARBON <br />STEEL COPPER PLATED_5 C. W '- <br />GRINNELL FIG # CT-65 Z - ----------------------------------------------------------• <br />W' N <br />OR EQUAL 1 <br />, <br />5" H.W. <br />----------------------------------------- --J ' --------------------------------------------------- � ---•_ 5" H.W. <br />PIPE HANGER / SUPPORT PROP. LAV 3; 5" C.W. <br />/ UNISEX Z <br />--" C.W. ----- ----- <br />d ' <br />N.T.S. o in' a 31 <br />I 110 �`� a cal PROP. LAV <br />GALVANIZED 10'-0" <br />SURFACE MOUNTED 22,2 B4 <br />CHANNEL ANCHORED , C4 W2 ; pR IN <br />THROUGH THE BACK <br />N o: <br />OF THE CHANNEL----------- 5 C.W.--------------- ------------------ ------ ---- -- -r-- 5i <br />0 <br />» DRAIN <br />_.5_ H.W. <br />o PROP. WC <br />a <br />~ .5" _ W. <br />18 GA. SHEET METAL ; z <br />PIPE CLAMP SADDLE FOR INSULATED � <br />PIPES; 1 /4" THICK i a _ <br />NEOPRENE SLEEVE FOR <br />UN -INSULATED PIPES. z <br />----- <br />3i � <br />NOTES: <br />1. APPLICABLE FOR CONTROL TUBING <br />U <br />2. APPLICABLE FOR PIPING NO LARGER THAN 1-1/2" ; I <br />3. APPLICABLE FOR HORIZONTAL TRAPEZE ' <br />OR FOR VERTICAL PIPING ; ,- <br />PIPE /TUBE SUPPORT RAIN <br />N.T.S. __5"_ C.W:----- ----- <br />Iu <br />WATER HAMMER ARRESTOR -PIPING SCHEDULE MENo PROP. LAV <br />SELECTION BASE ON ZURN MANUFACTURING SHOKSTOP DATA y- <br />MFG.CAT. TYPE N0. 100 200 300 400 NOTE: ** TRAINER 2Z20 C.W. <br />P. D. I. SYSTEM A B C D 111 C2 W2 <br />FIXTURE UNIT RATING 1 - 11 12 - 32 33 - 60 60 -113 REMARKS: 10-0" RAIN <br />F1 81 I PROP. WC <br />FCO <br />SYMBOL Z-1700 88 F.U. 256 F.U. 3 <br />490 F.U. 904 F.U. NOTE: ** C4 WN <br />' <br />CU I o <br />NOTE: ** CONTRACTOR SHALL PROVIDE AND INSTALL WATER HAMMER ARRESTORS IN DOMESTIC PIPING SYSTEM ;�; �♦, <br />AS PER FBC 604.9 AND PER MANUFACTURERS RECOMMENDATION. <br />FIXTURE SCHEDULE <br />EQUIPMENT <br />SELECTION BASED ON : <br />SYSTEM CONNECTIONS <br />SYMBOL <br />ITEM DESCRIPTION <br />CW <br />HW <br />TRAP <br />DRAIN <br />FIXTURE <br />UNITS <br />MFGR <br />MODEL <br />P.1 <br />WATER CLOSET (1.6 GAL FL) <br />3/4" <br />--- <br />INTEGRAL <br />3" <br />4 <br />PROFLO <br />WHITE - PF2203 - ADA (TANK PF3212) (SEAT PFTSCOF2000WIH) <br />P.2 <br />LAVATORY (ADA) <br />1/2" <br />1/2" <br />1-1/2" <br />2" <br />1 <br />PROFLO <br />PF5504YM - ADA COMPLIANT (FAUCET MOEN - 8800 ADA COMPLIANT ) <br />P.3 <br />DRINKING FOUNTAIN <br />1/2" <br />--- <br />1-1/4- <br />.5 <br />ELKAY <br />EZSTL8LC - ADA COMPLIANT <br />P.4 <br />SHOWER VALVE <br />1/2" <br />1/2" <br />2 <br />MOEN <br />62300 - ADA COMPLIANT <br />P.5 <br />SHOWER VALVE TRIM <br />MOEN <br />TL182 - ADA COMPLIANT <br />IPFZ199625 <br />P.6 <br />MOP SINK (SERVICE) <br />1/2" <br />1/2" <br />1 1-1/2" <br />2" <br />2 <br />PROFLO <br />(FAUCET MOEN 8230 ADA COMP.) <br />NOTE <br />PLUMBING FIXTURES SHOWN OR EQUAL SHALL BE PROVIDED BY CONTRACTOR WITH SHOP DRAWINGS <br />ON EACH FIXTURE SUBMITTED FOR APPROVAL BY THE OWNER & DESIGNER. <br />FIXTURE COLOR IS WHITE <br />IMPORTANT - ALL FIXTURES SHALL MEET BE ADA COMPLIANT AND MOUNTED AT HEIGHTS ACCORDING TO <br />CHAPTER 11 OF THE FLORIDA BUILDING CODE <br />NOTE: <br />1. PROVIDE ACCESS PANELS FOR EACH GANG OF VALVES <br />2. PROVIDE AND INSTALL TRAP AND SUPPLY LINE INSULATION KIT. <br />3. ALL PLUMBING FIXTURES & FIXTURE FITTINGS SHALL COMPLY WITH FBC PLUMBING TABLE SEC.604.4 & SEC.604. <br />4. BARRIER FREE WALL MOUNTED HIAOW (ADA) COMPLIANT HEIGHT TO COMPLY WITH ALL CODES FOR (ADA). <br />NOTE: '* SIZE AS INDICATED ON DRAWINGS. <br />1) ALL FLOOR DRAINS SHALL BE RESEALED BY MEANS OF A ZURN TRAP PRIMER VALVE INSTALLED IN COLD WATER SUPPLY <br />UNE FROM THE NEAREST SINK OR LAVATORY AND WITH 1/2 INCH DRAIN SLOPED TO THE FLOOR DRAIN. OR BY APPROVED <br />ALTERNATE METHOD EQUAL TO THE ABOVE. <br />2) COORDINATE WITH ARCHITECTURAL DRAWING FOR FLOOR OR AREA FINISH; AND PROVIDE CORRECT TOP STYLE FOR aRM► IC OR <br />QUARRY TILE. ASPHALT OR VINYL TILE, TERRAllO. POURED OR TRAWLED SYNTHETIC. FINISH CONCRETE. AND ALL PAVED AREAS, <br />PROVIDE FOR FLOORS HAVING A WATERPROOF MEMBRANE, USE ZURN FLANGE CLAMPING RING. <br />MATERIAL SPECIFICATIONS <br />DOMESTIC WATER PIPING SHALL BE HARD COPPER PIPE TYPE "L" <br />ANSI / ASTM B-88 WITH WROUGHT -COPPER SOLDER -JOINTS <br />FITTINGS ASTM B-16.22. BELOW GRADE PIPING SHALL BE TYPE "K" <br />ANSI / ASTM SOFT COPPER WITH NO JOINTS OR FITTINGS BELOW <br />GRADE. <br />2. PIPING: SOIL, WASTE AND VENT PIPING SHALL BE PVC <br />3. PIPING: RAIN WATER PIPING SHALL BE POLYVINYL CHLORIDE <br />SCHEDULE 40 (PVC) PLASTIC DRAIN. WASTE PIPE AND FITTINGS. PIPE <br />AND FITTINGS SHALL CONFORMING TO ANSI STANDARD K65.56-1971 <br />AND ASTM STANDARD D2665-82. SOLVENT CEMENT FOR POLYVINYL <br />CHLORIDE (PVC) PLASTIC PIPE AND FITTINGS SHALL CONFORM TO ANSI <br />STANDARD B72.16-1971 AND ASTM STANDARD D2564-80. <br />4. INSULATE ALL HOT WATER, LINES, AS FOLLOWS: HW SUPPLY 1" THICK <br />PREFORMED ARMAFLEX PIPE INSULATION. HORIZONTAL STORM DRAIN <br />PIPING WITH 1-1/2" THICK PERFORMED FIBERGLASS PIPE INSULATION. <br />GENERAL NOTES: <br />1- DO NOT SCALE DRAWINGS FOR PARTITION LOCATION. CONSULT <br />ARCHITECTURAL & STRUCTURAL DRAWINGS FOR DIMENSIONS. <br />2- CONTRACTOR SHALL VISIT SITE TO VERIFY FIELD CONDITIONS <br />& PHYSICAL LOCATIONS & SIZE OF EXISTING SERVICES. <br />3- SANITARY LINES LARGER THAN 2J" TO SLOPE J"/FOOT. <br />4- SANITARY LINES 2j" AND LESS TO SLOPE }"/FOOT. <br />5- CONSULT ARCHITECTURAL DRAWINGS FOR ALL FINISH FLOOR <br />& GRADE ELEVATIONS. <br />6- SEE ARCHITECTURAL DWG'S FOR ROOF DRAINAGE. <br />HANGER SCHEDULE - ROD SIZE <br />PIPE ROD NOTE: <br />SIZE DIA. <br />CONTRACTOR TO COMPLY WITH FBC <br />1 2 3/8 SEC 308 & HANGER SPACING TABLE <br />3/4" 3/8" 308.5 <br />1-1/4" <br />3/8- <br />1- 1 /2" <br />3/8" <br />2" <br />3/8" <br />2-1/2 <br />1/2- <br />3" <br />1/2" <br />3-1/2" <br />1/2" <br />4" <br />5/8" <br />5" <br />5/8" <br />3 4 <br />7 8' <br />DRINKING FOUNTAIN <br />PROPOSED PLUMBING PLAN <br />SCALE: NTS <br />SLOPE OF HORIZ. <br />DRAINAGE PIPE <br />SIZE (inches) <br />MINIMUM SLOPE (inch per foot) <br />2-1/2 or less <br />1/4 <br />3 to 6 <br />1/8 <br />8 or larger <br />1 /16 <br />TABLE 704.1 OF THE FLORIDA PLUMBING CODE 2004 <br />TANKLESS HOT ELECTRIC WATER HEATER SCHEDULE <br />MODEL <br />MANUFACTURE <br />WIRING <br />VOLTS <br />AMPS <br />KW <br />SET MPAX <br />TEM <br />I ACCESSORIES/REMARKS: <br />RP-1 <br />FORTIS - 9.0 GPM <br />8 GA <br />208 <br />18 <br />3.5 <br />110' IF <br />WITH 0.5 GPM FAUCET AERATOR FOR SINKS & LAVATOR S. <br />MOUNT HEATER ON WALL IN MECH <br />ENGINEER OF RECORD: <br />COOL AND COBB <br />ENGINEERING CO. <br />CERT OF AUTHIZATION #29713 <br />FL LICENS #16921 <br />203 WEST MAIN ST. <br />AVON PARK, FL 33825 <br />PH. 863.657.2323 <br />DRAFTING SERVICES BY: <br />MICHAEL GARRISON <br />224 DATURA ST. #401 <br />WEST PALM BEACH, FL 33401 <br />561.835.9744 <br />'NT: <br />ORANGEWOOD <br />BUILDERS <br />ESS: <br />1105 WEST CIRCLE ST <br />AVON PARK, FL 33825 <br />863.452.6400 <br />N <br />0 <br />J <br />Q <br />Uf <br />O w <br />w <br />co m <br />CL <br />2 Unix � <br />¢ W� <br />N v <br />Cr <br />W <br />104 <br />W <br />W <br />G <br />REVISIONS/SUBMITTALS: <br />ID DESC DATE <br />PERMIT SUBMITTAL 12.19.11 <br />I AS BUILTS 6.11.121 <br />AWN BY: MSG <br />ECKED BY: COOL&COB <br />OJECT: <br />TE: 5.11.12 <br />P 1 <br />�Z OF 13 1 <br />