Laserfiche WebLink
LOCKING QUADRANT <br />TO BE EXPOSED — <br />FLEXIBLE DUCT WITH <br />INSULATION do <br />VAPOR BARRIER <br />TIE TO <br />STRUCTURAL <br />SUPPORTS <br />2" WIDE METAL BAND <br />SUPPORT <br />SQUARE TO <br />ROUND <br />ADAPTER - <br />-SUSPENDED TYPE <br />CEILING SYSTEM <br />I D IFFI <br />M-) SCALE <br />e� <br />GALV. STEEL ROD OR <br />STRAP SUPPORTS PER <br />SMACNA STANDARDS <br />SIDE TAKE —OFF FITTING <br />WITH DAMPER, BELL MOUTH <br />OR SHOETAP TYPE <br />MAIN <br />SUPPLY AIR <br />DUCT, <br />SEE PLANS FOR <br />TYPE AND INSULATION <br />1-1/2" X 1-1/2" X 1/8" GALV. <br />ANGLE OR STRAP PER SMACNA <br />CONNECT INNER DUCT WITH DRAWBAND AND SEAL <br />WITH TAPE/MASTIC OUTERDUCT AT NECK CONNECTION <br />LOUVERED FACE CEILING DIFFUSER <br />WITH 2' X 2' LAY —IN ALUM. PANEL <br />MOUNTING DETAI <br />: NTS <br />74-20 ALL —THREAD <br />(TYPICAL OF 4) <br />FACTORY SUPPLIED RUBBER IN <br />SHEAR TYPE MOUNTING KIT <br />FACTORY SUPPLIED MOUNTING <br />BRACKET <br />HANGER ANGLES <br />STRAPS <br />STRAP HANGERS 1" <br />HANGERS STRAP <br />3/8" BOLT <br />HANGERS RODS <br />BAND OF SAME SIZI <br />AS HANGER STRAP <br />T <br />E <br />HANGERS <br />RODS OR <br />STRAPS <br />JAND <br />L �J <br />HEX NUTS <br />HANGERS FOR HOT & COLD DUCTS <br />Nam: <br />1. ALL WORK TO BE DONE IN ACCORDANCE WITH THESE PLANS AND THE 2006 REVISIONS OF THE 2004 FLORIDA BUILDING CODE. <br />2. THESE DRAWINGS ARE SCHEMATIC IN NATURE AND ARE NOT INTENDED TO SHOW EVERY MINOR DETAIL THE CONTRACTOR SHALL FURNISH AND INSTALL ALL ITEMS REQUIRED FOR A COMPLETE ACCEPTABLE WORKING INSTALLATION, AND COORDINATE THIS <br />INSTALLATION WITH ALL TRADES. <br />3. ALL WORK SHALL BE PERFORMED BY A LICENSED CONTRACTOR CERTIFIED IN THE STATE OF FLORIDA. <br />4. THE CONTRACTOR SHALL VISIT THE JOB SITE, MEET WITH ALL RELATED TRADES, AND FAMILIARIZE HIS/HER SELF WITH ANY AND ALL CONDITONS RELATING TO HIS/HER WORK. <br />5. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE THAT MAY DELAY CONSTRUCTION. <br />6. CONDENSATE DISPOSAL SHALL BE PROVIDED FOR EQUIPMENT AND APPLIANCES CONTAINING EVAPORATOR COILS. CONDENSATE DRAIN SYSTEM SHALL BE DESIGNED, CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH SECTIONS 307.2.1 THROUGH 307.2.4. OF <br />THE 2004 FLORIDA BUILDING CODE. CONDENSATE DRAIN SHALL TERMINATE TO APPROVED LOCATION. 7. ALL HORIZONTAL PRIMARY CONDENSATE DRAIN WITHIN UNCONDITIONED AREAS SHALL BE INSULATED TO PREVENT CONDENSATION FROM FORMING ON THE <br />EXTERIOR OF THE DRAIN LINE. <br />8. PACKAGED UNITS SHALL BE LOCATED ON ROOF WITH FACTORY ROOF CURB. ROOF CURB SHALL BE ATTACHED PER MANUFACTURER SPECIFICATIONS AND THE 2004 FBC. <br />9. DUCT CONSTRUCTION AND INSTALLATION SHALL COMPLY WITH SECTION M603 OF THE FLORIDA BUILDING CODE MECHANICAL <br />10. AIR CONDITIONING DUCT SYSTEM DESIGN BASED ON 1.5" TYPE "M" KNAUF DUCT AND R-6 INSULATED CLASS 1 SILVER FLEX DUCT. ALL DUCT WORK SHALL BE SEALED WITH SILVER TAPE AND MASTIC DUCT SEALANT. <br />11. KEEP ALL FRESH AIR INTAKES A MINIMUM OF 10' FROM EXHAUST FAN TERMINATION POINTS AND SANITARY SEWER VENT OUTLETS.PACKAGED UNIT SHALL INCORPORATE A MANUAL ADJUSTABLE FRESH AIR DAMPER ON ROOF TOP UNITS. <br />12. VENT BATH FANS TO AN OUTSIDE VENT USING DUCT SIZE AS INDICATED.ALL EXHUAST FANS SHALL INCORPORATE A BACKDRAFT DAMPER. <br />13. INSTALL SMOKE DECTECTORS (SD) AS PER SECTION M606 OF THE FLORIDA BUILDING CODE MECHANICAL <br />14. FIRE DAMPERS SHALL BE INSTALLED IN ACCORDANCE WITH CHAPTER 716 OF THE 2004 FLORIDA BUILDING CODE. <br />15. DUCTS AND TRANSFER OPENINGS THAT PENETRATGE FIRE -RESISTANCE -RATED ASSEMBLIES AND ARE NOT REQUIRED BY THIS SECTION TO HAVE DAMPERS SHALL COMPLY WITH THE REQUIREMENTS OF SECTION 712 OF THE 2004 FLORIDA BUILDING CODE. <br />16. COORDINATE DIFFUSER do THERMOSTAT LOCATIONS WITH OWNER, CONTRACTOR, do OTHER TRADES. <br />17. ALL DUCTS AND PLENUMS SHALL BE MADE AIR TIGHT, CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH THE CURRENT ADDITION CHAPTER 13 OF THE FLORIDA BUILDING CODE. DUCT LEAKAGE RATE SHALL NOT EXCEED 5X OF THE RATED AIR HANDLER <br />FLOW, <br />18. ALTERNATE BRANDS OF EQUIPMENT MAY BE USED AS A SUBSTITUTION. THE ALTERNATE BRAND SHALL HAVE THE SAME, SENSIBLE HEAT RATIO AND SHALL NOT EXCEED THE TOTAL BTUH OUTPUT BY 10X <br />RELOC. 824* <br />90 CFM — 10" 00 <br />BD X 24" PROP <br />Rd OC. <br />BALANCING DAMPER COLLARZ V�2x 24-VP1INSTALL AT ALL SUPPLY RUN —OUTS <br />TYPICAL DUCT CONNECTION <br />Take —off Collar for duct board <br />with thl rma9alt asket flap and manual dam <br />sea w tpfl me a die and m ic. <br />Split Ring Seal Stra —minimum 5' Into Is <br />for flexible duct <br />DUCT,�OARD" ss 1 Flexible air duc <br />knauf ecilppse <br />anit—micorbiai <br />equal Metal tope, panduit strap <br />an mastic flexible connection <br />to tab collar. <br />AIR DISTRIBUTION -TYPICAL <br />TYPE <br />LD 24x24A-__I <br />200 <br />`SIZE <br />CFM <br />TYPE: <br />LD = T—BAR LAY IN CEILING DIFFUSER <br />1 W = 1 WAY CEILING DIFFUSER <br />2W = 2 WAY CEILING DIFFUSER <br />3W = 3 WAY CEILING DIFFUSER <br />4W = 4 WAY CEILING DIFFUSER <br />SW = SIDEWALL METAL DUCT DIFFUSER <br />FD = FLOOR DIFFUSER <br />LSD = LINEAR SLOT DIFFUSER —SUPPLY <br />LSR = LINEAR SLOT DIFFUSER —RETURN <br />LBG = LINEAR BAR GRILL <br />RA = RETURN AIR GRILL <br />EV = EXHAUST VENT —USE RETURN AIR GRILL <br />DSV = DEHUMIDIFIER SUPPLY DIFFUSER —USE <br />SUPPLY DIFFUSER <br />DRV = DEHUMIDIFIER RETURN DIFFUSER —USE <br />RETURN DIFFUSER <br />*LAY —IN DIFFUSERS BASED ON METAL—AIRE <br />ALUMINUM 4 WAY THROW WITH OPPOSED BLADE <br />DAMPER <br />BATHROOM/KITCHEN EXHAUST FANS <br />MARK BRAND MOD # CFM SP VOLT AMPS MOUNT QUANITY <br />EF-1 PANASONIC FV05VQ3 50 .25 120 0.13 CEILING 3 <br />*EF-1 WIRE TO LIGHT SWITCH <br />MECHANICAL PLAN <br />SCALE: 1 /4" = 1'-0" <br />ENGINEER OF RECORD: <br />COOL AND COBB <br />ENGINEERING CO. <br />CERT OF AUTHIZATION #29713 <br />FL LICEN'Sk fl16921 <br />203 VVEST M1A;J ST. <br />AVON PARK, FL 33825 <br />PH. 863.657.2323 <br />DRAFTING SERVICES BY: <br />MICHAEL GARRISON <br />224 DATURA ST. #401 <br />WEST PALM BEACH, FL 33401 <br />561.835.9 744 <br />�r <br />o ORANGEWOOD <br />BUILDERS <br />' w 0 <br />® wADDRESS: <br />AVON PARK, FL 33825 <br />w e► ' <br />IC34 <br />•,% ,II <br />to <br />� n <br />• �. <br />- EXIST. UNIT I <br />• . , w . , I <br />• <br />TO EXIST. UNIT 3 cl: <br />r�l / <br />aq <br />I1>r <br />�■ ' <br />.r. fir. M.C. -a ., -L., . EXISTING UNIT #2 ch <br />DUCTS TO BE RELOCATED <br />NO NEW ADDITIONS <br />3 , T <br />••.- <br />ID DES C DATE <br />PERMIT : Ifs <br />w ,i • <br />�4 <br />PROJECTDRAWN BY- MSG <br />CHECKED BY: COOL&COB8' <br />t► <br />RE =. R&M <br />r. <br />0 — 0 — E_ - r <br />. .,. r - - :n � if�C■T'i�� """Y 4 .�. � � � rf�l'' - --� - - _ ' <br />