My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
8349 Wheatstone Dr
Zephyrhills
>
Building Department
>
Building Plans
>
8349 Wheatstone Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 10:51:26 AM
Creation date
2/19/2025 8:35:48 AM
Metadata
Fields
Template:
Building Plans
Street #
8349
Location
Wheatstone Dr
Contractor
DR Horton
Building Plans - Permit #
2906
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: 5C51 EOE5-24F8-4973-AEC4-091 C2884D59C <br />EXISTING EXTERIOR CMU <br />MIN. 3" EDGE DISTANCE �I <br />STRIP OF WWF FROM F.F.E. TO -- <br />MIN. 6" BELOW GRADE. WWF TO <br />EXISTING FOUNDATION FACE w/ <br />(2) ROWS OF 3/16' DIA. TAPCONS <br />OR CUT NAILS @ 24" O.C. COVER <br />FLUSH w/ 3000psi CONCRETE. <br />D ° <br />j D <br />D EXISTING FOUNDATION. <br />p D <br />D \ <br />° <br />� D <br />8" CMU WALL OVERHANGS LESS THAN 1" <br />GROUT BOTTOM 3 COURSES -- <br />OF EXISTING CMU WALL FOR <br />LENGTH OF OVERHANG. FILL <br />TO BOTTOM OF WINDOW SILL <br />WHERE NEEDED <br />MIN. 3" EDGE DISTANCE <br />STRIP OF WWF FROM F.F.E. TO <br />BOTTOM OF FTG. WWF TO <br />EXISTING FOUNDATION FACE w/ <br />(2) ROWS OF 3/16' DIA. TAPCONS <br />OR CUT NAILS @ 24" O.C. COVER <br />FLUSH w/ 3000psi CONCRETE. <br />/ / p <br />D D EXISTING FOUNDATION <br />� p a <br />a � D <br />— D <br />8" CMU WALL OVERHANGS 2.5" OR LESS <br />NOTES: <br />• IF EXISTING REBAR DOES NOT MEET 3" EDGE DISTANCE REQUIREMENT, <br />REMOVE INSIDE FACE SHELL OF EXISTING CMU WALL AT ADJECENT CELL <br />AND DRILL & EPDXY NEW FULL HT. VERTICAL #5 DOWEL W/ 12" EMBED INTO <br />EXISTING FOUNDATION AND 4" EMBED INTO EXISTING BOND BEAM. <br />• IF MORE THAN (3) BARS DO NOT MEET THE REQUIRED 3" EDGE DISTANCE, <br />CONTACT EOR. <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1 4 WWF OR <br />FIBERMESH <br />0' _0" A.F.F SEE ARCH <br />(MAX 20" <br />G t ° <br />DEEP) <br />4 <br />14" <br />4" EXTENSION <br />II I UNDER BRICK VENEER <br />12" UNDER 1 STORY WALL VAPOR BARRIER <br />16" UNDER 2 STORY WALL <br />6 BEARING CURB STEP SECTION <br />CONCRETE SLAB w/ 6x6 <br />W1.4 x W1 4 WWF OR <br />FIBERMESH <br />a- — -- 9_ - - -- ---- — - <br />a <br />a ° <br />\ \\ Q a <br />VAPOR BARRIER <br />3 BEARING WALL FOOTING SECTION <br />12" <br />I <br />CONTINUOUSCONCRETECONCRETE <br />FOOTING, SEE PLAN <br />LAP #5 CONTINUOUS BAR AS <br />NEEDED, MIN 12" LAP AS SHOWN <br />NO.5 BAR BEND 90 DEGREE <br />TYPICAL STEP IN FOOTING DETAIL <br />CMU STEMWALL MONO LITHIC SLAB <br />14 <br />8" CMU CHAIR BLOCK W/ (1) #5 <br />CONTINUOUS TO EXTEND MIN 24" <br />INTO MONOLITHIC THICKENED EDGE <br />MIN 24" LAP <br />-- _ Qa A- 8• — — <br />W Z A , <br />o aQ ° `° <br />° <br />oZ <br />U A <br />• ° <br />°° e o A ° A ° <br />MIN12" //\//\//\//\//\//\// <br />• ° °/\\��\/\\/ <br />LOCATE VERTICAL <br />REINFORCEMENT IN LAST <br />STEMWALL CELL <br />4" CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />#4 OR #5 <br />REINFORCING PER <br />MONOLITHIC FOOTING <br />�-----,SECTION <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL <br />• STEMWALL FOOTING TO EXTEND MIN <br />12" BELOW MONOLITHIC FOOTING <br />• ADDITIONAL #4 OR #5 VERTICAL TO BE <br />LOCATED WITHIN TRANSITION ZONE <br />AND TIE INTO STEMWALL FOOTING <br />REINFORCEMENT <br />CMU STEMWALL TO MONOLITHIC TRANSITION DETAIL <br />CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />- 8" CMU CHAIR <br />TOP OF SLAB BLOCK W/ (1) #4 OR #5 CONT. <br />- --71 cn <br />LU <br />\\ \\\�\\ i /\\% - ita o <br />/ <br />VAPOR BARRIER r�� LU <br />C) <br />i <br />#4 OR #5 VERT REINFORCING <br />72" O.C. <br />UP TO 3 COURSES: <br />4 TO 5 COURSES: 48" O.C. <br />.p <br />ADDITIONAL 94 OR <br />FOOTING TO BEAR ON FIRM #5 IN BRICK LEDGE <br />UNDISTURBED SOIL <br />VERTICAL REINFORCEMENT -- 4" OPT BRICK LEDGE <br />TO HAVE 6" BEND AT BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />C2STEMWALL SECTION <br />/ 1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />0'-0" A.F.F. _ <br />(BEYOND) sn <br />FLOATING CONCRETE w <br />SLAB W/ 6x6 W1.4xW1.4 <br />WWF OR FIBERMESH > <br />D <br />- <br />U-BLOCK W/ <br />U <br />AJ <br />w <br />(1)#4OR#5 <br />CONT <br />w <br />o <br />4-41 <br />FINISH <br />O <br />GRADE <br />#4 OR#5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C. \ \\\\\ <br />4 TO 5 COURSES: 48" O.C. <br />� � I <br />FOOTING TO BEAR ON FIRM — - - ADDITIONAL #4 OR <br />UNDISTURBED SOIL <br />#5 IN BRICK LEDGE <br />VERT REINFORCEMENT TO - 4" OPT BRICK LEDGE <br />HAVE 6" BEND @ BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />STEMWALL CURB SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />-- FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />(1) #4 OR #5 CONT. <br />MINIMUM 24" <br />36" MAX <br />VARIES PER <br />—o <br />ARCH PLANS <br />a d e <br />\/ <br />12" MIN <br />j\ <br />v e ° i <br />6" OPT. EXTENSION <br />b <br />IN BRICK LOCATIONS <br />- <br />ON FND PLAN <br />3'/z' CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR FIBERMESH <br />(1) #4 OR #5 90° BEND @ 48" O.C. <br />- <br />--- <br />VAPOR BARRIER <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL <br />1z UNDER 1 STORY WALL W/ (2) <br />ADDITIONAL NO. 4 OR NO. 5 #4 OR (2) #5 CONT <br />BAR IN BRICK LEDGE - <br />16" UNDER 2 STORY WALL W/ (3) <br />#4 OR (2) #5 CONT <br />1 MONOLOTHIC FOOTING SECTION - 36" MAX DEPTH <br />'NOTE": IT IS ACCEPTABLE TO SUBSTITUTE THIS., <br />HIS .,1A" FTG DETAIL FOR THE "1" <br />FTG DETAIL SPECIFIED ON THE FDN PLAN @ ANY LOCATIONS THAT THE FTG <br />DEPTH EXCEEDS 28". <br />IF GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY FROM STRUCTURE <br />STEEPER THAN V-0" VERTICALLY PER T-O" HORIZONTALLY, CONTRACTOR HAS <br />TWO CHOICES: <br />1. PRIOR TO CONSTRUCTION, SEEK GUIDANCE OF FOR TO PREVENT EROSION <br />OF SOIL. <br />2. USE STEMWALL FOOTING <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />VAPOR BARRIER <br />SEE NOTES (MAX 16") v <br />6 <br />STUCCO OR DIRECTLY ADHERED co <br />STONE CLADDING FINISH - MIN 6" rn <br />—;- — E <br />ALL OTHER EXTERIOR WALL N UV <br />r, D CLADDING - MIN 8", U.N.O. ON ARCH <br />N O <br />APES ° <br />/ o \ 12" MIN �\ \\ \\ \\ \\ \\ C <br />04 <br />00 <br />FOOTING TO BEAR ON / 6" OPT. EXTENSION IN BRICK <br />ca <br />FIRM UNDISTURBED LOCATIONS ON FND PLAN <br />SOIL <br />12" UNDER 1 STORY WALL w/ N <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 <br />BAR IN BRICK LEDGE J d <br />16" UNDER 2 STORY WALL w/ ILL. <br />(2) #5 OR (3) .4 CONTINUOUS wJ <br />ts -16 <br />1 MONOLITHIC FOOTING SECTION j true designs studios <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE Z <br />FOLLOWING OCCUR: O <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" ' <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY U 9000 REGENCY SQUARE BLVD. <br />FROM STRUCTURE STEEPER THAN V-0" VERTICALLY Q SUITE 100, JACKSONVILLE, FL 32211 <br />PER T-O" HORIZONTALLWO PREVENT EROSION OF SOIL. O <br />CD <br />CONCRETE SLAB w/ 6x6 O <br />(2) #4 OR (2) #5 CONTINUOUS W1.4 x W1.4 WWF OR <br />FIBERMESH Wcr <br />--° - —� --l- 4 <br />4 041HOMON' <br />16" / VAPOR BARRIER LU <br />Z <br />0 <br />3 BEARING WALL FOOTING SECTION <br />z <br />W <br />CONCRETE SLAB W/ 6x6 W <br />W1.4 x W1.4 WWF OR LU <br />FIBERMESH <br />0'-0" A.F.F. 0 <br />- SEE ARCH O <br />°- a \° DETAILS 0) <br />MIN <br />0" 8 <br />\, 0 0 <br />8"x8" THICKENED 8" Z Q LUJ <br />FTG AT U) <br />STEP-DOWN, SEE VAPOR BARRIER (/) �/ <br />PLAN W 10 <br />CURB STEP SECTION ? �� z W <br />4co <br />o cn <br />w J _ <br />8" UNDER MASONRY WALL LU <br />W <br />-- Z O <br />CONCRETE SLAB W/ 6" UNDER WOOD WALL 0 <br />6x6 W1.4 x W1.4 WWF ° — - Z Q Q <br />OR FIBERMESH VARIEE <br />SEE ARCH W W W OLLJ <br />— — ° (MAX 16") J <br />LU W <br />a — - <br />\� <br />° / 12" MIN. ILL <br />\/i Z <br />, <br />VAPOR BARRIER �// a d /i, //�/ 0 T , .;S n:::r.,n e. ectroricaiiy <br />6" OPT. EXTENSION IN BRICK shown using a ;if,;,;t ! S1,w- w! ? 0 <br />LOCATIONS ON FND PLAN �'';r! e:rS ca ,; ;s of this t cx.:.,rru: t;t ;re LLJ <br />O .?G4. COt?5:(1E rE?C is (;f?Er:] 1— <br />a ant] ih!e Sil nmu? e must, t!e vt'r:iir'd Z <br />12" UNDER 1 STORY WALL w/ <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 ;_c'pY LaL <br />BAR IN BRICK LEDGE U <br />16" UNDER 2 STORY WALL W/ Q U_ <br />(2) #5 OR (3) #4 CONTINUOUS 0 W <br />Abbott Park Q <br />5 GARAGE EXT �ALL <br />CURB SECTION p <br />CONTACT FOR PRIOO CONSTRUCTION IF ANY OF THE - <br />FOLLOWING OCCUR: Q LOT 030-03 0 <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" - <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY ~ <br />FROM STRUCTURE STEEPER THAN V-0" VERTICALLY z Z <br />PER T-0" HORIZONTALLYfO PREVENT EROSION OF SOIL. — (D <br />(D cn <br />CONCRETE SLAB W/ 6x6 <br />PROJECT NO: W <br />W1.4 x W1.4 WWF OR 0 <br />FIBERMESH O 2021.009226 ILL <br />0'-0" A.F.F. SEE ARCH Z DRAWN: O <br />-� — — a — — (MAX 20" = CD 8 <br />q ° d ° — a a - -- DEEP) CHKD: <br />\, \\ \ K 4„ X MJ P _ <br />4" EXTENSION Q Q <br />UNDER BRICK VENEER `011111111111IN L <br />', <br />12" UNDER 1 STORY WALL �•�� JJ�J.."* �'AN�F,4 <br />W/ (2) #4 OR (2) #5 CONT VAPOR BARRIER > �� �C N S 0 <br />16" UNDER 2 STORY WALL 0 No 85166 <br />W/ (3) #4 OR (2) #5 CONT W * ; Docusie�ea ny: <br />Z = *: h- <br />BEARING CURB STEP SECTION 0 0 .. S I D7,eFEF 3. .. <br />6 W <br />� � F• O R � �• . C� <br />� I I <br />TYPICAL REINFORCI <br />BARS AT THICKENE <br />FOOTING, SEE PLAN <br />MIN 24" LONG #4 O <br />BAR SET AT MID -DE <br />OF SLAB, TYP ALL <br />RE-ENTRANT CORN <br />AB <br />-- — — — — --- - <br />HOUSE SL <br />RE-ENTRANT CORNER DETAIL <br />(RECOMMENDED) <br />PLAN VIEW, DETAIL TYPICAL @ ALL <br />RE-ENTRANT CORNERS <br />NG Z A� �%%% <br />D (n <br />O 07-29-2021 <br />R #5 ~ W <br />PTH (~LL <br />j co <br />REVISIONS: 2 <br />ERs Q No. Description Date w <br />— co <br />O Z <br />= --- o <br />U <br />W <br />X ST=2D <br />W <br />0- <br />Q <br />CMUIMETAL CONNECTOR ENGINEERING <br />
The URL can be used to link to this page
Your browser does not support the video tag.