Laserfiche WebLink
THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METAL LATH <br />16GAx1-1\2" LONG (3/4"-1" CROWN) <br />STAPLES @ 6" O.C. VERT BETWEEN <br />STUDS (NOTED THUS:—) - OFFSET <br />STAPLES BETWEEN STUDS AS SHOWN <br />WALL SHEATHING <br />16GAx1-1/2" LONG (3/4%1" <br />CROWN) STAPLES @ 6" <br />O.C. VERT INTO STUDS <br />(NOTED THUS:—) <br />METAL LATH ATTACHMENT DETAIL <br />REV. 09.24.21 SCALE: 3/4" = V-0" <br />*DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 703.7.1 LATH* <br />**ONLY APPLIES TO LENNAR TPA/JAX** <br />10'-0" <br />TANK -LESS W/H <br />CORNER OF <br />L <br />HOME H C G <br />GARAGE SIDE 0 0 O <br />5'-0" a - <br />c� <br />STUB -OUT FOR 1'-0" 0 9 c <br />GAS METER 0 o <br />� U <br />o <br />CV <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />**ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />7'-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />1 SIMPSON HTS20 OR 3 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />1 SIMPSON HTS20 OR 4 16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />164" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />rTOENAL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />SOUTHERN YELLOW PINE, 55 PSF LOADING <br />U <br />Backer and Filler Block Dimensions <br />BCI Joist <br />Backer Block <br />Series <br />Thickness <br />Filler Block Thickness <br />3/4" orp <br />5000s 1.8/1.7 <br />nel <br />wood panels <br />Two 3/4" wood panels or 2 x _ <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x — + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2 x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />1/8" gap <br />r <br />J <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4) Place joists together and nail from each side with 2 rows of 10d nails <br />2x-: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite <br />OF THE JOIST ASA REQUIRED LEAVING Y8" GAP @ TOP sides by 6". <br />DOUBLE JOIST CONNECTION <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />* Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />wall or beam below.* <br />consideration. Check <br />local building <br />code for appropriate <br />1/16 <br />details in <br />One 10d box <br />areas=20 of high <br />or=20 sinker <br />lateral load. <br />1 <br />T nail each side <br />at bearing. <br />Squash block / <br />(2x4 minimum) —I <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />Boise Joist Blocking <br />1lca 3" /1r1r11 nails at A" n r <br />"_T Provide adequate bearing <br />for each lapped joist. <br />todnails SECTION @ INT. BRG. WALL <br />N.T.S. <br />NO HOLES (EXCEPT MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D (KNOCKOUT EXEMPTS) <br />(see table below) D <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />FILL CELL STD. 900 HOOK BOND BEAM <br />w <br />CONT. #5 > STD. 900 <br />HOOK <br />BAR <br />CONT. #5 <br />BAR <br />— #5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />v BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN PLYWOOD FLOOR <br />SEE PLAN FOR REQ'D ! ! �l— <br />COLUMN AND _ ;,_:: _= ' SHEATHING PER PLAN <br />CONNECTION l <br />1._ TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />FL MASONRY WALL OR <br />INTERIOR BRG. WALL <br />' TJI PER PLAN <br />i OTHERWISE SOLID <br />BLOCKING TO MATCH <br />Solid block all posts from # OF 2nd FLOOR <br />above to bearing below. STUDS <br />SECTION @ INT. BRG. WALL <br />N.T.S. <br />1/8" min. }Small gap 2 min. <br />2" max. 4' max. Web Stiffener Fastener Schedule i <br />i <br />Joist Bearing Location <br />Series F Dept -- End Intermediate <br />- rm d_ - -__- te <br />BCI 5000s 11-7/8 2-8d 34d <br />- AP 2-8d i 5- <br />Clinch nails ®' 9-1/2" 2-8d_ 2-8d <br />when 'BCI 6000s 11-7/8" 2-8d - 3-8d <br />r ', <br />possible � BCI 6500s® 14" 2-8d 5-8d <br />16" 2-8d 6-8d <br />11-7/8" 2-8d 3-8d <br />-- - <br />- - BCI60s 14" 2-8d 5-8d <br />Tight fit _J 16 2-8d 6-8d <br />2x4/Plywood/OSB web stiffener 2" min. gCl 90s® 11 7" 3-16d 3-16d <br />14" 5-16d 5-16d <br />required when indicated or 4" max. 16" 6-16d 6-16d <br />- Hangers with side nailing. <br />- Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />- Birdsmouth cuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : - for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration. <br />6„ A 1y" ROUND HOLE MAY --° 6" <br />BE CUT ANYWHERE IN CANTILEVER <br />THE WEB. PROVIDE AT <br />LEAST 3" OF CLEARANCE <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Yz" <br />DO NOT CUT HOLES <br />LARGER THAN 1Yz" <br />ROUND IN <br />CANTILEVERS. <br />LC <br />Z 'OVA <br />M. <br />y.7JF <br />P, STn'v.6• <br />..h <br />' ti+5+. <br />N^ <br />�.,•'-. •Y` <br />X <br />�'�'{nrY:.6 <br />4:b <br />, ..* <br />77 <br />.. y�' <br />8 <br />11-0" <br />1-1" <br />1' 2" <br />1 2' <br />V-3" <br />T-3' <br />T-T' <br />V-11 " <br />7-4" <br />7-9 <br />3 2" <br />3 -T' <br />12 <br />T-9' <br />T-1" <br />1' 2" <br />1-2" <br />T-3" <br />T-9' <br />24' <br />2'-11 ". <br />S-T' <br />4' 2' <br />4-9" <br />5'4" <br />Any 16' joist <br />16 <br />T <br />T-1" <br />1' 2" <br />1-2" <br />1'-T' <br />2-5" <br />3-2 <br />3-10" <br />4-9' <br />6-T' <br />64" <br />T 2" <br />Spun (1t) <br />20 <br />1'- <br />T-1" <br />1'2" <br />1-2" <br />7-0 <br />3-9* <br />4'-0 <br />4'-10" <br />5'-11" <br />fi-11" <br />7'-11" <br />f3'-11'" <br />24 <br />1 1'4Y" <br />I T-1" <br />T-2" <br />V-3" <br />2-6' <br />1 3--P* <br />4'-9' <br />6-10" <br />1 T 2" <br />8'-4" <br />9-6" <br />101-9" <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1y" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />1-When joists meet over wall, provide <br />1 3/4" minimum bearing for each. <br />Plumbing <br />Joist <br />I -Joist can be offset <br />123 <br />up to 3" to avoid <br />vertical plumbing e. <br />3" max <br />JOISTS OFFSET <br />N.T.S. <br />Backer block (12" wide min.) <br />Nail with 10-10d nails. <br />., Install fight to. top flange. <br />Joist hanger <br />Filler block. <br />\ Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gap <br />i <br />Backer Block ��' 1 <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />:I=': requirements <br />�'� 0.6 X Joist <br />r i j le p/ depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />SIMPSC <br />w/ (22) <br />NAILS I <br />5/8"0 <br />THRU <br />BOLT <br />SIMPSC <br />w/ (22) <br />NAILS I <br />R TRUSS <br />'OP PLATE <br />I.0 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />AIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON META12 / <br />META12 TSS INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />SLEEVE THRU STEMS • ' <br />SEE PLAN FOR •• • . • <br />FOUNDATION INFO a • a <br />STEM FOUNDATION <br />GRADE <br />. a <br />REINF. SEE PLAN <br />A/C CHASE 4" PVC <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />yLj <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />ir <br />LOCATION OF <br />SECOND H10A <br />SIMPSON H10A ° ° ° (WHEN <br />w/ (18)10d x 1 1/2° K-- REQUIRED) <br />NAILS <br />UPLIFT = 1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />! O <br />4 <br />a <br />0 <br />-III,I�I�IIIII � � i <br />12" BELOW <br />GRADE <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE VERTICAL THRU FND. <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />° q <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION PLUMBING LINE <br />d <br />d °v L <br />H I 1-1 11=1 1=1 11=1 I I: <br />° a °`I- <br />11 <br />_ O 4 <br />i-_A__-..a.. <br />a <br />SEE FND. PLN. <br />0. SIZE & REINF. <br />No <br />c%.A <br />� <br />c <br />g <br />O <br />w <br />LJ <br />ro <br />2:— c <br />V) <br />N % G <br />N -G O <br />d <br />o Q <br />T <br />�E <br />�o <br />Q. U <br />`c+ <br />"''. <br />i`� C t•. 4 <br />Y <br />r?9 <br />✓ <br />F'� A•'• <br />'' �o <br />L <br />.. • • <br />N <br />To the best of the Engineers knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />a <br />c E <br />o <br />O M $ <br />0 <br />„"LL <br />W <br />yrNiv <br />o <br />_Z <br />m'crn 0 <br />tmo 0,a <br />i <br />o <br />j 20 N O - J Q <br />oto gl` d m <br />°'°' ow <br />W <br />6 J <br />z (8LLW <br />VZ <br />O U ❑❑❑ <br />W <br />(D <br />x3 <br />z N <br />z <br />z <br />t,n <br />iY <br />M <br />z <br />C1 <br />a--+ <br />w <br />_ <br />�U <br />° <br />-- g <br />0 <br />w <br />VV) <br />® <br />W R <br />t 8 <br />o <br />a <br />Oki <br />9 <br />o <br />i� <br />M <br />� <br />Q <br />Q <br />E <br />so <br />a <br />�® <br />U <br />V <br />oW <br />V O <br />z <br />4 <br />L <br />3 <br />C <br />OCY' <br />7z <br />z <br />mS .v <br />d <br />Q W <br />$ z <br />a <br />o° <br />U <br />W <br />�JJ <br />T <br />m <br />wW <br />ag'z <br />NI <br />2� <br />c O <br />0 <br />> 00 <br />U <br />fa <br />L_ <br />rn <br />m <br />m <br />,�-.. <br />M� <br />L <br />(D <br />00 <br />CN <br />M <br />U11) <br />ICU <br />iz <br />C <br />CV <br />T <br />/"r N <br />OTO <br />o(� <br />U <br />T <br />r <br />m <br />N <br />CV <br />�— <br />0 <br />W <br />CN <br />00 <br />N N <br />M <br />O <br />N <br />cfl <br />r <br />M ,= <br />r <br />ci <br />A, <br />M <br />M <br />�; i <br />o <br />M <br />z <br />E T <br />4? <br />- <br />c <br />a <br />0 <br />v <br />c <br />JOB <br />NO : 23 05741-05746 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />SN 1 <br />