My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36453 Well Hill Way
Zephyrhills
>
Building Department
>
Building Plans
>
36453 Well Hill Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 10:38:55 AM
Creation date
2/27/2025 11:16:38 AM
Metadata
Fields
Template:
Building Plans
Street #
36453
Location
Well Hill Way
Contractor
Lennar Homes
Building Plans - Permit #
6593
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150A1200A INDOOR <br />PANEL CENTER <br />P #14 to lights & outlets <br />NEMA 1 10 #12 to appliances and GFI <br />150 AW <br />200 AMP 10 #10 to WH <br />10 #8 to Range <br />of #6 to HVAC <br />METER <br />n <br />1 50=2/0 <br />WP <br />A/C PAD <br />00=4/0 in 2" Conduit <br />GFI DISC. <br />200 amp <br />150 amp <br />6 <br />UNDERGROUND <br />is nnerd <br />- - - - - - - - - - - - - - - - - - - - - - - <br />SERVICE BY POWER CO <br />15-1 <br />INTERSYSTEM <br />I <br />4 Bare Cu Ground <br />BONDING <br />TERMINATION PER <br />#4 GROUNDING WIRE <br />WITH CODE APPROVED <br />LANAI <br />NEC 17, 250.94 CLAMP PER 250.50 AND <br />WP <br />250.52 OF THE 2017 NEC. <br />rlp:l <br />Kinni< <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser DiagraM REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />1. Electrical outlet heights as measured hom finished "oor to nLer fine Of the WOX LO be: 16 Ar r kgenerai). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12"AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centedine above finished floor. <br />4. Electrical plan Is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance With UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the Installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />I ELECTRICAL KEY I <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />WEATHERPROOF DUPLEX OUTLET <br />t"Z:7"G F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />L.(-7h <br />I '�_-'v <br />SPECIAL PURPOSE OUTLET <br />F/_\1 <br />::Eff <br />DUPLEX OUTLET IN FLOOR <br />k(�)E <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />6. <br />�R4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />3::� <br />CEILING MOUNTED LIGHT FIXTURE <br />7'N <br />N-A <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />�_o <br />WALL MOUNTED LIGHT FIXTURE <br />(:§) <br />RECESSED LIGHT FIXTURE <br />#P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />7CH <br />CHIMES (OPTIONAL) <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />FTV1 TELEVISION (OPTIONAL) <br />FT -VI 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60' A.F.F. <br />THERMOSTAT <br />�9 ELECTRIC METER <br />1111111071 ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />OPT. CEILING FAN <br />G� <br />(1) PHONE LINE, (1) DATA PORT <br />1.5" VTR <br />-111 3" VTR I <br />f <br />141, xrrp <br />r I <br />SWITCH FOR <br />DISPOSAL <br />PLUMBING RISER <br />KITCHE <br />SCALE:NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />I- DEDICATED <br />RECEPTACLE FOR <br />ICROWAVE RANGE <br />HOOD PER SPECS <br />SPEC 3 & 4 KITCHEN <br />1.- 1. off <br />SCALE. 4 <br />B <br />ENTRY <br />WP <br />DB&GFI TO GFI <br />BE ALIGNED - - - - - - - <br />VERTICALLV <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS <br />cr CC <br />Z <br />0 <br />on <br />Lu 0 <br />> _j <br />COACH LIGHTS COACH LIGHTS <br />OR PREWIRE AS OR PREWIRE AS <br />PER SPECS PER SPECS <br />FIRST FLOOR ELECTRICAL PLAN - ELEV-B <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />L---------- <br />L--------------------------------------- i <br />SECOND FLOOR ELECTRICAL PLAN <br />ELEV-B <br />C-4 <br />E <br />3: cc <br />du W <br />cu <br />= . !2 <br />W <br />r= <br />To the best of the Engineers knoWedge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code <br />- <br />Residential 7th Edition. Engineer's signature and seal <br />is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />a <br />W <br />0 <br />C14 <br />04 C6 Cb <br />61 <br />0 <br />4 <br />(1) r- u. Lu <br />04 0 <br />9 C", 14. ot <br />-9 LL LL <br />Z <br />2M <br />0 <br />0 <br />CZf <br />Z <br />ILW <br />Lu <br />, 04 SO X <br />N 05 P <br />CN <br />U) <br />cl- G <br />1- <br />V) <br />PI <br />21 Of <br />(D I <br />(1) <br />4.-j </�' <br />LL' <br />c' <br />0 <br />g <br />V) <br />c-_- - <br />C) 2! <br />LU <br />Cn <br />C-1. <br />U_ <br />E <br />W 6� <br />0 <br />0 <br />C' <br />ZE <br />M <br />W t <br />Z <br />'0 <br />10 <br />Z <br />Z <br />W <br />A <br />C <br />CW: <br />0 <br />CY) <br />C <br />ICU LO <br />LO <br />Cr <br />ca <br />(J) <br />CN <br />4-J <br />L0 <br />U <br />75 <br />C" <br />0 <br />U') <br />CN <br />W <br />E <br />-k� <br />. C N <br />CY) <br />�i LO <br />0 <br />W <br />Z <br />=1 <br />E T_ <br />E <br />V) <br />42) <br />M <br />a. <br />0 0 <br />1 0 _j <br />M <br />:<0 0 <br />JOB <br />NO: <br />23-06107 <br />SCALE : <br />AS NOTED <br />SHEFr NO. <br />3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.