I r`
<br />MIRROR
<br />OWNER'S BATHROOM
<br />SCALE: 3/8" =V-0"
<br />BATHROOM 2
<br />SCALE: 3/8" = V-0"
<br />0
<br />F-
<br />4
<br />WINDOW SCHEDULE
<br />SIZE
<br />R.O. CMU
<br />(Flange)
<br />R.O. FRAME
<br />(Fin)
<br />TYPE
<br />12
<br />20X26
<br />18JX25}
<br />S.H.
<br />13
<br />20X381
<br />18JX37i
<br />S.H.
<br />14
<br />20X501
<br />184X50
<br />S.H.
<br />15
<br />20 X 63
<br />18 4 X 62 }
<br />S.H.
<br />16
<br />20X72
<br />184X71}
<br />S.H.
<br />11-12
<br />271/4X26
<br />26X25}
<br />S.H.
<br />1H3
<br />271/4X38
<br />26x371
<br />S.H.
<br />1 H4
<br />27 J X 50 J
<br />26 x 50
<br />S.H.
<br />1115
<br />27JX63
<br />26X621/2
<br />S.H.
<br />11-16
<br />27JX72
<br />26X711/2
<br />S.H.
<br />22
<br />37JX26
<br />36}X251/2
<br />S.H.
<br />23
<br />37 J X 38 lJ
<br />36 J X 37 3/4
<br />S.H.
<br />24
<br />37 J X 50 J
<br />36 } X 50
<br />S.H.
<br />25
<br />37 J X 63
<br />36 J X 62 1/2
<br />S.H.
<br />26
<br />37JX72
<br />36JX711/2
<br />S.H.
<br />DOUBLE 2 WIDE
<br />75" TALL
<br />73 � WIDE
<br />S.H.
<br />32
<br />54 X 26
<br />52 J X 25 }
<br />S.H.
<br />33
<br />54 X 38 J
<br />52 4 X 37 J
<br />S.H.
<br />34
<br />54X50J
<br />524X50
<br />S.H.
<br />35
<br />54 X 63
<br />52 } X 62 J
<br />S.H.
<br />36
<br />54 X 72
<br />52 } X 71
<br />S.H.
<br />39X59
<br />40 X 59
<br />N/A
<br />S.H.
<br />DOUBLE 39X59
<br />79 X 59
<br />N/A
<br />S.H.
<br />STAIR DATA:
<br />18 RISERS @ 7.153"
<br />17 TREADS @ 10"
<br />TOTAL RISE = 10'-8 3/4" DRYWALL
<br />TOTAL RUN=14'-2" 42" KNEE WALL
<br />WITH 1x8 CAP &
<br />3/4" PLYWOOD �� CASING (AT 2nd 1 1/2" MIN. CLEARANCE
<br />DECKING �� FLOOR ONLY)
<br />(2) 2X8 w/ 1/2"
<br />�FLITCH HEADER
<br />SLOPE CEILING TO
<br />MATCHSTAIRRISE _
<br />F. FL. �y--- F. FL.
<br />18
<br />T7-
<br />17 1 1/4" TO 2" DIA
<br />16 �� HANDRAIL NO
<br />15 LESS THAN 34"
<br />14NOR MORE
<br />13 U THAN
<br />38N
<br />Z " ABV.
<br />SING
<br />CONT. TREO
<br />12 11
<br />HAND RAIL METAL
<br />HANDRAIL
<br />BRACKET
<br />BLOCKING AS
<br />REQUIRED
<br />F. FL.
<br />HEADER SCHEDULE
<br />MARK
<br />HEADER SIZE
<br />REMARKS
<br />H 1
<br />(2) - 2X6 #2 SYP W/ 1/2"
<br />FLITCH PLATE
<br />H2
<br />(2) - 2X8 #2 SYP W/ 1/2"
<br />FLITCH PLATE
<br />H3
<br />(2) - 2X10 #2 SYP W/ 1/2"
<br />FLITCH PLATE
<br />H4
<br />(2) - 2X12 #2 SYP W/ 1/2"
<br />FLITCH PLATE
<br />H5
<br />(2) - 1 3/4" X 11 1/4 LVL
<br />2.0E Fb=2950
<br />H6
<br />(2) - 1 3/4" X 9 1/4"
<br />LVL 2.0E Fb=2950
<br />H7
<br />(2) -1 3/4" X 16"
<br />LVL 2.0E Fb=2950
<br />H8
<br />(2) -1 3/4" X 7 1/4"
<br />LVL 2.0E Fb=2950
<br />(2) - 2X4 #2 SYP W/ 1/2"
<br />Follow Q/S4. See Plan for
<br />RAG
<br />FLITCH PLATE
<br />Bearing Wall Call Out When
<br />Straps are Required
<br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED
<br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND
<br />REQUIRED STUDS
<br />Stair and Railing General Notes
<br />Stairway construction shall conform to the FBC Residential 7th Edition (2020) sections R311.7, R312
<br />and R302.7.
<br />Riser height:
<br />The riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading
<br />edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by
<br />more than 3/8 inch.
<br />Tread depth:
<br />The tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the
<br />vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The
<br />greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch.
<br />Winders:
<br />Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the
<br />foremost projection of adjacent treads at the intersections with the walkline. Winder treads shall have a tread
<br />depth of not less than 6 inches at any point within the clear width of the stair.
<br />Nosings:
<br />Nosings at treads, landings and floors of stairways shall have a radius of curvature at the nosing not greater than
<br />9/16 inch or a bevel not exceeding '/2 inch. A nosing projection not less than 3/4 inch and not more than 11/4
<br />inches shall be provided on stairways. The greatest nosing projection shall not exceed the smallest nosing
<br />projection by more than 3/8 inch within a stairway.
<br />Handrails:
<br />Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more
<br />risers. Handrail height measured vertically from the sloped plane adjoining the tread nosing, or finish surface of
<br />ramp slope, shall be not less than 34 inches and not more than 38 inches. Handrails for stairways shall be
<br />continuous for the full length of the flight, from a point directly above the top riser of the flight to a point directly
<br />above the lowest riser of the flight. Handrail ends shall be returned or shall terminate in newel posts or safety
<br />terminals. Handrails adjacent to a wall shall have a space of not less than 11/2 inches between the wall and the
<br />handrails.
<br />Grip -size:
<br />Handrails with a circular cross section shall have an outside diameter of not less than 11 /4 inches and not greater
<br />than 2 inches or provide equivalent grasp -ability in compliance with Section R311.7.8.3.
<br />Guards:
<br />Guards shall be provided for those portions of open -sided walking surfaces, including stairs, ramps and landings,
<br />that are located more than 30 inches measured vertically to the floor or grade below at any point within 24 inches
<br />horizontally to the edge of the open side. Required guards at open -sided walking surfaces, including stairs,
<br />porches, balconies or landings, shall be not less than 36 inches in height as measured vertically above the
<br />adjacent walking surface or the line connecting the leading edges of the treads. Required guards shall not have
<br />openings from the walking surface to the required guard height that allow passage of a sphere 4 inches in
<br />diameter.
<br />Under -stair protection:
<br />Enclosed space under stairs that is accessed by a door or access panel shall have walls, under -stair surface and
<br />any soffits protected on the enclosed side with 1/2-inch gypsum board.
<br />o0
<br />Y
<br />T
<br />18'-4"
<br />VERIFY
<br />AC PAD LOCATION OF
<br />A/C PAD
<br />HB
<br />688
<br />Now
<br />mom OUTDOOR LIVING
<br />M:::
<br />600
<br />160864 CONCRETE
<br />L. 6'-8" L&
<br />3'-10" T-10" 2'-8"
<br />oQ
<br />6068 SGD
<br />® ■
<br />■
<br />000
<br />_
<br />5-SH
<br />�
<br />T
<br />O
<br />N
<br />2468 REF
<br />IBM 7'-11"
<br />3'-2"
<br />6-7"
<br />'
<br />o I
<br />O
<br />o C
<br />O vi
<br />rf)cv
<br />CLOl)DINING
<br />KITCHEN
<br />Q41F
<br />L3
<br />o
<br />9'-4" FLAT CLG.
<br />9'-4" FLAT CLG.
<br />® TILE
<br />TILE
<br />OP
<br />SINK w/
<br />I
<br />D/W DISPOSAL
<br />--
<br />I
<br />I �0
<br />r---J
<br />U
<br />in
<br />I
<br />L J
<br />I
<br />FLRG. LINE
<br />2x8 WALL
<br />ED 8'-0" 6'-0"
<br />0
<br />16" CNTR. AT
<br />3'-8"
<br />o
<br />7 A.F.F.
<br />1 /2 WALL
<br />i;
<br />AO
<br />F,N
<br />CAPPED
<br />1
<br />UP 2
<br />=00 �
<br />55
<br />q
<br />co
<br />GREAT ROOM
<br />F
<br />TYP. U.N.O
<br />®
<br />9'-4" FLAT CLG.
<br />E
<br />CARPET
<br />7
<br />13'-8"
<br />-
<br />0
<br />M
<br />�
<br />GG f`
<br />c
<br />cD
<br />r
<br />S3
<br />1 C
<br />11
<br />o
<br />O u
<br />1
<br />N
<br />2x6 WALL
<br />6'-8" Lo
<br />2'-8" 4'-4"
<br />*NO UPLIFT*
<br />_
<br />Q
<br />_
<br />S4
<br />�- - -
<br />iv
<br />FLRG. LINE
<br />H 1
<br />N f3{ /f,fp
<br />/�
<br />o
<br />( =
<br />TILE
<br />CrJQ
<br />�T
<br />T-
<br />fV c0
<br />( U) CV
<br />N
<br />I �
<br />• FOYER
<br />'
<br />9'-4" FLAT CLG.
<br />2868
<br />TILE
<br />�0
<br />p-
<br />~ �T.O.M
<br />cv W.H.
<br />in
<br />91-4"
<br />7'-0"
<br />O
<br />2'-6"
<br />© 3068
<br />BUILDER TO
<br />■
<br />PROVIDE
<br />APPLIANCE
<br />2'-0' 4'-0" -0"
<br />PROTECTION
<br />I„
<br />WHEN
<br />°0
<br />2, - 4 8„
<br />REQUIRED PER
<br />E N Y z
<br />FBC
<br />9'-4" PLG. A.F.F.
<br />1-CAR
<br />'ARAGE
<br />CONCRETE
<br />- _
<br />9'-4" F
<br />CONCRETE
<br />T CLG.
<br />■a
<br />■
<br />9
<br />N
<br />STONE
<br />600
<br />T ~
<br />VENEER
<br />16"
<br />SQUARE
<br />b
<br />CMU
<br />COLUMN
<br />in
<br />r----------
<br />------t
<br />fp 0
<br />c0
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />0
<br />NJ
<br />I LINE OF 2nd STRY.
<br />ABV.
<br />Oo
<br />I **NOTE'*
<br />cop
<br />I BLK. WALLS
<br />RE 8'-8"
<br />TALL FOR "A" UNIT
<br />5'-8"
<br />o HB
<br />i FROM FRONT
<br />OF
<br />Ln
<br />K GARA
<br />E
<br />I TYP, @
<br />I
<br />I S4 GARAGE
<br />0
<br />N
<br />8'x7' GARAGE
<br />OOR
<br />"M
<br />1 V-4"
<br />L 18,-4„
<br />1ST FLOOR PLAN - UNIT -A 1532
<br />SCALE: X"=1'-0"
<br />D1
<br />STONE
<br />1'-8" VENEER
<br />io
<br />0
<br />ih
<br />N
<br />FILLED CELL LEGEND
<br />CONT. FILLED CELL FROM FOUNDATION TO 2ND
<br />FLOOR
<br />® FILLED CELL BELOW 2ND FLOOR (DOWEL INTO
<br />LINTEL)
<br />® FILLED CELL ABOVE 2ND FLOOR (DOWEL INTO
<br />BOND BEAM)
<br />row
<br />10
<br />3'4" 12'-0" S-0"
<br />7011
<br />1'4" V-8" T-10" 5'-0" T-10" 2'-8"
<br />40
<br />© O
<br />MOD 25 SH MOD 25 SH
<br />(39"x59") (39"x59")
<br />■I' ® ® ■
<br />EGRESS I EGRESS
<br />OWNER'S
<br />55
<br />BEDROOM
<br />D1
<br />TYP. U.N.O. = 8'-0" FLAT CLG.
<br />t I
<br />® CARPET
<br />o
<br />N
<br />�o
<br />17'-8"
<br />io
<br />ifl
<br />6,-4„ 4,-4„ 7,4„
<br />® M.C. - - - - - R&S
<br />------
<br />0. B TH I 22"x36"
<br />8'-0" FLA CLG. ATTIC
<br />ACCESS I C I
<br />N
<br />c
<br />CARP T ,1
<br />0 N °° 1 /" FLAT CLG I(
<br />Cl)-
<br />N I 1, � ICARPET
<br />PW01
<br />®N /
<br />® --- ----J
<br />R&S
<br />A - FO '
<br />N
<br />^ 28s8
<br />X 61
<br />_
<br />- I v 7
<br />;0
<br />u�
<br />T A. _ (0 8
<br />,
<br />is
<br />tV
<br />60"x AH U
<br />r
<br />o0
<br />WER P I 10
<br />CD
<br />R!A
<br />5' 114' 4,„ 1. 3,_4„ I I 3,_8„
<br />,
<br />- ; LOFT 13
<br />® T 8'-0" FLAT CLG. 14
<br />4
<br />LO
<br />00 1-CARPET 1
<br />00
<br />16
<br />I
<br />v7
<br />I 17
<br />ran
<br />- I Up 8
<br />7' A.F.F. A L-�
<br />4 1/2 WALL
<br />I ba CAPPED
<br />=9'-6"
<br />1'-10" N•Or-
<br />CV
<br />M
<br />;
<br />V�QB�ATH
<br />io
<br />N0
<br />1-0" 2668
<br />�
<br />CLG
<br />_O
<br />T.. 01
<br />I WIC
<br />8'.0" FLAT CLG.
<br />(V
<br />CARPET 2668
<br />6)
<br />v
<br />o8 I
<br />Q
<br />iD
<br />rr
<br />is
<br />I M BEDROOM 2
<br />R&S
<br />8'-0" FLAT CLG.
<br />■' CARPET
<br />_
<br />Ma G.T.
<br />T
<br />G.T.
<br />80
<br />in
<br />©
<br />LO
<br />LO
<br />MOD 25 SH
<br />( 39" x 59" )
<br />EGRESS
<br />T-8" T-10" 3'-10"
<br />4'-0" 7,4„
<br />4
<br />7'-0" l V-4"
<br />�
<br />u7
<br />18'-4"
<br />- - - -- -- - ,.... _. _ _
<br />7J
<br />2ND FLOOR PLAN -UNIT-A 1532
<br />SCALE: Ya"=V-0"
<br />OPENING PRESSURES
<br />ENCLOSED-EXPOSURE"C"
<br />�A
<br />+29.7 / -32.2
<br />©
<br />+29.7 / -39.7
<br />+28.3 / -30.8
<br />OD
<br />+28.3 / -37.0
<br />�E
<br />+26.6 / -29.1
<br />�F
<br />+26.6 / -33.5
<br />OG
<br />SEE SN SHEET SEE SN SHEET
<br />140 MPH
<br />NOTE: WIND SPEED INDICATED ABOVE IS AN
<br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES
<br />LISTED ABOVE ARE ALLOWABLE PRESSURES
<br />SOFFIT DESIGN PRESSURE
<br />1 +29.7 / -39.7
<br />General Notes
<br />R302.5 Dwelling/Garage Opening/Penetration Protection
<br />Opening and penetrations through walls or ceilings separating the
<br />dwelling from the garage shall be in accordance with sections
<br />R302.5.1 through R302.5.3.
<br />R302.5.1 Opening Protection
<br />Openings from a private garage directly into a room used for
<br />sleeping purposes shall not be permitted. Other openings between
<br />the garage and residence shall be equipped with solid wood doors
<br />not less than 1-3/8" in thickness, solid or honeycomb -core steel
<br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors.
<br />R302.5,2 Duct Penetration
<br />Ducts in the garage and ducts penetrating the walls or ceilings
<br />separating the dwelling from the garage shall be constructed of a
<br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid
<br />nonmetallic class 0 or classl duct board, or other approved
<br />material and shall not have openings into the garage.
<br />R302.5.3 Other Penetrations
<br />Penetrations through the separation required in Section R302.6
<br />shall be protected as required by section R302.11, Item 4.
<br />R302.6 Dwelling/Garage Fire Separation.
<br />The garage shall be separated as required by Table R302.6.
<br />Openings in garage walls shall comply with Section R302.5.
<br />Attachment of gypsum board shall comply with Tab;e R702.3.5.
<br />The wall separation provisions of Table R302.6 shall not apply to
<br />garage walls that are perpendicular to the adjacent dwelling unit
<br />wall:
<br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or
<br />equivalent applied to garage side.
<br />• From Habitable Rooms Above Garage - Not Less than 5/8"
<br />Type-X Gyp. Bd. or equivalent.
<br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less
<br />than 1/2" Gyp. Ed. or equivalent.
<br />• Garages Located Less Than 3 Feet From Dwelling On The
<br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied
<br />to the interior side of exterior walls that are within this area.
<br />R312.2.1 Window Sills
<br />In dwelling units, where the top of the sill of an operable window is
<br />located less than 24 inches (610 mm) above the finished floor and
<br />greater than 72 inches (1829 mm) above the finished grade or
<br />other surface below on the exterior of the building, the operable
<br />window shall comply with one of the following: 1. Operable
<br />windows with openings that will not allow a 4-inch-diameter (102
<br />mm) sphere to pass through the opening where the opening is in
<br />its largest opened position. 2. Operable windows that are provided
<br />with window fall prevention devices that comply with ASTM F2090.
<br />3. Operable windows that are provided with window opening
<br />control devices that comply with Section R312.2.2.
<br />Chapter 45 Private Swimming Pools
<br />Outdoor swimming pools shall be provided with a barrier
<br />complying with R4501.17.1.1 through R4501.17.1.14.
<br />M1507.2 Re -circulation of Air
<br />Exhaust air form Bathrooms and toilet rooms shall not be
<br />re -circulated within a residence or to another dwelling unit and
<br />shall be exhausted directly to the outdoors. Exhaust air from
<br />bathrooms and toilet rooms shall not discharge into an attic , crawl
<br />space or other areas inside the building.
<br />GAS APPLIANCES
<br />G.C. to verify location of gas riser before commencement of work.
<br />Where gas water heaters are installed. Water heaters shall be
<br />installed a min. of 18" above fir. per FBCR G2408.2. Except where
<br />appliances that are listed as flammable vapor ignition resistant.
<br />WALL LEGEND
<br />2-STORY MASONRY WALL w/
<br />177777771 1 1 1 BOND BEAM HGT. AT 10'-8"
<br />TOP AT 18'-8"
<br />MASONRY HGT. @ 9'-4" A.F.F.
<br />MASONRY HGT. @ 8'-8" A.F.F.
<br />MASONRY PARTY WALL
<br />TYP. 2x FRAME WALL
<br />BEARING WALL
<br />INTERIOR BEARING WALLS NOTED "FLOOR
<br />BEARING ONLY" ARE FLOOR SYSTEM
<br />SUPPORTING ONLY AND REQUIRES NO UPLIFT
<br />CONNECTORS TO FLOOR SYSTEM
<br />AREA TABULATION
<br />1ST FLOOR 677 S.F.
<br />2ND FLOOR 864 S.F.
<br />TOTAL 1541 S.F.
<br />GARAGE 246 S.F.
<br />LANAI 110 S.F.
<br />ENTRY 42 S.F.
<br />TOTAL SQ. FT. 1939 S.F.
<br />INSULATION REQ.
<br />LOCATION R-VALUE / TYPE
<br />EXT CONC WALL R-4.1 HIGH PERM
<br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED
<br />EXT FRAME 2 x 6 R-19 KRAFT FACED
<br />CONDITIONED CEILING R-30 BLOWN -IN
<br />(INSTALL BAFFLES AT EAVE)
<br />GARAGE SEPARATION R-11/R-13 KRAFT FACED
<br />(GARAGE / LIVING)
<br />OG.C. TO COORDINATE PLUMBING TO AVOID
<br />CONFLICT WITH STRUCTURAL WD. COL.
<br />N
<br />a
<br />N
<br />00
<br />O c
<br />0
<br />c r_ o
<br />Q
<br />y w
<br />o M
<br />rn .
<br />J G..
<br />M
<br />0
<br />ry
<br />1
<br />T
<br />y,tSS.rrfr,, o
<br />f.:TA E O�
<br />`j��r,`� � tit i�,< ,.\• l•'v• \����
<br />To the best of the Engineer's knowledge, information and belief,
<br />the structural plena and apeafications contained within these
<br />drawings comply with the 2020 Florida Building Code -
<br />Residential 7th Edition. Engineer's signature and seal is only for
<br />the structural engineering portions of the drawing pages bearing
<br />Engineers signature and seal.
<br />C E
<br />Ci N
<br />au
<br />La 0
<br />+ G
<br />(n C', ik LL
<br />Q CJ I LL
<br />W
<br />LL LL a
<br />Z warn a
<br />v
<br />£ a o
<br />r 04
<br />W cp °. n
<br />W
<br />IL Z d J
<br />�L N O U
<br />v
<br />W ❑ ❑
<br />z
<br />Q �
<br />- PI
<br />to z
<br />U �.
<br />0 W
<br />N
<br />� r
<br />U
<br />Rif
<br />U
<br />•
<br />o
<br />M
<br />� �
<br />z
<br />�j E
<br />Ci
<br />w
<br />Zs
<br />6 q
<br />a
<br />o
<br />E"
<br />=•
<br />!- r0
<br />O
<br />mo
<br />�a
<br />� O
<br />O
<br />Oa
<br />Z
<br />:?
<br />`
<br />-o
<br />aW
<br />wg
<br />EZ
<br />x I
<br />Z2¢
<br />m po'
<br />W�s
<br />8
<br />zo
<br />Qo
<br />U
<br />z
<br />m,
<br />�
<br />a =
<br />Z6
<br />U7r
<br />2 C)
<br />>r
<br />T
<br />ca
<br />N
<br />O
<br />i--
<br />11)
<br />LO
<br />O
<br />Co
<br />1
<br />N o.
<br />_Lo
<br />�i
<br />Y E
<br />O
<br />0o
<br />0 m c�
<br />L)
<br />o
<br />r-
<br />CV
<br />ate-+
<br />CV
<br />�-
<br />0
<br />LO
<br />+_
<br />M co
<br />LO
<br />6) CO
<br />LO
<br />N N
<br />o 1 to
<br />r-
<br />E
<br />t CV)c
<br />c
<br />E T >v
<br />n
<br />ci
<br />Q o
<br />_J
<br />JOB
<br />NO: 23-00582-00577
<br />SCALE : AS NOTED
<br />SHEET NO.
<br />3
<br />� 10
<br />9 U
<br />�. 8 o�
<br />7-- x
<br />- 6 Z
<br />5 g
<br />2x STRINGERS `� 4 °0
<br />-- 3
<br />'`�- 2 , F.FL. HANDRAIL DETAIL
<br />14'-2" 2x4 #2 SYP. P.T. THRUST SCALE: 3" =1'-0"
<br />BLOCK W/(2)-1/4"x 31/2"
<br />TAPCONS @ 16"o.c. AND
<br />TYP. STAIR SECTION 3" FROM EA. END.
<br />SCALE: 1/4" = V-0"
<br />
|