Laserfiche WebLink
u-t <br />rIs.- <br />CONT. HANDRAIL <br />RETURN TO_ <br />� WALL DETAIL. <br />A SCALE: NTS <br />STAIR CALCULATIONS: <br />TOTAL RISE = 10'-0 3/4" <br />(16) RISERS AT 7 -9/16" <br />10" TREADS w/ 3/4" NOSING <br />U <br />42" KNEE WALL WITH <br />1x8 CAP & CASING - <br />USP MP3 CLIP EA. - <br />STRINGER TO BEAM/ <br />FLOOR SYSTEM TYP. <br />16 M7 <br />i <br />36" H. CONT. <br />r <br />,'' 15 <br />GRASPABLE �''14 <br />_ <br />RAILING C:)' <br />I i ' 13 <br />I CY ' <br />I ' <br />' <br />I , 12 <br />I ' <br />10 <br />42" KNEE = <br />i <br />I ,' 10LOICO <br />WALL WITH oo <br />1 9 <br />1x TREAD <br />_ <br />"o <br />1x8 CAP & <br />,�' <br />(TYP.) - <br />o <br />CASING <br />8 STORAGE <br />I <br />00 <br />r <br />,,, <br />' 7 UNDER <br />00 <br />'6 <br />STAIRS <br />1x8 CAP & <br />; 5 2x FRAMED <br />CASING <br />,�' <br />I,%/4 WALL <br />i 1x RISERS <br />i <br />3 <br />(TYP.) <br />' 2 <br />(3) 2x12 <br />2x FRAMED <br />1 <br />STRINGERS <br />WALL <br />2x4 #2 SYP. P.T. THRUST BLOCK <br />W/(2)- 1/4"x 3 1/2" TAPCONS @ <br />16"o.c. AND 3" FROM EA. END. <br />TYP. STAIR SECTION <br />� SEE PLAN FOR LANDING DEPTH <br />MIN. (3) 2x STUDS R <br />@ END OF LANDINC <br />BELOW HDR. BEAM <br />STANDARD (3) 2x1 <br />STRINGERS w/ <br />SIMPSON A35/USP <br />MP34 CLIP TO <br />FLOOR SYSTEM O <br />LANDING FRAMIN( <br />(2) 2x HDR. <br />REQ'D @ EN[ <br />LANDING FOF <br />STRINGERS - <br />CONNECT TC <br />PLY SHEATHING OVER <br />LANDING ATTACHED PER <br />GENERAL FLOOR <br />CONSTRUCTION NOTES <br />2x8 #2 SYP JOISTS @ LANDING <br />@ 16"O.C. w/ SIMPSON A35/USP <br />MP34 OR LUS26 HANGER ON <br />EA. SIDE <br />MASONRY OR WOOD WALL, <br />SEE PLAN <br />2x8 #2 SYP (P.T. IF MASONRY <br />WALL) CONTINUOUS LEDGER <br />w/ (3) 16d NAILS @ 16" O.C. MAX. <br />TO EA. STUD. ((2) 1/4"X3 1/2" <br />TITENS @ 16" O.C. MAX. FOR <br />MASONRY WALL) <br />GENERAL LANDING FRAMING INFO._ <br />SCALE: N.T.S. 9'-0" MAX LANDING LENGTH <br />2x4 #2 SPF STUDS @ 16" <br />O.C. TYP. @ 2nd FLOOR <br />3/4" PLYWOOD EXTERIOR WALLS <br />DECKING <br />FLOOR SYSTEM <br />N <br />3 <br />D2 <br />SIM. W/ (1) <br />MSTAM36 <br />STRAPS @ <br />BASE <br />J <br />S6 <br />TYP. <br />U.N.O. <br />H1 <br />"*EGRE <br />U) <br />2 <br />w <br />N <br />U* <br />140C <br />REV 10.1.20 CAB <br />EXTERIOR 2ND FLOOR <br />BEARING WALL SCHEDULE <br />HEIGHT <br />STUD <br />SPECIES <br />SPACING <br />SPF #2 <br />8'-0" <br />2x4 <br />SYP #2 <br />16" O.C. <br />SPF #2 <br />9'-0" <br />2x4 <br />SYP #2 <br />16" O.C. <br />SPF #2 <br />>9'-0" <br />2x6 <br />SYP #2 <br />16" O.C. <br />* WHEN THE TOP OF WALL IS GREATER THAN 9'-0", THEN AT <br />EACH EXTERIOR CORNER WITHIN THE 4'-0" END ZONE, THE <br />STUDS WILL BE DOUBLE STUDS @ 16" O.C. OR SINGLE STUDS <br />@ 12" O.C.* <br />THIS IS ONLY USED WITH PLASTER OR STUCCO EXTERIOR <br />FINISH <br />** WALL SHEATHING 15/32" EXPOSURE 1 OR EQUIVALENT. <br />REFER TO SHEATHING SCHEDULE FOR ATTACHMENTS- <br />------------� <br />25'-0" I I <br />I I <br />I <br />I <br />61H1 1 <br />A ° � <br />TYP. <br />U.N.O. 25 SHI I <br />*EGRESS <br />OWNER'S <br />SUITE <br />8'-0" FLAT CLG. <br />CARPET <br />- OP - G.T. - <br />2668 <br />BF - <br />BEDROOM 4 <br />8'-0" FLAT CLG. <br />CARPET <br />1/2 WALL OR <br />RAILING PER SPECS <br />11'4° 2668 <br />io <br />LO <br />T-6' <br />60 X 36 C9Lo <br />- <br />SHOWER <br />FIBERGLASS <br />SURROUND <br />'TP <br />- 5'-0" 4'-0" <br />2668 - BAT H <br />8'- "FLAT CLG. 2018 <br />TILE LO BF <br />11 4-SH <br />�i R&S <br />WIC <br />- 8'-0" FLAT CL <br />(4„206 ,. CARPET I U) <br />1.j ca <br />RCQESS <br />R&S <br />-11" <br />91 <br />o7I CO T <br />=I `* 4 5 6 7 8 9 110 Ill 112 113 114 <br />R&S <br />2652 <br />-------N <br />R/A H <br />4068 = A <br />BF 51-1011 <br />r 3 <br />8'-0" FLAT CLG, <br />�4 TB <br />CV <br />i0 <br />TECH CENTER <br />7'-9„ <br />ouoa nr I <br />W. <br />LA U N ' <br />I <br />8'-0" FLAT CLG. <br />TILE <br />3'-10" 3'-11" <br />D. <br />9'-5�" <br />2 <br />3 <br />D2 <br />SIM. W/ (1) <br />6 <br />icy <br />I <br />MSTAM36 <br />G.T. <br />I <br />5068 <br />N <br />STRAPS @ - <br />- 11'-2" - - <br />2' <br />_ <br />" BF <br />s <br />11'-15" - - - <br />BASE <br />� <br />� <br />BEDROOM 2 <br />�I <br />oa; <br />BEDROOM 3 <br />8'-0" FLAT CLG. <br />I <br />8'-0" FLAT CLG. <br />CARPET <br />I <br />CARPET <br />*EGRESS I <br />CI <br />*EGRESS <br />2 SH 25 SH <br />H 1 9 © 39 22 D2 <br />D2 D1 D1 /\ <br />JAMB STHD C)VFR� XH1 � <br />ENTRY TO BE I v I <br />CONNECTED DOWN <br />PER DETAIL 6/D2 <br />6-8" 6-8" 5'-10" <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />RPEMARKS <br />H1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) - 1 3/4" X 91 /4" <br />LVL 2.0E Fb=2950 <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2950 <br />(2) - 2X4 #2 SYP W/ 1/2" <br />Follow Q/S4. See Plan for <br />RAG <br />FLITCH PLATE <br />Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />1 TYP. @ <br />)2 J CORNERS <br />r D2 H1 <br />O <br />SIM. W/ (1) <br />MSTAM36 <br />STRAPS @ <br />BASE <br />ao <br />TUB/ SHWR <br />TILE TO 7' <br />A.F.F. <br />"v 6 H 1 <br />D2 <br />O <br />-HANSON BOX <br />@ 36" A.F.F. <br />J <br />Q <br />m <br />X <br />N DRYER VENT <br />THRU SIDE <br />WALL <br />-WIRE SHELF r <br />@ +54" A.F.F. a, <br />J <br />S6 <br />TYP. <br />U.N.O. <br />3 <br />D2 <br />SIM. W/ (1) <br />MSTAM36 <br />STRAPS @ <br />BASE <br />0 <br />M <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE "C" <br />AO <br />+29.7 / -32.2 <br />© <br />+29.7 / -39.7 <br />© <br />+28.3 / -30.8 <br />OD <br />+28.3 / -37.0 <br />OE <br />+26.6 / -29.1 <br />OF <br />+26.6 / -33.5 <br />GC� <br />SEE SN SHEET HO SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />1 +2g.7 / -39.7 <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20 X 26 <br />18 J X 25 <br />S.H. <br />13 <br />20X384 <br />182'X374 <br />S.H. <br />14 <br />20 X 50 a <br />18 'X 50 <br />S.H. <br />15 <br />20X63 <br />182'X622 <br />S.H. <br />16 <br />20 X 72 <br />181 X 7121 <br />S.H. <br />1H2 <br />271/4X26 <br />26X25 <br />S.H. <br />1H3 <br />271/4X38$ <br />26x374 <br />S.H. <br />1 H4 <br />271 X 50 5 <br />26 x 50 <br />S.H. <br />1H5 <br />27 a X 63 <br />26 X 62 1/2 <br />S.H. <br />1 H6 <br />271 X 72 <br />26 X 71 112 <br />S.H. <br />22 <br />37 4 X 26 <br />36 X 25 1/2 <br />S.H. <br />23 <br />37 4 X 38 <br />3612 X 37 3/4 <br />S.H. <br />24 <br />374X50g <br />362X50 <br />S.H. <br />25 <br />37 4 X 63 <br />36 J X 62 1/2 <br />S.H. <br />26 <br />37 4 X 72 <br />36 J X 71 1/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 2'WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 2 X 251 <br />S.H. <br />33 <br />54 X 38 J <br />52 J X 37 4 <br />S.H. <br />34 <br />54 X 50 $ <br />52 z X 50 <br />S.H. <br />35 <br />54 X 63 <br />52; X 62; <br />S.H. <br />36 <br />54 X 72 <br />522' X 71 <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />Stair and Railing General Notes <br />Stairway construction shall conform to the FBC Residential 7th Edition (2020) sections R311.7, R312 <br />and R302.7. <br />Riser height: <br />The riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading <br />edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by <br />more than 3/8 inch. <br />Tread depth: <br />The tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the <br />vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The <br />greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Winders: <br />Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the <br />foremost projection of adjacent treads at the intersections with the walkline. Winder treads shall have a tread <br />depth of not less than 6 inches at any point within the clear width of the stair. <br />Nosings: <br />Nosings at treads, landings and floors of stairways shall have a radius of curvature at the nosing not greater than <br />9/16 inch or a bevel not exceeding '% inch. A nosing projection not less than 3/4 inch and not more than 11/4 <br />inches shall be provided on stairways. The greatest nosing projection shall not exceed the smallest nosing <br />projection by more than 3/8 inch within a stairway. <br />Handrails: <br />Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more <br />risers. Handrail height measured vertically from the sloped plane adjoining the tread nosing, or finish surface of <br />ramp slope, shall be not less than 34 inches and not more than 38 inches. Handrails for stairways shall be <br />continuous for the full length of the flight, from a point directly above the top riser of the flight to a point directly <br />above the lowest riser of the flight. Handrail ends shall be returned or shall terminate in newel posts or safety <br />terminals. Handrails adjacent to a wall shall have a space of not less than 11/2 inches between the wall and the <br />handrails. <br />Grip -size: <br />Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater <br />than 2 inches or provide equivalent grasp -ability in compliance with Section R311.7.8.3. <br />Guards: <br />Guards shall be provided for those portions of open -sided walking surfaces, including stairs, ramps and landings, <br />that are located more than 30 inches measured vertically to the floor or grade below at any point within 24 inches <br />horizontally to the edge of the open side. Required guards at open -sided walking surfaces, including stairs, <br />porches, balconies or landings, shall be not less than 36 inches in height as measured vertically above the <br />adjacent walking surface or the line connecting the leading edges of the treads. Required guards shall not have <br />openings from the walking surface to the required guard height that allow passage of a sphere 4 inches in <br />diameter. <br />Under -stair protection: <br />Enclosed space under stairs that is accessed by a door or access panel shall have walls, under -stair surface and <br />any soffits protected on the enclosed side with 1/2-inch gypsum board. <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic, crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />MASONRY HGT. @ 8'-8" A.F.F. <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO <br />UPLIFT CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />FIRST LIVING 728 S.F. <br />SECOND LIVING 1036 S.F. <br />TOTAL LIVING 1764 S.F. <br />LANAI 60 S.F. <br />GARAGE 379 S.F. <br />ENTRY 62 S.F. <br />TOTAL SQ. FT. 2265 S.F. <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONIC WALL R4.1 HIGH PERM <br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 R-19 KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />SECOND FLOOR PLAN-B <br />SCALE: Y4"=1'-0" <br />N �� <br />N <br />f\- ' <br />� � w <br />o� <br />o <br />mx <br />C U- a- <br />N A C <br />N t <br />NC,o� <br />Q CN <br />a► <br />o a <br />= If cc <br />L <br />cc 3 <br />tj <br />'CP o <br />� o <br />Ct <br />•, <br />c� •C <br />F L <br />. <br />f- •- 4 �l <br />lnA1%N.'ai*� <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W E y N <br />a o 8 <br />J <br />0 7 LL7 LL LL <br />�N0 v <br />M ° a <br />Q Ju- LL <br />z <br />�rn <br />X- M 0 o <br />..13Z <br />-M.,o <br />J z <br />W <br />N C , <br />LLW <br />OU ❑❑❑ <br />Z <br />' W <br />z N M <br />z � <br />z o � <br />Q� <br />� z <br />C1 <br />-1 o <br />�4-1 LL <br />cn � <br />w <br />� a <br />t0 <br />V <br />o-� w $ <br />V) c <br />�N <br />U <br />w �. <br />E <br />8 <br />off <br />u > <br />� <br />= L g� <br />U o a <br />c 8 <br />Q 0 <br />° <br />N � <br />o <br />Z <br />w <br />M <br />z <br />Z <br />LL c <br />C <br />zo <br />QZ <br />>N <br />Z¢R <br />aE <br />n O <br />Cu <br />20 <br />? <br />o E <br />�< <br />o0 <br />g, <br />Z <br />CD<Q <br />2Z <br /><=m� <br />0Z <br />�w <br />_� <br />C <br />y <br />Z, <br />Z <br />m j <br />J <br />Nm <br />aw <br />3 <br />a 0 <br />0 <br />�z <br />g o <br />W <br />U. <br />T 3 <br />21 <br /><o <br />NQ <br />r- <br />3: <br />N <br />J <br />C IF <br />M <br />tiles <br />r <br />za <br />0 <br />�O <br />0 <br />= <br />e <br />> Lo <br />� <br />0 <br />m <br />�o <br />0 <br />O <br />Cu LO <br />CN <br />LN <br />00-N <br />T �+ <br />ICY <br />IT - <br />() <br />N <br />M= <br />Lln <br />O <br />M <br />M <br />r N <br />Lf� <br />�. <br />QCO) <br />T <br />T <br />M M <br />O <br />o <br />Z <br />f6 <br />Z <br />j <br />N LO <br />E CV <br />a <br />:? <br />U -i Q p <br />� <br />JOB <br />NO: 23-06122 <br />SCALE : AS NOTED <br />SHEET NO. <br />1.2 <br />t K <br />