My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36515 Well Hill Way
Zephyrhills
>
Building Department
>
Building Plans
>
36515 Well Hill Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 10:49:03 AM
Creation date
2/27/2025 11:17:19 AM
Metadata
Fields
Template:
Building Plans
Street #
36515
Location
Well Hill Way
Contractor
Lennar Homes
Building Plans - Permit #
6512
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150A/200A INDOOR <br />PANEL CENTER <br />#14 to lights & outlets <br />NEMA 1 #12 to appliances and GFI <br />150 AMP/ <br />200 AMP 10#10toWH <br />10 #8 to Range <br />#6 to HVAC <br />MAIN <br />"� <br />O <br />150=2/0 <br />200=4f0 in 2" Conduit <br />200 amp <br />150 amp <br />UNDERGROUND <br />Disconnect <br />SERVICE BY POWER CO. <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />o <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 17, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES . Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />O <br />RECESSED LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUST FAN <br />;Q <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />�BP <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />a <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />0 <br />TELEVISION (OPTIONAL) <br />®2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />M <br />ELECTRIC METER <br />a <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />C� J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />T J <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />r _ -i <br />�I ALT I� <br />AC PAD I 1 <br />I� �I <br />I —==A <br />OPT. <br />U.C. OUTLET <br />SWITCH FOR <br />DISPOSAL <br />3 <br />W <br />KIT.) -Q <br />LL <br />N F <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS <br />SPEC 3 & 4 KITCHEN <br />SCALE: 74'=1'-0" <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS <br />------------I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />� I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />L------------------------------------J <br />RECEPT. FOR <br />ALARM SYSTEM <br />PROVIDE PHONE / CABLE <br />AND OUTLET AT TECH <br />CENTER <br />GFI @ <br />44" A.F.F. <br />pl 3" VTR 1.5" VTR <br />IIII <br />I� <br />I I <br />I I <br />I I <br />I � I <br />Kam' I I <br />� I I <br />I <br />III 3" VTR I, <br />I I <br />I I I <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />ELECTRICAL PLAN <br />SCALE: %4'=1'-0" <br />ay <br />O <br />*C2 <br />tV <br />Z <br />s o <br />ai o <br />C A C.i N <br />{A d O A <br />cc <br />ti <br />d d a' <br />D <br />E <br />C14 <br />0 <br />N <br />M <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code <br />- <br />Residential 7th Edition. Engineer's signature and seal <br />is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />a <br />E SpN <br />10 r n <br />o M8 N <br />N <br />LQ <br />O C <br />0 <br />LL- <br />4 0 <br />' 40 <br />a <br />gj M V w a a <br />LL a N Z <br />gLL _ <br />z <br />0 <br />Z <br />_ o' o <br />0 <br />N tD m C <br />W <br />��pjO' J <br />k Z <br />Z <br />O tY O w <br />) <br />M Z <br />Z <br />N U 1=- <br />06 ❑❑❑ <br />W <br />Z N M <br />z co <br />Z o a <br />d � <br />N <br />N <br />M <br />z <br />v <br />0 o <br />LJJ m <br />0 <br />Vl <br />w o <br />'2, <br />f6 <br />r— <br />U <br />L J <br />'— — E <br />° 8 <br />I <br />I <br />z� <br />U 'o <br />0 <br />° <br />c � <br />¢ Y <br />.Q <br />40 <br />o <br />CID <br />M <br />p <br />z <br />Z¢ <br />U_ <br />p <br />o <br />» <br />Zo <br />z® <br />Q <br />w� <br />t— <br />� <br />�g <br />�o <br />0� <br />Z� <br />CO rt) <br />d I— <br />� <br />z <br />�O <br />o <br />a z <br />�H <br />N to<z <br />c <br />� <br />mO <br />m CLI <br />J <br />m <br />a ° <br />aw <br />o`r <br />ZZ <br />Qo <br />W <br />co <br />m <br />0 <br />a0 <br />w <br />= F <br />oz <br />�3 <br />o <br />w� <br />�o <br />0 <br />` 0 <br />= <br />> <br />LO <br />rn <br />co <br />0 <br />O <br />= <br />Ln <br />ICU <br />m <br />Lid <br />O <br />CIO <br />N <br />C) <br />C4 <br />Ln o <br />LO <br />r <br />Q <br />LO N <br />r <br />L <br />T <br />M C` <br />o <br />E <br />j O <br />N LO <br />Z <br />E CN <br />m <br />a <br />a <br />U <br />Q 0 <br />JOB <br />NO: <br />23-06122 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3 <br />