36561 Smithfield Ln
Zephyrhills
>
Building Department
>
Building Plans
>
36561 Smithfield Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 2:51:34 PM
Creation date
2/27/2025 11:17:34 AM
Metadata
Fields
Template:
Building Plans
Street #
36561
Location
Smithfield Ln
Contractor
Lennar Homes
Building Plans - Permit #
5403
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ROOF FINISH <br />PER ELEVATION <br />ROOF SHEATHING <br />MANUFACTURED <br />ROOF TRUSS <br />MTL DRIP EDGE <br />ALUMINUM WRAP <br />ALUMINUM SOFFIT <br />NOTE: REFER TO STRUCTURAL SOFFIT <br />DETAIL SF01 SHEET SS FOR SOFFIT <br />ATTACHMENT DETAIL <br />5 ROOF O/H DETAIL <br />pia,_n <br />ELEV AT 18'-0" <br />_ <br />SECOND FLOOR CEILING <br />7/8 STUCCO <br />OVER PLYWOOD <br />CASING BEAD <br />W/ WEEPS OVER <br />FLASHING <br />12 <br />rL ELEV AT 10'-0" <br />4 <br />- <br />SECOND FLOOR FF - <br />ELEV AT 8'4" <br />FIRST FLOOR CEILING <br />6" PAINTED RAISED <br />TRIM BAND <br />6" PAINTED RAISED <br />TRIM BAND <br />rliiiiik ELEV AT 0'-0" <br />_ <br />FIRST FLOOR FF <br />FRONT ELEVATION <br />A <br />3/16" = 1'-0" <br />ELEV AT 18'-0" _ <br />SECOND FLOOR CEILING <br />ELEV AT 10'-0" <br />SECOND FLOOR FF <br />ELEV AT 8'-8" <br />FIRST FLOOR CEILING <br />ELEV F 000'-0_ <br />FIRST FLOOR FF <br />_i <br />REAR ELEVATION A <br />3/16" = 1'-0" <br />-0 <br />ROOF FINISH <br />PER ELEVATION <br />ROOF SHEATHING <br />MANUFACTURED <br />ROOF TRUSS <br />MTL DRIP EDGE <br />2X4 SUB -FASCIA <br />ALUMINUM WRAP <br />ALUMINUM SOFFIT <br />NOTE: REFER TO STRUCTURAL SOFFIT <br />DETAIL SF01 SHEET SS FOR SOFFIT <br />ATTACHMENT DETAIL <br />ROOF O/H DETAIL <br />pia - n <br />6" PAINTED RAISED <br />TRIM BAND <br />nIGARAGE DOOR TRIM DETAIL <br />11 <br />INGLE ROOF <br />12 <br />>�,,` 5 <br />Mimi <br />�I <br />4' OFF <br />RIDGE VENT <br />PAINTED RAISED <br />TRIM BAND <br />7 WINDOW TRIM DETAIL <br />3/4 - 1 -0 <br />TRIM BAND v�v <br />11TA/A" <br />WINDOW DETAIL <br />_ _n" <br />rL ELEV AT 18'-0" <br />_ <br />SECOND FLOOR CEILING <br />1'-0"o <br />O.H. <br />7 <br />A5 <br />co <br />7/8 STUCCO <br />OVER FRAME <br />ELEV AT 10'-0' <br />_rliiiiik <br />8 <br />_ <br />SECOND FLOOR FF <br />A5 <br />_ <br />12" PAINTED RAISED <br />ELEV AT 8' -8" <br />STUCCO BAND <br />FIRST FLOOR CEILING <br />DRIP "V" SCREED <br />5/8 STUCCO <br />OVER CMU <br />BORED LINES <br />PAINTED <br />RAISED <br />TRIM BAND <br />21b. EPS <br />4" _ <br />6" <br />FOAM <br />:NL <br />N <br />N <br />(.0 <br />�f <br />m <br />2 1/2" 1 1/2" <br />8 CORBE,L DETAIL <br />lra_1n <br />121NOT USED <br />4' OFF <br />RIDGE VENT <br />�0 <br />N <br />2„ <br />V-8" o <br />FLASHING <br />PAINTED RAISED <br />TRIM BAND <br />5/8" SMOOTH <br />STUCCO <br />OVER CMU <br />- <br />v41 <br /><° <br />V) <br />4) <br />NLO,;E <br />W <br />L <br />,01' <br />u <br />MN <br />N <br />V) <br />ff'' <br />V <br />N <br />-0-0- <br />N c, <br />t O <br />�rn <br />W <br />O <br />2 O <br />_ <br />.N <br />C <br />U6 <br />Q <br />}� <br />w D-N <br />V <br />C <br />r\ 0 6 <br />N <br />N <br />0 <br />N <br />N <br />Lo <br />0 <br />«w <br />LO <br />Z <br />W <br />2 <br />O <br />0 <br />W <br />z <br />TRIM BAND <br />- - �❑wQ v) �w¢~oOl <br />W p-j z0f z�W Z)Cn�W��O20JjU'JO <br />z20Q ocn2� zOLLZOw¢ <br />OZv)wwcwU <br />LI_��13f2U) Oeia-UWQ) W <br />LL OQ =O �QQ�¢ <br />w <br />13 CO,LUMN DETAIL <br />- 3/4 1 -0 <br />0 <br />O <br />z 04 <br />_OW <br />NGLE ROOF ~ <br />w U J ti <br />zW I�I a = I 7/8" STUCCO <br />N OVER FRAME <br />� I <br />C.J. C.J.C.J. C.J. C.J. <br />3'-0" 6'-4" 10'-0" 10'-8" L 10'-0" 64" <br />12 <br />—DRIP "V" WEEP <br />SCREED V5/8" STUCCO SCREED <br />OVER CMU <br />PAINTED METAL <br />- GARAGE DOOR ELEV AT 0'-0" _ _ _ _ _ _ _ _ _ _ _ _ <br />FIRST FLOOR FF <br />OCT 2 8 2022 <br />RIGHT ELEVATION A <br />3/16" = 1'-011 <br />Virtual Review Assist, Inc. <br />4'OF Plans Review completed and a o d <br />RIDGE VENT for compliance with the 2020 FBC 7th Edition <br />by Debra Anne l(lahr PX2300 <br />6 SHINGLE ROOF <br />A5 12 <br />ELEV AT 18'-0" <br />Y SECOND FLOOR CEILING <br />I I %8" <br />a W1 STUCCO <br />C,> N J 1 OVER FRAME <br />IC.J. C.J. - I C.J. C.J. 12 <br />3'-4" 8'-8" 8'-8" 8'-8" 8'-8" 3'-4" <br />Ak ELEV AT 10'-0" _ 12 _ _ _ _ _ 4 _ <br />SECOND FLOOR FF 4 —1 ! L _�- <br />ELEV AT 8'-8" WEEP %-5/8" STUCCO <br />FIRST FLOOR CEILING 2'4" SCREED <br />J '- <br />OVER CMU CASING BEAD <br />W/ WEEPS <br />OVER <br />FLASHING <br />ELEV AT 0'-0" <br />FIRST FLOOR FF <br />LEFT ELEVATION A <br />3/ 16" = 1 '-0" <br />FLASHING NOTES: <br />DUE TO CLARITY NOT ALL REQUIRED FLASHING ARE <br />INDICATED ON DRAWINGS. REFER TO FBC RES 2020 (7TH <br />EDITION), SECTION R703.4. AND R903.2 APPROVED <br />CORROSION -RESISTIVE FLASHING SHALL BE PROVIDED AT <br />ALL ROOFING SYSTEM INTERRUPTIONS, TERMINATIONS, <br />INTERSECTIONS, AND PENETRATIONS AND IN THE <br />EXTERIOR WALL ENVELOPE IN SUCH A MANNER AS TO <br />PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR <br />PENETRATION OF WATER TO THE BUILDING STRUCTURAL <br />FRAMING COMPONENTS. THE FLASHING SHALL EXTEND <br />TO THE SURFACE OF THE EXTERIOR WALL FINISH AND <br />SHALL BE INSTALLED TO PREVENT WATER FROM <br />REENTERING THE EXTERIOR WALL ENVELOPE. APPROVED <br />CORROSION -RESISTANT FLASHING SHALL BE INSTALLED <br />AT ALL OF THE FOLLOWING LOCATIONS: <br />1. AT TOP OF ALL EXTERIOR WINDOW AND DOOR <br />OPENINGS IN SUCH A MANNER AS TO BE LEAK PROOF, <br />EXCEPT THAT SELF -FLASHING WINDOWS HAVING A <br />CONTINUOUS LAP OF NOT LESS THAN 1-1/8 INCHES (28 <br />MM) OVER THE SHEATHING MATERIAL AROUND THE <br />PERIMETER OF THE OPENING, INCLUDING CORNERS, DO <br />NOT REQUIRE ADDITIONAL FLASHING; JAMB FLASHING <br />MAY ALSO BE OMITTED WHEN SPECIFICALLY APPROVED <br />BY THE BUILDING OFFICIAL. <br />2. AT THE INTERSECTION OF CHIMNEYS OR OTHER <br />MASONRY CONSTRUCTION WITH FRAME OR STUCCO <br />WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER <br />STUCCO COPINGS. <br />3. UNDER AND AT THE ENDS OF MASONRY, WOOD OR <br />METAL COPINGS AND SILLS. <br />4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD <br />TRIM. <br />5. WHERE EXTERIOR PORCHES, DECKS OR STAIRS <br />ATTACH TO A WALL OR FLOOR ASSEMBLY OF <br />WOOD -FRAME CONSTRUCTION. <br />6. AT WALL AND ROOF INTERSECTIONS. <br />7. AT BUILT-IN GUTTERS. <br />8. WHENEVER THERE IS A CHANGE IN ROOF SLOPE OR <br />DIRECTION. <br />9. AT ROOF CRICKET OR SADDLE. <br />10. AROUND ROOF OPENINGS. <br />GENERAL FLASHING NOTES: <br />INSTALL FLASHING IN ACCORDANCE WITH FBC RES 7TH <br />EDITION (2020), SECTION R703.4 AND IN ACCORDANCE <br />WITH STANDARD APPLICATIONS ILLUSTRATED IN THE <br />ARCHITECTURAL SHEET METAL MANUAL (LATEST <br />EDITION) AS PUBLISHED BY THE SHEET METAL AND AIR <br />CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION, <br />INC. <br />WINDOW NOTE: <br />ALL NEW WINDOWS MUST MEET A MINIMUM'U'-VALUE OF <br />0.4 OR LESS AND A'SHGC' OF 0.25 OR LESS. (UTILIZING <br />THE PRESCRIPTIVE METHOD FOR EXISTING STRUCTURES) <br />EGRESS NOTE: <br />EACH BEDROOM MUST HAVE ONE WINDOW THAT <br />COMPLIES WITH EGRESS CODES, IF THERE IS NO ACCESS <br />TO EXTERIOR THROUGH A DOOR. THE WINDOW MUST <br />HAVE A MAXIMUM SILL HEIGHT OF 44" ABOVE FINISH <br />FLOOR LINE OF THAT PARTICULAR ROOM <br />SHINGLE / UNDERLAYMENT NOTE: <br />ASPHALT SHINGLES ARE IN ACCORDANCE WITH TABLE <br />R905.2.6.1, FBC 7TH EDITION (2020) - RESIDENTIAL <br />SHINGLE UNDERLAYMENT SHALL COMPLY WITH SECTION <br />905.1.1, FBC 7TH EDITION (2020) - RESIDENTIAL <br />GENERAL FINISH NOTES: <br />APPLICATION OF STUCCO (EXTERIOR PLASTER) <br />MUST BE IN ACCORDANCE WITH FBC R703.7, <br />ASTM C926 AND C1063 <br />ALL LATH AND LATH ATTACHMENTS TO BE OUT OF <br />CORROSION -RESISTANT MATERIAL. (REFER TO SHEET SN1 <br />FOR THE ENGINEERED METHOD FOR LATH ATTACHMENT) <br />F5F. MO <br />Q COLO <br />z < W <br />I— <br />�WM_ <br />oo <br />Q <br />Z U <br />W <br />J O <br />O <br />A <br />O <br />N <br />N <br />N <br />N <br />N <br />Q <br />r` <br />0 <br />N <br />N <br />0 <br />N <br />N <br />0 <br />N <br />'m <br />0 <br />N <br />0 <br />O <br />0 <br />N <br />O <br />z <br />o <br />� <br />0C <br />0 <br />; <br />O <br />NLo <br />Wo0o00 <br />; <br />� <br />r <br />N <br />M <br />M� <br />w <br />Z <br />zz <br />W <br />Qw <br />O <br />W <br />Q <br />V <br />WOO <br />U U to <br />�. <br />O <br />z)z j_ <br />o�- <br />Q <br />z <br />a�a <br />�— <br />W-Jo <br />�- <br />afWQ <br />T —I <br />= <br />m w <br />N <br />~moo <br />(V <br />ZOM <br />■ ■ M <br />W <br />CL <br />�D <br />zo <br />Q <br />z <br />O <br /><WX <br />az LL <br />z <br />�z <br />OU <br />0 <br />W <br />o` <br />Z <br />z <br />z <br />z <br />w <br />W <br />J <br />0 <br />O <br />LAST PLOT DATE <br />O <br />■ . <br />July 21, 2022 <br />z 0EXTERIOR <br />ELEVATIONS A <br />