Laserfiche WebLink
SEE 3/S5 FOR <br />STANDARD <br />GABLE END <br />FRAMING <br />2X TOP PLATE TO - <br />GABLE END W/ 16d <br />NAILS @ 6" O.C. <br />2X4 STUDS @ 24" O.C.- <br />W/ SINGLE BASE & TOP <br />PLATE W/ PLYWOOD <br />SHEATHING COVERING <br />GE15 FALSE BEAM <br />SCALE: 3/4" = 1'-0" <br />rn <br />x <br />m <br />0 <br />0 <br />B <br />O <br />m <br />(n <br />N <br />O <br />J <br />L0 <br />C <br />cn <br />C, <br />a <br />CD <br />E <br />c� <br />0 <br />a <br />LZ <br />0 <br />n <br />a <br />CD <br />N <br />STRUCTURAL <br />SHEATHING 7/16" MIN. <br />NAILED W/ 8d COMMONS <br />@3"O.C.@ EDGE &6" <br />O.C. FIELD RUN FULL <br />SHEET FROM BOTTOM <br />OF FALSE BEAM <br />GABLE END <br />ENGINEERED ROOF PER ASCE 7-16 ROOF DESIGN ALLOWABLE COMPONENTS AND <br />RSH CLADDING WIND PRESSURES AND SUCTIONS FOR MEAN ROOF HEIGHT 5 25 ft <br />VIND SPEED (ULTIMATE) 140.0 MPH <br />VIND SPEED (ALLOWABLE) 108.4 MPH <br />:XPOSURE CATEGORY C <br />EFFECTIVE WIND PRESSURE AND SUCTION (PSF) <br />WIND AREA (+) VALUE DENOTES PRESSURE HIP ROOF >20 TO 45 DEG. <br />(SQ FEET) 1-1 VALUE DENOTES SUCTION [4:12]-[12:12] <br />a=4ft <br />AREA ROOF 1 2e 2n 2r 3 3e 3r <br />10 HIP -35.94 -49.57 -49.57 -49.57 t <br />GABLE -38.22 -38.22 -60.99 -60.99 60.99 1 -78.58 <br />ROOF NAILING SCHEDULE/ NAILING ZONES (SHINGLE AND TILE): <br />ZONE 1: ASTM F1667 RSRS-01 (8d) NAILS @ 6" O.C. ON EDGE AND 6" O.0 IN FIELD <br />ZONE 2e, 2n, 2r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD <br />ZONE 3, 3e, 3r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD <br />ROOF SHEATHING: <br />SHINGLE: %6" EXP. 1 (2716) or 1%2" EXP. 1 (3V16) <br />TILE: 1Y32" EXP. 1 (3V16) <br />NOTE: <br />1. PER CODE ASTM F1667 RSRS-01 REFERENCE TO 8d (2 Y8" 5x� 0.113") NAILS <br />2. WHERE THE SHEATHING THICKNESS IS GREATER THAN 1 32", SHEATHING SHALL BE FASTENED <br />WITH ASTM F1667 RSRS-03 10d (2'Y2" x 0.131") NAILS OR ASTM F1667 RSRS-04 (3" x .120") NAILS <br />3. GABLES- DROP GABLE END & (1) ADDITIONAL DROPPED TRUSS 2x4 #2 SYP OUTLOOKER <br />RAFTER W/ BLOCKING @ 16" O.C. IF NO DROPPED GABLE END, ATTACH 2x4 #2 SYP BLOCKING <br />@ 16" O.0 FIRST 4 BAYS WITH (2) 12d NAILS EA. END. ATTACH ROOF SHEATHING TO RAFTERS <br />W/ BLOCKING PER NAILING SCHEDULE. <br />3M <br />ER <br />a=4ft <br />GABLE ROOF > 20 TO 45 DEG. <br />(4:12]-[12:12] <br />UPLIFT CONNECTION CROSS-REFERENCE <br />MARK SIMPSON STRONG TIE I USP MANUFACTURING, INC. <br />Q <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />SYP <br />SPF <br />A <br />META12 <br />1420 <br />9 - 10d x 1 1/2" <br />A (2) <br />(2)META12 <br />1875 (1)PLY <br />1795 (2)PLY <br />9 - 10d x 1 1/2" <br />B <br />HETA16 <br />1810 <br />9 - 10d x 1 1/2" <br />C <br />H2.5A <br />565 <br />535 <br />10 - 8d <br />D <br />H3 <br />400 <br />320 <br />8 - 8d <br />E <br />META20 <br />1450 <br />7 - 10d x 1 1/2" <br />F <br />HHETA20 <br />2120 <br />10 - 10d x 1 1/2" <br />G <br />H 10A <br />1040 <br />1015 <br />18 -10d x 1 1/2" <br />H <br />FGTR <br />4725 <br />3400 <br />w/ (18) 1/4" x 3" SDS <br />WOOD SCREWS AND (2) <br />1/2" x 5" TITEN HD ACHOF <br />BOLTS <br />J <br />HTT5 <br />4350 <br />3740 <br />5/8" ANCH. / 26 10dxl-1/2" <br />K <br />HD3B " <br />3130 <br />3050 <br />5/8" DIA. BOLTS <br />L <br />VGT R/L <br />2225 <br />1600 <br />w/ (16) 1/4" x 3" SDS <br />WOOD SCREWS AND <br />HDU4-SDS2.5 w/ (10) 1/4" <br />X 2 1/2" SDS WOOD <br />SCREWS & (1) 5/8" ATR <br />M <br />VGT - F <br />4940 <br />3555 <br />w/ (16) 1/4' x 3"SDS <br />WOOD SCREWS AND <br />HDU4-SDS2.5 w/ (10) 1/4" <br />x 2 1/2" SDS WOOD <br />SCREWS & (1) 5/8" ATR <br />N <br />LUS26 <br />1165/1060 ** <br />1005/915 "" <br />8 - 10d x 3" <br />P <br />HUS26 <br />1320/3235 ** <br />1335/2820 ** <br />20 - 16d x 3 1/2" <br />Q <br />HUS28 <br />1760/4095 "" <br />1720/3125 ** <br />30 -16d x 3 1/2" <br />R <br />MTS12 <br />990 <br />860 <br />14 -10d x 1 1/2" <br />S <br />VGT - M <br />4940 <br />3555 <br />w/ (16) 1/4" x 3" SDS <br />WOOD SCREWS AND (1) <br />5/8" ATR EPDXIED w/ <br />SIMPSON SET w/ 12" MIN. <br />EMBEDMENT. <br />T <br />(2) LGT3 <br />6570-M 6960-F <br />4730-M 5010-F <br />w/ (24) 1/4" x 3" SDS <br />SCREWS & (8) 3/8" x 5" <br />TITEN HD (2 PLY) OR (52) <br />16D SINKERS FOR FRAME <br />U <br />MGT <br />3965 <br />3330 <br />22 -10d x (1) 5/8" ATR wl 12" <br />EMBED w/ SIMPSON "SET" <br />EPDXY <br />V <br />2 LGT2 <br />4060-M 3770-F <br />3500-M 3240-F <br />'N SINKERS <br />(14) 1/4" x 2 1/4" TITENS <br />(2 PLY) OR (28) 16D <br />SINKERS FOR FRAME <br />CONNECTOR <br />SYP <br />SPF <br />FASTENERS <br />HTA20 <br />1870 <br />1585 <br />10 -10d x 1 1/2" <br />HTA16 <br />1870 <br />1585 <br />10 - 10d x 1 1/2" <br />RT7A <br />585 <br />515 <br />10 - 8d x 1 1/2" <br />RT3 <br />345 <br />305 <br />8 - 8d x 1 1/2" <br />HTA20-18 <br />1625 <br />1400 <br />10 - 10d x 1 1/2" <br />HTTA20 <br />2375 <br />11 - 10d x 1 1/2" <br />RT16A <br />1020 <br />1160 <br />9 - 10d x 1 1/2"& 8-10d <br />RFUS <br />7100 <br />— <br />w/ (12) WS3 WOOD <br />SCREWS AND (4) 3/4" x 6" <br />WEDGE -BOLTS <br />HTT5 <br />5795 <br />5/8" ANCH. / 26 10d x1-1/2 <br />TDX2-TZ <br />3295 <br />— <br />2 - 5/8" DIA. BOLTS <br />JUS26 <br />1000/1080** <br />- <br />8 - 10d <br />HUS26 <br />2035/3400 <br />- <br />(20)16d x 3-1/2" <br />HUS28 <br />2950/5090 <br />-- <br />30d -16d x 3-1/2" <br />MTW12 <br />1195 <br />1005 <br />14-10d x 1-1/2" <br />MUGT15 <br />4175 <br />22 -10d x (1) 5/8" ATR w/ 12" <br />EMBED w/ USP CIA-7000C <br />EPDXY <br />LUGT2 <br />3100-M 4520-F <br />3100-M 3800-F <br />w/ (32) 16D SINKER & <br />(10) 1/4" x 3" WEDGE - <br />BOLTS (2-PLY) OR (32) 16 <br />SINKERS FOR FRAME <br />"X" HTS 20 1310 1245 24-10d x 1 1/2" HTW20 1530 1285 24-10d x 1 112" <br />SP1 555 1 535 10 -10d SPT22 735 8 - 10d <br />SP2 1010 1 605 12 -10d SPT24 1090 12 -10d <br />HCP2 590 1 555 1 12-10d x 1 1/2" HHCP2 1 680 1 570 1 (20)1 Od x 1-1/2" <br />* MINIMUM 3" MEMBER <br />** REACTIONS ARE FOR ROOF LOADS ONLY <br />"** DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH COULD FORCE THE PLATE OFF OF THE TRUSS. <br />ALL EPDXY ANCHORS SHALL USE SIMPSON "SET" OR USP CIA-7000C (SEE MANUFACTURES SPECS) <br />NOTE: DOUBLE FELT REQ'D ON ROOF PITCHES 3/12 & LOWER. REVISED 12-02-20 <br />LOADS - ROOF = L / 360 FLOOR = L / 480 W/ 3/8" MAX DEFLECTION. <br />FLOOR JOIST SPACING SHALL BE MAX OF 19.2" OC FOR HARDWOOD & TILE AREA'S & 24" <br />OC FOR CARPET AREA'S <br />DROP HIP DETAIL <br />2-0-0 MAXIUM SPACING ON VERTICALS OF (B) TRUSS <br />1-8-8 CLEAR GAP BETWEEN (B) TRUSSES (+/- 6") <br />'FASTEN EACH (8) TRUSS WEB TO EACH (A) TRUSS TOP CHORD @ EVERY INTERSECTING <br />POINT SHOWN ON THE HIP TRUSS SYSTEM BELOW. FASTEN TOP CHORDS OF EACH (B) <br />TRUSS TO THE TOP CHORDS OF (A) TRUSSES AT EVERY OTHER INTERSECTING POINT ("). <br />INTERSECTING POINT TO BE FASTENED WITH 2.16d COMMON NAILS OR 0.128" x 3" GUN <br />NAILS. FASTEN BOTTOM CHORD OF (8) TRUSS TO TOP CHORD OF CARRIER TRUSS WITH <br />THE SAME SPECIFIED COMMON NAILS OR GUN NAILS AT 48" OC. (+) <br />IN LIEU OF PREFABRICATED HIP PLANING TRUSSES, (B) 2x4 SO. PINE #2 OR #2 PT. STICK <br />LUMBER (LAID FLAT WISE) MAY BE USED. FOLLOW FASTENING SCHEDULE AS DEFINED <br />FOR HIP PLANING TRUSSES. Rt <br />STICK FRAMING SPLICING IS ALLOWED BETWEEN TRUSSES OR AT TRUSS 1 OF <br />INTERSECTIONS. SPLICING <br />TO BE STAGGERED BETWEEN COMMON TRUSSES, NO CATS REQUIRED UNDER STICK <br />FRAMING SPLICING. <br />MINIMUM LENGTH OF STICK FRAMING TO BE 5-0" ON A HORIZONTAL PROJECTION. <br />NOTE: SEE SHEET D1 FOR ROOF FRAMING DETAILS <br />1 (2) -12d TOENAILS EACH SIDE OF FLOOR TRUSS TO WALL OR BEAM <br />BELOW. TYP. AT INTERIOR BEARING U.N.O. <br />(A) <br />OR 2 PLY <br />;ARRIER <br />SEE SHEET D1 FOR <br />ROOF FRAMING <br />DETAILS <br />FRAMING PLAN - ELEV-B1 <br />SCALE: Y4"=1'-0" <br />coo <br />itw <br />oca <br />0 <br />� <br />d � <br />Cz W <br />_ r <br />� o <br />�� o <br />!O U N <br />- b m x <br />N N © .- <br />.y b N L <br />aa, <br />•� E � c <br />CU .P t <br />c�- <br />� <br />N d <br />w Q <br />ry J <br />-o <br />go W <br />YID <br />•••• •*- <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />a <br />A <br />v <br />N 6 C <br />ari <br />N <br />V <br />13,^ <br />Z <br />W <br />�LLLL 0 <br />u, <br />m C D ( <br />2 _ 0G <br />m w <br />ILWA�pjOf <br />Z <br />ZN <br />0 Nz d r <br />OU <br />W <br />[E]� <br />z <br />z <br />Z n <br />Q <br />d � <br />r <br />V) <br />Z <br />W N <br />•F <br />— 2 <br />Ow <br />c $ I <br />cli <br />w <br />z <br />E <br />g <br />os <br />Zo <br />Ea <br />~ C <br />o <br />� <br />z <br />M <br />3 <br />Wz <br />&Uj <br />�- <br />Jj �� <br />ra <br />8 <br />= <br />m� <br />& <br />J <br />3 <br />g� <br />gZ <br />W <br />� <br />at <br />3:�� <br />_at <br />_�� <br />°O <br />= <br />>Lo <br />LO <br />Ln <br />M <br />0 <br />.-.. <br />Q <br />� <br />H <br />N <br />Co CD <br />j <br />r <br />O <br />J <br />r <br />U) m <br />N <br />m <br />V) <br />¢I <br />0Cj <br />N <br />CD <br />O <br />Lo <br />I- <br />"- <br />U) <br />tf) <br />r <br />r <br />t <br />Z' <br />N <br />o <br />Z <br />C <br />E rcc <br />a <br />U � <br />JOB <br />NO: <br />22-08311 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />7 <br />