Laserfiche WebLink
*DIAGONAL SPACED <br />AT 15'-0" O.C. MAX <br />CONTINUOUS LATERAL <br />BRACING- NAIL OVER <br />X-BRACE AS SHOWN - <br />INSTALL BLKG. AT TRUSS <br />WEBS FOR NAILING <br />SEE ROOF <br />PLAN SHEATHING <br />�-BLOCKING <br />2X4 BLOCKING <br />BETWEEN TRUSSES <br />SECT. A -A <br />X-BRACING - 2x4 SPF OR <br />SYP w/ 2-16d @ EACH TRUSS <br />WEB <br />CROSS BRACING DETAIL (TYP.) <br />SCALE: 1/2" = V-0" <br />G.T. <br />ADD 2X4 ALONGSIDE <br />TOP CHORD WHEN REQ'D <br />TO PREVENT PLYWOOD <br />SPAN FROM EXCEEDING <br />MAX 24" SPAN (EITHER <br />SIDE OR BOTH IF REQ'D) <br />PROVIDE 2X4 MIN. BLOCKING AT <br />Q OF HIP/RIDGE, TYP.BETWEEN <br />TRUSSES W/ (2) 12D NAILS EACH <br />END TO TRUSS TOP CHORD <br />TYP. <br />3;"A TRUSS <br />SSES <br />(2) 12D NAILS —Y <br />AT 12" O.C. MAX <br />HIP/RIDGE BLOCKING DETAIL <br />TRUSS NOTES. <br />TYP. HAND FRAMING ABOVE TRUSS <br />FRAMED RIDGE 2X4 STUDS & PLATES AT <br />CON1. <br />WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TP1-2014 <br />MAY B <br />MAY NAILED EACH DIRECTION TYP. U.N.O. <br />U.N.O. <br />(TRUSS PLATE INSTITUTE) NOTE THAT THE COMBINED WIND AREA IS GREATER <br />N. <br />W/ MIN. (4) 12d WHEN <br />BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE <br />IT LANDS NEXT TO <br />INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST <br />PRE-ENG. TRUSS 2x8 BLKING. NAILED @EACH <br />COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES <br />SIDE W/ (3) 12d NAILS WHEN <br />OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD <br />REQUIRED w/ (2) SIMPSON HTS20 <br />SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & <br />W/ (14) - 10d X 1 1/2" EACH <br />SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION <br />OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED <br />ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER <br />A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. <br />o <br />•k <br />2. <br />ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS <br />LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTURER ALL LATERAL BRACING <br />SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'-0" <br />O.C. MAXIMUM. <br />3. <br />ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED W/ 2-16D <br />NAILS AT EACH TRUSS INTERSECTION. <br />CB <br />4. <br />ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS <br />DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT <br />TB41 <br />ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. <br />pg <br />B <br />5. <br />PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS <br />DEPTH EXCEEDS STANDARD HEEL HEIGHT. SEE TYP. TRUSS BLOCKING DETAILS <br />PRE-ENG. TRUSS <br />2X4 BLOCKING <br />2X4 DIAGONAL AT 8'-0" O.C. BETWEEN EA. TRUSS <br />CONT. ROOF SHEATHING AT TRUSS TOP <br />MAX & EACH END ALTERNATE <br />DIRECTION TYP. <br />A <br />CHORD AT ALL HAND FRAMED AREAS TYP. <br />WOOD TRUSS J <br />A <br />TYP. WOOD TRUSS BLOCKING DETAIL <br />SCALE: 1/2"=V-0" <br />2 x P.T. BLOCKING BY FRAMER FOR <br />PLYWOOD EDGE NAILING w/ (2) 1/4"x3" TITEN2 <br />DIAGONAL - <br />AT 8'-0" <br />MAX <br />TRUSS <br />SCALE: 1/2"=V-0" <br />HIP <br />G.T <br />VERTICAL SCAB <br />2 x 6 #2 SPF 48" O.C. <br />W/ (4) 10d TOP & <br />BOTTOM OR SIMPSON H2.5A <br />W/ (10) 8d NAILS <br />COLLAR TIE <br />EVERY 3rd <br />RAFTER <br />2X4 SPF 2 <br />(2) #7X 3-1/2" WOOD <br />SCREW EACH TRUSS <br />OR SIMPSON H2.5A @ 48" O.C. <br />BEVEL CUTS <br />(OPTIONAL) <br />„k 2x8 #2 SPF RIDGE BEAM <br />2x6 #2 SYP RAFTERS FOR SPANS 4FT <br />TO 8FT 2X4 RAFTERS FOR SPANS LESS <br />THAN 4FT @ 2'-0"O.C. MAX. w/ (3) 10d <br />COMMON TOENAILS TO RIDE BEAM <br />2X4 CONT. AT-/ CONC. MASONRY <br />T & B CHORD STEEL OR WOOD <br />BEARING SUPPORT <br />A -A ALTERNATE BLOCKING <br />DETAIL @ INTERIOR BEARING r3 <br />SCALE: 1/2" = V-0" <br />PROVIDE BLOCKING AT ALL TRUSS BEARING <br />SUPPORT WHERE TRUSS DEPTH EXCEEDS <br />STANDARD HEEL HEIGHT <br />2) SIMPSON SDWC15600 SCREWS PROVIDE 25" LAP <br />( @ SPLICE @ F.C. REBAR <br />EACH TRUSS TO LEDGER <br />1/2" GYP. WB <br />OR 3/8" PLYWOOD/ TYPE 2-M-W <br />•- • f., • • • <br />C ••- • <br />• • - • - <br />= GIs <br />— • • <br />------ <br />— ..__ <br />z <br />DOUBLE KNOCK -OUT <br />BLOCK w/ (1) #5 CONT. <br />IN EACH COURSE. <br />FLOOR CONNECTION aC� EXTERIOR WALL <br />SCALE: 3/4" = V-0" <br />2'-0" MIN. <br />LAP SPLICE <br />1'-0" 6" 6" 1'-0" 6" 6" 1'-0" <br />TYP. TYP. <br />O O 1 O SPLICE O O O <br />O O 1 O O O O <br />2'-0" SPLICE BEYOND 2'-0" <br />PART. ELEV. VIEW <br />(2) 2x8 SYP #2 P.T. CONT. <br />LEDGER w/ (2) ROWS OF 1/2" <br />TITEN HD STAGGERED @ 24" <br />O.C. W/ 5" EMBEDMENT & 6" <br />EACH SIDE OF SPLICE & <br />EACH END. <br />EDGER <br />OGETHER w/ <br />PART. PLAN VIEW (2) ROWS OF 10d @ 6" D.C. <br />LEDGER SPLICE DETAIL 54 <br />SCALE: 3/4" = V-0" <br />PROVIDE 30" LAP SPLICE <br />@ F.C. REBAR. <br />_,---(2) ROWS OF 10d NAILS @ 4" O.C. <br />FLOOR TRUSSES <br />@ 24" O.C. <br />DOUBLE KNOCK -OUT <br />BLOCK W/ (1) #5 ALTERNATE: <br />CONT. IN EACH (2)2x8 SYP #2 P.T. <br />COURSE LEDGER ATTACHED TO MASONRY W/ <br />(2)-1/2" DIA. TITEN HD MIN. 5" <br />EMBEDMENT PER 54/D1 SPACING <br />t <br />SIMPSON HGAM10 @ <br />4'-0" D.C. T & B <br />FLOOR ATTACHMENT 50 <br />SCALE: 3/4" = V-0" <br />WOOD TRUSS <br />DETAIL - ADJACENT TO TRUSSES <br />OPTIONAL 6" WIDE BOARD <br />BATTEN STRIPS TO <br />ELIMINATE 3/4" AIR SPACE. <br />SEE MANUFACT. SPECS. <br />FOR INSTALLATION. —\ <br />PRE-ENGINEERED ROOF <br />TRUSSES AT 24" O.C. MAX <br />(2) LAYERS 1"X24" PROPRIETARY TYPE <br />"X" GYP. PANELS INSERTED BETWEEN <br />2" FLOOR & CLG. RUNNERS W/ 2" <br />STEEL H STUDS BETWEEN ADJACENT <br />PAIRS OF GYP. PANELS. <br />2" FLOOR RUNNER <br />W/ 3/16" DIA. x 1 3/4" <br />TITEN2 @ 16" O.C. <br />FIRE CAULK <br />RUNNER TO BLOCK <br />WALL EACH SIDE <br />NOTES: <br />1. SEPARATION WALL IN THE <br />ROOF SYSTEM PROVIDES <br />2-HRS. PROTECTION PER <br />GA FILE ASW 0810. <br />6" WIDE 1/2" DENSARMOR PLUS FIREGUARD-C OR <br />TOUGHROCK FIREGUARD-C GYPSUM BOARD <br />MASONRY <br />SEE PLAN <br />GA FILE ASW 0810 SCALE: 3/4"=V-0" <br />M\ 47.4 Tl1CNIAILS <br />2X6 P.T. CONT. <br />LEDGER T&B W/ (2) <br />1/4" X 3" TITEN2 @ 24" <br />O.C. T&B <br />TRUSS <br />(6).,162" x 3 1/2" NAILS <br />TRUSS TO LEDGER & <br />(4) .148" x 1 1/2" <br />LEDGER DETAIL <br />SCALE: 3/4" = V-0" <br />NO MINIMUM AIR SPACE <br />W/ BATTEN STRIPS <br />1" DENSGLASS ULTRA <br />SHAFT LINER <br />2X4 BLOCKING @ 48" O.C. MAX. W/ 0 LB FELT (SHINGLES) <br />(2) 16d TOE NAILS @ EACH END FIRE RESISTANT OSB 7/16" <br />2" CLG. RUNNER FIRE CAULK SHEATHING 4' ON EA. SIDE <br />RUNNER TO SHEATHING OF WALL NOT STAGGERED CEILING BOARD <br />ABOVE AT EACH SIDES OVER PARTY WALL <br />STD 902 HOOK <br />2. MASONRY WALL PROVIDES (1) #5 VERT. IN FILL CELLS <br />2-HRS PROTECTION PER (SEE FILL CELL PLAN FOR <br />UL-U905 (see sht 9) LOCATIONS) <br />2 x P.T. BLOCKING BY FRAMER FOR <br />PLYWOOD EDGE NAILING w/ (2) 1/4"x3" TITEN2 <br />(2) SIMPSON SDWC15600 SCREWS @ EACH <br />TRUSS TO LEDGER <br />SEE 53/D1 <br />3/4" PLYWOOD DECKING GLUED AND <br />NAILED W/ 8d COMMON AT 6" O.C. <br />EDGES AND 12" O.C. FIELD <br />1/2" GYP. WB. OR 3/8" PLYWOOD/TYP 2-M-W <br />OSB (DRAFTSTOPPING) TO BE NAILED W/ <br />8d COMMON AT 6" O.C. TO ONE SIDE OF TOP CH I <br />FLOOR TRUSS FOR AN AREA < 1000 S.F. 00 TO <br />AND SEALED PENETRATION AREAS W/ <br />FOAM. DRAFTSTOPPING SHALL DIVIDE <br />THE CONCEALED SPACE INTO APPROX. <br />EQUALAREAS <br />(1) LAYER 1/2" HIGH STRENGTH OR 5/8" GYP. <br />(OR 5/8" GYP. TYPE "X' @GARAGE W/ A <br />HABITABLE ROOM ABOVE) W/ 1 3/8" <br />DRYWALL NAILS OR DRYWALL SCREWS 7" <br />O.C. CEILING, 8" O.C. WALLS & 4" O.C. <br />EDGES <br />(1) #5 VERT. IN FILL CELLS (SEE <br />FOUNDATION PLAN FOR LOCATIONS) <br />8" CONC. BLOCK (TYP.) PER UL905 — <br />1x P.T. BASE NAILER—-,, <br />6X6 W1.4xW1.4 WWF. <br />w <br />U <br />J <br />a <br />MASONRY WA <br />SEE FLOi <br />PLAN FOR MO <br />INI <br />STRUCTURAL SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />VARIES W/ <br />ROOF SLOPE <br />IN. 2X4 #2 SPF P.T. <br />ONT. W/ (2) a"x3" <br />ITEN2 SCREWS @ <br />i" O.C. <br />TRUSS OR <br />ROOF SYSTEM <br />SHEAR TRANSFER <br />EXTERIOR. WALL r52N� <br />SCALE: 3/4" = 1'-0" <br />PROVIDE 2x BLOCKING W/ (2) 12d NAILS EA. END BETWEEN <br />TRUSSES 4'-0" FROM SEPARATION WALL. SOLID BLOCKING <br />12 BETWEEN TRUSSES TO BOTTOM SIDE OF PLYWOOD. BLOCK <br />SEE MUST BE "PITCH CUT" (SEE ELEVATIONS) TO PROVIDE AS <br />ELEV. MUCH CONTACT AS POSSIBLE TO UNDER SIDE OF ROOF <br />DECK. ALL JOINTS AROUND BLOCKING MUST BE CAULKED <br />WITH APPROVED FIRE CAULKING. <br />2x4 LEDGER @ 48" O.C. <br />SEE ROOF PLAN <br />MAX VERTICALLY NAILED <br />FOR STRAP INFO. <br />TO TRUSS WEBS W/ (2) 8d <br />BASE BOARD PER SPECS. <br />(TYP.) <br />EXTEND BURN CLIPS AS PER <br />2 x P.T. BLOCKING BY FRAMER <br />FIRE WALL MFG. <br />FOR PLYWOOD EDGE NAILING <br />R30 INSUL. MIN. <br />SPECIFICATIONS NAILED INTO <br />W/ (2) 1/4"x3" TITEN2 <br />2X4 LEDGER ONLY AT EACH <br />SIDE OF STEEL "H" STUD. <br />(2) SIMPSON SDWC15600 <br />(1) LAYER 1/2" HIGH STRENGTH <br />SCREWS @ EACH TRUSS TO <br />OR 5/8" GYP. WB. W/ 1 3/8" <br />LEDGER <br />DRYWALL NAILS OR DRYWALL <br />'\',\—SIMPSON <br />SCREWS 7" O.C. EDGES. <br />RBC @ 36" O.C. W/(6) 10d X 1 1/2" NAILS <br />3/4" FLOOR <br />INTO TRUSS BOTTOM CHORD/SCAB & (3)1/4" X 2-3/4" <br />SHEATHING <br />TITEN SCREWS INTO MASONRY. NOTE: RBC CLIPS <br />TO BE INSTALLED PRIOR TO FURRING STRIPS <br />INSTALLATION (TYP. ON BOTH FACES OF WALL) <br />1x P.T. NAILER INSTALLED <br />AFTER INSTALLING RBC'S <br />1/2" GYP. WB OR 3/8" <br />8"x8"x16" CONC. KNOCKOUT <br />PLYWOOD/ <br />BLK. W/ 1 #5 ROD CONT. <br />TYPE 2-M-W OSB <br />FILLED W/ GROUT <br />(DRAFTSTOPPING) <br />4"x4" INSPECTION PORT AT <br />—EACH <br />0 BE NAILED W/8d <br />FILLED CELL (TYP.) <br />COMMON @ 6" O/C TO <br />i--1x P.T. BASE NAILER <br />ONE SIDE OF THE <br />—STD. 90° HOOK <br />FLOOR TRUSS FOR AN <br />(SEE DETAIL) <br />AREA 5 1000 SQ. FT. OF <br />NAIL FLOOR TRUSS TO LEDGER W! <br />FLOOR AREA &SEALED <br />(4) 10d TOENAILS (TYP.) EA. SIDE <br />PENETRATION AREA W/ <br />FOAM. DRAFTSTOPPING <br />----. <br />SHALL DIVIDE THE <br />(2) SIMPSON SDWC15600 SCREWS @ <br />CONCEALED SPACE INTO <br />EACH TRUSS TO LEDGER <br />APPROX. EQUAL AREAS. <br />TOI? iSFiORD B <br />DOUBLE KNOCKOUT BLOCK W/ (1) #5 ROD <br />CONT. IN EA. COURSE FILLED W/ GROUT <br />1" P.T. NAILER <br />R-3 MIN. INSUL. PER. FBC. <br />1/2" GYP. WB. <br />TYP. "S" MORTAR (TYP.) <br />Z J <br />�a <br />U) <br />N d <br />:5,4"x4" INSPECTION PORT. AT <br />EACH FILLED CELL (TYP.) <br />LA II o <br />(4) #5 CONT. STD. 909 HOOK <br />ON 3" CHAIR 8" 2'-0" 8" (SEE DETAIL) <br />2-STORY PARTY WALL SECTION <br />SCALE: 3/4"=V-0" <br />PRE-ENGINEERED <br />FLOOR TRUSS' AT <br />24" O.C. <br />GYP. BOARD CLG. <br />SEE 53/D1 FOR <br />LEDGER CONNECTIONS <br />1/2" GYP. BD. <br />(2)-1 X 4 P.T. <br />NAILER <br />BASE BOAR[ <br />PER SPECS. <br />CONC. SLAB <br />SEE FOUND, <br />6 MIL VISQUI <br />TREATED! <br />SEE PLAN <br />TOP OF PLATE <br />TOP COURSE W/ <br />LINTEL SEE <br />70. PLAN <br />SEE PLAN <br />TuFoirwINDOW <br />WINDOW PER PLAN <br />4 <br />8" C.M.U. WALL <br />10'-8" <br />DOUBLE KNOCK -OUT <br />W/ (1) #5 CONT. IN. <br />EACH COURSE <br />. z <br />REINFORCING W/ MATCHING <br />#5 DOWELS IN SOLID <br />GROUTED CELL W/ MIN. 25" <br />LAP SPLICE MIN. <br />8" C.M.U. WALL <br />JP OF SLAB <br />50 <br />CV <br />r <br />3 #5 CONT. 200' <br />TYP. 2 STORY WALL SECTION <br />SCALE: 3/4" = V-0" <br />REV. 08.20.21 <br />F.F. <br />VARIES WITH <br />SITE GRADES <br />SEE PLAN <br />O 0 <br />N �mX <br />MU_CL <br />Z � C <br />�,. <br />(D <br />_f r._ <br />v <br />N-d <br />:mod=�/��` <br />v� A` <br />n? <br />N W I LJ Q <br />- O O <br />U .= <br />-o <br />t�a ,` <br />0 W <br />>irl-+— <br />N <br />0 <br />N <br />N <br />✓ N <br />No F 3750 <br />. <br />........ A <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />S <br />W #onoE na 0 -8N <br />N 6C LL <br />(0 C W N# W <br />7�; <br />N (0nn'o U- W a <br />a Y <br />Q ysv <br />a 0 <br />0 JELL <br />0 <br />-��, <br />a <br />r�a i o �o <br />5 6 04 O <br />WN�pjO' a ¢ a <br />'1 N M Z W to O <br />LL a <br />Z p V U y <br />W aao <br />� T <br />z <br />z <br />(n N <br />N z <br />v 0 o <br />4 N LL <br />� <br />U � <br />0 w g <br />�Ly N V)ru <br />� co <br />U � <br />LLr <br />' J <br />r <br />r 8 <br />�Q <br />N <br />sr <br />o <br />CjD <br />w <br />Mz <br />yJ <br />11- <br />E <br />zo <br />o <br />s� <br />< s <br />30 <br />91O <br />U <br />t— rd <br />w 2 <br />0 <br /><O <br />R c"i <br />O G <br />W ¢ <br />j 0 <br />o <br />0d <br />az <br />N � <br />� IT <br />ao <br />ado <br />aw <br />m0 <br />� C <br />� <br />oz <br />Z, <br />z <br />N N <br />m <br />W <br />N �aZ <br />a <br />811 <br />w <br />ZqQ o <br />U <br />J Z <br />�w <br />W <br />3� <br />Jz <br />E; <br />o <br />c0 <br />wa <br />Im <br />>_ <br />c°�3 <br />o r <br />In <br />ai <br />N <br />0 <br />cfl <br />CV <br />r <br />c_6 <br />lln <br />O <br />W <br />L6 <br />IM <br />o <br />CN <br />Nco <br />00 <br />_T_O <br />o <br />1 N <br />J �n <br />T <br />0 <br />N r <br />0 <br />m <br />O w <br />Z <br />Z <br />E O <br />E <br />M <br />a <br />Li _j ¢ o <br />JOB <br />NO: 21-17091-17908 <br />SCALE: AS NOTED <br />SHEET NO. <br />D1 <br />