Laserfiche WebLink
DOOR JAMB (REFER 1x4 1/2" DRYWALL <br />DOOR JAMB (REFER <br />1x4 1/2" DRYWALL <br />DOOR JAMB (REFER <br />1x4 1/2" DRYWALL <br />TO PRODUCT <br />P.T. <br />TO PRODUCT <br />TO PRODUCT <br />APPROVAL FOR CONN. <br />APPROVAL FOR CONN. <br />1x4 P.T. <br />APPROVAL FOR CONN. <br />1x4 <br />''. 1 X 4 <br />FURRING <br />3-1/4" LONG X 3/16" 0 <br />FURRING <br />3/16" 0 X 3" LONG <br />TAPCONS <br />FURRING <br />(2) ROWS 3/16" x 3-1/2" <br />TAPCON. INTO <br />STAGGERED @ 16 " <br />TAPCON @ 16" O.C. & 4" <br />ElX8 <br />2X8 <br />BLOCK@ SPACING „ <br />1 <br />DETAIL <br />O.C. 2-ROWS INTO <br />1x8 P.T. <br />FROM EACH END w/ MIN. <br />2" EDGE DIST. ATTACH <br />PER MANUFACTURE <br />MASONRY THROUGH 1-1 /2" DETAIL <br />1x8 w/ (2) ROWS 8d NALS <br />�� <br />3 DETAIL <br />1x4 P.T. & 1x8 P.T. <br />STAGGERED @ 12" O.C. <br />3/16" x 3 -1/2" <br />1x4 P.T. <br />DOOR JAMB (REFER <br />TAPCON @ 16" <br />TO PRODUCT <br />O.C. & 4" FROM <br />DOOR JAMB (REFER <br />APPROVAL FOR CONN. <br />1x4 <br />1/2" DRYWALL <br />DOOR JAMB (REFER <br />EACH END W/ MIN,TO <br />PRODUCT <br />TO PRODUCT <br />2" EDGE DIST. <br />APPROVAL FOR CONN. <br />2x8 P.T. w/ (2) ROWS 3/16" <br />APPROVAL FOR CONN. <br />(2) ROWS 3/16" x 3-1/2" <br />x 3-1/2" TAPCON @ H <br />O.C. & 4" FROM EACH <br />1x4 <br />TAPCON @ 16" O.C. & <br />END w/ MIN. 2" EDGE DIST. <br />FURRIN( <br />4" FROM EACH END w/ <br />2x8 P.T. <br />ATTACH SECOND PLY w/ <br />2x P.T. AS REQ'D <br />MIN. 2" EDGE DIST. <br />(2) ROWS 10dx3" <br />2x8 <br />2X I7FTQII- <br />2 1 /4�� <br />I7FTAII <br />STAGGERED @ 12" O.C. <br />3-1/4" DETAIL <br />BUILDOUT @ OVER SIZE DOOR -WINDOW ROUGH OPENINGS CC <br />SCALE: N.T.S. SS <br />2x8 P.T. BUCK -CONNECT TO BLOCK <br />W/ 1/4" x 31/4" TAPCON (1 1/4" MIN. <br />EMBEDMENT INTO BLK.) <br />1 X 4 FURRING <br />BLOCK HEADER <br />1/2" DRYWALL <br />8d NAILS AT 8" O.C. AT BUCK <br />2 x 8 45^ DIAGONAL (4)10d NAILS INTO \ - <br />BRACE(S) 2 x 8 BRACE/BLKG. <br />7/16" OSB <br />BUILT UP PLWD. BUCK ARCH PANEL CUT HOLE IN O.S.B. FOR <br />SCRIBE (NOTCH) POLY -CELL IN THIS AREA <br />BACKSIDE TO FIT ARCH (4)10d NAILS INTO 2 x 8 <br />CONNECT W/ 8d NAILS BRACE/ BLKG. <br />INSTALL WDW. SCREW ANCHO 2 x 4 SOLID BLKG. (FULL WIDTH OF WALL) BTWN. OSB <br />INTO ARCH BLKG. PER ARCH FACES W (4)10d NAILS THRU OSB INTO 2 x 8 <br />INSTALLATION DETAILS A -A PROVIDE TAPCON PER WDW. INSTALLATION DETAILS OR THRU --� <br />-� 1-1/2" THK. OR MORE BUCK WITHIN 6" MIN. OF START OF ARCH <br />ARCH DETAIL J <br />SCALE: N.T.S. SS <br />BLOCK HEADER <br />1 X 4 FURRING <br />8d NAILS @ 8" O.C. AT BUCK <br />PROVIDE 2 x 8 DIAG. BRACE BT <br />VERT. BRACES WHEN HGT. OF <br />BRACE EXCEEDS 24" <br />2 x 8 VERT. BRACE(S) <br />BUILT UP PLWD. BUCK - — <br />SCRIBE (NOTCH) BACKSIDE <br />TO FIT ARCH CONNECT W/ <br />8d NAILS <br />INSTALL WDW, SCREW---' <br />ANCHOR INTO ARCH BLKG. <br />PER INSTALLATION DETAILS <br />1/4" MAX <br />it <br />SOLID BLKG. AT TOP BTWN. <br />ARCH BLKG. & BUCK <br />2 x 8 BUCK - CONNECT TO BLOCK <br />2'-0" <br />WITH 1/4" x 31/4" TAPCON (1 1/4" MIN. <br />/4" MAX EMBEDMENT INTO K.) <br />4/1 2'-0" <br />SOLID BLKG. AT TOP BTWN. ARCH <br />BLKG. & BUCK <br />2 x 8 VERT. W/ (2)10d <br />NAILS AT EA. END <br />LEAVE A CUT OUT IN O.S.B. ON T <br />INSIDE TO ALLOW FOR INSULATION <br />TO BE INSTALLED <br />7/16" OSB ARCH PANEL <br />2 x 4 SOLID BLKG. (FULL WIDTH OF WALLS) EQUAL <br />BTWN. OSB ARCH FACES W/ (4)10d NAILS <br />THRU OSB INTO 2 x 8 <br />B_B ARCH DETAIL rK <br />SCALE: N.T.S. SS <br />SECTION <br />A -A <br />8" <br />1/4" x 31/4" TAPCONS <br />-LEAVE A CUT OUT IN O.S.B. ON THE <br />INSIDE TO ALLOW FOR INSULATION <br />TO BE INSTALLED <br />-2 x 8 45 DIAGONAL BRACE AT EA. <br />FACE OF ARCH W/ (3)10d NAILS <br />AT EA. END <br />\_ <br />PROVIDE TAPCON WITHIN <br />4" MIN. OF BRACE <br />START OF ARC <br />4' MAX. RAD. <br />SECTION <br />B-B <br />8" <br />EQUAL <br />PROVIDE 2x <br />PROVIDE (2) MIN. CONT. W/ (3) <br />TAPCON AT EA. SIDE 12d NAILS <br />BUCK - (1) WITHIN 4" <br />MIN. OF START OF <br />ARCH <br />START OF ARC <br />PROPER INSTALLATION MAx.B <br />FILL SOLID <br />BOTH CELLSF <br />#5 REBr <br />(TYPE) <br />STD. 90' <br />HOOK (1 <br />.7 <br />+5^ <br />NOTCH WEB AT <br />FIRST 2 COURSI <br />CAPACITY = 805 # FOR 1 STRAP <br />=1610 # FOR 2 STRAPS <br />1 PLY PRE-ENGINEERED TRUSS <br />SIMPSON HM9KT w/ (4)1/4"x1 1/2" SDS <br />SCREWS & (5)1/4" x 2114" TITEN (IF TRUSS <br />IS 2 PLY INSTALL SIMPSON LGT2 w/ (16)16d <br />SINKERS AND (7)1/4"x21/4" TITEN = 2150 #) <br />BOND BEAM OR CAST IN PLACE BEAM <br />RETROFIT TRUSS DETAIL <br />N.T.S. <br />2X6 SYP #2 CONT. (MATCH TRUSS DEPTH <br />IF TRUSSES USED) W/ (3) #6 X 4%" WOOD <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY WALL <br />USE (1) SIMPSON 1/2" HD TITEN (CENTERED) w/ <br />MIN. 4" EMBEDMENT AT 16" O.C. <br />12 <br />JACK TRUSS PROVIDED BY SEE <br />TRUSS COMPANY OR PLAN <br />2x6 #2 SYP @ 24" O.C. <br />ROOF SHEATHING ATTACHED <br />PER NAILING SCHEDULE <br />ALL <br />(5)12d NAILS <br />SIMPSON <br />2X6 TO 2X4 <br />H2.5A w/ (10) <br />8d NAILS <br />NOTE: <br />SHED ROOF ENDS TO BE <br />GABLE ONLY, CORNERS <br />SHALL NOT BE FRAMED AS <br />HIP. <br />DESIGNED ONLY FOR THE <br />INSTALLATION OF SHINGLE <br />AND METAL ROOF FINISH <br />I <br />GLASS BLOCK INSTALLATION NOTES <br />A) <br />COVER SILL AREA WITH A HEAVY COAT OF ASPHALT EMULSION. ALLOW EMULSION TO DRY <br />AT LEAST 2 HOURS BEFORE PLACING MORTAR. <br />B) <br />ADHERE EXPANSION STRIPS TO JAMBS AND HEAD. MAKE CERTAIN EXPANSION STRIP <br />EXTENDS TO SILL. <br />C) <br />SET A FULL MORTAR BED JOINT, APPLIED TO SILL. <br />D) <br />SET LOWER COURSE OF BLOCK. MAINTAIN A UNIFORM JOINT WIDTH OF 3/8" PLUS OR MINUS <br />1/8". ALL MORTAR JOINTS MUST BE FULL AND NOT FURROWED. ALL MORTAR SHALL BE <br />TYPE "S" OR "N". STEEL TOOLS MUST NOT BE USED TO TAP BLOCKS INTO POSITION. (PLACE <br />EXPANSION STRIP <br />A RUBBER CRUTCH TIP ON END OF TROWEL TO TAP BLOCK INTO POSITION.) DO NOT <br />20 ga. PANEL <br />REALIGN, TAP, OR OTHERWISE MOVE BLOCK AFTER INITIAL PLACEMENT. FOR SOLID GLASS <br />BLOCK IT MAY BE NECESSARY TO USE WEDGES IN THE MORTAR JOINTS OF THE LOWER <br />ANCHOR <br />COURSES TO PREVENT THE MORTAR FROM BEING "SQUEEZED" OUT. <br />1/4" EXPANSION BOLT (2 <br />E) <br />INSTALL PANEL REINFORCING IN EVERY OTHER MORTAR BED HORIZONTALLY AND IN JOINTS <br />9 ga. PANEL <br />PER ANCHOR) <br />IMMEDIATELY ABOVE AND BELOW ALL OPENINGS WITHIN PANELS. (THE SAME SPACING <br />REINFORCING <br />SHALL APPLY TO PANEL ANCHORS WHEN USED AT JAMBS AND HEADS IN LIEU OF CHANNEL <br />(EVERY OTHER <br />OR CHASE SURROUNDS.) RUN REINFORCING CONTINUOUSLY FROM END TO END OF PANELS. <br />COURSE) <br />EXPANSION STRIP <br />LAP REINFORCING NOT LESS THAN 6 INCHES WHENEVER IT IS NECESSARY TO USE MORE <br />THAN ONE LENGTH. DO NOT BRIDGE EXPANSION JOINTS WITH REINFORCING. INSTALL <br />REINFORCING AS FOLLOWS: <br />* PLACE LOWER HALF OF MORTAR IN BED JOINT. DO NOT FURROW. <br />` -:: <br />SEALANT <br />* PRESS PANEL REINFORCING INTO PLACE. <br />,.' <br />6„ MIN. LAP SPLICE W/ <br />COVER PANEL REINFORCING WITH UPPER HALF OF MORTAR BED AND TROWEL <br />.: <br />. <br />REINFORCING PANEL <br />SMOOTH. DO NO FURROW. <br />F) <br />PLACE FULL MORTAR BED FOR JOINTS NOT REQUIRING PANEL REINFORCING - DO NOT <br />FURROW. MAINTAIN UNIFORM JOINT WIDTH. <br />6" MIN. LAP <br />G) <br />SET SUCCEEDING COURSE OF BLOCKS. SPACE AT HEAD OF PANEL AND JAMBS MUST <br />SPLICE <br />REMAIN FREE OF MORTAR. <br />NOTE: <br />H) <br />STRIKE JOINTS SMOOTH WHILE MORTAR IS STILL PLASTIC AND BEFORE FINAL SET. AT THIS <br />SEE GLASS BLOCK INSTALLATION NOTES. <br />TIME RAKE OUT ALL SPACES REQUIRING SEALANT TO A DEPTH EQUAL TO THE WIDTH OF THE <br />SEALANT <br />SPACES. REMOVE SURPLUS MORTAR FROM FACES OF GLASS BLOCKS AND WIPE DRY. <br />GLASS BLOCK DETAIL <br />TOOL JOINTS SMOOTH AND CONCAVE, BEFORE MORTAR TAKES FINAL SET. (REMOVE <br />WEDGES FROM LOWER COURSES OF SOLID BLOCKS AND POINT THE VOIDS WITH MORTAR.) <br />GLASS BLOCK SHALL BE INSTALLED PER THE FLORIDA BUILDING CODE RESIDENTIAL SECTION R160 <br />1) <br />AFTER FINAL MORTAR SET (APPROX. 24 HOURS), INSTALL PACKING TIGHTLY BETWEEN <br />GLASS BLOCK PANEL AND JAMB AND HEAD CONSTRUCTION. LEAVE SPACE FOR SEALING. <br />J) <br />APPLY SEALANT EVENLY TO THE FULL DEPTH OF RECESSES IN ACCORDANCE WITH THE <br />MANUFACTURER'S APPLICATION MANUAL AND INSTRUCTIONS. <br />K) <br />A MAXIMUM OF 60 SQUARE FEET OF GLASS BLOCK MAYBE INSTALLED IN ANY OPENING. <br />FOR WIND SPEEDS UP TO 110 MPH*, PER PITTSBURG CORNING RECOMMENDATIONS FOR <br />INSTALLATION OF GLASS BLOCK. <br />JACK TRUSS PROVIDED BYE <br />TRUSS COMPANY OR 2X4 <br />#2 SYP @ 24" O.C. <br />4'- MAX SEE PLAN <br />2X4 SYP #2 CONT. (MATCH TRUSS DEPTH —� <br />IF TRUSSES USED) W/ (2) #6 X 4%" WOOD <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY <br />WALL USE (2)1/4" X 31 /2" TAPCONS AT 16" <br />O.C. <br />SECTION @ ENTRY rL_"� <br />SCALE: 3/4" = V-0" SS <br />#5 CONT. TOP & MID <br />" <br />MASONRY WALL. SEE PLAN FOR <br />REINFORCING. PROVIDE LOWER <br />HOOKED DOWEL <br />W.W.M. AT PERIMETER <br />WHERE THIS CONDITION <br />OCCURS <br />WITH MIN. 3 COVER 6'-0" <br />t+ � <br />P- <br />GRADE <br />- e <br />C14 k <br />z <br />e <br />(2) #5 REBAR. (1-STORY) <br />16" MIN. (1-STORY) (3) #5 REBAR. (2-STORY) <br />20" MIN. (2-STORY) WITH MIN. 3" COVER EA. WAY <br />100 .1 <br />SECTION AT DEEP MONO FOUNDATION <br />REV. 07.28.21 SCALE: 3/4" = V-0" <br />FILLED CELL PER <br />FOUNDATION PLAN <br />kR <br />YP.) <br />THE <br />:S <br />UNACCEPTABLE INSTALLTION <br />DO NOT DO THIS <br />♦0 <br />♦0 <br />#5 REBAR (TYP,) ♦♦♦♦ <br />1♦ <br />1♦ <br />TD. 90° HOOK (TYP.) <br />1♦ <br />1♦ <br />B @ FIRST COURSE <br />2"x BOT. PLATE W/ (2) 10d @ 6" O.C. <br />3/4" PLYWOOD DECKING GLUED - <br />AND NAILED W/ 8d COMMON @ <br />6" O.C. EDGES AND 12" O.C. FIELD <br />ATTACHED WALL SHEATHING TO <br />2X BOTTOM PLATE W/ 8d @ 4" <br />O.C., 2 ROWS STAGGERED <br />(--2x BAND JOIST W/ FACE NAIL 10d <br />@ TOP & BTTM CHORD, AND (8) <br />FACE NAILS 10d @ TRUSS VERT. <br />WEB <br />METAL SEAT PLATE <br />NOTE: <br />LAP SHEATHING TO <br />BOTTOM OF BAND <br />JOIST TYPICAL <br />- SIMPSON HGAM10KTA @ 12" O.C. <br />w/ (4)1/4xl 1/2" SDS SCREWS <br />INTO BAND JOIST & (4)1/4"x2 3/4" <br />TITEN INTO K.O. BLOCK <br />FILLED CELL INSTALLATION H RETROFIT FOR MISSING EMBEDDED STRAP <br />SCALE: N.T.S. <br />SS SEE TYP. 2-STORY WALL SECTION FOR ADDL. INFO SCALE: N.T.S. <br />SEE ARCH PLAN AND <br />PRE-ENG TRUSS DESIGN <br />SEE NOTE 1 BELOW <br />rl2x SUB FASCIA <br />ALUM DRIP EDGE <br />BRG WALL TYPE T- j ALUM FASCIA <br />PER PLAN 1 I 1-3/4" TRIM PAINTED <br />I I SS NAIL w/ 5/16" HEAD <br />F CHANNEL, <br />FASTENED PER I DIA. @ 24" O.C. <br />NOTE 2 BELOW--L CONT VENTED OR SOLID SOFFIT <br />CONT 2X4 NAILED TO 2x BLOCKING NAILED TO TOP <br />BLOCKING w/ 2-12d NAILS {**) CHORD EVERY OTHER TRUSS <br />W/ 3-12d NAILS, TYP. (**) <br />1. G.C./ BUILDER TO VERIFY/PROVIDE SOFFIT MATERIAL SPAN CAPACITIES BASED <br />ON THE DESIGN PRESSURES SPECIFIED FOR COMPONENTS AND CLADDING <br />LISTED IN THE DESIGN CRITERIA ON SHEET SN. <br />2. FOR SOFFIT ATTACHMENT AT WALL (PER ALPHA ALUM. INC. FL# 165" R5 FL <br />PRODUCT APPROVAL) F CHANNEL FASTENED TO: <br />CMU w/ T NAIL .097" DIA. @ 24" O.C. w/ 5/8" MIN. EMBEDMENT <br />WOOD w/ (3) 16 GA. 3/4"xl/4" CROWN STAPLES @ 24" MAX. O.C. IN DIAMOND <br />PATTERN <br />SUB FASCIA w/ 16 GA. 3/4"xl/4" CROWN STAPLE @ EACH GROOVE -- <br />STRUCTURAL SOFFIT <br />SF01 SCALE: 3/4" = V-0" (**) FOR ALUMINUM SOFFITS WITH SPANS <br />REV. 09.23.2021 > V-4", INSTALL MID SPAN BLOCKING PER <br />THE SOFFIT FL PA INSTALLATION CRITERIA <br />*REFER TO THE PRODUCT APPROVAL FOR INSTALLATION DETAILS.* <br />+ <br />?x <br />+ <br />\ + <br />TRUSS <br />2X4 SYP — <br />EACH TRUSS <br />CONNECTOR <br />SEE LINTEL- <br />SCHED. <br />2 X 4 #2 SYP SCAB TO SIDE OF <br />TRUSS AS SHOWN FOR O.H. UP TO Z-6" <br />9 * DOUBLE 2X4 SCAB FOR 2'-6" TO 4'-0" O.H. <br />�F/VGTN (2)10d NAILS @ 8" O.C. <br />TO TRUSS TOP CHORD <br />+ PLYWOOD SHEATHING <br />+ + <br />+ <br />BLOCKING AS <br />+ REQUIRED TO <br />+ + <br />+ SUPPORT SOFFIT <br />CENTER SOFFIT <br />PRECAST LINTEL <br />SEE ELEVATION <br />FOR OVER HANG <br />(MAX. 4'-0") <br />SECTION @ ROOF EXTENSION M <br />SCALE: 3/4" = V-0" SS <br />SIMPSON HTT4 w/ (18)1Od x 1 <br />1/2" NAILS TO STUDS & (1) - <br />5/8" DIA. ALL THREAD ROD <br />EPDXIED w/ SIMPSON "SET" <br />EPDXY MIN. 6" EMBEDMENT 8 <br />3" MIN. EDGE DISTANCE <br />RETROFIT FOR MIS <br />MSTAM STRAP <br />SCALE: 3,-. - r <br />CFF CNFFT m amn <br />FILL 1st 4 COURSES <br />SOLID W/GROUT <br />FOR OVERHANGS BETWEEN OVER 1 1/2" <br />CONTACT ENGINEER OF RECORD FOR <br />FURTHER INSTRUCTIONS. <br />OVERHAN <br />RETROFIT WALL OVERHANG DETAIL (NTS) <br />FOR OVERHANGS BETWEEN 3/4" TO 1 1/2" <br />NOTE: FOR OVERHANGS LESS THAN 3/4" - NO REPAIR REQ'D. <br />1 r-0rr 5'-011 <br />INISH <br />.,& <br />' <br />• . <br />e '11 ► #5 BAR <br />p p• `, . • CENTERED W/ g <br />e . • ry s H IN TOP o <br />• d : KNOCKOUT / N <br />° CHAIR BLOCK <br />MONO FOOTING -_ ,, b ,• <br />SIZE AND REINF. PER PLAN - - '• <br />AND SECTION DETAILS <br />r+ e <br />CLEAN FILL ! A. <br />DIRT • 6 Z <br />' STANDARD q <br />90' HOOK iv <br />#5 BAR IN <br />FILLED CELL <br />�s <br />YK <br />STEMWALL FOOTING SIZE AND <br />MONO TO STEMWALL FOOTING REINF. AND STEMWALL <br />SECTIONN DDETAETAILS <br />SCALE: 3/4" = V-0" <br />OTE: IF RETROFIT FILLED CELL CONDITIONS EXCEED (3) PER PROJEC' <br />ONTACT ENGINEER OF RECORD FOR ADDITIONAL INSTRUCTION. <br />EXISTING BOND BEAM. <br />DRILL 3/4"x5" MIN. HOLE SET BAR IN <br />EPDXY CAP TO PREVENT LEAKAGE <br />TOP SPACE BETWEEN EXISTING GROUT & NEW GROUT <br />MUST BE PACKED WITH NON -SHRINK GROUT (USUALLY ± 2") <br />#5x6' EMBEDDED INTO EXISTING BOND BEAM <br />FILL CELL FULL HEIGHT W/ <br />NON SHRINK GROUT. <br />#5x6' EMBEDDED INTO <br />EXISTING FOOTING <br />DRILL 3/4"x5" MIN. HOLE <br />SET BAR IN EPDXY <br />I I- EXISTING FOOTING <br />RETROFIT FILLED CELL DETAIL <br />4" SAW CUT <br />A SECTION <br />1 SCALE: N.T.S. <br />SCALE: N.T.S. <br />. <br />i ~ <br />N <br />Qm N <br />.-- <br />Ix <br />M U_ <br />f3_ <br />�- <br />-0 O <br />N C <br />U <br />to <br />. <i <br />Q <br />> c: <br />r <br />L - : j <br />0 0 O <br />C <br />i 0 ;_, <br />=-6 ` -Q <br />> 2 0 W <br />N <br />N <br />O <br />N <br />M <br />0 <br />0 <br />ty``,14tiuS;Fdli! <br />LE VVA- <br />r -fi' ST 1. <br />OF <br />C) • <br />rfr A`t! <br />N PA - <br />1 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Flodda Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structursl engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />0 <br />g <br />E <br />8 <br />ti <br />A D <br />0 <br />Y2 y <br />a <br />� <br />� <br />Q <br />M ! # LL <br />N lL LL W <br />� <br />L a <br />0 <br />@C � <br />ILZ <br />co <br />= <br />Nox <br />OU 0 <br />W <br />❑❑ <br />Z N � z <br />a <br />d N <br />N <br />z <br />O <br />- <br />4-+ <br />'U <br />� a <br />t0 <br />0 <br />LU s <br />N <br />�N <br />c <br />= 3 <br />W <br />= r <br />C tR <br />Y <br />QCq <br />Q <br />CD <br />�w <br />Z <br />M <br />� <br />go <br />zo <br />> <br />Q <br />o. E <br />�� <br />�2 <br />zD <br />0 <br />lca ro <br />E <br />N <br />QQo <br />X U <br />ao <br />�o <br />°� <br />=O 0 <br />�M <br />rw <br />ro <br />- C <br />2<Zz <br />OY <br />ma <br />ZLL <br />zU)C <br />J <br />�� <br />aw <br />sZ <br />u� <br />8 <br />5. <br />W <br />3 <br />.O <br />.0z <br />TOK <br />g <br />co <br />v� <br />ON <br />° 3 <br />c <br />10277 <br />m <br />N <br />U� <br />cfl <br />Cib <br />M <br />O <br />� <br />W <br />N <br />I.6 <br />c <br />N <br />r- <br />/^ m <br />V / <br />O <br />0o <br />_ <br />CM <br />N <br />I- <br />O <br />N <br />00 <br />J <br />LO <br />0o <br />CN <br />,-- <br />E <br />cc <br />C <br />Z <br />E O <br />y <br />`m <br />c <br />a <br />E <br />U <br />o <br />¢ p <br />c <br />JOB <br />NO : 21-17091-17908 <br />SCALE : <br />AS NOTED <br />SHEET <br />