Laserfiche WebLink
THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METAL LATH <br />16GAx1-1\2" LONG (3/4"-1" CROWN) <br />STAPLES @ 6" O.C. VERT BETWEEN <br />STUDS (NOTED THUS:—) - OFFSET <br />STAPLES BETWEEN STUDS AS SHOWN <br />WALL SHEATHING <br />16GAx1-1/2" LONG (3/4"-1" <br />CROWN) STAPLES @ 6" <br />O.C. VERT INTO STUDS <br />(NOTED THUS;—) <br />METAL LATH ATTACHMENT DETAIL <br />REV. 09.24.21 SCALE: 3/4" = V-0" <br />*DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 703.7.1 LATH* <br />**ONLY APPLIES TO LENNAR TPA/JAX** <br />10'-0" <br />TANK -LESS W/H <br />CORNER OF L_ <br />HOME H C G <br />GARAGE SIDE O 0 0 <br />5'-0" Q - <br />STUB -OUT FOR 1'-0" 0 9 <br />GAS METER 0 O <br />� U <br />b � <br />N <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />**ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" Q.C. <br />T-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />(1) SIMPSON HTS20 OR 3)16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'-4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Backer and Filter Block Dimensions <br />BCI®Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" orp <br />5000s 1.$/1.7 <br />nel <br />wood panels <br />Two 3/4" wood panels or 2 x <br />P _.._ <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-118" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 112" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2 x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONS <br />(Not required if both loa <br />Filler <br />1/8" gap <br />FILL CELL STD. 900 HOOK BOND BEAM <br />cn <br />w <br />cc <br />STD.90° CONT. #5 <br />CONT. #5 <br />HOOK BAR <br />BAR <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />v BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN PLYWOOD FLOOR <br />SEE PLAN FOR REQ'D SHEATHING PER PLAN <br />COLUMN AND <br />CONNECTION TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />Solid block all posts from # OF 2nd FLOOR <br />above to bearing below. STUDS <br />SECTION @ INT. BRG. WALL <br />N.TS. <br />1/8" min. }Small gap 2° min. <br />2. <br />max. � 4 max, <br />7-7 <br />4 <br />Clinch nails <br />when <br />possible <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4 Place joists together and nail from each side with 2 rows of 10d nails 2x4/Plywood/OSB web stiffener 2" min. <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT ) at 12" o.c., clinched when possible. Stagger rows from opposite required when indicated or 4" max. <br />OF THE JOIST ASA REQUIRED LEAVING Y8" GAP TOP sides b 6". - Hangers with side nailing. <br />@ Y -Hangers with sides not containing WEB STIFFENER <br />top flange of joist. STIFFENER <br />DOUBLE JOIST CONNECTION - Birdsmouth cuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />N.T.S. higher than 15001b <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />*Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />wall or beam below.* <br />consideration. Check <br />local building <br />code for appropriate <br />1/16 <br />details in <br />One 10d box <br />areas=20 of high <br />or=20 sinker <br />lateral load. <br />4 <br />nail each side <br />at bearing. <br />Squash block / <br />(2x4 minimum) J <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />Boise Joist Blocking <br />Use 3" (10d) nails at 6" o.c. <br />Provide adequate bearing <br />for each lapped joist. <br />odnails SECTION @ INT. BRG. WALL <br />N.T.S. <br />NO HOLES (EXCEPT MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D <br />(see table below) (KNOCKOUT EXEMPTS) D <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />Web Stiffener Fastener Schedule <br />Joist Bearin Location <br />Series —Depth End Intermediate <br />BC15000s <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />_ <br />5-8d <br />BCI 6000se <br />BCI6500s® <br />9-1/2" <br />1 t-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BC1600 <br />114/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI90s® <br />11-7/8" <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : - for vertical load transfer y ,-- Plumbing <br />when load bearing - for lateral support when joists jbeo�ffset <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.*Joist <br />When joists meet over wall, provide <br />13/4" minimum bearing for each. 1-Joisup to 3to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />Use 10dx3" nails at 6"o.c, for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration. — <br />ri 6.4 A %" ROUND HOLE MAY 6" 6"" DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1Y" <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1)/" <br />NOTES: <br />1, JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3, REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1Y" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9, THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />N.T.S. <br />Joist hanger <br />SIMPSC <br />w/ (22) <br />NAILS T <br />5/8" � <br />THRU <br />BOLT <br />SIMPSC <br />w/(22) <br />NAILS 1 <br />R TRUSS <br />OP PLATE <br />C <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />01N. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON META12 / <br />META12 TSS INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />. <br />Backer block (12" wide min.) <br />Nail with 10-10d nails. — <br />Install tight to top flange. SLEEVE THRU STEM ° <br />°.. <br />SEE PLAN FOR °• °d .. • <br />FOUNDATION INFO ` <br />STEM FOUNDATION <br />GRADE <br />Filler block. <br />\ Nail with <br />10-10d Waifs. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4%2" gap <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4%2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />-0.6 X Joist <br />p / depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />REINF, SEE PLAN <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />'`® LOCATION OF <br />SECOND H10A <br />SIMPSON H10A ° ° (WHEN <br />w! (18)10d x 1 1/2" REQUIRED) <br />NAILS <br />UPLIFT = 1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />i HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />d .. a <br />Tiil <br />PLUMBING LINE <br />i-- PVC OR SCH40 SLEEVE <br />a <br />A C <br />° 4. <n I �IIIIIII'IIIII"`III �I) <br />• :I 112 I I. <br />�--- SEE FND. PLN. <br />SIZE & REINF. <br />12" BELOW PIPE VERTICAL THRU FND. <br />GRADE <br />TOP (2) #5's x 4'_ 0" <br />CENTERED @ RIPE <br />PENETRATION <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />^ SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @PIPE <br />PENETRATION PLUMBING LINE <br />® d <br />Q <br />aI- <br />a d <br />d <br />SEE FND. PLN. <br />SIZE & REINF. <br />N, <br />0 <br />C= <br />;t z <br />0 <br />go, / <br />SE <br />a `J ✓ <br />G <br />F LO Z <br />�/r� <br />4. <br />��W4411I <br />II11°'0V <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />N <br />W vE <br />0 <br />1- fit Q ° <br />9 <br />V N 6 m. n <br />a ��P- <br />0 r— I <br />u) <br />N� M CD <br />Qj V <br />u <br />W <br />�i LL LL 0 <br />5 � <br />Z _2 a Y <br />m 0 � m <br />" � O <br />ti � <br />{II O O <br />W rn °' m w <br />1Zi M Z Q <br />Z OU 0 <br />W 0❑ <br />m <br />Z N M <br />o o <br />z W <br />o <br />747- <br />� — <br />N <br />M <br />V I <br />V) 2 <br />C1 <br />o <br />® a <br />U <br />ram, g <br />U)11 c w <br />N � 's <br />C.7 � <br />LU <br />®® <br />Q N 0 <br />I� <br />o <br />w <br />m <br />z <br />o <br />z <br />LL <br />N <br />zo <br />o O <br />2 <br />Z <br />Q N <br />E ® <br />w ? <br />z0 <br />o a <br />U O <br />6 <br />90 <br />— C <br />o <br />o <br />O E <br />a p <br />0 <br />¢g <br />y <br />COQ <br />z <br />U <br />m O <br />0 , <br />W <br />-� <br />z <br />m <br />-z <br />U3 <br />N � <br />p¢ <br />ao <br />w W <br />V <br />O <br />? <br />'2 <br />HMilli <br />v <br />z< <br />aF <br />°� <br />Y^ <br />oIn <br />> d. <br />�i <br />rn <br />N <br />C� <br />r <br />Z6 <br />+co <br />E <br />> <br />0 <br />T <br />co C <br />' <br />O <br />V <br />U <br />mCo <br />LL <br />O <br />� <br />OO <br />r <br />E <br />O O N <br />U—) <br />00 O <br />N N <br />a) <br /><( CD 00 <br />Lo <br />00 <br />r 00 <br />E <br />Ce) r <br />z° <br />z <br />E 0 <br />D <br />E <br />0 J Q <br />JOB <br />NO : 22-12552-12545 <br />SCALE : AS NOTED <br />SHEET NO. <br />S N 1 <br />