Laserfiche WebLink
ROOF FLASHING AND ROOF FLASHING <br />COMPONENTS TO BE IN ACCORDANCE <br />w/ R903.2, FLORIDA BUILDING CODE <br />7TH EDITION (2020) RESIDENTIAL <br />INSULATION — <br />BAFFLE <br />INSULATION PER — <br />CHART ON FLOOR <br />PLAN <br />5/8" OR 1/2" HIGH STRENGTH CEILING <br />BOARD PER CODE W/ 1 3/8" DRYWALL <br />NAILS OR DRYWALL SCREWS 7" O/C <br />CEILING & 8" O/C WALLS <br />1/2" GYP WB <br />DOUBLE 2x S.P.F. TOP PLATE - ATTACH 2x STUDS - <br />TO TOP PLATE w/ (1) SIMPSON SP2 TYP. @ <br />CORNERS, SP2 MAY BE SUBSTITUTED w/ (1) H2.5A <br />2X BLOCKING @ EA. WALL <br />SHEATHING JOINT <br />16" O.C. 2X S.P.F. STUDS <br />2x BOT. PLATE W/ (2)10d @ 6" O.C. <br />3/4" PLYWOOD DECKING GLUED AND NAILED W/ 10d <br />COMMON @ 6" O/C EDGES AND 12" O.C. FIELD <br />1/2" GYP. WB OR 3/8" PLYWOOD/ TYPE 2-M-W <br />OSB (DRAFTSTOPPING) TO BE NAILED W/8d <br />COMMON @ 6" O/C TO ONE SIDE OF THE FLOOR TRUSS FOR <br />AN AREA 51000 SQ. FT. OF FLOOR AREA & SEALED <br />PENATRATION AREA W/ FOAM. DRAFTSTOPPING SHALL <br />DIVIDE THE CONCEALED SPACE INTO APPROX. EQU <br />AREAS. <br />FLOOR SYSTEM <br />\IPIER\ = 0 <br />I <br />zi <br />ae <br />1/2" HIGH STRENGTH OR 5/8" GYP WB (OR 5/8" <br />GYP. TYPE " X" @ GARAGE ONLY) W/ 13/8" <br />DRYWALL NAILS OR DRYWALL SCREWS 7" O/C <br />CEILING & 8' O/C WALLS <br />1/2" GYP WB <br />INSTALLATION PER <br />CHART ON FLOOR PLAN <br />NOTE: LAP SHEATHING TO BOTTOM OF <br />BAND JOIST TYPICAL <br />lx WD FURRING @ 24" O.C: <br />BASEBOARD <br />MIN. 2500 PSI CONC. SLAB <br />MIN. PSI MAY VARY PER <br />MUNICIPALITY <br />.d a '. <br />'T =1 <br />6x6 W1.4xW1.4 I ' e e. <br />'111�1 II <br />WWF OR FIBERMESH - <br />TTi=1TI=ITI e a. <br />FOR UNDERLAYMENT <br />REQUIREMENTS SEE R905.1.1 <br />�-PRE ENGINEERED WOOD TRUSS @ 24" O.C. MAX. <br />HURRICANE ANCHOR @ EACH TRUSS <br />SHINGLE ROOF, SHINGLES TO BE IN <br />ACCORDANCE w/ ASTM D7158-CLASS G or <br />H, or ASTM D3161-CLASS F, IN <br />ACCORDANCE w/ TABLE R905.2.6.1, <br />FLORIDA BUILDING CODE 7TH EDITION <br />(2020) RESIDENTIAL <br />ROOF SHEATHING - SEE <br />SCHEDULE - [RSH] - ON <br />FRAMING SHEET FOR <br />SHEATHING AND FASTENERS <br />ALUMINUM DRIP EDGE <br />ALUMINUM FASCIA <br />2x SUB FASCIA <br />SEE STRUCTURAL SOFFIT SHEET SS <br />ATTACHED WALL SHEATHING TO <br />(2) TOP PLATE W/ 8d @ 4" <br />O.C., 2 ROWS <br />1X2 NAILER <br />~ PLYWOOD SHEATHING <br />NAILED PER NAILING SCHEDULE SEE DETAIL C/S6 <br />FOR MORE INFO <br />W <br />o = 7/8" CEMENTITIOUS FINISH PER ASTM C. 926 <br />oCn APPLY 3 LAYERS W/ TOTAL THICKNESS 7/8" OVER <br />METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. 3RD <br />LAYER 1/8" THICK. <br />Ili W <br />j�INSULATION PER <br />�I�IVV CHART ON FLOOR PLAN <br />B R <br />S6 S6 <br />ETAL SEAT <br />OR FELT <br />PAPER FOR <br />MOISTURE <br />JBARRIER <br />STD. 90N001< (SEE DETAIL) <br />8"x8"X16" CONC. KNOCKOUT <br />BILK. W/1#5 ROD CONT. FILLED <br />SOLID W/GROUT <br />-ARCHITECTURAL <br />FINISH <br />(1) #5 VERT. IN FILL CELLS (SEE <br />FOUNDATION PLAN & NOTES) <br />co <br />v 4"x4" INSPECTION PORT AT <br />EACH FILL CELL TYPICAL <br />w <br />a <br />AT GARAGE CONTRACTOR <br />N <br />TO CUT BLOCK OR POUR <br />7 <br />CURB DUE TO SLOPE <br />NOTE: EXTEND DECO FINISH <br />411to 6" BELOW GRADE <br />=1NISH GRADE00 <br />STD. 90'HOOK <br />(3) # 5 REBAR ON 3" CHAIR I ' 'I I '-` <br />(SEE DETAIL) <br />W/3"MIN. CLEARANCE 4" <br />TYP 2-STORY WALL SECTION r, <br />REV. 03.16.21 <br />SCALE: 3/4"=V-0" <br />B <br />SIMPSON LSTA24 STRAP w/ (8) 10d x 1 1/2" NAILS TO <br />2ND FLOOR FRAME CONNECTION <br />SEE J/S-6 FOR ADDITIONAL INFORMATION. <br />SIMPSON LSTA24 STRAP w/ (8)1Od x 1 1/2" <br />NAILS TO STUD & (8)10d x 1 1/2" TO BAND <br />JOIST AT EA. STUD <br />2nd FLOOR WALL <br />*SIMPSON LTP4 w/ <br />(12) 8d x1 1/2" NAILS <br />@ 24" O.C. <br />1st FLOOR WALL— <br />SIMPSON LSTA24 STRAP w/ (8)10d x 1 112" <br />NAILS TO STUD & (8)1Od x 1 1/2" TO BAND -- <br />JOIST AT EA. STUD <br />2ND FLOOR FRAME CONNECTION <br />@ WOOD 1ST FLR. <br />UPLIFT CAP = 928 PLF <br />SHEAR CAP = 355 PLF <br />SEE J/S6 FOR ADDITIONAL INFORMATION. <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />SPACER <br />BLOCKS <br />'END SHEATHING TO <br />)F BEAM OR GIRDER <br />TE W/ <br />O.C. <br />OR TRUSS/JOIST <br />2"x BOT. PLATE W/ <br />(2)1 Od @ 6" O.C. <br />NOTES: * USE <br />LTP4 & EXTEND <br />SHEATHING TO <br />BOTTOM OF RIM <br />BOARD/BAND <br />JOIST FOR <br />SHEAR WALL <br />ONLY. <br />"T" CORNER <br />TYPICAL "T" AND CORNER <br />DETAILS rN <br />SCALE: N.T,S. S6 <br />2ND FLOOR FRAMING - SEE <br />SECTION JiS6 <br />DECKING ATTACHED WALL SHEATHING <br />TO BOTTOM PLATE/CHORD W/ 8d <br />@ 4" O/C, 2 ROWS STAGGERED <br />FLOOR TRUSS SEE FRAMING PLAN <br />FLOOR TRUSS <br />q <br />°O <br />SEE FRAMING WEEP SCREED <br />CD <br />PLAN INSTALLED PER MANUF. <br />2"x4" CROSS BRACE @ 48°SIMPSON HETA20 w/ (8)10dx1 1/2" <br />O/C FOR THE 1ST 2-0" OF I I NAILS @ 24" O.C. INTO TRUSS <br />END WALL W/ (2)10dx3" @ EA. BLOCKING & MIN. 4" EMBEDMENT <br />END INTO 2"x4" BLOCKING IN KO BLOCK <br />SEE DETAIL 2/D2 FOR <br />MORE INFORMATION <br />2ND FLOOR FRAME CONNECTION R <br />PARALLEL TO MASONRY WALL SCALE: 3/4"=V-0" S6 <br />SEE TYP. 2-STORY WALL SECTION <br />FOR ADDITIONAL INFORMATION, <br />2x STUDS @ 1 <br />2"x BOT. PLATE <br />(2)10d @ 6" 0.( <br />PRE-ENGINEE <br />FLOOR TRUSS <br />FLOOR CONNECTION <br />ATTACHED WALL SHEATHING <br />CONTINUOUS TO BOTTOM RIBBON <br />W/ 8d @ 4" O.C., 2 ROWS STAGGERED <br />2X4 RIBBONS, EACH W/4-16d <br />NAILS INTO EA. FLOOR TRUSS <br />WEEP SCREED <br />INSTALLED PER. MANUF. <br />SIMPSON HETA20 w/ (8)1Odx1 1/2" <br />NAILS AT EA. TRUSS w/ MIN. 4" <br />EMBEDMENT IN KO BLOCK <br />@ MASONRY 1ST FLR. SEE J/S6 SCALE: 3/4"=1'-0" <br />FOR ADDITIONAL INFORMATION. <br />DETAIL FLOOR TRUSS} ro <br />SCALE: 1 1 /2"=V-0" ��S6 <br />NOTE: SEE TYPICAL WALL SEE SHEATHING <br />SECTION C/S3 FOR SPECS ON FLOOR <br />ADDITIONAL INFORMATION <br />1/2" GYP. W.B. MIN. @ <br />2x BLOCKING HORIZONTALLY GARAGE SIDE IF APPLICABLE <br />@ INTERVALS NOT 5/8"DIA. x 10" "J" BOLT W/ 8" <br />EXCEEDING 1U-0" (R302.11) EMBEDMENT @ 24" O.C. W/ <br />SIMPSON SP1 w/ (10) 1Od 2"DIA.X 3/16" PLATE WASHER <br />NAILS AT EA. STUD (MIN. SHEAR 3500#. MIN. <br />2 x STUDS @ 16" O.C. TYPICAL TENSION 2600#.) <br />2X P.T. PLATE 6 x 6 W1.4 x W1.4 WWF OR FIBERMESH <br />p v: <br />..e 4. .e �. a <br />1. <br />III- <br />111-�1 I r—I I I —I I q LL I—IJi [—I I--[-(3) #5 CONT. ON 3" <br />8 —IT j 1 8 TT T 8 I[ CHAIR W/ 3" MIN. <br />CLEARANCE <br />INTERIOR 2-STORY FRAME SECTION ( S <br />SEE TYP. 2-STORY WALL SECTION FOR SCALE: 3/4"=V-0" <br />ADDITIONAL SLAB INFORMATION. <br />S6 <br />15/32" OSB �I <br />EXPOSURE \ I x <br />SHEATHINGIL <br />r <br />PROVIDE <br />II II <br />BLOCKING AS <br />REQUIRED PER <br />D <br />w <br />o SECTION X-X IF <br />II II <br />_ <br />Lu NOT FULL <br />F HEIGHT SHEET <br />C II II <br />0 <br />? <br />I II 11 <br />JI = IL <br />G FLOOR SYST <br />M <br />(2)- 2x TOP PLATE <br />BEYOND I <br />_ <br />SB <br />I I II II <br />EXPOS RE 1 <br />F <br />SHEATHING w <br />IIII II I <br />SOLID 2x <br />III <br />I I II II II I <br />°ATHIN ALL o <br />SBCKING <br />0 <br />� <br />EDGES (SEE <br />III <br />OPENINGHL <br />SECTION -X <br />Lu <br />III <br />C <br />III x <br />II II <br />FxW <br />II <br />IIF <br />E <br />2x STUDS W <br />III <br />BEYOND. <br />SEE PLAN o <br />II I <br />II I II II I I <br />0 <br />ILI <br />I—LiL� <br />I <br />2x4 P.T. BASE <br />2x RIBBON OR VERTICAL A HORIZONTAL PLATE BEYOND <br />BLOCKING SEE PLAN <br />BETWEEN FLOOR WALL SHEATHING <br />SYSTEM °AIAI I rl r-,iA-rI^AI r'%IA^r*%AAA <br />3/8" "S" = NAIL 3/8" <br />SPACING <br />Z-1 <br />.S 3/4' S 1/2„ <br />1/2" — <br />S 112" <br />SINGLE NAIL EDGE SPACING DOUBLE NAIL EDGE SPACING <br />AT ALL PANEL BLOCKING <br />LOCATIONS SHALL BE MIN 2x4 #2 <br />SPF TURNED VERTICAL w/ 7/16" <br />FLITCH PLATE TO w/ (2) 12d <br />TOENAILS EA. END. NAIL FLITCH <br />PLATE TO VERTICAL w/ (4) 8d NAILS <br />(2) 8d NAILS @ 3" O.C. <br />STAGGERED FOR SHEATHING <br />SECTION X-X <br />T�7 <br />SFF off, <br />N <br />2x CRIPPLES @ — <br />16" O.C. W/ (2)12d <br />TOENAILS T/B <br />10d NAILS @ <br />8" O/C TYP, <br />DOUBLE 2x — <br />CRIPPLE STUD <br />TYPICAL (U.N.O.) <br />WALL SHEATHING MAY BE INSTALLED VERTICALLY OR HORIZONTALLY, <br />ATTACH PER NAILING SCHEDULE PANEL EDGES WILL NEED TO BE <br />ATTACHED TO STUD AND OR BLOCKING AT ALL EDGES. A MINIMUMY" <br />SPACE IS RECOMMENDED BETWEEN PANELS AT EDGES AND END <br />Lu <br />JOINTS TO ALLOW FOR EXPANSION. FASTENERS SHALL NOT <br />F <br />PENETRATE SURFACE MORE THANy". <br />z <br />UA NAIL AT BASE 2 ROWS @ 4" O.C. w/ 8d COMMON NAIL <br />O <br />Q NAIL AT TOP PLATE TWO ROWS @ 4" O.C. w/ 8d COMMON NAIL <br />LL <br />Q NAIL OPENING PERIMETER w/ (2) ROWS @ 4" O.C. w/ 8d COMMON NAIL. <br />O <br />OD NAIL INTERIOR AT 6" O.C. w/ 8d COMMON NAIL. <br />u=i <br />O STAGGER ALL VERTICAL JOINTS & NAIL @ 4" O.C. <br />J o <br />wl 8d COMMON NAIL <br />J <br />w E � O <br />O PLYWOOD SPLICES @ HEADER - NAIL SHEATHING TO HEADER <br />J > ¢ � O a <br />¢ <br />w/ 8d COMMON NAILS @ 4" O.C. (2) ROWS @ TOP & BOTT. <br />rrro0rn <br />o LL W' <br />Q (2) 8d NAILS @ Y O.C. TO EACH TRUSS END OR @ VERTICAL <br />Z N W p 0 <br />MEMBER IF GABLE END <br />U. w LL <br />NOTE: <br />C WALL SHEATHING INSTALL. <br />S6 & NAILING SCHED. <br />REVISION 12-7-2020 <br />• 8d NAILS FOR WALL SHEATHING MUST BE MIN .13V X 21/2" <br />DO NOT OVERDRIVE NAILS, FASTENERS SHALL NOT PENETRATE <br />SURFACE MORE THAN 1/8", <br />2-ROWS 12d NAILS <br />STAGGERED @ 12" O/C EACH <br />FACE OR 3-ROWS 12d NAILS <br />STAGGERED @ 12" O/C FOR <br />2"x10" OR GREATER HEADER <br />SEE FLOOR PLAN NOTES FOR <br />REQUIRED CONNECTION <br />(2) 2x HEADER SEE PLAN <br />S4 INTERIOR HEADER: <br />BOX HEADER (1) 2x SILL PLATE W/ (2) <br />ONLY 12d TOENAILS <br />• EXTERIOR HEADERS: <br />(1) 2x SILL PLATE W/ (2) <br />12d TOENAILS <br />• OPENING LARGER THAN 4 FT: <br />(1) 2x SILL PLATE w/ SIMPSON <br />LS30 w/ (6)10d x 1 1/2" EACH SIDE <br />OpFN 0 R <br />SEE PLAN FOR REQUIRED <br />CONNECTIONS <br />LOAD BEARING/EXTERIOR FRAME <br />WALL HEADER DETAIL <br />2x STUDS TYP. <br />P.T. BOT. PLATE <br />FLOOR TRUSS <br />2x BLOCKING HORIZON <br />T <br />@ INTERVALS NOT <br />EXCEEDING 10'-0" (R302.11) <br />5/8"DIA. x 10" "J" BOLT W/ 8" <br />EMBEDMENT @ 24" O.C. W/ 2"DIA. <br />x 3/16" PLATE WASHER (MIN. <br />SHEAR 3500#. MIN. TYPICAL <br />TENSION 2600#.) <br />2500 PSI CONCRETE MIN. <br />SLAB W/ 6x6 W1.4xW1.4 <br />WWF OR FIBERMESH <br />C .•A. ,•d e" ri n <br />M e e" a <br />1�11111�111111111 9 �. <br />_ --- <br />1�1 1111 e_ e_I <br />I III — <br />III <br /># 5 REBAR ON 3" CHAIR 4" 1 �-8" <br />((8 <br />/3" MIN. CLEARANCE <br />ALTERNATE FOOTING <br />M <br />S6 <br />HEADER SUPPORT <br />NO, OF JACKS & STUDS <br />REQ. AT OPENINGS <br />OPENING <br />2" x 4" WALL <br />2" x 6" WALL <br />STRAPS <br />JACKS <br />I STUDS <br />JACKS <br />STUDS <br />SIMPSON <br />SIZE <br />EA END <br />EA END <br />EA END <br />EA END <br />1'4 <br />(1) <br />(2) <br />(1) <br />(2) <br />(1) LSTA30 <br />4'-9' <br />(2) <br />(3) <br />(2) <br />(2) <br />(1) LSTA30 <br />(3) <br />(3) <br />(2) <br />(3) <br />F (2) FTA30 <br />PLYWOOD SHEATHING NAILED PER NAILING <br />SCHEDULE SEE DETAIL C/S6 FOR MORE INFO <br />2X STUDS @ 16" O/C <br />7/8" STUCCO FINISH PER ASTM C. 926 <br />APPLY 3 LAYERS W/ TOTAL THICKNESS <br />7/8" OVER METAL LATH. FIRST 2 LAYERS <br />3/8" THICK EACH. 3RD LAYER 1/8" THICK. <br />SIMPSON SP1 w/ (10)10d NAILS <br />AT EA. STUD <br />2X P.T. PLATE <br />WEEP SCREED INSTALLED PER, MANUF. <br />00 <br />FINISH GRADE <br />co <br />;III„II a T <br />@ WOOD 1ST FLR. SEE J/S6 FOR SCALE: 3/4"=V-0" <br />ADDITIONAL INFORMATION. <br />cra <br />CNJ <br />CnI <br />c <br />ct <br />ci <br />_ cac—)C�A <br />��>e <br />� a_ <br />R CZ L <br />y> -C, <br />a., cn <br />v <br />to ,.a .s.7 <br />a <br />o w tv <br />E- <br />ti <br />U �• �O <br />F) �.*�_ <br />1?0 <br />� ►tire o��`` <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal Is only for <br />the structural engineering portions <br />of the drawing pages bearing <br />Engineer's signature and seal. <br />N <br />W <br />Q0 <br />E <br />co 8 <br />v <br />C <br />0 CV 0 <br />�� <br />p <br />tnti�� <br />M <br />Q <br />0 <br />Q M V :&w <br />C J LL LL w <br />w a <br />w <br />sm9 z� <br />wZ_/. <br />W <br />W <br />7 'M r- �_ <br />og <br />W <br />ILZ <br />W °' <br />co M Z ¢ <br />a <br />Z <br />N <br />°U U <br />W <br />V M C, <br />z N O <br />o <br />Z OHO N <br />z I; <br />a <br />J <br />U) <br />c/1 <br />-- N <br />M <br />;2! <br />U' <br />S <br />4-1 <br />0 <br />W <br />c <br />V) <br />�N <br />v � <br />W R <br />E <br />o �•,.- <br />_ $Rig <br />A <br />®0 <br />N <br />CD <br />w <br />M <br />z <br />Z <br />a <br />ce E <br />zo <br />>g <br />ZN <br />Q o <br />Co V <br />wO <br />o0 <br />Co <br />_ <br />_° <br />0 <br />. E <br />C:. <br />p <br />0 <br />¢ <br />a z <br />L <br />U) C <br />Z <br />C)Y <br />'0 <br />O� <br />N <br />J <br />"-� <br />a ° <br />aw <br />z z <br />to <br />w <br />g <br />ZO <br />5 0 <br />a <br />Q <br /><0 <br />mw <br />_� <br />C.T% <br />Qo <br />oLL <br />A <br />o <br />z <br />wz <br />>0 <br />to <br />a <br />C <br />•° T^ <br />u: <br />hi <br />r <br />C.C> <br />A <br />O <br />r <br />fD <br />3 <br />co <br />c <br />C:)' <br />_� <br />O <br />W <br />1.[ <br />�_ <br />C m <br />COo <br />00 <br />0) <br />� <br />co <br />O <br />r <br />-1 <br />c,4 <br />O 04 <br />LO <br />4-1 <br />00 0 <br />O <br />n N <br />O <br />LA-)aico <br />CO <br />r <br />N <br />M r <br />d <br />N <br />_ <br />C O <br />W <br />Z <br />Z <br />E <br />Cn <br />L <br />c <br />a <br />.° <br />a o <br />JOB <br />NO : 22-12552-12545 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />S6 <br />(MONO) <br />