*DIAGONAL SPACED <br />AT 15'-0" O.C. MAX <br />CONTINUOUS LATERAL <br />BRACING- NAIL OVER <br />X-BRACE AS SHOWN - <br />INSTALL BLKG. AT TRUSS <br />WEBS FOR NAILING <br />CROSS BRACING DETAIL (TYP.)_ <br />SCALE: 1/2" = V-0" <br />(2)-12d TOENAILS <br />EACH SIDE STRUCTURAL SHEATHING <br />ATTACHED PER NAILING <br />PROVIDE 30" LAP SPLICE SCHEDULE <br />@ F.C. REBAR. `F <br />SEE ROOF PROVIDE 2X4 MIN. BLOCKING AT VARIES W/ <br />ROOF SLOPE <br />PLANW SHEATHING O OF HIP/RIDGE, TYP.BETWEEN (2) ROWS OF 10d NAILS @ 4" O.C. <br />BLOCKING TRUSSES W/ (2) 12D NAILS EACH <br />END TO TRUSS TOP CHORD g n ° MASONRY WALL <br />TYP MASONRY WALL 2X6 P.T. CONT. SEE FLOOR MIN. 2x4 #2 SPF P.T. <br />2X4 BLOCKING FLOOR TRUSSES SEE PLAN LEDGER T&B W/ (2) PLAN FOR MORE CONT. W/ (2) 4'x3" <br />BETWEEN TRUSSES TRUSS @ 24" O.C. 1/4" X 3" TITEN2 @ 24" INFO. TITEN2 SCREWS @ <br />SECT. A -A XA <br />O.C. T&B 16" O.C. <br />TRUSS OR <br />ROOF SYSTEM <br />G.T. <br />ADD 2X4 ALONGSIDE <br />TOP CHORD WHEN REQ'D DOUBLE KNOCK -OUT TRUSS <br />X-BRACING - 2x4 SPF OR TO PREVENT PLYWOOD BLOCK W/ (1) #5 ALTERNATE: <br />SPAN FROM EXCEEDING ACK CONT. IN EACH (2)2x8 SYP #2 P.T. <br />SYP w/ 2 16d @EACH TRUSS MAX 24" SPAN (EITHER USSES HIP COURSE LEDGER ATTACHED TO MASONRY W/ <br />WEB SIDE OR BOTH IF REQ'D) G.T (2) 5/8" DIA. TITEN HD MIN. 5" <br />EMBEDMENT PER 54/D1 SPACING SIMPSON LUS26 w/ S H EAR T RAN S F E R <br />@ (6).162" x 3 1/2" NAILS EXTERIOR. WALL SIMPSON HGAM10 TRUSS TO LEDGER & 52 <br />(2) 12D NAILS 4'-0" O.C. T & B (4) .148" x 1 1/2" <br />AT 12" O.C. MAX SCALE: 3/4" = 1'-0" FLOOR ATTACHMENT 50 LEDGER DETAIL 51 <br />HIP/RIDGE BLOCKING DETAIL 2 SCALE: 3/4" = V-0" SCALE: 3/4" = V-0" <br />TRUSS NOTES: <br />CONV. FRAMED RIDGE <br />1. WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TP1-2014 MAY BE NAILED <br />(TRUSS PLATE INSTITUTE) NOTE THAT THE COMBINED WIND AREA IS GREATER w/ MIN. (4) 12d WHEN <br />BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE IT LANDS NEXT TO <br />INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST PRE-ENG. TRUSS <br />COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES <br />OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD <br />SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & <br />SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION <br />OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED <br />ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER <br />A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. <br />2. ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS <br />LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTURER ALL LATERAL BRACING <br />SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'-0" <br />O.C. MAXIMUM. <br />3. ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED W/ 2-16D <br />NAILS AT EACH TRUSS INTERSECTION. CB <br />4. ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS <br />DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT <br />ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. Dg <br />5. PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS <br />DEPTH EXCEEDS STANDARD HEEL HEIGHT. SEE TYP. TRUSS BLOCKING DETAILS <br />2X4 BLOCKING <br />2X4 DIAGONAL AT 8'-0" O.C. BETWEEN EA. TRUSS CONT. ROOF SHEATHING AT TRUSS TOP — <br />MAX & EACH END ALTERNATE 'RR • CHORD AT ALL HAND FRAMED AREAS TYP. <br />DIRECTION TYP. <br />DIAGONAL - <br />AT 8'-0" <br />MAX <br />TYP. HAND FRAMING ABOVE TRUSS <br />2X4 STUDS & PLATES AT 2'-0" O.C. <br />EACH DIRECTION TYP. U.N.O.—t <br />TRUSS <br />SCALE: 1 /2"=V-0" <br />VERTICAL SCAB <br />2 x 6 #2 SPF 48" O.C. <br />Wl (4) 10d TOP & <br />BOTTOM OR SIMPSON H2.5A <br />W/ (10) 8d NAILS <br />COLLAR TIE <br />EVERY 3rd <br />RAFTER <br />2x4 SPF 2 <br />(2) 47X 3-1/2" WOOD <br />SCREW EACH TRUSS <br />OR SIMPSON H2.5A @ 48" O.C. <br />BEVEL CUTS <br />(OPTIONAL) <br />2x8 #2 SPF RIDGE BEAM <br />2x6 #2 SYP RAFTERS FOR SPANS 4FT <br />TO 8FT 2X4 RAFTERS FOR SPANS LESS <br />THAN 4FT @ 2'-0"0.C. MAX. w/ (3) 10d <br />COMMON TOENAILS TO RIDE BEAM <br />2X4 CONT. AT—/ CONC. MASONRY <br />T & B CHORD STEEL OR WOOD <br />BEARING SUPPORT <br />A -A ALTERNATE BLOCKING <br />DETAIL @ INTERIOR BEARING <br />WOOD TRUSS SCALE: 1/2" = 1'-0" <br />A PROVIDE BLOCKING AT ALL TRUSS BEARING <br />SUPPORT WHERE TRUSS DEPTH EXCEEDS <br />STANDARD HEEL HEIGHT <br />TYP. <br />WOOD TRUSS <br />BLOCKING DETAIL <br />SCALE: 1/2"=V-0" <br />2 x P.T. BLOCKING BY FRAMER FOR <br />PLYWOOD EDGE NAILING w/ (2) 1/4"x3" TITEN2 <br />(2) SIMPSON SDWC15600 SCREWS @ <br />EACH TRUSS TO LEDGER <br />1/2" GYP. WB <br />OR 3/8" PLYWOOD/ TYPE 2-M-W <br />OSB (DRAFTSTOPPING) TO BE NAILED W/8d <br />COMMON @ 6" O/C TO ONE SIDE OF THE <br />FLOOR TRUSS FOR AN <br />AREA S 1000 SQ. FT. OF <br />FLOOR AREA & SEALED - <br />PENETRATION AREA W/ <br />FOAM. DRAFTSTOPPING <br />SHALL DIVIDE THE <br />CONCEALED SPACE INTO <br />APPROX. EQUAL AREAS. <br />DOUBLE KNOCK -OUT <br />BLOCK w/ (1) #5 CONT. <br />IN EACH COURSE. <br />FLOOR CONNECTION @a EXTERIOR <br />PROVIDE 25" LAP <br />SPLICE @ F.C. REBAR <br />TOP -CHORD BEARING <br />FLOOR TRUSSES @ <br />24" O.C. <br />2) 2x8 SYP #2 P.T. <br />LEDGER ATTACHED TO <br />MASONRY w/ (2) ROWS <br />5/8" SIMPSON TITEN HD, <br />MIN. 5" EMBEDMENT @ <br />24" O.C. STAGGERED @ <br />12" O.C. <br />WALL 53 <br />E <br />SCALE: 3/4" = V-0" <br />2'-0" MIN. <br />LAP SPLICE <br />1'-0" 6" 6" V-0" 6" 6" <br />TYP. TYP. <br />O O 1 O O O O I <br />I SPLICE <br />O O O O O O <br />2'-011 SPLICE BEYOND 2'-0" <br />PART. ELEV. VIEW <br />L <br />DBL. KO. BLOCK <br />b.. <br />o.. -- ---- <br />MIN. TYP. <br />MIN. <br />a <br />a <br />a <br />24" MIN. <br />(2) 2x8 P.T. <br />ATTACHED <br />(2) 2x8 SYP #2 P.T. CONT. <br />LEDGER w/ (2) ROWS OF 5/8" <br />TITEN HD STAGGERED @ 24" <br />O.C. w/ 5" EMBEDMENT & 6" <br />EACH SIDE OF SPLICE & <br />EACH END. <br />LEDGER <br />LAP SPLICETOGETHER w/ <br />PART. PLAN VIEW (2) ROWS OF 10d @ 6" O.C. <br />LEDG k SPLICE DETAIL 54 <br />SCALE: 3/4" '-0" <br />WOOD TRUSS <br />OPTIONAL 6" WIDE BOARD <br />BATTEN STRIPS TO <br />ELIMINATE 3/4" AIR SPACE. <br />SEE MANUFACT. SPECS. <br />FOR INSTALLATION.—-,, — <br />PRE-ENGINEERED ROOF \ <br />TRUSSES AT 24" O.C. MAX <br />(2) LAYERS 1"x24" PROPRIETARY TYPE <br />"X" GYP. PANELS INSERTED BETWEEN <br />2" FLOOR & CLG. RUNNERS W/ 2" <br />STEEL H STUDS BETWEEN ADJACENT <br />PAIRS OF GYP. PANELS. <br />2" FLOOR RUNNER <br />W/ 3/16" DIA. x 1 3/4" <br />TITEN2 @ 16" O.C. <br />FIRE CAULK <br />RUNNER TO BLOCK <br />WALL EACH SIDE <br />NOTES: <br />1. SEPARATION WALL IN THE <br />ROOF SYSTEM PROVIDES <br />2-HRS. PROTECTION PER <br />GA FILE ASW 1002. <br />6" WIDE 1/2" DENSARMOR PLUS FIREGUARD-C OR <br />TOUGHROCK FIREGUARD-C GYPSUM BOARD <br />NO MINIMUM AIR SPACE <br />w/ BATTEN STRIPS <br />1" DENSGLASS ULTRA <br />SHAFT LINER <br />DETAIL - ADJACENT TO TRUSSES <br />GA FILE ASW 0810 SCALE: 3/4"=V-0" <br />2x4 BLOCKING @ 48" O.C. MAX. W/ 0 LB FELT (SHINGLES) <br />(2)16d TOE NAILS @ EACH END FIRE RESISTANT OSB 7/16" <br />2" CLG. RUNNER FIRE CAULK SHEATHING 4' ON EA. SIDE <br />RUNNER TO SHEATHING OF WALL NOT STAGGERED CEILING BOARD <br />ABOVE AT EACH SIDE-? OVER PARTY WALL <br />STD 909 HOOK <br />2. MASONRY WALL PROVIDES (1) 45 VERT. IN FILL CELLS <br />2-HRS PROTECTION PER (SEE FILL CELL PLAN FOR <br />UL-U905 (see sht 9) LOCATIONS) <br />2 x P.T. BLOCKING BY FRAMER FOR PLYWOOD EDGE NAILING <br />w/ (2) 1/4"x3" TITEN2 <br />(2) SIMPSON SDWC15600 SCREWS @ EACH <br />TRUSS TO LEDGER <br />(2) 2x8 SYP #2 P.T. CONT. LEDGER wl (2) ROWS OF 5/8" <br />TITEN HD STAGGERED @ 24" O.C. w/ 4" EMBEDMENT & 6" <br />EACH SIDE OF SPLICE AND EACH END SEE 54/D1 <br />3/4" PLYWOOD DECKING GLUED AND <br />NAILED W/ 8d COMMON AT 6" O.C. <br />EDGES AND 12" O.C. FIELD <br />1/2" GYP. WB. OR 3/8" PLYWOOD/TYP 2-M-W <br />OSB (DRAFTSTOPPING) TO BE NAILED W/ <br />8d COMMON AT 6" O.C. TO ONE SIDE OF TOP CH <br />FLOOR TRUSS FOR AN AREA < 1000 S.F. 00 S TEi <br />AND SEALED PENETRATION AREAS W! <br />FOAM. DRAFTSTOPPING SHALL DIVIDE <br />THE CONCEALED SPACE INTO APPROX. <br />EQUALAREAS <br />(1) LAYER 1/2" HIGH STRENGTH OR 5/8" GYP.—// <br />(OR 5/8" GYP. TYPE "X" @ GARAGE W/ A <br />HABITABLE ROOM ABOVE) W/ 1 3/8" <br />DRYWALL NAILS OR DRYWALL SCREWS 7" <br />O.C. CEILING, 8" O.C. WALLS & 4" O.C. <br />EDGES <br />PROVIDE 2x BLOCKING W/ (2) 12d NAILS EA. END BETWEEN <br />TRUSSES 4'-0" FROM SEPARATION WALL. SOLID BLOCKING <br />12 BETWEEN TRUSSES TO BOTTOM SIDE OF PLYWOOD. BLOCK <br />SEE MUST BE "PITCH CUT" (SEE ELEVATIONS) TO PROVIDE AS <br />ELEV. MUCH CONTACT AS POSSIBLE TO UNDER SIDE OF ROOF <br />DECK. ALL JOINTS AROUND BLOCKING MUST BE CAULKED <br />WITH APPROVED FIRE CAULKING. - <br />2x4 LEDGER @ 48" O.C. SEE ROOF PLAN <br />MAX VERTICALLY NAILED FOR STRAP INFO. <br />TO TRUSS WEBS W/ (2) 8d BASE BOARD PER SPECS. <br />(TYP.) <br />EXTEND BURN CLIPS AS PER 2 x P.T. BLOCKING BY FRAMER <br />FIRE WALL MFG. FOR PLYWOOD EDGE NAILING <br />R30 INSUL. MIN. SPECIFICATIONS NAILED INTO W/ (2) 1/4"x3" TITEN2 <br />2x4 LEDGER ONLY AT EACH <br />SIDE OF STEEL "H" STUD. <br />(2) SIMPSON SDWC15600 <br />(1) LAYER 1/2" HIGH STRENGTH SCREWS @ EACH TRUSS TO <br />OR 5/8" GYP. WB. W/ 1 3/8" LEDGER <br />DRYWALL NAILS OR DRYWALL <br />SCREWS 7" O.C. EDGES. <br />SIMPSON RBC @ 36" O.C. W/(6)10d X 1 1/2" NAILS 3/4" FLOOR <br />INTO TRUSS BOTTOM CHORD/SCAB & (3)1/4" X 2-3/4" SHEATHING <br />TITEN SCREWS INTO MASONRY. NOTE: RBC CLIPS <br />TO BE INSTALLED PRIOR TO FURRING STRIPS <br />INSTALLATION (TYP. ON BOTH FACES OF WALL) <br />1x P.T. NAILER INSTALLED <br />AFTER INSTALLING RBC'S 1/2" GYP. WB OR 3/8" <br />8"x8"x16" CONC. KNOCKOUT PLYWOOD/ <br />BLK. W/ 1 #5 ROD CONT. TYPE 2-M-W OSB <br />FILLED W/ GROUT (DRAFTSTOPPING) <br />4"x4" INSPECTION PORT AT 0 BE NAILED W/8d <br />EACH FILLED CELL (TYP.) COMMON @ 6" O/C TO <br />�--1x P.T. BASE NAILER ONE SIDE OF THE <br />--STD. 909 HOOK FLOOR TRUSS FOR AN <br />(SEE DETAIL) AREA :5 1000 SQ. FT. OF <br />NAIL FLOOR TRUSS TO LEDGER W/ FLOOR AREA & SEALED <br />(4) 10d TOENAILS (TYP.) EA. SIDE PENETRATION AREA W/ <br />FOAM. DRAFTSTOPPING <br />SHALL DIVIDE THE <br />\ (2) SIMPSON SDWC15600 SCREWS @ CONCEALED SPACE INTO <br />EACH TRUSS TO LEDGER APPROX EQUAL AREAS <br />DOUBLE KNOCKOUT BLOCK W/ (1) #5 ROD <br />CONT. IN EA. COURSE FILLED W/ GROUT <br />1" P.T. NAILER <br />R-3 MIN, INSUL. PER. FBC. <br />1/2" GYP. WB. <br />(1) #5 VERT. IN FILL CELLS (SEE <br />FOUNDATION PLAN FOR LOCATIONS) TYP. "S" MORTAR (TYP.) <br />.. U <br />8" CONC. BLOCK (TYP.) PER UL905 <br />�a_ <br />1x P.T. BASE NAILER [c, 4 <br />N <br />6x6 W1.4xW1.4 WWF. g 4"x4" INSPECTION PORT. AT <br />EACH FILLED CELL (TYP.) <br />_ o <br />(4) #5 CONT. _ STD. 909 HOOK <br />ON 3" CHAIR 8" 2'-0" 8" (SEE DETAIL) l WU1\ <br />2-STORY PARTY WALL SECTION P <br />SCALE: 3/4"=V-0" <br />PRE-ENGINEERED------ <br />FLOOR TRUSS' AT <br />24" O.C. <br />GYP. BOARD CLG. <br />SEE 53/D1 FOR <br />LEDGER CONNECTIONS <br />1/2" GYP. BD. — <br />(2)-1 X 4 P.T. BASE —� <br />NAILER <br />BASE BOARD <br />PER SPECS. —� <br />CONC. SLAB <br />SEE FOUND. PLAN <br />6 MIL VISQUEEN —\ <br />SEE PLAN <br />TOP OF PLATE <br />—TOP COURSE W/ <br />-- LINTEL SEE <br />PLAN <br />SEE PLAN <br />OP OF WINDOVV_ <br />WINDOW PER PLAN <br />8" C.M.U. WALL <br />10'-8" <br />DOUBLE KNOCK -OUT <br />W/ (1) #5 CONT. IN. <br />EACH COURSE <br />REINFORCING W/ MATCHING <br />#5 DOWELS IN SOLID <br />GROUTED CELL W/ MIN. 25" <br />LAP SPLICE MIN. <br />8" C.M.U. WALL <br />TOP OF SLAB 0'-0' <br />F. F. <br />00 <br />VARIES WITH <br />Ir o SITE GRADES <br />TREATED SOIL - `" SEE PLAN <br />N <br />1-10 <br />0 0 <br />3 #5 CONT. 20" <br />TYP. 2 STORY WALL SECTION 55 <br />SCALE: 3/4" = V-0" <br />REV. 08.20.21 <br />ga!g <br />:ccC L <br />C-Ax- <br />HR <br />", <br />to v <br />'tit <br />���i��10i13111►IJIOI <br />x <br />ROW /4r�i <br />SE <br />••N_ <br />C , <br />�� 0 <br />�y :• <br />aid <br />F LQ •'• ``' <br />�� <br />E SS.10 <br />fill 1'1ll"01 ��� <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />to <br />W <br />I" <br />of <br />O fh E <br />O <br />W N m <br />�� <br />VJ So <br />� � J <br />Q <br />C L- <br />-r W <br />J LL LL d <br />�% <br />Z <br />13 <br />W <br />—vim a 4 <br />L Z <br />w o <br />N <br />U) C w <br />Z <br />IL <br />ILW <br />. <br />J <br />MZ a <br />Z <br />N O U < <br />W <br />❑❑ <br />z N M <br />vCc <br />z o <br />a <br />J <br />o LO <br />V) <br />M <br />z <br />cD a <br />cu <br />ry <br />p m <br />U <br />0 <br />V) <br />N <br />w o <br />._ <br />U <br />f— J E <br />c "' <br />0 <br />N <br />o <br />M <br />w <br />M <br />m ¢2 <br />o S <br />V5o <br />Z <br />i <br />LL <br />>� <br />oE <br />O <br />Woz® <br />z <br />oa <br />t— <br />CIL <br />O E <br />N¢o <br />M0 <br />�a <br />az <br />C)0 <br />o< <br />az <br />ww <br />i <br />ao <br />Z <br />O Y <br />m2 <br />F o <br />O <br />_ C <br />cn J <br />x� <br />m <br />< " <br />, <br />Q W <br />Z0 <br />fn <br />oa <br />5 <br />a <br />�z <br />3 <br />O <br />¢< <br />� <br />zla <br />a <br />00 3 <br />e <br />T <br />> d. <br />a� <br />m <br />C14 <br />co <br />V! <br />T <br />�_ <br />� <br />� <br />O <br />0 <br />o <br />CD <br />� <br />c'Yi <br />� <br />r <br />- <br />m <br />CD <br />60 <br />CD <br />r <br />0 <br />O <br />�-CN <br />o <br />M N <br />C <br />to 9 <br />CV N_ <br />Q CO <br />o <br />r <br />00 <br />m <br />r <br />N <br />M .— <br />o <br />E <br />E O <br />z <br />z <br />E <br />� <br />= <br />d <br />E <br />U <br />Q 0 <br />10B <br />NO: 22-12552-12545 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />D 1 <br />