My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38049-38075 Fallstone Way
Zephyrhills
>
Building Department
>
Building Plans
>
38049-38075 Fallstone Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 3:11:50 PM
Creation date
2/27/2025 11:19:02 AM
Metadata
Fields
Template:
Building Plans
Street #
38049-38075
Location
Fallstone Way
Contractor
Lennar Homes
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METAL LATH <br />16GAx1-1\2" LONG (3/4%1" CROWN) <br />STAPLES @ 6" O.C. VERT BETWEEN <br />STUDS (NOTED THUS:-) - OFFSET <br />STAPLES BETWEEN STUDS AS SHOWN <br />WALL SHEATHING <br />Backer and Filler Block Dimensions <br />BCI Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" orp <br />5000s 1.8/1.7 <br />nel <br />wood panels <br />Two 3/4" wood an <br />panels or 2 x <br />1-1 /8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />1/8" gap <br />r <br />t <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4) Place joists together and nail from each side with 2 rows of 10d nails <br />16GAx1-1 /2" LONG (3/4%1" 2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite <br />CROWN) STAPLES @ 6" OF THE JOIST ASA REQUIRED LEAVING YB' GAP @ TOP sides by 6". <br />O.C. VERT INTO STUDS <br />(NOTED THUS:-) DOUBLE JOIST CONNECTION <br />N.T.S. <br />METAL LATH ATTACHMENT DETAIL <br />REV. 09.24.21 SCALE: 3/4" = V-0" <br />*DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 703.7.1 LATH* <br />**ONLY APPLIES TO LENNAR TPA/JAX** <br />10'-0" <br />TANK -LESS W/H <br />CORNER OF <br />HOME H C G <br />GARAGE SIDE 0 0 0 <br />5'-0" <br />c� <br />STUB -OUT FOR 1'-0" 0 9 0 <br />GAS METER 0 o <br />� U <br />9 ,- <br />CV = <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) -12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />**ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />1 SIMPSON HTS20 OR 3 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />1) SIMPSON HTS20 OR 4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />81-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />151-4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />over suash=20 blocks and <br />*Non -stacking walls <br />require additional wall or beam below.* <br />consideration. Check <br />local building <br />code for appropriate <br />details in <br />areas=20 of high <br />lateral load. <br />Squash block / <br />(2x4 minimum) —/ <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />z1/16" <br />One 10d box <br />or=20 sinker <br />nail each side <br />atbearing, <br />Boise Joist Blocking <br />Use 3" (10d) nails at 6" o.c. <br />Load bearing walls <br />=5 = Provide adequate bearing <br />for each lapped joist. <br />Odnails SECTION @ INT. BRG. WALL <br />N.T.S. <br />NO HOLES (EXCEPT MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D (KNOCKOUT EXEMPTS) <br />(see table below) D <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />CONT. #5 <br />BAR <br />FILL CELL STD. 900 HOOK BOND BEAM <br />11 <br />cn __ <br />W <br />a STD.90" #5 <br />BAR <br />HOOK BAR <br />BOND BEAM STEP <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN ' <br />PLYWOOD FLOOR <br />SEE PLAN FOR REQ'D <br />COLUMN AND <br />_:::=SHEATHING PER PLAN <br />� ; --rr <br />CONNECTION,"" l <br />f /:.. TJI TO BE CUT TO ALLOW <br />L FOR BLOCKING/TJI <br />�.. MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />Solid block all posts from # OF 2nd FLOOR <br />above to bearing below. STUDS <br />SECTION @ INT. BRG. WALL <br />N.T.S. <br />1/8" min. )Small gap 2" min. <br />2" max. 4" max. Web Stiffener Fastener Schedule <br />f Joist Bearing Location <br />i Series <br />_-- ® <br />BCI 5000s <br />_ -Depth <br />9-1/2" <br />11-7/8" <br />End <br />2-8d <br />2-8d_ <br />T ntmredia- <br />2-8d <br />1 3-8d <br />Clinch nails - <br />when <br />possible <br />BCI 6000s® <br />BCI 6500s® <br />14" <br />9-1/2 <br />111-7/8" <br />14" <br />, <br />2-8d '' <br />2-8d <br />2-8d <br />2-8d <br />_ ---� dd <br />-- - <br />2-8d_ <br />3-8d <br />1 5-8d <br />16" <br />2-8d <br />6-8d <br />Tight fit - --- -- <br />2x4/Plywood/OSB web stiffener - <br />required when indicated or <br />- Hangers with side nailing. <br />- Hangers with sides not containing <br />top flange of joist. <br />- Birdsmouth cuts. <br />- Under 2nd floor column w/ loads <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls: - for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />/—blocking and wall or beam below.* <br />Use 1 Odx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration. — <br />6A 1y" ROUND HOLE MAY J 6" <br />BE CUT ANYWHERE IN CANTILEVER <br />THE WEB. PROVIDE AT <br />LEAST 3" OF CLEARANCE <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Yz" <br />NOTES: <br />DO NOT CUT HOLES <br />LARGER THAN 1Yz" <br />ROUND IN <br />CANTILEVERS. <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2, TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. ty" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE 1Y2" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE, <br />HOLE CUTTING CHART <br />N.T.S. <br />When joists meet over wall, provide <br />—1 3/4" minimum bearing for each. <br />11-7/8" 2-8d 3-8d <br />BCI60s® 14" 2-8d 5-8d <br />16" 2-8d 6-8d <br />_3-16d 3-16d -_ <br />BCI90s® 14"_ 5-16d 5-16d <br />.16" 6-16d 6-16d <br />STIFFENER <br />_,.,--Plumbing <br />2" min. <br />4" max. <br />N.T.S. <br />Joist <br />I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S. <br />Backer block (12" wide min.) <br />Nail with 10-10d nails. <br />Install tight to top flange. <br />Joist hanger <br />i <br />Filler block. <br />Nail with <br />10-10d nails. <br />y <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4%2" gap +--,�� l <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4%2" gap at bottom of top <br />flange. flange. <br />eb stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />1 requirements <br />0'6 X Joist <br />depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />SIMPS( <br />w/ (22) <br />NAILS 1 <br />5/81 <br />THRU <br />BOLT <br />SIMPS( <br />w/ (22) <br />NAILS 1 <br />R TRUSS <br />OP PLATE <br />I.0 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />VIIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON META12 / <br />META12 TSS INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />SLEEVE THRU STEM-/' <br />e, <br />SEE PLAN FOR---' <br />FOUNDATION INFO " a <br />STEM FOUNDATION <br />GRADE <br />A/C CHASE 4" PVC <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />REINF. SEE PLAN <br />(2) #5 REBAR <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />LOCATION OF <br />° SECOND H10A <br />SIMPSON H10A (WHEN <br />w/ (18)10d x 1 1/2" REQUIRED) <br />NAILS <br />UPLIFT =1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />PIPE VERTICAL THRU FND. <br />TOP (2) #5's x 4'-0"- <br />CENTERED @ PIPE <br />PENETRATION <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />cc Z l \ • v. • <br />L a <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION PLUMBING LINE <br />;.- d o e av n <br />— d ao <br />G . Q -1 F11771° <br />,r1111I`�I1 v .. I1 - T—I <br />SEE FND. PLN. <br />SIZE & REINF, <br />en <br />C%Q <br />0 <br />to <br />g <br />Q <br />�7 <br />dLU <br />W <br />O t <br />0 <br />aV- o <br />s w <br />cM1r <br />x <br />y o eo <br />m <br />iv Y <br />3: <br />m"-� <br />� N CSi A <br />E <br />d L,7 <br />0 <br />4.,tz0W/V 1110 <br />S <br />14 <br />0 <br />L O¢ 4 <br />u OFESStO�*��� <br />To the best of the Engineer's knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers <br />signature and seal. <br />F- <br />4 <br />co <br />N <br />A <br />IA <br />kA N C <br />Q <br />46 LL <br />J <br />LL <br />rqu.u- OW <br />m c a <br />a$ <br />O <br />N — <br />co <br />z <br />m WW <br />� N Z d J <br />VILWQj <br />,^ <br />N <br />OU 0 N <br />Z <br />W <br />❑❑ <br />z 6� <br />z <br />a <br />d YY <br />z <br />� <br />co <br />ate1 <br />c.„ <br />0`U <br />kN <br />c d <br />a <br />U <br />C <br />0 <br />W <br />M <br />i <br />;= <br />`e S <br />a <br />t <br />a <br />Q <br />E <br />m <br />U <br />u�0 <br />� <br />z <br />OE <br />O <br />I. <br />a <br />°d <br />U <br />d <br />L <br />fV <br />_ <br />O8 <br />< <br />ox <br />moo <br />f K <br />ZZ <br />Z <br />J- <br />co J <br />w. <br />r?m <br />aZ <br />i� <br />W <br />�LL <br />11 <br />mi <br />Oi <br />c <br />> d' <br />I— <br />d1 <br />C7 <br />N <br />GC> <br />N-- <br />cQ <br />>, <br />M <br />00 <br />O�O <br />y- <br />C Co11411 <br />M <br />D- <br />O <br />O <br />00 <br />•— <br />00 <br />C 04 <br />LO <br />F- <br />4.j O <br />oo O <br />M N <br />rn <br />LO <br />Q 1' <br />8 r <br />a <br />T <br />m <br />a, <br />cM *- <br />c <br />Z <br />E O <br />H <br />a <br />o <br />w <br />a o <br />JOB <br />NO : 22-12568-12561 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />SN 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.