ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles In laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to full the requirement of an outlet <br />every 24". The width of the sink or range Is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />t� <br />DUPLEX CONVENIENCE OUTLET <br />1 <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />VIM <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />13 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />f o <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />—� <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />;O� <br />EXHAUST FAN/LIGHT COMBINATION <br />�D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PEg <br />PUSH BUTTON SWITCH (OPTIONAL) <br />F0 <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />JQ <br />ELECTRIC PANEL <br />_ t <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />3" VTR <br />AIL <br />I <br />I <br />i <br />I <br />t I <br />I I <br />I I <br />LAV 1`1 <br />_I I <br />L TUB/ <br />W/C SHOWER <br />MVA <br />3" VTR <br />AIL <br />I <br />I <br />I <br />I <br />I <br />OPT <br />LAV <br />ILAV <br />I <br />I <br />u W/C <br />SHOWER <br />STUDOR <br />VENTq II Y11 DBL SINK <br />L W/ DISP. <br />W/C <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC <br />TO BE VERIFIED WITH PLUMBER <br />LOAD CALCULATIONS <br />Unit -C- (1624) <br />SQ. FT. AT 3 WATTS / SQ. F.T. <br />1625 S.F. <br />4875 <br />SMALL APPLIANCE CIRCUITS AT 1500 WATTS <br />3 <br />4500 <br />LAUNDRY CIRCUITS AT 1500 WATTS <br />1 <br />1500 <br />SUBTOTAL: 10875 <br />DISHWASHER AT 1200 WATTS <br />1 <br />1200 <br />DISPOSAL AT 960 WATTS <br />1 <br />960 <br />WATER HEATER AT 5500 WATTS <br />1 <br />5500 <br />DRYER OUTLET AT 5000 WATTS <br />1 <br />5000 <br />AIR HANDLER UNIT AT 1200 WATTS <br />1 <br />1200 <br />RANGE AT 8000 WATTS <br />1 <br />8000 <br />MICROWAVE AT 1200 WATTS <br />1 <br />1200 <br />LOAD WATTS <br />0 <br />.QTHER <br />OTHER LOAD WATTS <br />OTHERLOAD W TTS <br />SUBTOTAL: 23060 <br />TOTAL: 33935 <br />1st 10KWat1 0% <br />10000 <br />BALANCE OF WATTS AT 40% <br />9574 <br />AIR CONDITIONER WATTS AT 100% <br />1 <br />7104 <br />HEAT PUMP WATTS AT 100% <br />0 <br />HEAT PUMP & SUP. HEAT WATTS AT 65% <br />5200 <br />TOTAL: 31878 <br />LOAD WATTS --- 240 VOLTS <br />AMPS: 133 <br />PROVIDE 150 AMP SERVICE <br />Optional Overhead Service 200A <br />Same As Underground Indoor Panel <br />150 Or 200 Amp Service Center <br />NEMA 1 <br />2fx1 AMP <br />\ TGO \IA 1.1 <br />1 kO-200 Aly(P I I T /—Serial Cable <br />3R <br />Power Co. Feed --- 1-1 I. #4 Solid COPPER Ground <br />Intersystem Bonding <br />Termination Per <br />NEC 08, 250.94 5/8" Galvanized Driven Ground <br />Rods at least 6' apart <br />Typical 150-200 Amp Electrical Riser Diagram <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF <br />THE NFPA 70 - 17, LOCAL CODES AND THE LOCAL POWER CO. <br />C.O. <br />DB & GFI TO <br />BE ALIGNED <br />VERTICALLY <br />OUTDOOR LIVING <br />INSTALL LIGHT <br />� n <br />�`y��> <br />ROUGH -IN <br />FOR OPT. <br />FAN/LIGHT <br />GFI <br />' <br />ern <br />/----- U--- I <br />DINING <br />KITCHEN 1 <br />/ FI o <br />i <br />GFI <br />SWITCH FOR <br />DISPOSAL IN CAB <br />UNDER SINK <br />GREAT ROOM <br />/^ROUGH -IN\ <br />FOR OPT. <br />FAN/LIGHT 1 <br />I <br />1 / <br />TRY I, <br />'HT AS 0 <br />R SPECS <br />I <br />I u <br />I <br />I <br />I <br />I <br />rGF-L — <br />1UPSTAIRS IG <br />•4" <br />``\` <br />LW.H, <br />.F. <br />1 <br />\ 0 <br />I <br />I <br />I <br />GARAGE <br />I <br />GARAGE <br />LIGHT AS <br />PER SPECS <br />GARAGE <br />DOOR <br />GFI <br />r-----------------i <br />I <br />I <br />I <br />I <br />J <br />I <br />I <br />10 Z <br />I <br />IQ a <br />I <br />I0 Q <br />I <br />Z� <br />F- <br />I <br />I Icr W <br />LU <br />I <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS <br />DISCONNECT <br />1ST ELECTRICAL — UNIT—C 1624 <br />SCALE: Xa"=V-0" <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE <br />RANGE HOOD PER <br />SPECS <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />2ND ELECTRICAL — UNIT—C 1624 <br />SCALE: Y,"=1'-0" <br />r� <br />,. A CV <br />`� <br />c <br />Z <br />7 W <br />�Lo <br />a <br />IZ F o <br />— �co>< <br />N A O <br />• � 'Q O l0 <br />d <br />y os<c <br />a A 7 <br />f, <br />Co <br />N t< <br />aCo <br />o <br />ej <br />w <br />N <br />N <br />N <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />f <br />E <br />cgi 8 <br />Li <br />LQo <br />� �c �� <br />O <br />* <br />to <br />IA <br />11 <br />f� r 0 J <br />M v *6 LL <br />Q1 J <br />m LL LL w a <br />Y <br />= <br />CM �0� 0 <br />Wrn°�pjO' <br />m <br />Z <br />d F- <br />Nz G <br />ZOv <br />N <br />W <br />W <br />Z t3 c%1 <br />z m <br />13 <br />N <br />z <br />CD 0 <br />� <br />10 <br />f6 <br />� <br />W <br />U <br />OW <br />V)C) <br />r~ <br />w <br />z <br />A <br />c <br />a <br />ts, <br />14 <br />o <br />CD <br />N <br />w <br />Z <br />M <br />J <br />o� <br />Q <br />E <br />E ° <br />30 <br />UU <br />O( <br />Z <br />d E <br />N <br />p <br />a* <br />K 5 <br />wS <br />� <br />o <br />N 5: <br />ai <br />ott <br />a� <br />Z <br />Y <br />V, J <br />ai <br />i ai <br />22 <br />�� <br />ZZ <br />ao <br />W <br />a <br />v 38 <br />ww <br />FG <br />J <br />� <br />of <br />J=5�5 <br />�� <br />° <br />oa <br />0 <br />CCd <br />T <br />ECD <br />A <br />'S <br />�-- <br />T— <br />c <br />O <br />M_ <br />nCID <br />mUco <br />_ <br />O <br />O <br />_ <br />_ <br />: <br />000 O <br />LO <br />c <br />9 <br />cci CN <br />pOj <br />qt <br />tT e- <br />Ln <br />oo <br />CV <br />000 N <br />M r- <br />r <br />o <br />E <br />Z <br />0 <br />E 0 <br />m <br />Z <br />c <br />a. <br />E <br />U _j <br />Q 0 <br />JOB <br />NO: 22-12560-12553 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />15 <br />