Laserfiche WebLink
OWNER'S BATHROOM <br />SCALE: 3/8" =1'-0" <br />MIRROR <br />; j <br />I <br />N <br />\\ TOWEL BAR <br />I <br />ih <br />11t <br />` <br />71' <br />I <br />4-I <br />9 <br />o <br />� .ILO <br />1 <br />j <br />Li <br />rn <br />BATHROOM 2 <br />SCALE: 3/8" = V-0" <br />STAIR DATA: <br />18 RISERS @ 7.153" <br />17 TREADS @ 10" <br />TOTAL RISE = 10'13/4" 42" KNEE WALL <br />TOTAL RUN=14'-2" WITH 1x8 CAP & <br />CASING (AT 2nd <br />FLOOR ONLY) <br />3/4" PLYWOOD <br />DECKING <br />F. FL. <br />------------------- <br />18 <br />17 � \ <br />16 <br />15 <br />14 <br />- 13 <br />12 <br />10 <br />8 <br />F. FL. <br />is <br />5 <br />2x STRINGERS <br />FILLED CELL LEGEND <br />N CONT. FILLED CELL FROM FOUNDATION TO 2ND <br />FLOOR <br />® FILLED CELL BELOW 2ND FLOOR (DOWEL INTO <br />LINTEL) <br />® FILLED CELL ABOVE 2ND FLOOR (DOWEL INTO <br />BOND BEAM) <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20X26 <br />184X254 <br />S.H. <br />13 <br />20X38J <br />18}X37J <br />S.H. <br />14 <br />20X501 <br />184X50 <br />S.H. <br />15 <br />20X63 <br />18JX624 <br />S.H. <br />16 <br />20X72 <br />184X71} <br />S.H. <br />11­12 <br />271/4X26 <br />26X254 <br />S.H. <br />i H3 <br />27 114 X 38 J <br />26 x 371 <br />S.H. <br />1 H4 <br />27 J X 50'i <br />26 x 50 <br />S.H. <br />1H5 <br />27 JX 63 <br />26 X 62 1/2 <br />S.H. <br />1H6 <br />27JX72 <br />26X711/2 <br />S.H. <br />22 <br />37 J X 26 <br />36 J X 25 1/2 <br />S.H. <br />23 <br />37 J X 38 i <br />36 J X 37 3/4 <br />S.H. <br />24 <br />37 J X 50 J <br />36 J X 50 <br />S.H. <br />25 <br />37 J X 63 <br />36 J X 62 1/2 <br />S.H. <br />26 <br />37 J X 72 <br />36 4 X 71 1/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 4 WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 4 X 25 } <br />S.H. <br />33 <br />54 X 38 J <br />52 4 X 37 J <br />S.H. <br />34 <br />54 X 501 <br />521 X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 } X 62 J <br />S.H. <br />36 <br />54 X 72 <br />52 } X 71 } <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />(2) 2x8 w/ 1/2" <br />FLITCH HEADER <br />SLOPE CEILING TO <br />MATCH STAIR RISE <br />F. FL. <br />,,,-CONT. <br />HAND RAIL <br />TYPE STAIR SECTION. <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H 1 <br />(2) - 2X6 #2 SYP W/ 1/2' <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) -1 3/4" X 11 1/4 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) - 1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2950 <br /><e> <br />LVL 2.0E Fb=2950 <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2950 <br />(2) - 2X4 #2 SYP W/ 1/2" <br />Follow Q/S4. See Plan for <br />RAG <br />FLITCH PLATE <br />Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />F. FL. <br />DRYWALL <br />1 1/2" MIN. CLEARANCE <br />BLOCKING AS <br />REQUIRED <br />2x4 #2 SYP. P.T. THRUST <br />BLOCK W/(2)-1/4"x 31/2" <br />TAPCONS HANDRAIL DETAIL <br />3" FROM EA. END. <br />SCALE: 3" =1'-0" <br />1 1/4" TO 2" DIA <br />HANDRAIL NO <br />LESS THAN 34" <br />NOR MORE THAN <br />38" ABV. TREAD <br />NOSING <br />METAL HANDRAIL <br />BRACKET <br />Stair and Railing General Notes <br />Stairway construction shall conform to the FBC Residential 7th Edition (2020) sections R311.7, R312 <br />and R302.7. <br />Riser height: <br />The riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading <br />edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by <br />more than 3/8 inch. <br />Tread depth: <br />The tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the <br />vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The <br />greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Winders: <br />Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the <br />foremost projection of adjacent treads at the intersections with the walkline. Winder treads shall have a tread <br />depth of not less than 6 inches at any point within the Gear width of the stair. <br />Nosings: <br />Nosings at treads, landings and floors of stairways shall have a radius of curvature at the nosing not greater than <br />9/16 inch or a bevel not exceeding 1/2 inch. A nosing projection not less than 3/4 inch and not more than 11/4 <br />inches shall be provided on stairways. The greatest nosing projection shall not exceed the smallest nosing <br />projection by more than 318 inch within a stairway. <br />Handrails: <br />Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more <br />risers. Handrail height measured vertically from the sloped plane adjoining the tread nosing, or finish surface of <br />ramp slope, shall be not less than 34 inches and not more than 38 inches. Handrails for stairways shall be <br />continuous for the full length of the flight, from a point directly above the top riser of the flight to a point directly <br />above the lowest riser of the flight. Handrail ends shall be returned or shall terminate in newel posts or safety <br />terminals. Handrails adjacent to a wall shall have a space of not less than 1112 inches between the wall and the <br />handrails. <br />Grip -size: <br />Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater <br />than 2 inches or provide equivalent grasp -ability in compliance with Section R311.7.8.3. <br />Guards: <br />Guards shall be provided for those portions of open -sided walking surfaces, including stairs, ramps and landings, <br />that are located more than 30 inches measured vertically to the floor or grade below at any point within 24 inches <br />horizontally to the edge of the open side. Required guards at open -sided walking surfaces, including stairs, <br />porches, balconies or landings, shall be not less than 36 inches in height as measured vertically above the <br />adjacent walking surface or the line connecting the leading edges of the treads. Required guards shall not have <br />openings from the walking surface to the required guard height that allow passage of a sphere 4 inches in <br />diameter. <br />Under -stair protection: <br />Enclosed space under stairs that is accessed by a door or access panel shall have walls, under -stair surface and <br />any soffits protected on the enclosed side with 1/2-inch gypsum board. <br />VERIFY <br />AC PAD LOCATION OF <br />A/C PAD <br />HB <br />14nr <br />EXTERIOR 2ND FLOOR <br />BEARING WALL SCHEDULE <br />HEIGHT <br />STUD <br />SPECIES <br />SPACING <br />SPF #2 <br />8'-0" <br />2x4 <br />SYP #2 <br />16" O.C. <br />SPF #2 <br />9'-0" <br />2x4 <br />SYP #2 <br />16" O.C. <br />SPF #2 <br />2x6 <br />SYP #2 <br />16" O.C. <br />Mill. <br />... <br />OUTDOOR LIVING <br />■11 <br />.". <br />... <br />... <br />■n <br />A.loll <br />■i11 <br />■w <br />::: <br />• <br />■iI. <br />• <br />• <br />will <br />:,II <br />■■� <br />:■i <br />II <br />..@ <br />ZINN <br />Bill <br />slow <br />►i►i <br />r-IN <br />ll' <br />!i!i <br />we <br />��•; <br />44 <br />Q!j <br />is <br />►41 <br />O•i <br />•�!� <br />6i!4 <br />DINING <br />KITCHEN <br />4•i <br />Lu <br />0121 <br />0►i <br />•:: <br />•,►� <br />D/W DISPOSAL <br />04 <br />!••• <br />•i i <br />►,►, <br />% <br />FLRG. LINE Jill <br />Nil <br />!i!i <br />•i►i <br />!�•, <br />�.►� <br />e <br />; <br />•.►. <br />►;► <br />!.•. <br />'.►. <br />►�►� <br />0111 <br />. <br />►:.: <br />! <br />9S <br />N04 <br />-�'�• <br />04 <br />►�'� <br />ii <br />, • • <br />RA ROOM <br />-©6! <br />► 1 <br />!.•. <br />►W <br />i :• <br />►•.� <br />••'� <br />:': <br />•1i'• <br />:0 <br />!;'; <br />a <br />4ti <br />01 <br />*NO UPLIFT* <br />�' <br />sf a, <br />•i0 <br />•.►. <br />® <br />• ► <br />!�.� <br />FOYERA <br />.. <br />:4 <br />\ <br />�- <br />►.�� <br />•i�i <br />!�!� <br />:•J� <br />•�!� <br />•'�� <br />•;•; <br />:.:.... <br />N <br />;.;. <br />• • <br />•Oi <br />.- <br />�. <br />i <br />••�! <br />.. <br />♦. • <br />I <br />BUILDER TO <br />lit <br />Nowl <br />MEN <br />PROVIDE <br />011: <br />APPLIANCE <br />!4!404 <br />...PROTECTION <br />WHEN <br />REQUIRED PER <br />& <br />;s►, <br />::1 <br />to <br />;05 <br />•�•; <br />••�. <br />::: <br />110� 1 -CAR GARAGE <br />::: <br />►�►i <br />►► <br />OWN <br />ENTRY <br />.. <br />•i•; <br />..1 <br />• ::� <br />.. <br />ZZ <br />SON <br />►.►. <br />1 <br />ME I <br />•i' <br />.. <br />:E <br />•:0 <br />NN <br />■■1 <br />go <br />►.. <br />N <br />• <br />•► <br />5MEN <br />•••% <br />: _ <br />:;i <br />•i►; <br />' <br />S4 <br />III <br />�..; <br />IIII <br />STONE <br />VENEER <br />5 <br />1ST FLOOR PLAN - UNIT-C 1624 <br />SCALE: Y"=V-0" <br />c <br />* WHEN THE TOP OF WALL IS GREATER THAN 9'-0", THEN AT <br />EACH EXTERIOR CORNER WITHIN THE 4'-0" END ZONE, THE <br />STUDS WILL BE DOUBLE STUDS @ 16" O.C. OR SINGLE STUDS <br />@ 12" O.C.' <br />THIS /S ONLY USED WITH PLASTER OR STUCCO EXTERIOR <br />FINISH <br />** WALL SHEATHING 15/32" EXPOSURE 1 OR EQUIVALENT. <br />REFER TO SHEATHING SCHEDULE FOR ATTACHMENTS** <br />2ND FLOOR PLAN - UNIT-C 1624 <br />SCALE: Ya"=1'-0" <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE"C" <br />0 <br />+29.7 / -32.2 <br />© <br />+29.7 / -39.7 <br />© <br />+28.3 / -30.8 <br />CD <br />+28.3 / -37.0 <br />OE <br />+26.6 / -29.1 <br />OF <br />+26.6 / -33.5 <br />GO <br />SEE SN SHEET (H SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />+29.7 / -39.7 <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic, crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />•-MASONRY <br />1......... : • <br />.... <br />MASONRY PARTY WALL <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO UPLIFT <br />CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />1ST FLOOR <br />2ND FLOOR <br />664 S.F. <br />970 S.F. <br />TOTAL <br />1634 S.F. <br />GARAGE <br />246 S.F. <br />LANAI <br />108 S.F. <br />ENTRY <br />98 S.F. <br />TOTAL SQ. FT. <br />2086 S.F. <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 R-19 KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />OG.C. TO COORDINATE PLUMBING TO AVOID <br />CONFLICT WITH STRUCTURAL WD. COL. <br />Q <br />� <br />c <br />0 <br />Z <br />Q <br />o W <br />.11=o <br />c Iowa,, <br />'-o°Ose <br />� boa <br />4 r N Y <br />c w <br />3 /v <br />2 <br />' <br />'sue•-� <br />w a. <br />Cc E <br />Cc <br />d IJ <br />0 <br />�� <br />U u. <br />v <br />OFESSJON <br />I'7II/111111111't����``` <br />To the best of the Engineers knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />Is <br />E <br />MN 8 <br />0 <br />� -2ch <br />1 N <br />w <br />('19 <br />n <br />J <br />LL <br />Z <br />a �Sn <br />W <br />lag <br />�j�CP m <br />W <br />. <br />0 <br />ZN <br />06 <br />W <br />N <br />z � <br />z <br />L f; <br />N <br />o <br />- <br />.O <br />o <br />$ <br />to <br />to <br />c <br />� <br />w Is <br />o[ <br />Q N <br />E <br />ll <br />M <br />E <br />Z <br />� <br />fog <br />Zo <br />Q <br />W <br />1. <br />8 <br />o <br />N <br />0 <br />o <br />�Z <br />� <br />� <br /><o <br />mo <br />Z <br />� <br />N J> <br />N ? <br />8 <br />U <br />az <br />W <br />3 <br />LL <br />yz <br />ry5 <br />=S <br />i. <br />� <br />WJiI <br />3 <br />c <br />T <br />oIN <br />> <br />~ <br />cNa <br />T <br />Nil <br />E <br />m <br />CIDT_ <br />T- <br />C m <br />U- <br />o <br />00 <br />CN <br />t=- <br />O <br />CN <br />10 <br />LO <br />cap <br />= <br />t` <br />4-1 <br />I <br />M N <br />t p CN <br />Ca <br />CA <br />CN <br />LO <br />00 <br />N <br />00 N <br />M T <br />•- <br />o <br />E <br />Z <br />t;) <br />E O <br />c <br />co <br />E .. <br />c <br />JOB <br />NO: 22-12560-12553 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />5 <br />