Laserfiche WebLink
CORNER OF <br />HOME <br />GARAGE SIDE <br />Backer and Filler Block Dimensions <br />BCI Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" or 7/8" <br />5000s 1.8/1.7 <br />wood panels <br />Two 3/4" wood panels or 2 x <br />1-1 /8" or two 1 /2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1 /2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2 x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONST:Z111, <br />(Not required if both load) <br />Filler bl; <br />1/8" gap—i <br />r <br />,2 <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4) Place joists together and nail from each side with 2 rows of 10d nails <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite <br />OF THE JOIST ASA REQUIRED LEAVING Ya" GAP @ TOP sides by 6". <br />DOUBLE JOIST CONNECTION <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />* Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />wall or beam below.* <br />consideration. Check <br />local building <br />code for appropriate <br />details in <br />One 10d box <br />areas=20 of high <br />or=20 sinker <br />lateral load. <br />nail each side <br />10'-0" <br />at bearing. <br />TANK -LESS W/H <br />T-0" <br />STUB -OUT FOR <br />GAS METER 0 <br />O <br />CV <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"*'ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY"* <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />7'-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />1) SIMPSON HTS20 OR 3 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR 4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-l" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'-4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Squash block / <br />(2x4 minimum) —J <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />NO HOLES (EXCEPT <br />KNOCKOUTS) ALLOWED <br />IN BEARING ZONES —t <br />DO NOT cut, notch <br />or drill flanges <br />Boise Joist Blocking <br />Use 3" (1 Od) nails at 6" o.c. <br />7: Provide adequate bearing <br />for each lapped joist. <br />10d nails SECTION @ INT. BRG. WALL <br />N.T.S. <br />MINIMUM SPACING = 2x GREATEST <br />D DIMENSION OF LARGEST HOLE <br />(see table below) (KNOCKOUT EXEMPTS) D <br />(see table below) <br />FILL CELL STD. 900 HOOK BOND BEAM <br />to <br />w <br />CONT. #5 > STD. 90° <br />BAR I HOOK <br />IV <br />BOND BEAM STEP <br />CONT. #5 <br />BAR <br />— #5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />1 <br />SEE PLAN FOR REQ'D � � � � .-�.-� �,--PLYWOOD FLOOR <br />COLUMN AND y __ SHEATHING PER PLAN <br />CONNECTION �C <br />` TJI TO BE CUT TO ALLOW <br />,FOR BLOCKING/TJI <br />MASONRY WALL OR <br />- ] > INTERIOR BRG. WALL <br />� . � � . \•\` \., � TJI PER PLAN <br />r <br />OTHERWISE SOLID <br />IBLOCKING TO MATCH <br />Solid block all posts from # OF 2nd FLOOR <br />above to bearing below. STUDS <br />SECTION @ INT. BRG. WALL <br />N.T.S. <br />1/8" min. 2" min. <br />} Small ap <br />2" max. g 4" max. Web Stiffener Fastener Schedule_ _J <br />I Joist Bearing Location <br />- -- <br />Series _ 1 Depth End I_ Intermediate <br />A, ® 9--1/2" 2-8d � 2-8d <br />— - - BCI 5000s 11-7/8_" 2-8d 3-8d <br />A. _ <br />14" 2-8d <br />Clinch nails 9-1/2" _ 2_8d _ 2-8d <br />when �BCCI <br />16000s® 11-70' 2-8d 3-8d <br />possible 6500s® 14" 2-8d 5-8d__ <br />�- <br />_ V I {._ 16 2-8d 6-8d <br />117/8" 2-8d 3-8d <br />_- BCI 60s® 14" __ 2-Sd 5-8d <br />Tight fit `` 16" 2-8d -6-8d <br />4" max. BCI 90s 1114"8, _ 16d 3-16d <br />2x4/PI ood/OSB web stiffener \ 2' min. ®5-16d <br />required when indicated or 16 �6_-16d 6-16d <br />- Hangers with side nailing. <br />- Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />- Birdsmouth cuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 pif max. along bearing wall <br />Required on interior walls: - for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration.— <br />tst UU I ANTWntNt IN CANTILEVER <br />THE WEB. PROVIDE AT <br />LEAST 3" OF CLEARANCE <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 112' <br />NOTES: <br />DO NOT CUT HOLES <br />LARGER THAN 1Yz" <br />ROUND IN <br />CANTILEVERS. <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. %" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE 1Y2" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />�When joists meet over wall, provide <br />1 3/4" minimum bearing for each. <br />SIMPS( <br />w/(22)' <br />NAILS 1 <br />5/81 <br />THRU <br />BOLT <br />SIMPS( <br />w/(22) <br />NAILS 1 <br />R TRUSS <br />'OP PLATE <br />I.0 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />VIIN. EMBEDMENT <br />SCHEDULEFOR <br />AND QUANTITY <br />)IFFASTENERS <br />TYPICAL SIMPSON META12 / <br />Plumbing META12 TSS INSTALLATION <br />Joist <br />I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S <br />Backer block (12" wide min.) <br />Nail with 10-10d nails. <br />Install tight to top flange. <br />Joist hanger <br />\ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gap <br />I <br />Backer Block 1 <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4%2" gap at bottom of top <br />flange. flange. <br />eb stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />J - requirements <br />0.6 X Joist <br />t i � `depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />�• . A ._ <br />FINISH GRADE <br />SLEEVE THRU STEMS <br />SEE PLAN FOR--'•• a .. • <br />FOUNDATION INFO ' e <br />STEM FOUNDATION <br />GRADE <br />REINF. SEE PLAN <br />A/C CHASE 4" PVC <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />LOCATION OF <br />�\ SECOND H10A <br />(WHEN <br />SIMPSON H10A REQUIRED) <br />w/ (18)10d x 1 1/2" <br />NAILS <br />UPLIFT =1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" v <br />CENTERED @ PIPE <br />PENETRATION <br />12" BELOW <br />GRADE <br />OMM* <br />I ow, <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />e <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE VERTICAL THRU FND. <br />TOP (2) #5's x 4' 0" <br />CENTERED @ PIPE <br />PENETRATION <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />I \° • / <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION PLUMBING LINE <br />a. e <br />-- G — eo Al ev L <br />a <br />G Q — <br />° < e — <br />A--- Tr <br />o <br />SEE FND. PLN. <br />01 SIZE & REINF. <br />0 <br />N <br />0 <br />`e``�ttttlilli►i�s�i <br />%,,E WKO�'1� <br />��,�� , •' E, N S ' .'S �i <br />50 <br />pE7 ••# <br />AVAV <br />'v''. „ �t <br />rf11J <br />'E O .'. <br />r ; � ln4 41 <br />9040� <br />To the best of the Engineer's knowledge. Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />a <br />g <br />8 <br />V <br />0- <br />LL <br />�rn'�iLL <br />a <br />I*rn <br />� <br />z <br />0 <br />N ui <br />0 - LL a <br />y co •a 1 : <br />CO LLii wa ai <br />Z <br />m�Nqq�qq��� <br />t <br />19O <br />AC,G X O � <br />a a <br />= <br />ILW <br />Mz coo <br />= <br />W <br />❑ ❑ ❑ <br />0 <br />z N <br />z � <br />z <br />J <br />a <br />� <br />N <br />z <br />(D4-1 <br />(� <br />LL <br />w <br />V <br />� <br />� <br />In <br />C <br />w <br />'— — E� <br />8 <br />V� <br />_ � <br />'D <br />c <br />__ <br />N <br />O <br />co <br />co6 <br />w <br />Z_Z <br />J <br />E <br />2 <br />o�g <br />zo <br />E OU <br />~ 6 <br />oa <br />w� <br />Z <br />gco <br />Z <br />E` <br />�o <br />�o <br />Cn C <br />o <br />i LL <br />z <br />Cn <br />UO <br />>z_ <br />= O <br />U <br />_ <br />W` <br />J <br />CD <br />_�� <br />Oil <br />O <br />>Ln <br />� <br />iG <br />rn <br />c <br />J <br />� <br />m <br />CCAI <br />U <br />CEO <br />mo <br />CV <br />/ram� / <br />V/ <br />'o <br />2 CD <br />1 <br />f_ <br />.= <br />2 L0 <br />r <br />001. N <br />r <br />E <br />M <br />CV <br />CV)z <br />Z <br />C <br />E O <br />d <br />a <br />U � <br />¢ p <br />� <br />JOB <br />NO : <br />21-2028 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />SN 1 <br />