ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES. - <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2"AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.WEATHERPROOF DUPLEX OUTLET <br />P. <br />G.F.I. GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />13 THREE-WAY SWITCH <br />4 FOUR-WAY SWITCH <br />$R RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />P.C. <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />® ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />49 PUSH BUTTON SWITCH (OPTIONAL) <br />F0 PUSH BUTTON SWITCH - DOOR BELL <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB TELEPHONE/USB (OPTIONAL) <br />® TELEVISION (OPTIONAL) <br />®2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />ELECTRIC METER <br />owl ELECTRIC PANEL <br />_ DISCONNECT SWITCH <br />�� <br />ROUGH -IN FOR OPT. CEILING FAN <br />oj�J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J OPT. CEILING FAN <br />GD (1) PHONE LINE, (1) DATA PORT <br />150A/200A INDOOR <br />PANEL CENTER <br />00 k14 copper to tights & outlets <br />NEMA 1 <br />150 AMP/ <br />10 k12 Copper to 20 amp cios <br />200 AMP <br />k10.2 copper to WH <br />01 k10.3 copper to Dryer <br />i�-,T <br />200 amp <br />150 amp <br />UNDERGROUND Dis <br />POWER CO. FEED---_ <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />or 4/0 SER Alu <br />Bare Cu Ground <br />NEC 14, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER CO. <br />V <br />t <br />GFI <br />WP <br />GFI <br />DISC. <br />OACPA <br />3° <br />V <br />KIT <br />UHTO EN � <br />�FNT <br />ti <br />4" <br />rV` <br />C <br />PLUMBING RISER_ <br />NOTE: PLUMBING RISER IS SCHEMATIC TO SCALE: NTS <br />BE VERIFIED WITH PLUMBER <br />W W <br />\ <br />\ <br />\ <br />FAMILY ROOM <br />�1 \ <br />\ <br />10 <br />G�--- - ----------------------- <br />\ ROUGH -IN FbR \ <br />\ OPT. CLG. FbN/ LIGHT \ <br />\ PRE -WIRE <br />I � <br />I \ <br />rl <br />I <br />AE <br />k / <br />OW� R'S <br />W ITE <br />1 ROUGH -IN FOR <br />I OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />I <br />H.B. <br />W.I.C. ):�' -- — <br />i <br />a W (i - r 7(j� <br />0 IrIIa - I DW I <br />� I C. $WI CH <br />GR <br />fpR-bis�S <br />+ 1 <br />RAGE <br />\ <br />PENDANT AS <br />PER SPECS ---- <br />c <br />T-0" <br />'— — — —J-1 GFI <br />'1 :SINK w/:� -- <br />' DISP <br />I � I <br />I <br />—> <br />i <br />I <br />GTIu ` . I - --I -' <br />O DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />C.M <br />i mar / <br />ROUGH -IN FOR <br />OPT. CLG. WN/ <br />LIGHT PREIWIRF� <br />BEDROOM 2 <br />S.D <br />VP <br />50IFF-- <br />1 I - <br />H4 <br />I <br />ENTRY <br />I <br />WP <br />,GFI I <br />FAMILY ROOM <br />�1 \ <br />\ <br />10 <br />G�--- - ----------------------- <br />\ ROUGH -IN FbR \ <br />\ OPT. CLG. FbN/ LIGHT \ <br />\ PRE -WIRE <br />I � <br />I \ <br />rl <br />I <br />AE <br />k / <br />OW� R'S <br />W ITE <br />1 ROUGH -IN FOR <br />I OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />I <br />H.B. <br />W.I.C. ):�' -- — <br />i <br />a W (i - r 7(j� <br />0 IrIIa - I DW I <br />� I C. $WI CH <br />GR <br />fpR-bis�S <br />+ 1 <br />RAGE <br />\ <br />PENDANT AS <br />PER SPECS ---- <br />c <br />T-0" <br />'— — — —J-1 GFI <br />'1 :SINK w/:� -- <br />' DISP <br />I � I <br />I <br />—> <br />i <br />I <br />GTIu ` . I - --I -' <br />O DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />C.M <br />i mar / <br />ROUGH -IN FOR <br />OPT. CLG. WN/ <br />LIGHT PREIWIRF� <br />BEDROOM 2 <br />S.D <br />VP <br />50IFF-- <br />1 I - <br />H4 <br />I <br />ENTRY <br />I <br />WP <br />,GFI I <br />kW IRRIGATION <br />GFI @ 44" A.F.F. <br />-- <br />F -2­C--x-2'-6'44'-Q'j'— <br />W/ #5'S E.W. <br />— <br />A A <br />, (3) <br />I�i69-� I I <br />I <br />II <br />I <br />I n_y,l <br />I 1I I <br />I <br />I <br />I <br />I <br />� <br />I <br />(GARAGE <br />GARAGE <br />DOOR <br />\ <br />LIGHT AS <br />I GFI <br />\ <br />\ PER SPEC <br />% <br />GFI F. <br />- <br />2 �AR 5 <br />A. <br />�Z <br />Cf�1�1rf�CJ"ll l <br />w <br />I <br />� Z <br />R a <br />I <br />Q <br />I <br />0U <br />I <br />>- C <br />I <br />IX <br />I <br />> w <br />L — — — — — — — — — — — — <br />GFI @ 44" <br />Ak A.F.F. <br />\ S.D <br />D.D I \ <br />EDROOM 4 <br />ROUGH -IN FOR (j 1 ROUGH -IN FOR <br />PT. CLG FAN <br />LLIIGHT PRE W R/EB E D F OO M 3 OPT. CLG. FAN/ <br />LIGHT PRE-1Q4$£x 2'-6" x 1'-0" <br />W/ (3) #5'S E.W. <br />VERIFY METER LOCATION <br />WITH BUILDER <br />ELECTRICAL PLAN - ELEV-B1 I <br />SCALE: )4 "=1'-0" <br />N <br />N <br />cp <br />N <br />0 <br />To the best of the Engineer's knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and <br />seat is only for <br />the structural engineering portions of the drawing pages beating <br />Engineer's signature and seal. <br />W <br />Q <br />O N Fj <br />J <br />LQ �n�Y <br />aNi 6 <br />�D� <br />J� <br />4 <br />yMRw <br />LL LL <br />w <br />N <br />w <br />Z <br />L N O <br />000 <br />O0 <br />W�QjO' <br />�g� <br />? <br />mop <br />d c <br />= <br />IL <br />N M Z <br />a <br />J y 0 <br />y <br />Z <br />6 0 <br />=i <br />W <br />000 <br />J — <br />a <br />N <br />N <br />— <br />z <br />U � <br />V) <br />c § <br />�V) <br />_ I <br />Lu <br />Of U A Yp <br />• <br />0 <br />N O <br />c <br />W <br />U- <br />`E o <br />zo <br />w <br />>. <br />go <br />itsK <br />H <br />a3(� <br />oa <br />oa <br />N <br />Q? <br />$ <br />ao <br />IL Z <br />¢uj <br />to <br />on CY <br />U <br />mo <br />ZLL <br />Z <br />y m <br />f W <br />�_ <br />ao <br />W <br />3 <br />IML 3 <br />U 3 <br />80 <br />�off <br />U <br />N W <br />�k <br />o <br />Ala <br />coo <br />� <br />zl6 <br />U 3 <br />O <br />—117 <br />to <br />>Ln <br />ui <br />0 <br />Ln <br />CN <br />• <br />U <br />C:) <br />m <br />U <br />CEO <br />W <br />0 <br />Z <br />N <br />T <br />o <br />CD <br />T <br />r <br />I <br />00 co <br />a) N <br />Lid <br />r <br />E <br />dam' <br />CN <br />C0 <br />Z° <br />Z <br />E <br />«? <br />cc <br />a <br />tJ 0 <br />v <br />c <br />JOB <br />NO: <br />21-2028 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />