My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6237 Back Forty Loop
Zephyrhills
>
Building Department
>
Building Plans
>
6237 Back Forty Loop
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 1:28:35 PM
Creation date
2/27/2025 11:19:55 AM
Metadata
Fields
Template:
Building Plans
Street #
6237
Location
Back Forty Loop
Contractor
Lennar Homes
Building Plans - Permit #
5933
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL NOTES: <br />ROOF PLAN (ELEVATION A <br />1 /411 = 1 1-011 <br />* G.C. VERIFY ROOF PITCH <br />ROOF PITCH VARIES PER SUBDIVISIONS (5/12 PR 5.9112) <br />IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ROOF <br />SLOPE REQUIREMENTS WITH TRUSS MANUFACTURER. <br />ROOF CRITERIA <br />- 12" OVERHANG U.N.O. <br />- PLUMB CUT FASCIA <br />- ROOF PITCH PER ELEVATION <br />- WINDLOAD CALC. PER ASCE 7-98 (VARIES BY LOCATION) <br />- SHINGLE LOADING <br />12ND FLOOR ROOF VENT CALL: <br />NOTE: VERIFY WITH GENERAL CONTRACTOR ALL ROOF VENT <br />LOCATIONS, QUANTITIES, AND SIZES. ROOF VENTS SHALL BE <br />INSTALLED FOR A MIN. OF VENTED AREA AS LISTED BELOW OR <br />EQUIVALENT SYSTEM PER F.B.C. 7TH ED. (2020) SECTION R806 <br />FORMULA = S.F. / 300 (1/300) * 144 (TO CONVERT TO SQ. INCHES) _ <br />NET SQ. INCH REQUIREMENT <br />ATTIC AREA = 1505 SQ FT <br />VENTILATION REQUIRED = 722.4 <br />VENTILATION PROVIDED AT RIDGE = 414 SQ IN <br />VENTILATION PROVIDED AT SOFFIT =1134 SQ IN <br />ATTIC VENTILATION <br />ATTIC VENTILATION TO BE IN COMPLIANCE WITH THE FLORIDA <br />BUILDING CODE 7TH EDITION (2020) RESIDENTIAL R806. <br />THE MINIMUM NET FREE VENTILATING AREA SHALL BE 1/150 OF THE <br />AREA OF THE VENTED SPACE. THE VENTILATED AREA MAY BE <br />REDUCED TO 1/300 PROVIDED THAT AT LEAST 40% BUT NO MORE <br />THAN 50% OF THE REQUIRED VENTILATION IS PROVIDED IN THE <br />UPPER PORTION OF THE SPACE TO BE VENTILATED. UPPER <br />VENTILATORS SHALL BE LOCATED NO MORE THAN 3 FEET MEASURE <br />VERTICALLY) BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE, <br />WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY <br />EAVE OR CORNICE VENTS. <br />CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN. <br />VALUES TO BE VERIFIED WITH MANUFACTURER SPECIFICATIONS) <br />RIDGE VENTS 18 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />* OFF -RIDGE VENTS - 138 SQ. IN. OF NET FREE AREA / UNIT <br />* SOFFIT VENTS 7 SQ. IN. OF THE NET FREE AREA / SQ. FT. <br />IF NOT ENOUGH VENTED SOFFIT IS PROVIDED DUE TO FIRE <br />PROTECTION, THE CONTRACTOR SHALL USE DECK -AIR OF OTHER <br />APPROVED MATERIAL TO PROVIDE SUFFICIENT IN -TAKE VENTILATION <br />* LOMANCO DECK -AIR - 9 SQ. IN, OF NET FREE AREA / FT. FOR SHINGLE <br />36 SQ. IN. OF NET FREE AREA / FT. FOR TILE <br />NOTE: <br />EXTERIOR WINDOWS, SLIDING DOORS AND EXTERIOR SIDE -HINGE <br />DOORS SHALL BE TESTED AND LABELED WITH A PERMANENT LABEL <br />PROVIDING TRACE ABILITY TO MANUFACTURER AND PRODUCT <br />MAR 2 5 2023 <br />Virtual Review Assist, IW <br />Plans Review completed and approved <br />for compliance with the 2020 FBC 7th Edition <br />by Debra Anne Klahr PX2300 <br />. <br />ca ° <br />N <br />(3)LQ^ <br />04 <br />o <br />V! <br />L <br />> O <br />Qua, <br />u <br />ti <br />V) <br />0 - <br />u a <br />C <br />C L <br />t O <br />2 O <br />'F- <br />O L o <br />G oQ <br />�i <br />•N <br />Udo <br />a <br />U <br />W QN <br />C <br />„ <br />oar <br />74� <br />a <br />V <br />N <br />N <br />O <br />N <br />N_ <br />L0 <br />0 <br />0 <br />z <br />W <br />0 <br />W <br />0 <br />z <br />a <br />0 LLI f!j W O <br />~ ~W WF-x xgY�zLU x <br />ZO0 LL0O_j0QcoXx-W0 <br />oOtRoomnz <br />Z0 Zd U)W WUX Q°oWW Loo W aV5 �Qa <br />LL <br />oQ o 0 o¢Z <br />QU_ a <br />� <br />>f <br />O <br />O <br />Z W <br />O� <br />S2 <br />0 M O <br />Q CO) <br />LO <br />z 0— U) <br />2 U) LL ti <br />z < W < U? <br />I—�CLM <br />O <br />Z U H <br />Z <br />W J O <br />O <br />O <br />mi 1q, <br />O <br />O <br />N Lo <br />LO'tt <br />10_ <br />CO 0 <br />O <br />0)O <br />L <br />r Q <br />0 <br />0 <br />0 <br />0 <br />0 <br />N <br />N <br />N <br />N <br />N <br />N <br />(� <br />O <br />O <br />o <br />N <br />z <br />O <br />U) <br />Of <br />W <br />to <br />N <br />(V <br />1R <br />i <br />LAST PLOT DATE <br />Z <br />zZ <br />¢w <br />z <br />w Woo <br />V VUU5 <br />�zj <br />O 0�o <br />Z <br />2 w=¢ <br />(D °° <br />ZOO <br />>_ OW <br />O az� <br />�z <br />ROOF PLAN A <br />a <br />z <br />z <br />W <br />CD <br />
The URL can be used to link to this page
Your browser does not support the video tag.