Laserfiche WebLink
rll�ll�llll ��ts,;u�l�w <br />) <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />in <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings wh r where stalled within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />Fff <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />4 <br />FOUR-WAY SWITCH <br />R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />—� <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />�P <br />PUSH BUTTON SWITCH (OPTIONAL) <br />�D <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />® <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />�M <br />ELECTRIC METER <br />Van <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />C� J <br />ROUGH -IN FOR OPT. CEILING FAN <br />��� <br />a <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />r J <br />OPT. CEILING FAN <br />G�) <br />(1) PHONE LINE, (1) DATA PORT <br />150A/200A INDOOR <br />PANEL CENTER <br />4 to lights & outlets <br />2 to appliances and GFI <br />0 to WH <br />to Range <br />to HVAC <br />200=4/0 in 2" Conduit <br />UNDERGROUND Dis <br />SERVICE BY POWER CO.—�� <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 17, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS — <br />U.C. OUTLET <br />SWITCH FOR <br />DISPOSAL <br />SPEC 3 & 4 KITCHEN <br />SCALE: Y4'=1'-0" <br />n <br />VTR 3" VTR IjI, <br />III,, 'I <br />�I I <br />I I <br />I I <br />I <br />I r I <br />3" VTR Ill- <br />I � I <br />I I I I I <br />I 1 I nit I t <br />3" <br />--------------------LAV <br />� <br />----CANRT---- • I I 1 2 I 1 <br />2" <br />I <br />I n I <br />/i> j TUB 3" <br />3t� <br />AC PAD I I I WC <br />WP DISC. j <br />GFI I j GFI <br />3" <br />r ^ �, HANSON <br />CIP-- - off I ALT I BOX <br />j I AC PAD I j - VP o <br />0 <br />-- I OWNER'S <br />�BRKFST. 2 <br />DINING ----- , <br />-- LIGHT AS -PER \ � � WP � � �� � � SUITE <br />I IL <br />BAT H' __ 3 <br />11 <br />/ in 5-0 OPT / -•. S.S. <br />SPECS " / \ <br />o <br />LIGHT AS PER - <br />• <br />SPECS • �/ / /G 3" VTR SINK <br />i <br />I <br />OPT. CLG. FAN/ <br />III C/0 <br />I <br />LIGHT PRE- <br />- 1 WIRE <br />I I <br />1 PENDANT r----------- <br />- LIGHT PER I WIC I I <br />SPECS RECEPT. FOR - I 2' <br />- -11 ALARM SYSTEM <br />�� <br />I t� <br />I I GREAT RM ; I _� " <br />DEDICATED GFI - I GFIII _ _ I I�____J 3" <br />3 <br />RECEPTACLE FOR - -- L_______ LAV <br />•_ ! FI I ROUGH -IN • r-- 2tt <br />HOOD PEMICROWAR SPECS RANGEVE I o Y I U.C. OUTLET FOR OPT. <br />WC <br />' I ZI - I l/ FAN/LIGHT S.D. 3„ <br />GF -- <br />O -- 0 3,t <br />,�, <br />I SWITCH FOR 1 OPT. CLG. FAN/ / <br />DISPOSAL I \LIGHT PRE -WIRE OPT. CLG. FAN/ <br />GFI - I - — / LIGHT PRE -WIRE <br />II <br />-- <br />4 BA 2 — <br />XGF10 PROVIDE PHONE /CABLE <br />I / 4" <br />"$ T+-�--+- <br />1!_-1yo" j I j �/ AND OUTLET AT TECH /1 BEDROOM 4 <br />`�- CENTER S.D. <br />r 3 - 0 M. PLUMBING RISER <br />CHdbP <br />-- r T L S - • L - - - - - - - - - - SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />I I I I I I I I I BE VERIFIED WITH PLUMBER <br />D I S I HI N I I I w 3 4 <br />-- Q T <br />I I I I j I I j <br />I I I I I I II I I I I '? S I H W <br />B L I <br />- AU ---------- <br />• • <br />o <br />GFI@44"-1OYf�i <br />H W.H. A.F.F. GFI @-------- <br />w Z 44" A.F.F. M <br />qp <br />�_°W <br />J - — I \ - <br />>Jm a - <br />_ w <br />J <br />w 0 aI S.D. S.D. <br />J . . O <br />\\ GARAGE � WP p� I <br />Lt- U LIGHT AS I I I ` OPT. CLG. FAN/ <br />w PER SPECS GFI I I I \ I I LIGHTPRE-WIRE <br />>w I I I I <br />GARAGE <br />I I OPT. CLG. FAN/ <br />GARAGE 0 LIGHT PRE -WIRE <br />I I <br />I I l/ I <br />- GFI ENTRY <br />r--------------------------------, BEDROOM 3 BEDROOM 2 <br />3., <br />I <br />IRRIGATION GFI I I -------- <br />@44"A.F.F. IF t-------- I <br />I I <br />_ I I <br />I I <br />••-----------------------------� •• L------------------------------------� <br />COACH LIGHTS ELECTRICAL PLAN -A <br />OR PREWIRE AS <br />PER SPECS SCALE: Y4"=1'-0" <br />M \ <br />!V <br />N � <br />N <br />n = <br />d <br />7 W <br />0 <br />N <br />+-� <br />LA_ c I� a <br />.N <br />4C O •.. <br />N N O (C <br />m <br />' <br />da-y� <br />E <br />a s c <br />d W � 4 <br />vN CL <br />c E <br />o <br />d <br />Q <br />M <br />O <br />N <br />0 <br />To the est of the Engineer's knowledge, information and bellaf, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residenfial 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal, <br />91 <br />G <br />to <br />N <br />4 <br />M �V U. <br />pC� LL <br />a <br />JIJLLL <br />Z <br />'a a <br />W <br />g�_ 0 <br />°' <br />LLW <br />=Z <br />m <br />NIdk <br />N o <br />c° <br />W <br />z o <br />v— <br />0 <br />� <br />11J <br />U <br />� <br />Owe <br />N <br />c N <br />tLi <br />�- <br />U <br />I <br />w J <br />s � <br />tV lit <br />1,4 <br />eo <br />a <br />M <br />5 <br />" E <br />t� <br />a� <br />p <br />90 <br />WO <br />1— ry <br />AO° <br />� <br />U o <br />Op <br />Z¢� <br />CIS o <br />CD <br />z <br /><g <br />WJ <br />m� <br />O a <br />m j <br />�o <br />aw <br />8< <br />�o <br />WLLI <br />m� <br />�3 <br />5 <br />°§ <br />0 <br />20 <br />= <br />7 Ln <br />_l <br />m <br />co <br />:3N <br />C <br />� <br />N <br />m <br />N <br />O <br />L.n <br />LIo <br />Q <br />o N <br />r <br />N cV <br />r <br />E <br />c t <br />(D <br />Z <br />` <br />Z <br />m <br />E M <br />i <br />v a: <br />c <br />-a <br />0 � <br />¢ IS <br />JOB <br />NO : <br />23-00515 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3 <br />