Laserfiche WebLink
ac <br />a <br />a <br />r0r <br />r0 <br />P�l <br />0 <br />�., I <br />J <br />�,� 1J� <br />KITCHEN <br />O. BATH <br />0 <br />00 <br />KITCHEN <br />BATHROOM 2 <br />INTERIOR DETAILS <br />SCALE: 1/4" = V-0" <br />1'-4"X1'-4" "L„ <br />SHAPE CMU <br />COLUMN <br />fn <br />v� <br />N <br />4 <br />0 <br />Cl) <br />(V <br />60 <br />NOTE: THIS DIAGRAM DEPICTS TYPICAL INSTALLATION <br />VARIES, 2" LESS THAN GUIDELINES TO BE FOLLOWED U.N.O. ON PLANS 42" H UPPER <br />CABINETS BELOW CABINETS-� <br />� { 36"H UPPER <br />CA I CABINETS <br />MIRROR -�. <br />SHWR. SHWR, DOUBLE 30" H UPPER <br />CURTAIN HEAD RODS 16" FOR LINEN CABINETS-� <br />VARIES ROD 12" FOR PANTRY <br />Z OVERHANGS THAT <br />g SINGLE EXCEED 12" MAY <br />24" TOWEL BAR <br />TOWEL BAR IN n ROD REQUIRE A SUPPORT <br />ru ON WALL ABOVE TUB OR SHWR. <br />TOILET TOWEL BAR a BRACKET 36" H BASE <br />O ON BATHROOM WALL 0 FINISHED CABINETS- <br />SHWR. COUNTER TOP 30" H BASE <br />CABINIET `o VALVES® _ $ CABINETS00 <br />MEDIC - <br />TOILET t4 SOAP 'P r, U.`ia <br />PAPER iO DISH °P 1 � <br />r HOLDER 9 L to LO 0 <br />Z�3 ZZZZQ o v t4 ap FRAMING <br />in is 1/2" GYP iv .vv <br />' rNi `' iv TUB r BOARD - <br />BATHROOMS, SHOWERS AND TUBS <br />CLOSETS/LAUNDRY SHELVING <br />V ISLAND COUNTER CABINET BLOCKING <br />BLOCKING AND MOUNTING DETAILS <br />SCALE: 1/4" = 1'-0" <br />ME <br />NZA <br />TYP. @ 2 <br />STORY. SEE <br />JJ/S6 @ <br />STEMWALL <br />0 <br />CO <br />1'-4"X1'-4" "L" J <br />SHAPE CMU <br />COLUMN <br />13'-0" <br />12'-0" <br />1'-4" <br />1 V-8" <br />T-9" 8'-3" <br />LPAD <br />HB O <br />35-SH <br />■ - - - - - - - - <br />I <br />- - - - - - - - - - - - - - <br />II <br />■ <br />I I <br />I <br />LANAI <br />I <br />;NOOK <br />I <br />8'-0" <br />FLAT CLG. AFF <br />I 8'-8" FLAT CLGA-- <br />TILE o <br />12,-4„ <br />- *- <br />I i <br />�� <br />I <br />■ <br />! I II <br />I <br />■ <br />� <br />II I, I f <br />- <br />� <br />I I <br />I <br />■ <br />■ <br />-I 1 I N ! <br />r 1 <br />- <br />1 W <br />1 LIJ <br />F0_ I o <br />0 <br />N i <br />F <br />O <br />1 z <br />FAMILY - <br />--- - <br />■ <br />8'-8" FLAT CLG. j <br />1I o <br />" ( <br />■ <br />-- <br />CARPET <br />JI ..I.. <br />I <br />-- <br />-� �a 2�2„ <br />_ - <br />- <br />- <br />I I <br />- I I <br />- <br />ITCH8 <br />8'-8" FLAT CLG. I'I 2468 <br />- <br />TILE '-0 N <br />fV <br />_ <br />(n <br />FLOOR G.T. <br />rn <br />--------------- <br />--- <br />F- <br />_ _ _ _ <br />-REF ~ <br />- - - - - - <br />- <br />16 <br />, <br />15 <br />5' 741" <br />14 <br />13 <br />DINING <br />(3) 2x4 #2 SPF <br />12 <br />STUDS w/ (3) 16d <br />■ <br />8'-8" FLAT CLG. NAILS @ BASE <br />11 <br />CARPET <br />S3 <br />- <br />is n.p <br />10 <br />42" H 1/2 WALL <br />T-3" 4'-2 " 9 <br />OR RAILING PER <br />SPECS <br />FLOOR G.T. <br />8 <br />-------- <br />------ <br />- - --- <br />7 <br />■ <br />(3) 2x4 #2 SPF <br />6 <br />■ <br />STUDS w/ (3) 16d <br />=t <br />NAILS @ BASEN <br />p <br />-_ <br />O <br />- <br />co O <br />u" <br />- <br />a 1 2 3 5 <br />- <br />- � <br />4068 ARCH _ <br />� PWDR <br />GG <br />, <br />#w// <br />8'-8" FLAT CLG. /cod <br />S3 W. <br />I <br />STUDS HTT16 <br />- - _1 TILE -rL _ <br />■ <br />AT BASE <br />- <br />I <br />TP <br />c <br />o0 <br />FOYER <br />PE <br />�' <br />LAU N <br />Q <br />la <br />8'-8" FLAT CLG <br />( 0 ) - <br />I 8'-8" FLAT CLG. D <br />I <br />- <br />TILE <br />C�61✓ <br />- <br />S4 TILE <br />r3 <br />SW <br />-- <br />W.H. <br />N <br />1T-10" <br />- EDGE OF SLAB 2" BUILDER TO <br />- <br />BEYOND WALL <br />(i) PROVIDE APPLIANCE <br />PROTECTION WHEN <br />I 0 <br />8 <br />NOTE: FINISHED WALLS <br />REQUIRED PER <br />FBC <br />TO BE FLUSH. FIELD <br />- <br />VERIFY. G_T. <br />8'-8" CLG. A.F.F. <br />-- ---- <br />- ----------- <br />I <br />V-0" CLG. A.F.F. <br />ENTRY <br />_ _ <br />54 x 24L <br />54 <br />8'-0" FLAT CLG. AF <br />--_� <br />ATTIC ,' I <br />1 <br />oQ <br />n <br />Vw------ <br />..• <br />GARAGE `A �----J <br />¢ <br />) <br />U <br />8'-0" CLG. A.F.F. <br />H <br />OP <br />F W <br />04 TYP. @ SINGLE <br />> W <br />V-4" 4'4" <br />STORY <br />rA <br />(SEE AA/S3 FOR <br />STEM OPT_ S3 <br />- - - - - -) <br />- <br />I I <br />I <br />I <br />I <br />I <br />I <br />I <br />K <br />I <br />I <br />I <br />I <br />I <br />TYP @ S4 <br />I <br />I o <br />------------------------------- <br />GARAGE <br />I <br />I <br />16070 OVERHEAD DOOR <br />16-0" <br />19'4° <br />25-0" <br />EXTERIOR WALL <br />W/ 2x4 WALL <br />PAD OUT <br />HANSON BOX @ <br />36" A.F.F. <br />DRYER VTE <br />�-- PLUMBING LINE <br />TO SECOND <br />FLOOR <br />�--WIRE SHELF @ <br />+54" A.F.F. <br />0r Cr <br />r- W <br />LU z o <br />2Om <br />HUH <br />J <br />B <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H 1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) -1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2950 <br />H7 <br />(2) -1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />HS <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2950 <br />(2) - 2X4 #2 SYP W/ 1/2" <br />Follow Q/S4. See Plan for <br />RAG <br />FLITCH PLATE <br />Bearing Wall Call Out When <br />Straps are Required <br />" VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE "C" <br />�A <br />+29.7 / -32.2 <br />© <br />+29.7 / -39.7 <br />© <br />+28.3 / -30.8 <br />D , <br />+28.3 / -37.0 <br />0E <br />+26.6 / -29.1 <br />+26.6 / -33.5 <br />SEE SN SHEET O SEE SN SHEET <br />� 40 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />1 +29.7 / -39.7 <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20X26 <br />18JX25J <br />S.H. <br />13 <br />20 X 38 J <br />181 X 37 Jq <br />S.H. <br />14 <br />20 X 501 <br />18 J X 50 <br />S.H. <br />15 <br />20X63 <br />18JX62J <br />S.H. <br />16 <br />20X72 <br />182X71� <br />S.H. <br />1 H2 <br />27 1/4 X 26 <br />26 X 25 1 <br />S.H. <br />1H3 <br />27 1/4 X 38 J <br />26 x 37 1 <br />S.H. <br />1 H4 <br />271 X 501 <br />26 x 50 <br />S.H. <br />1 H5 <br />27 1 X 63 <br />26 X 62 1/2 <br />S.H. <br />1 H6 <br />271 X 72 <br />26 X 71 1/2 <br />S.H. <br />22 <br />37 J X 26 <br />36 } X 25 1/2 <br />S.H. <br />23 <br />37 J X 38 J <br />36 J X 37 3/4 <br />S.H. <br />24 <br />37 J X 50 1 <br />36 3 X 50 <br />S.H. <br />25 <br />37 J X 63 <br />36 J X 62 1/2 <br />S.H. <br />26 <br />37 J X 72 <br />36 1 X 71 1/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 X 25 J <br />S.H. <br />33 <br />54 X 38 J <br />52 X 37 J <br />S.H. <br />34 <br />54 X 501 <br />521 X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 1 X 62 2 <br />S.H. <br />36 <br />54 X 72 <br />52 J X 712' <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply With Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic , crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />MASONRY HGT. @ 8'-8" A.F.F. <br />MASONRY HGT. @ V-0" A.F.F. <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO <br />UPLIFT CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />FIRST FLOOR LIVING AREA 952 S.F. <br />SECOND FLOOR LIVING AREA 1121 S.F. <br />TOTAL LIVING AREA 2073 S.F. <br />GARAGE 396 S.F. <br />LANAI 104 S.F. <br />ENTRY 32 S.F. <br />TOTAL SQ. FT. 2605 S.F. <br />INSULATION REQ. <br />EXT CONC WALL <br />R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 <br />R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 <br />R-19 KRAFT FACED <br />CONDITIONED CEILING <br />R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION <br />R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />FIRST FLOOR PLAN -B <br />SCALE: Y4"=1'-0" <br />On <br />C" <br />o <br />in <br />CD =o <br />W <br />N <br />ca a � <br />C W C� <br />Q <br />X <br />N <br />m <br />I.L <br />N G IZ <br />M O <br />Q � N <br />3 °= a>• x <br />E <br />3L to <br />3 <br />a u m <br />E400 <br />m .� <br />,n a a <br />c E <br />� o <br />K <br />�✓ r' Ste` <br />��' <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions <br />of the drawing pages bearing <br />Engineer's signature and seal. <br />EWA <br />I- <br />A <br />C <br />IA <br />�Iwo <br />NL,20�� <br />yN� LL <br />C .J <br />L LL <br />�1f <br />V <br />_ <br />C <br />LL LL ow <br />�0 rn a Y <br />W`I13grc <br />0 <br />°. m <br />W <br />IL Z <br />I <br />J <br />N & z° d r <br />Z <br />N OL 0 <br />W <br />❑ o <br />Z N th <br />z <br />z <br />J - <br />vo <br />Z Cl) <br />4-J <br />f0 <br />(/7 <br />w 5e <br />jr <br />.0 <br />o <br />�• <br />0 <br />w <br />N <br />W <br />m <br />=Q <br />c . S <br />Q Ln <br />O <br />�rj <br />oa <br />u�l <br />2 <br />LL E <br />F <br />oLL <br />g <br />Q <br />0 <br />E V <br />wz <br />Zw <br />na <br />o <br />EQ <br />Zo <br />CD <br />C/) � <br />Z <br />¢ <br />Y <br />° A <br />O� <br />ZC <br />m N <br />=o <br />cw <br />z <br />W <br />8 <br />$ $ <br />-a <br />i <br />�w <br />O <br />a4 <br />a� <br />d' <br />z1�4 <br />0U ^i <br />0 Ci <br />= <br />>M <br />O <br />M <br />Co <br />co,-� <br />N <br />o <br />N <br />J <br />CL <br />(� m <br />CN <br />o <br />_ <br />O <br />L <br />lie <br />C0 <br />co CN <br />m <br />N <br />CD <br />Ln <br />o <br />z <br />E <br />E M <br />rt <br />a <br />o <br />U <br />�? <br />¢ p <br />� <br />30B <br />NO: <br />23-00512 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />1.� <br />