My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6314 Back Forty Loop
Zephyrhills
>
Building Department
>
Building Plans
>
6314 Back Forty Loop
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 2:02:16 AM
Creation date
2/27/2025 11:20:56 AM
Metadata
Fields
Template:
Building Plans
Street #
6314
Location
Back Forty Loop
Contractor
Lennar Homes
Building Plans - Permit #
5931
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br />I <br />I <br />— — — — — — — — — — — — — — — —� <br />CROSS BRACING DETAIL (TYP.) 1 <br />SCALE: N.T.S. <br />TRUSS NOTES: <br />CONY. FRAMED RIDGE <br />1. WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TP1-2014 MAY BE NAILED <br />(TRUSS PLATE INSTITUTE) NOTE THAT THE COMBINED WIND AREA IS GREATER w/ MIN. (4) 12d WHEN <br />BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE IT LANDS NEXT TO <br />INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST PRE-ENG. TRUSS <br />COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES <br />OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD <br />SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & <br />SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION <br />OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED <br />ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER <br />A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. <br />2. ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS <br />LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTER ALL LATERAL BRACING <br />SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'-0" <br />O.C. MAXIMUM. <br />3. ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED w/ (3) 12d <br />4. ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS <br />NAILS AT EACH TRUSS INTERSECTION. CB---- <br />DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT <br />ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. pg <br />5. PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS <br />DEPTH EXCEEDS STANDARD HEEL HEIGHT SEE TYP TRUSS BLOCKING DETAILS <br />TYP. HAND FRAMING ABOVE TRUSS <br />2X4 STUDS & PLATES AT 2'-0" O.C. <br />EACH DIRECTION TYP. U.N.O. <br />2x8 BLOCKING NAILED @ <br />- EACH SIDE w/ (3) 12d NAILS <br />WHEN REQUIRED w/ (2) <br />SIMPSON HTS20 w/ (24) 10d x <br />1 1/2" NAILS EACH <br />TB <br />PRE-ENG. TRUSS <br />2X4 DIAGONAL AT 8'-0" O.C. 2X4 BLOCKING <br />BETWEEN EA. TRUSS CONT. ROOF SHEATHING AT TRUSS TOP — <br />MAX & EACH END ALTERNATE A CHORD AT ALL HAND FRAMED AREAS TYP. <br />DIRECTION TYP. —� <br />------/— WOOD TRUSS —j <br />A <br />TYP. WOOD TRUSS BLOCKING DETAIL <br />SCALE: N.T.S. <br />PORCH SLAB SEE <br />FOUNDATION PLAN <br />4" <br />1' A" <br />EXTEND <br />SLAB 1 1/2" <br />(2) #5's CONT. T&B w/ <br />#3 STIRRUPS AT 4'-0" <br />WHEN DEPTH <br />EXCEEDS 30" <br />GRADE <br />= z <br />N — <br />T <br />PORCH SILL 15 <br />SCALE: N.T.S. <br />DIAGONAL - <br />AT 8'-0" <br />MAX <br />TRUSS <br />I V 4 `W --W.. . I. W__ <br />r r L V <br />VERTICAL SCAB 2 x 6 <br />#2 SPF 48" O.C. W/ (4) <br />10d TOP & BOTTOM <br />OR SIMPSON H2.5A w/ <br />(10) 8d NAILS <br />COLLAR TIE <br />EVERY 3rd <br />RAFTER <br />2X4 SPF 2 (2) #7X 3-1/2" <br />WOOD SCREW EACH <br />TRUSS OR SIMPSON <br />H2.5A w/ (10) 8d NAILS <br />AT 48" O.C. <br />BEVEL CUTS <br />(OPTIONAL) <br />• 2x8 #2 SPF RIDGE BEAM <br />2x6 RAFTERS FOR SPANS 4FT TO 8FT <br />2X4 RAFTERS FOR SPANS LESS THAN <br />4FT @ 2'-0"O.C. MAX. w/ (3) 10d <br />COMMON TOENAILS TO BEAM <br />2X4 CONT. ATCONC. MASONRY <br />T & B CHORD STEEL OR WOOD <br />BEARING SUPPORT <br />A -A ALTERNATE BLOCKING <br />DETAIL @ INTERIOR BEARING <br />PROVIDE BLOCKING AT ALL TRUSS BEARING <br />SUPPORT WHERE TRUSS DEPTH EXCEEDS <br />STANDARD HEEL HEIGHT <br />SEE FLOOR PLAN <br />FOR BRG. OR <br />NON-BRG. WALL <br />4111 <br />PORCH SLAB SEE <br />FOUNDATION PLAN <br />SEE PLAN FOR <br />REQ'D STAIR INFO. <br />IF CONCRETE STAIRS <br />FORMED & POURED <br />W/ (1) #5 EACH STEP <br />2" <br />n. <br />w <br />z� • <br />d N <br />w <br />U z <br />um <br />(2) #5's CONT. T&B w —' <br />4 <br />W/ #3 STIRRUPS AT N z <br />4'-0" WHEN DEPTH <br />EXCEEDS 30" LOWER OR <br />Sk GARAGE SLAB <br />V-4" SEE PLAN <br />LARGE STEP DOWN 17 <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />3 <br />WOOD POST. SEE FLR <br />PLAN FOR SIZE & BASE <br />CONNECTION SEE <br />—� PLAN <br />EXTEND <br />SLAB 1 1/2" <br />(2) #5's CONT. T&B w/ <br />- - -. 11 <br />4_ ., #3 STIRRUPS AT 4'-0" <br />PORCH SLAB SEE WHEN DEPTH <br />7 <br />FOUNDATION PLAN EXCEEDS 30" <br />N z <br />1'4' <br />ENTRY PORCH SILL r14 <br />SCALE: N.T.S. <br />WOOD OR MASONRY ABOVE <br />MASONRY PIER SEE FLOOR PLAN <br />FOR COLUMN INFO WOOD OR MASONRY <br />INTEGRATE MASONRY ABOVE MASONRY <br />KNEEWALL INTO CMU BASE OR PIER SEE FLOOR <br />MAIN HOUSE PER ELEVATION IF PLAN FOR COLUMN <br />REQUIRED INFO <br />MASONRY KNEE WALL MAX 3 <br />COURSES w/ TOP K.O. COURSE CMU BASE W/ (1) #5 <br />W/ (1) #5 CONT. FILLED CELL VERTICAL EACH <br />REQ'D @ MID SPAN MAX 6'-8" CORNER FILLED <br />MAX 3 SOLID. SEE ELEV. <br />11FCOURSE FOR BASE SIZE <br />rr (3) #5's EA. WAY - <br />SEE ROOF <br />PLAN SHEATHING <br />2X4 BLOCKING <br />BETWEEN TRUSSES <br />SECT. A -A <br />PROVIDE 2X4 MIN. BLOCKING AT <br />OF HIP/RIDGE, TYP.BETWEEN <br />TRUSSES W/ (2) 12D NAILS EACH <br />END TO TRUSS TOP CHORD <br />TYP. <br />�A TRUSS <br />G.T. <br />ADD 2X4 ALONGSIDE <br />TOP CHORD WHEN REQ'D <br />TO PREVENT PLYWOOD <br />SPAN FROM EXCEEDING <br />MAX 24" SPAN (EITHER AUSSES HIP <br />SIDE OR BOTH IF REQ'D) G.T <br />(2) 12D NAILS AT 12" O.C. MAX <br />HIP/RIDGE BLOCKING DETAIL <br />SCALE: N.T.S. <br />z <br />O <br />Q <br />w <br />J <br />w <br />w <br />w- <br />cn _ <br />�r 811 <br />FA Ak PORCH SLAB SEE J. <br />SLAB <br />FOUNDATION PL N <br />A <br />LEVEL <br />TOP COURSE TO <br />BE CHAIR BLOCKS. <br />ENTIRE BASE TO <br />BE FILLED SOLID <br />—SEE ELEV. FOR <br />BLK HGT. <br />—#5 REBAR CONT <br />@ SLAB LEVEL <br />—EXTEND SLAB <br />1 1/2" BEYOND <br />BLOCKFACE <br />EXTEND <br />SLAB 1 1/2" <br />SEE CUT (2) #5's CONT. T&B w/ cv z <br />CONTRACTOR TO INSTALL #3 STIRRUPS AT 4'-0" <br />MIN 3" x 3" WEEP HOLE SECTION FOR WHEN DEPTH <br />ALONG w/ PITCHING SLAB MORE INFO EXCEEDS 30" <br />1'-4" <br />TO DRAIN WATER <br />KNEEWALL OPT. (ELEV TO INDICATES MASONRY COLUMN <br />ENTRY PORCH SILL �16 <br />SCALE: N.T.S.77 <br />SIMPSON LSTA18 <br />w/ (12) 1Od NAILS <br />CENTERED AT <br />SPLIT TO TIE <br />BEAMS TOGETHER <br />SEE FLOOR PLAN <br />FOR COLUMN SIZE <br />& ADDITIONAL INFI <br />EXTERIOR SHEATHING <br />ATTACHED PER SEE ROOF PLAN <br />2x4 STUDS w/ SIMPSON NAILING SCHEDULE FOR BEAM SIZE & <br />SP1 w/ (10) 10d NAILS CONNECTION INFO. <br />AT BASE SEE J/S6 FOR <br />MORE INFO. <br />>IMPSON HUC410 w/ (14) <br />6d INTO HEADER & (6) <br />Od INTO BEAM - SEE <br />1OOF PLAN FOR MORE <br />VFO <br />SEE PLAN <br />FOR CANT. <br />SEE FLOOR PLAN FOR <br />COLUMN SIZE & BASE 7/16" OSB FLITCH PLATE <br />CONNECTION INFO — REQ'D ONLY WHEN <br />INDICATED ON BM. <br />7/16" OSB FLITCH PLATE SEE FLOOR PLAN FOR SCHEDULE/PLAN <br />REQ'D ONLY WHEN COLUMN SIZE & BASE <br />INDICATED ON BM. CONNECTION INFO ^r1—r1^K 1 f% <br />OPTION A SCHEDULE/PLAN OPTION B <br />COMMON BM TO POST ATTACHMENT <br />" 2x4 BASE PLATE W/ <br />SIMPSON LSTA30 w/ <br />(22) 10d NAILS OR <br />- - SIMPSON MTS12 w/ <br />- (14) 10d x 1 1/2" NAILS <br />TO FLOOR GIRDER <br />BELOW @ 16" O.C. <br />><: <br />16" FLOOR SYSTEM FLOOR GIRDER <br />SEE PLAN FOR SEE PLAN FOR <br />DIRECTION CONNECTION <br />SECTION @ FLOOR <br />CONNECTION r22"� <br />SCALE: N.T.S. <br />SIMPSON (2) HTS20 w/ (14) <br />10d NAILS TYP. U.N.O. <br />SEE FLOOR PLAN FOR — <br />COLUMN SIZE & <br />ADDITIONAL INFO. <br />(WOOD COLUMN SHOWN) <br />A F_� A <br />SEE PLAN FOR <br />P OF TAM <br />SEE PLAN FOR <br />CANT. IF <br />INDICATED <br />CORNER �,—SEE FOUNDATION <br />PLAN FOR MORE INFO <br />5" <br />�X <br />COMMON BM. ATTACHMENT <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />1 <br />SIMPSON (2) <br />HTS20 w/ (14) <br />10d NAILS <br />TYP. U. N.O. <br />MIDDLE <br />BM. SPLICE OVER <br />CENTER OF POST <br />WOOD WALL <br />OR TRUSS. <br />SEE PLAN <br />STRUCTURAL SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />VARIES W/ <br />ROOF SLOPE <br />2X4 CONT. W/ (2) <br />16d COMMONS <br />NAILS EACH <br />STUD TYP. T&B <br />—TRUSS OR <br />ROOF SYSTEM <br />SHEAR TRANSFER <br />EXTERIOR. WALL �7 <br />SCALE: N.T.S. <br />2x4 #2 SYP NAILER. NA <br />TO STUDS w/ (3) 16d @ <br />EACH STUD - TOENAIL <br />EACH TRUSS TO <br />NAILER w/ (3) 10d <br />IF 2x DOUBLE LEDGER, <br />ATTACH FIRST PLY <br />w/ (4) 16d NAILS TO EA. <br />END OF TRUSS THEN <br />ATTACH SECOND PLY w/ <br />(3) ROWS OF 16d NAILS <br />AT 24" O.C. <br />ROOF AND EXTERIOR SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />SEE 2ND FLOOR WALL SECTION <br />FOR ADDITIONAL INFORMATION <br />VERIFY FLOOR JOIST W/ RIM <br />BOARD OR FLOOR GABLE W/ <br />FRAMING PLAN <br />SIMPSON LUS26 w/ (8) 10d • <br />NAILS OR IF 2 PLY TRUSS SEE FLOOR FRAMING PLAN <br />SIMPSON LUS26-2 w/ (8) 16d AND J/S6 FOR MORE INFO. <br />NAILS TO LEDGER VERIFY WITH PLAN FOR <br />2X8 #2 SYP CONT. LEDGER W/ LOCATION AND DIRECTION <br />(4) 16d NAILS ATTACH NAILS (IF PARALLE SEE 2/D2 FOR <br />INTO END OF EACH FLOOR BLOCKING INFO) <br />TRUSS, 24" O.C. MAX. (AT EACH <br />SIDE OF G.T. INSTALL (4) NAILS MASONRY WALL <br />EACH SIDE) (TYPICAL) <br />SECTION AT LOW ROOF 9 <br />SCALE: 1/2" = 1'-0" <br />Y2' CDX PLYWOOD OR Y16" O.S.B. <br />SHEATHING REQ'D FROM BOTTOM <br />OF WALL TO ROOF SHEATHING <br />ABOVE W/ 8d NAILS @ 4" O.C. IN <br />FIELD, EDGES & BOUNDARIES <br />COMMON TRUSS <br />W/ INTERIOR BRG. <br />SEE PLAN FOR <br />CONNECTIONS <br />INFO. <br />RUSS/ <br />OP WAL <br />SEE PLAN <br />MIN. (2) 2x8 #2 SYP <br />HEADER. SEE Q/S4 FOR <br />REQ'D CONNECTIONS <br />2x4 #2 SPF STUDS @ <br />12" O.C. W/ USP SPT22 <br />@ BASE & SPT24 @ <br />TOP <br />2X4 #2 SYP P.T. PLATE W/ <br />EPDXY ANCHOR OR <br />J-BOLT OR Y2' TITEN HD <br />2, <br />ANCHOR @ 24" O.C. W/ <br />SEE PLAN MAX. <br />MIN. 6" EMBEDMENT <br />24" STEPS <br />-'—T- <br />x A°-_ X a-_° a <br />SEE PLAN FOR OPT. <br />. . . <br />STAIR INFO. IF <br />'< <br />CONCRETE STAIRS <br />dMAIN HOUSE <br />FORMED &POURED?' <br />SLAB <br />'W/ <br />(1) #5 EACH STEP <br />FA <br />d4'(2) #5's CONT. T&B <br />w/ #3 STIRRUPS AT <br />WHEN DEPTH <br />d4'-0" <br />EXCEEDS 30" <br />d' a ° <br />b ° <br />"' Z <br />GARAGE OR <br />LOWER SLAB <br />SEE PLAN <br />V-4" _ <br />SECTION GARAGE MONO 21 <br />SCALE: N.T.S. <br />e•� <br />N <br />O <br />N <br />U G <br />CM �- <br />d9 <br />DC a w <br />Q o«Q <br />� ati u <br />v7 A Cz `►. <br />N <br />d- <br />'d N 7G <br />d <br />Nam. <br />aW <br />4Od�d <br />a <br />c E <br />o <br />a <br />0 <br />... <br />Q �� �(612 <br />tx � <br />U �Ao (, <br />W t <br />'r •..... ••' <br />\ <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and <br />seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />'I <br />a a A8 <br />0C.00 <br />0 ENO <br />0 <br />iY W <br />U. t+- <br />a <br />Z c1. <br />�po�_ <br />a <br />W '51 <br />4` °' <br />0 <br />Nza� <br />LL=Go <br />N <br />Z O U <br />W <br />❑❑ <br />C 00 <br />Z <br />a <br />OLL' S <br />ll <br />W <br />§ i <br />L- <br />0! <br />o <br />J <br />0 <br />w <br />2 <br />__j <br />W_ <br />o <br />� z <br />k <br />2 <br />E <br />m C1 <br />9 <br />4= <br />s. <br />o0 <br />Qa <br />Z <br />E <br />g ro <br />�q° <br />n.00 <br />aZ <br />W <br />ra <br />S <br />4 ❑ <br />%N <br />O <br />33 <br />C113 <br />d, <br />W <br />a:a <br />IJ�� <br />M <br />d <br />w q~q <br />YIQ <br />o�o F <br />J; <br />°O <br />In <br />= <br />. <br />CC <br />O <br />6 <br />Co Lr) <br />M <br />^ <br />NN0 <br />Cr 0 <br />LC) <br />4.1 o <br />^ m O <br />N <br />E <br />M <br />z <br />m <br />C <br />� `. <br />E (� Iu <br />c <br />Q.0 <br />E :3 <br />_j Q <br />JOB <br />NO: 23-00512 <br />SCALE: AS NOTED <br />SHEET NO. <br />D1 <br />(MONO) <br />
The URL can be used to link to this page
Your browser does not support the video tag.