ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017). by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance With FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />WEATHERPROOF DUPLEX OUTLET <br />W.P. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />G.F.I. <br />HALF -SWITCHED DUPLEX OUTLET <br />I� SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 THREE-WAY SWITCH <br />$4 FOUR-WAY SWITCH <br />$R RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />I--O WALL MOUNTED LIGHT FIXTURE <br />ORECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />P.C. <br />+� TRACK LIGHT <br />- FLUORESCENT LIGHT FIXTURE <br />- EXHAUST FAN <br />Q <br />Q' EXHAUST FAN/LIGHT COMBINATION <br />®D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />PUSH BUTTON SWITCH (OPTIONAL) <br />I{D PUSH BUTTON SWITCH - DOOR BELL <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB TELEPHONE/USB (OPTIONAL) <br />© TELEVISION (OPTIONAL) <br />a 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />L J <br />A 11 <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G T J OPT. CEILING FAN <br />Gi� (1) PHONE LINE, (1) DATA PORT <br />150AI200A INDOOR <br />PANELCENTER <br />NEMA 1 <br />. AMP/ <br />2o0 AMP <br />METER <br />7 <br />200 amp <br />150 amp <br />14 copper to lights & outlets <br />12 copper to 20 amp ckts <br />10-2 copper to W H <br />103 copper to Dryer <br />or 4/0 SER Alu <br />UNDERGROUND DisconneL#4GROUNDING <br />POWER CO. FEED <br />INTERSYSTEM Bare Cu Ground <br />BONDING O WIRE <br />TERMINATION PER WITH CODE APPROVI <br />NEC 17, 250.94 CLAMP PER 250.50 AND <br />250.52 OF NEC 17. <br />Typical 150-200 Amp Electrical Riser Diagram REV.04.06.21 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER CO. <br />U.C. OUTLET <br />SWITCH FOR <br />DISPOSAL <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS <br />SPEC 3 & 4 KITCHEN <br />•--LANA]-- • <br />/�> I <br />I � I <br />AC PAD I I <br />DISC. WP <br />GFI I WP <br />GFFI <br />�Q I <br />141 <br />II ALT ll <br />I <br />l AC PAD <br />0 <br />== =WP DINING BRKF-ST.� - -- <br />■� <br />LIGHT AS PER <br />OPT. D 5'-0" / SPECS <br />— -- <br />_ 5 • <br />LIGHT AS PER i <br />■ SPECS PENDANT <br />LIGHT PER GFI 1 <br />SPECS <br />GREAT RM IGFI IGFI <br />12 <br />■ ROUGH -IN U.C. OUTLET ` _ • <br />FOR OPT. I0: <br />FAN/LIGHT 6'I CD <br />SWITCH FOR I FI1 I p <br />,. <br />OPT. CLG. FAN/ DISPOSAL <br />LIGHT PRE -WIRE I <br />IGFI <br />/ \ / o <br />/ \ \ GFI / <br />2'4 <br />C.M \ 3 I `\ <br />- DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS <br />Ily IjIGITc AIS D I I <br />I I I I WI C11 A O E71-1 <br />- <br />I I I I III I I I j I I I I I' t l • <br />FO T'E GFI @44" <br />A.F.F. 1 W.H. w <br />Z <br />- \— I 1 • moo <br />wo -1 <br />-- I F- > -i ao <br />GARAGE -' U <br />DB WP LIGHT AS LL <br />I I GFI \ PER SPECS w W <br />GARAGE/ > W <br />• <br />I I 1 'O= GARAGE <br />I I DOOR <br />I I <br />ENTRY GFI <br />c) <br />0 <br />■ I I IRRIGATION GFI ■ <br />@44"A.F.F. <br />■ I � I • <br />I I <br />I � I <br />- I I <br />I � I <br />I � I <br />•■------------------ - - - - -- <br />•• <br />-COA-CRzFGATS <br />OR PREWIRE AS <br />` PER SPECS <br />F- <br />L--------------------------- <br />I <br />3" <br />RECEPT. FOR <br />ALARM SYSTEM <br />PROVIDE PHONE / CABLE <br />AND OUTLET AT TECH <br />CENTER <br />GFI @ <br />44" A.F.F- <br />,pl 3" VTR 1.5" VTR <br />I III <br />I� <br />I I <br />I I <br />I I <br />I � I <br />� I I <br />\ I III 3" VTR <br />I � I <br />PLUMBING-RISER- <br />SCALE:NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH P_UMBER <br />ELECTRICAL PLAN - ELEV-A <br />r O <br />xi­46 <br />N <br />N <br />'L- X <br />(� a. <br />Lo <br />L L <br />t <br />7 CD <br />C 1, O O <br />-� <br />1,0 <br />_ <br />L <br />> Q <br />CV <br />N <br />0 <br />N <br />N <br />CV <br />N <br />0 <br />To the best of the Engineers knowledge, informal on and belief <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal is only for <br />the structural <br />engineering portions of the drawing pages bearing <br />Engineer's <br />signature and seal. <br />N! <br />Q <br />sp} E r <br />O M 8 N <br />C>C12i <br />` <br />Cf <br />O <br />'j in oo ve Co t` W <br />M <br />Q <br />�r�rZ2 LL W a <br />aj MTV , CL <br />J W (L <br />,w <br />V <br />Z <br />U S <br />_ � o <br />m c O <br />co CZI c_p O <br />UW <br />�pjO' d a <br />o a <br />Z <br />� MZ tYN O <br />N <br />O)6M <br />W <br />W <br />ODD <br />W <br />Z 7v M <br />z <br />W <br />Q v <br />E3 <br />v J <br />z <br />(D <br />M <br />(111M <br />N <br />WLU <br />0 <br />w <br />tU <br />tm <br />r— <br />C:" <br />CAD <br />M <br />u <br />E <br />a� <br />cc �a <br />go <br />Zo <br />E <br />ry <br />NC <br />Y� <br />o� <br />Z <br />a�`�'i <br />8 <br />° <br />W <br />_ <br />$EE <br />igFR <br />�� <br />JQ <br />WIw <br />(n <br />v <br />g a <br />5 <br />- <br />O <br />1) L <br />O_ <br />m <br />V <br />ra <br />�' <br />N <br />V J ? <br />Cfl <br />n <br />CO <br />CO <br />N <br />O <br />CD <br />In <br />T <br />Q <br />N <br />T <br />a <br />N <br />CV <br />N N <br />p <br />Z <br />Z <br />C <br />E N <br />EE <br />M <br />IT <br />U <br />a <br />L C7 <br />JOB NO : <br />22-02368 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3 <br />