My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6324 Ten Acre Ct
Zephyrhills
>
Building Department
>
Building Plans
>
6324 Ten Acre Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 6:58:06 AM
Creation date
2/27/2025 11:21:50 AM
Metadata
Fields
Template:
Building Plans
Street #
6324
Location
Ten Acre Ct
Contractor
Lennar Homes
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150A1200A INDOOR <br />PANEL CENTER <br />N14 to rights & outlets <br />NEMA 1 01 a12 to appliances and GFI <br />150 AMPI <br />200 AMP 10 #10 to WH <br />01 A8 to Range <br />111 N6 to HVAC <br />r <br />50=2/0 <br />200=410 in 2" Conduit <br />200 amp <br />150 amp <br />UNDERGROUND <br />SERVICE BY POWER CO. <br />INTERSYSTEM4 <br />T,*ne <br />Bare Cu Ground <br />BONDING4 <br />GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 17, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />G E N E RAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done In strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired Into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />With R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FfT <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />?4, <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />® <br />EXHAUST FAN <br />;O <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />DB <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />N <br />ELECTRIC METER <br />LL <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />L J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />11 <br />II <br />II <br />II <br />11 <br />1.5" VTR —111 <br />I� <br />I <br />I <br />I <br />1 r. <br />� i I <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />SWITCH FOR D <br />KITCHEN <br />DEDICATED <br />ECEPTACLE <br />AICROWAVE <br />4.NGE HOOD <br />PER SPECS <br />OPTIONAL LIGHTING <br />SCALE: Y4'=1'-0" <br />o % I <br />r-----------i <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ I I <br />'LIGHT PRE -WIRED 7 <br />I I <br />BEDROOM 2 <br />I I I <br />I I <br />I I I <br />I-----------f <br />I I <br />I <br />I <br />I I <br />I <br />I I <br />I I <br />I I <br />I <br />I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />L---------------------------------------i <br />SWITCH FOR <br />DISPOSAL IN <br />CABINET — <br />I ====z I <br />II ALT II <br />I I AC PAD I I <br />It 11 <br />WP <br />GFI4 <br />DISC. <br />li l� <br />w}' <br />�OQ <br />craLU b <br />O m <br />` PER SPECS <br />ELECTRICAL PLANS-B <br />SCALE: Y4'=1'-0" <br />C'T <br />G <br />C W <br />O L � <br />min <br />u to cn <br />.p QO X <br />c�-n <br />N cc O ti <br />N <br />cz <br />d Q 5 Q <br />t3 <br />Y y d 40 <br />i c <br />C <br />to c� <br />a v <br />0 <br />N <br />ti <br />N <br />r_ <br />0 <br />To the best of the Engineer's knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florlda Building Code - <br />Residential 7th Edition. Engineer's signature and seal Is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />a W <br />Q <br />E <br />� 8 o <br />N <br />V <br />0 ? Co <br />tii <br />4 <br />M v <br />Z <br />� Lit t1 LL a <br />0 rn o. <br />to <br />1C2 O <br />W <br />2 <br />�QjO' o <br />LL Z <br />tXO <br />Z Q <br />Z <br />Lnm, <br />N <br />O U <br />W <br />to <br />❑ ❑ <br />z <br />za <br />A <br />LL <br />U <br />w <br />0 <br />�f6 <br />c R <br />"3 <br />wrls <br />04 <br />IIII� <br />w <br />M <br />� <br />o <br />0 <br />�YyD <br />> <br />z <br />Z>� <br />=a <br />a <br />to U <br />o <br />�� <br />o <br />'oag= <br />r <br />CV t <br />(CS <br />�_ <br />Z <br /><Tj <br />uj <br />$ <br />0 <br />Nz <br />W <br />U � <br />�ii <br />E <br />�� <br />0 <br />Mill <br />a <br />12O <br />J <br />>L <br />ai <br />rn <br />L° <br />c7 <br />L <br />Lf7 <br />0 <br />�-� <br />� <br />Cr <br />�.. <br />.2 <br />CV <br />O <br />LO <br />a) <br />N <br />o <br />LO <br />T <br />Q <br />Q <br />T <br />ai <br />M <br />a <br />C`V <br />N t` <br />o <br />Z <br />E <br />a <br />U <br />Q p <br />JOB <br />NO: <br />22-08304 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.