My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6330 Ten Acre Ct
Zephyrhills
>
Building Department
>
Building Plans
>
6330 Ten Acre Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 10:00:55 AM
Creation date
2/27/2025 11:22:03 AM
Metadata
Fields
Template:
Building Plans
Street #
6330
Location
Ten Acre Ct
Contractor
Lennar Homes
Building Plans - Permit #
5541
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
W <br />C) <br />i <br />m <br />N <br />01 <br />_ <br />0 <br />Q <br />0 <br />0 <br />0 <br />00 <br />N I <br />0 <br />-t- <br />o <br />i <br />C <br />iJ <br />a <br />N <br />i <br />0 <br />L1 <br />E <br />0 <br />L <br />0 <br />C <br />C <br />J <br />y <br />r7 <br />U <br />v <br />O <br />U <br />U <br />O <br />i <br />i <br />z <br />N <br />I <br />x <br />0 <br />v <br />J <br />L�. <br />n <br />0 <br />0 <br />0 <br />Q <br />r <br />m <br />nv� <br />I <br />I <br />I <br />I <br />I <br />I <br />-------------� <br />CROSS BRACING DETAIL (TYP.) 1 <br />SCALE: N.T.S. <br />TRUSS NOTES: <br />1. WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TP1-2014 CONY. FRAMED RIDGE <br />YBE NAILED <br />(TRUSS PLATE INSTITUTE) NOTE THAT THE COMBINED WIND AREA IS GREATER w/ MIN. (4) 12d WHEN <br />BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE IT LANDS NEXT TO <br />INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST PRE-ENG. TRUSS <br />COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES <br />OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES, THIS CONSTRUCTION LOAD <br />SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & <br />SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION <br />OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED <br />ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER <br />A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. <br />2. ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS <br />LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTER ALL LATERAL BRACING <br />SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'-0" <br />O.C. MAXIMUM. <br />3. ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED w/ (3) 12d <br />NAILS AT EACH TRUSS INTERSECTION. CB <br />4. ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS <br />DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT <br />ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. Dg <br />5. PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS <br />DEPTH EXCEEDS STANDARD HEEL HEIGHT SEE TYP TRUSS BLOCKING DETAILS <br />TYP. HAND FRAMING ABOVE TRUSS <br />2X4 STUDS & PLATES AT 2'-0" O.C. <br />EACH DIRECTION TYP. U.N.O, <br />2x8 BLOCKING NAILED @ <br />- EACH SIDE w/ (3) 12d NAILS <br />WHEN REQUIRED w/ (2) <br />SIMPSON HTS20 w/ (24) 10d x <br />1 1/2" NAILS EACH <br />TB <br />PRE-ENG. TRUSS <br />2X4 DIAGONAL AT 8'-0" O.C. 2X4 BLOCKING <br />MAX &EACH END ALTERNATE BETWEEN EA. TRUSS CONT. ROOF SHEATHING AT TRUSS TOP - <br />^ CHORD AT ALL HAND FRAMED AREAS TYP. <br />DIRECTION TYP. <br />-----/-- WOOD TRUSS -� <br />A <br />TYP. WOOD TRUSS BLOCKING DETAIL <br />SCALE: N.T.S. <br />PORCH SLAB SEE EXTEND <br />FOUNDATION PLAN SLAB 1 1/2" <br />(2) #5's CONT. T&B w/ <br />411 11 " #3 STIRRUPS AT 4'-0" <br />WHEN DEPTH <br />EXCEEDS 30" <br />GRADE <br />• < -. _ N z_ <br />V-4" <br />PORCH SILL �15 <br />SCALE: N.T.S. <br />DIAGONAL - <br />AT 8'-0" <br />MAX <br />WOOD <br />TRUSS <br />7► T <br />VERTICAL SCAB 2 x 6 <br />#2 SPF 48" O.C. W/ (4) <br />10d TOP & BOTTOM <br />OR SIMPSON H2.5A w/ <br />(10) 8d NAILS <br />COLLAR TIE <br />EVERY 3rd <br />RAFTER <br />2X4 SPF 2 (2) #7X 3-1/2" <br />WOOD SCREW EACH <br />TRUSS OR SIMPSON <br />H2.5A w/ (10) 8d NAILS <br />AT 48" O.C. <br />BEVEL CUTS <br />(OPTIONAL) <br />2x8 #2 SPF RIDGE BEAM <br />* * 2x6 RAFTERS FOR SPANS 4FT TO 8FT <br />2X4 RAFTERS FOR SPANS LESS THAN <br />4FT @ 2'-0"O.C. MAX. w/ (3) 10d <br />COMMON TOENAILS TO BEAM <br />2X4 CONT. AT- / CONC. MASONRY <br />T & B CHORD STEEL OR WOOD <br />BEARING SUPPORT <br />A -A ALTERNATE BLOCKING <br />DETAIL a@ INTERIOR BEARING <br />PROVIDE BLOCKING AT ALL TRUSS BEARING <br />SUPPORT WHERE TRUSS DEPTH EXCEEDS <br />STANDARD HEEL HEIGHT <br />SEE FLOOR PLAN SEE PLAN FOR <br />FOR BRIG. OR REQ'D STAIR INFO. <br />NON-BRG. WALL IF CONCRETE STAIRS <br />FORMED & POURED <br />W/ (1) #5 EACH STEP <br />2.' <br />•, ° <br />0- <br />- 11 <br />n I_ <br />4 -i h< " < z to <br />PORCH SLAB SEE -I a N <br />_ wX <br />FOUNDATION PLAN w Q <br />� 2 Z <br />(2) #5's CONT. T&B <br />- _ <br />.z <br />W/ #3 STIRRUPS AT < <br />CV <br />1 11 < T <br />4- WHEN P - <br />0 HE DEPTH _ <br />EXCEEDS 30" ° ° ° " " LOWER OR <br />GARAGE SLAB <br />1'4" SEE PLAN <br />LARGE STEP DOWN �17 <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />2X4 STUDS w/ SIMPSON <br />SP1 w/ (10) 10d NAILS <br />AT BASE SEE J/S6 FOR <br />MORE INFO. <br />WOOD POST. SEE FLR "{ <br />PLAN FOR SIZE & BASE <br />CONNECTION TFs4 <br />EXTEND <br />SLAB 1 1/2" <br />-- -: `a • ° <br />- _... (2) #5's CONT. T&B w/ <br />_- #3 STIRRUPS AT 4'-0" <br />PORCH SLAB SEE -4' WHEN DEPTH <br />7 <br />- EXCEEDS 30 <br />FOUNDATION PLAN GRADE <br />r - <br />1'-4" <br />ENTRY PORCH SILL rl 4 <br />SCALE: N.T.S. <br />WOOD OR MASONRY ABOVE <br />MASONRY PIER SEE FLOOR PLAN <br />FOR COLUMN INFO WOOD OR MASONRY <br />INTEGRATE MASONRY ABOVE MASONRY <br />KNEEWALL INTO CMU BASE OR PIER SEE FLOOR <br />MAIN HOUSE PER ELEVATION IF PLAN FOR COLUMN <br />REQUIRED INFO <br />MASONRY KNEE WALL MAX 3 <br />COURSES w/ TOP K.O. COURSE CMU BASE W/ (1) #5 <br />W/ (1) #5 CONT. FILLED CELL VERTICAL EACH <br />I L <br />REQ'D @MID SPAN MAX 6'-8" CORNER FILLED <br />MAX 3 SOLID. SEE ELEV. <br />COURSE FOR BASE SIZE <br />(3) #5's EA. WAY- <br />SEE ROOF <br />PLAN SHEATHING <br />2X4 BLOCKING <br />BETWEEN TRUSSES <br />SECT. A -A <br />PROVIDE 2X4 MIN. BLOCKING AT <br />OF HIP/RIDGE, TYP.BETWEEN <br />TRUSSES W/ (2) 12D NAILS EACH <br />END TO TRUSS TOP CHORD <br />TYP. <br />�A TRUSS <br />G.T. <br />ADD 2X4 ALONGSIDE <br />TOP CHORD WHEN REQ'D <br />TO PREVENT PLYWOOD <br />SPAN FROM EXCEEDING <br />MAX 24" SPAN (EITHER AUSSES HIP <br />SIDE OR BOTH IF REQ'D) G.T <br />(2) 12D NAILS AT 12" O.C. MAX <br />HIP/RIDGE BLOCKING DETAIL <br />SCALE: N.T.S. <br />z <br />O <br />Q <br />W <br />J <br />W <br />w <br />Uj <br />a - <br />° <br />° <br />SLAB FOUNDATION PORCH SLAB SEE <br />° " PLAN <br />8 _ LEVEL - --. <br />SEE CUT #3 STIRRUPS AT 4'-0" <br />2 #5 s CONT. T&B w/ - <br />CONTRACTOR TO INSTALL - <br />MIN 3" x 3" WEEP HOLE SECTION FOR WHEN DEPTH - - <br />ALONG w/ PITCHING SLAB MORE INFO EXCEEDS 30" <br />1'-4" <br />TO DRAIN WATER <br />KNEEWALL OPT. (ELEV TO INDICATE) MASONRY COLUMN <br />ENTRY PORCH SILL 16 <br />SCALE: N.T.S. <br />SIMPSON LSTA18 <br />W/ (12) 1Od NAILS <br />CENTERED AT <br />SPLIT TO TI E <br />BEAMS TOGETHEF <br />SEE FLOOR PLAN <br />FOR COLUMN SIZI <br />& ADDITIONAL INFI <br />EXTERIOR SHEATHING <br />ATTACHED PER <br />NAILING SCHEDULE <br />2X4 BASE PLATE W/ <br />SIMPSON LSTA30 w/ <br />(22) 10d NAILS OR <br />SIMPSON MTS12 w/ <br />(14) 10d x 1 1/2" NAILS <br />TO FLOOR GIRDER <br />BELOW @ 16" O.C. <br />--- <br />.._._- L__ <br />16" FLOOR SYSTEM FLOOR GIRDER <br />SEE PLAN FOR SEE PLAN FOR <br />DIRECTION CONNECTION <br />SECTION aC� FLOOR <br />CONNECTION 22 <br />SCALE: N.T.S. <br />>IMPSON HUC410 w/ (14) <br />6d INTO HEADER & (6) <br />Od INTO BEAM - SEE <br />1OOF PLAN FOR MORE <br />VFO <br />TOP COURSE TO <br />BE CHAIR BLOCKS. <br />ENTIRE BASE TO <br />BE FILLED SOLID <br />SEE ELEV. FOR <br />BLK HGT. <br />-#5 REBAR CONT <br />@ SLAB LEVEL <br />-EXTEND SLAB <br />1 1/2" BEYOND <br />BLOCK FACE <br />EXTEND <br />SLAB 1 1/2" <br />L.SEE PLAN L. <br />FOR CANT. <br />SEE FLOOR PLAN FOR <br />COLUMN SIZE & BASE 7/16" OSB FLITCH PLATE <br />CONNECTION INFO REQ'D ONLY WHEN <br />INDICATED ON BM. <br />7/16" OSB FLITCH PLATE SEE FLOOR PLAN FOR SCHEDULE/PLAN <br />REQ'D ONLY WHEN COLUMN SIZE & BASE <br />P IO A INDICATED ON BM. CONNECTION INFO r1nT1r'1A <br />O T N SCHEDULE/PLAN <br />OPTION B <br />COMMON <br />BM. <br />TO <br />POST ATTACHMENT <br />SEE ROOF PLAN <br />FOR BEAM SIZE & <br />CONNECTION INFO. <br />SIMPSON (2) HTS20 w/ (14) <br />10d NAILS TYP. U.N.O. <br />SEE FLOOR PLAN FOR — <br />COLUMN SIZE & <br />ADDITIONAL INFO. <br />(WOOD COLUMN SHOWN) <br />oe <br />o <br />CORNER SEE FOUNDATION <br />PLAN FOR MORE INFO <br />5" <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />SIMPSON (2) <br />HTS20 w/ (14) <br />10d NAILS <br />TYP. U.N.O. <br />MIDDLE <br />BM. SPLICE OVER <br />CENTER OF POST <br />WOOD WALL <br />OR TRUSS. <br />SEE PLAN <br />STRUCTURAL SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />VARIES W/ <br />ROOF SLOPE <br />2X4 CONT. W/ (2) <br />16d COMMONS <br />NAILS EACH <br />STUD TYP. T&B <br />-TRUSS OR <br />ROOF SYSTEM <br />SHEAR TRANSFER <br />EXTERIOR. WALL r7 <br />SCALE: N.T.S. <br />2x4 #2 SYP NAILER. NA <br />TO STUDS w/ (3) 16d @ <br />EACH STUD - TOENAIL <br />EACH TRUSS TO <br />NAILER w/ (3) 10d <br />IF 2x DOUBLE LEDGER, <br />ATTACH FIRST PLY <br />w/ (4) 16d NAILS TO EA. <br />END OF TRUSS THEN <br />ATTACH SECOND PLY w/ <br />(3) ROWS OF 16d NAILS <br />AT 24" O.C. <br />ROOF AND EXTERIOR SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />SEE 2ND FLOOR WALL SECTION <br />FOR ADDITIONAL INFORMATION <br />VERIFY FLOOR JOIST W/ RIM <br />BOARD OR FLOOR GABLE W/ <br />FRAMING PLAN <br />SIMPSON LUS26 w/ (8) 10d • <br />NAILS OR IF 2 PLY TRUSS SEE FLOOR FRAMING PLAN <br />SIMPSON LUS26-2 w/ (8) 16d AND J/S6 FOR MORE INFO. <br />NAILS TO LEDGER VERIFY WITH PLAN FOR <br />2X8 #2 SYP CONT. LEDGER W/ LOCATION AND DIRECTION <br />(4) 16d NAILS ATTACH NAILS (IF PARALLE SEE 2/D2 FOR <br />INTO END OF EACH FLOOR BLOCKING INFO) <br />TRUSS, 24" O.C. MAX. (AT EACH <br />SIDE OF G.T. INSTALL (4) NAILS MASONRY WALL <br />EACH SIDE) (TYPICAL) <br />E:1 <br />SECTION AT LOW ROOF 9 <br />SCALE. 1/2 - 1-101 <br />COMMON TRUSS <br />W/ INTERIOR BRIG. <br />SEE PLAN FOR <br />CONNECTIONS <br />INFO. <br />------------- <br />RUSS/ <br />OP WAI <br />EE PLAN <br />%2' CDX PLYWOOD OR %6" O.S.B. <br />MIN. (2) 2x8 #2 SYP <br />SHEATHING REQ'D FROM BOTTOM <br />HEADER. SEE Q/S4 FOR <br />OF WALL TO ROOF SHEATHING <br />REQ'D CONNECTIONS <br />ABOVE W/ 8d NAILS @ 4" O.C. IN <br />FIELD, EDGES & BOUNDARIES <br />SEE PLAN MAX. <br />24" STEPS <br />SEE PLAN FOR OPT. <br />STAIR INFO. IF <br />CONCRETE STAIRS <br />FORMED & POURED <br />W/ (1) #5 EACH STEP <br />GARAGE OR <br />LOWER SLAB <br />SEE PLAN <br />- 2x4 #2 SPF STUDS @ <br />12" O.C. W/ USP SPT22 <br />@ BASE & SPT24 @ <br />TOP <br />2x4 #2 SYP P.T. PLATE W/ <br />Y8" EPDXY ANCHOR OR <br />J-BOLT OR %2' TITEN HD <br />ANCHOR @ 24" O.C. W/ <br />MIN. 6" EMBEDMENT <br />d e < a <br />e u <br />MAIN HOUSE <br />SLAB <br />(2) #5's CONT. T&B <br />W/ #3 STIRRUPS AT <br />-0" WHEN DEPTH 4' <br />EXCEEDS 30" <br />SECTION GARAGE MONO 21 <br />SCALE: N.T.S. <br />ti <br />y r� <br />.mom <br />- C.'- <br />- <br />;.M iz <br />ts. <br />� v n <br />e <br />0 <br />ttt11?ii�JlP`t��9a <br />11 Wh zx� <br />ec <br />riSE <br />�i <br />•• <br />0 <br />�/Pl1111111 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seat is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />RM ' N <br />IN <br />4 <br />� <br />W <br />0 <br />g o N o <br />5 o m ti <br />o <br />w <br />o � co <br />in r <br />4; <br />N O 1 <br />W M J <br />Q G J W <br />�LL� a- <br />5 <br />0 W <br />Z �o <br />Yr �' <br />o <br />V%��_O N� W <br />.z <br />LL `' <br />a O U U o <br />Z <br />Wks i' W <br />o S <br />z <br />z o <br />N <br />N z �O <br />W <br />Lu <br />— <br />O w o <br />t.N c N <br />�N <br />c6 <br />Lu JF— — E <br />— 8 <br />m�........ <br />I <br />t <br />U 8 <br />Q <br />'o <br />No <br />4c I1 <br />co <br />co <br />w <br />Mza <br />g <br />Q E <br />E o <br />_ o <br />oo <br />w� <br />g <br />>o <br />Z® <br />H <br />O E <br />2� <br />O¢ <br />2Z <br />-o <br />O"" <br />o <br />L <br />�o <br />az <br />�w <br />cn C <br /><o <br />U <br />y <br />mo <br />aLL <br />Z <br />J <br />O <br />�� <br />�Wo <br />Q W <br />�o <br />one <br />Pj <br />00 ` <br />U <br />0 <br />mk <br />o <br />w¢ <br />>° <br />a <br />�- <br />0 <br />� O <br />Lo <br />y <br />� <br />CC <br />O <br />c <br />am <br />m <br />2 <br />ca <br />O <br />T <br />C^T <br />T <br />cYi <br />V / O <br />m <br />LN <br />N <br />O <br />O <br />N <br />O <br />CV <br />Q N <br />l.C) <br />r <br />ai <br />cu <br />z N <br />n <br />o <br />z <br />z <br />EO <br />a <br />0 v <br />a _j Q o <br />a) <br />JOB <br />NO: 22-08305 <br />SCALE: AS NOTED <br />SHEET NO. <br />D 1 <br />(MONO) <br />
The URL can be used to link to this page
Your browser does not support the video tag.