My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6330 Ten Acre Ct
Zephyrhills
>
Building Department
>
Building Plans
>
6330 Ten Acre Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 10:00:55 AM
Creation date
2/27/2025 11:22:03 AM
Metadata
Fields
Template:
Building Plans
Street #
6330
Location
Ten Acre Ct
Contractor
Lennar Homes
Building Plans - Permit #
5541
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44"AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />P4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />�D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PI3 <br />PUSH BUTTON SWITCH (OPTIONAL) <br />DB <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />f a <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />�M <br />ELECTRIC METER <br />_Q <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />C� J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />r J <br />OPT. CEILING FAN <br />w <br />(1) PHONE LINE, (1) DATA PORT <br />150A/200A INDOOR <br />PANEL CENTER ELECTRICAL SPECIFICATION NOTES: <br />10 #14 to lights & outlets ELECTRICAL CONTRACTOR MUST VERIFY <br />NEMA7 0 #12 to appliances and GFI WITH THE SPECIFICATIONS FOR THE TYPE <br />150 AMP/ <br />200AMP #10 to WH <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />#8 to Range SHOWN ARE FOR LOCATION PURPOSES. <br />#6 to HVAC <br />METER <br />Mery WP A/C PAD <br />150=2/0 DISC. <br />200=410 in 2" Conduit GFI <br />0 amp 15} 6 <br />150 amp <br />UNDERGROUND Disconnect <br />SERVICE BY POWER CO. <br />INTERSYSTEM 4 Bare Cu Ground <br />BONDING #4GROUNDING WIRE <br />TERMINATION PER WITH CODE APPROVE <br />NEC 17, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />1.5" VTR <br />ail <br />I` <br />I <br />_III 3" VTR I <br />//jam I I <br /><� I I <br />I" VTp <br />SWITCH <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />�J1I <br />DR <br />7 I <br />iF <br />AL <br />I \ <br />I <br />QFf <br />I <br />/ <br />I J <br />I L <br />F <br />GFII X <br />N <br />DW <br />1 <br />C#FI <br />KITCH)-i1a) <br />w <br />REF <br />— <br />L_ <br />IL---- <br />DEDICATED <br />RECEPTACLE FOR <br />ICROWAVE RANGE <br />HOOD PER SPECS <br />SPEC 3 & 4 KITCHEN <br />SCALE: %4'=V-0" <br />LANAI -- I - <br />*12 � I - NOOK _ <br />' ROUGH -IN FOR <br />'OPT. CLG. FAN/ <br />LIGHT PRE -WIRE / - <br />-- <br />w <br />/ T-4"13 / 4"! <br />I SWITCH FbR FI <br />FI <br />FAMILY DISPOSAL Gi — <br />I - IF <br />I PENDANT I I <br />I ROUGH -IN FOR AS PER I I <br />OPT. CLG. FAN/ SPECS GFI I <br />LIGHT PRE -WIRE M I <br />12 10 ( DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />G I DW _ C3FI HOOD PER SPECS <br />I I_� <br />GFI F <br />/KITCHE <br />IL <br />REFFI <br />J <br />----- CH <br />DINING = <br />' PENDANT AS <br />PER SPECS <br />TO LIGHTS <br />C.M. AND <br />SWITCH <br />- 3 ABOVE <br />FOYER <br />/ <br />I <br />IENTR�� <br />DB &GFI TO I GFI <br />BE ALIGNED — — — — — — — - <br />VERTICALL <br />I <br />l <br />o` <br />0 <br />ll�l�ll <br />lFl•ljl4l:lLljl1l1l;l:r1l-T'IDA <br />qp <br />GFI @ 44" kW GFI @ 44" <br />-- <br />A.F.F. A.F.F. <br />w � <br />w <br />w J <br />° <br />/ ZO Z <br />F-a <br />— <br />m <br />/ <br />UO Q <br />QUIZ- <br />I <br />J U <br />/LL <br />D <br />} F <br />--------r--- GARAGE; ------ <br />wu <br />GARAGE <br />o LIGHT AS <br />PER SPECS <br />o` <br />GARAGE <br />---------------DOOP---------------- <br />I GFI <br />IRRIGATION <br />GFI @ 44" <br />A.F.F. <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />LO <br />T <br />COACH LIGHTS COACH LIGHTS <br />OR PREWIRE AS OR PREWIRE AS <br />PER SPECS / PER SPECS <br />FIRST FLOOR ELECTRICAL PLAN-B <br />� I I <br />I I <br />I I I <br />I I I <br />I I I <br />L — — — — — — — — — - I I <br />1 I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />1 I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />--------------------------------------- <br />SECOND FLOOR ELECTRICAL PLAN-B <br />0 <br />✓� 60t <br />C%4 a . <br />as <br />N O RI <br />y � c <br />c 4-1 <br />aa. -- _3 as <br />1w E <br />Co o <br />ate. <br />N <br />0 <br />N <br />1�— <br />N <br />ti <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within <br />these <br />drawings comply with the 2020 Florida Building Code <br />- <br />Residential 7th Edition. Engineers signature and seal <br />is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />N <br />W E <br />0 <br />a <br />C <br />t? ON O cc r <br />® n 000 m OD m <br />tH ti r ° S <br />+Q C ,_t LL <br />V LL ILL a- <br />Z <br />tsy6 o <br />3 f6 N <br />W <br />' <br />U5 91 m w <br />J <br />Z N Z 2CLL <br />LL <br />Z N OU of < 0 <br />W ❑o <br />z N M <br />O <br />N <br />z o � <br />C <br />N <br />M <br />cn z U_ <br />U 0 <br />� <br />LL <br />Uo <br />Ow <br />V1 c <br />�V) <br />U <br />l— J E <br />all LL, <br />8 <br />E <br />I <br />ID <br />U o <br />Y <br />t16 <br />V N Q <br />44 <br />o <br />cD <br />J <br />W <br />M <br />o <br />z <br />Z <br />U_ <br />F <br />a <br />N V <br />E� <br />o <br />® <br />oa <br />V O <br />I— <br />XU <br />¢ ¢ <br />0U <br />O < <br />Q <br />ZO <br />CV <br />4 Z <br />o <br />ao <br />W Z <br />w <br />i <br />U) <br />U <br />m� <br />o � <br />Z <br />Z <br />0 <br />In <br />'� <br />¢ <br />o� <br />Z 2 <br />Z <br />5Z <br />N <br />a <br />Qo <br />6_ <br />T- <br />o <br />1�_3 <br />< <br />�� <br />;o <br />Cfl <br />a <br />003 <br />V' <br />as <br />O <br />2 <br />>M <br />M r <br />O <br />CrcYi <br />T <br />m <br />LL i <br />N <br />C) <br />N <br />LO <br />tV <br />Q <br />E <br />N <br />o <br />Z <br />E 0 ra <br />m <br />a <br />E <br />v _j Q o <br />c <br />JOB NO: 22-08305 <br />SCALE : AS NOTED <br />SHEET NO. <br />3 <br />