My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6338 Back Forty Loop
Zephyrhills
>
Building Department
>
Building Plans
>
6338 Back Forty Loop
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 1:40:15 PM
Creation date
2/27/2025 11:22:38 AM
Metadata
Fields
Template:
Building Plans
Street #
6338
Location
Back Forty Loop
Contractor
Lennar Homes
Building Plans - Permit #
6031
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150AI200A INDOOR <br />PANEL CENTER <br />10 #14 to lights 8 outlets <br />NEMA 1 #12 to appliances and GFI <br />150 AMPI <br />200 AMP 10 #10 to WH <br />00 #8 to Range <br />11111 #6 to HVAC <br />150=2/0 <br />200=410 in 2" Conduit <br />200 amp <br />150 amp <br />UNDERGROUND <br />Disconnect <br />SERVICE BY POWER CO. <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />04 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 17. 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES . Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. ElectrlcaI outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance With R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />With R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed Within 6' of <br />the outside edge of a sink. This would include the receptacle Installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FEF <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />I_Q <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />j4 <br />FOUR-WAY SWITCH <br />jR <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />0 <br />a2 <br />n_ <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CHIMES (OPTIONAL) <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />TELEPHONE/USB (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />1.5" VTR III 3" VTR <br />I� <br />ICI I <br />I� I <br />I I <br />I ^ I <br />dl3" VTR <br />10 <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />SWITCH FOR <br />DISPOSAL <br />DEDICATED ' <br />RECEPTACLE FOR <br />MICROWAVE RANG <br />HOOD PER SPECS <br />SPEC 3 & 4 KITCHEN <br />SCALE: %4'"=1'-0" <br />A/C PAD <br />DISC. WP <br />GFI <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS <br />FI 4—DB & GFI TO <br />------- BE ALIGNED <br />VERTICALLY <br />I <br />I <br />r] <br />COACH LIGHTS ACOACH LIGHTS <br />OR PREWIRE AS OR PREWIRE AS <br />PER SPECS / PER SPECS <br />W'lYliluultllrlLJ .W t <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />I I I <br />I I I <br />I I I <br />I I I <br />I I I <br />I----------_j <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />L- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — J <br />SECOND FLOOR ELECTRICAL PLAN <br />FIRST FLOOR ELECTRICAL PLAN - ELEV-B <br />ELEV-B <br />C" <br />O o <br />N '— <br />C" w <br />O <br />N 1z p <br />u N Fa <br />Q - o M >< <br />y w o to <br />Q N Y <br />3 w <br />s 3 m <br />ea ty w � <br />%. c t� <br />a}i <br />y 1r • <o }. <br />C M EO <br />d. U <br />n <br />N <br />0 <br />,11t9iti89lL c•� <br />��GO C.G,Pd <br />�•�,. <br />U�.` lid <br />i `,' <br />NO Pf- <br />STA -E <br />filifill'01" <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />/W v �p1-4 <br />O N <br />= ^ r <br />VO4 6� <br />�M0� LL <br />M a a <br />Q ��� a 4 <br />Zc� zoo <br />13 <br />$ o �a� <br />0 <br />i' •f0 N 00 J <br />rR�F� ¢ K z <br />w <br />Z 1.0 Cl)Z N H <br />ILW <br />N U <br />Z O U ❑❑❑ <br />Z <br />W <br />7 N M <br />z � <br />7 <br />a <br />054 <br />N z <br />�4-J_ <br />U <br />0 <br />w s <br />CIAN^I Ly <br />I <br />v ' -91 <br />� <br />N � <br />C) <br />0 <br />C' <br />44 <br />w <br />M <br />M <br />¢ <br />Zx <br />E <br />oa� <br />aE <br />p <br />Y <br />?® <br />oa <br />~ ro <br />O <br />U <br />U <br />7 U <br />�- <br />cc'o <br />F <br />a= <br />g <br />Z <br />ro <br />w <br />C"czro <br />Ca <br />C <br />a <br />�¢ <br />Z <br />Z <br />} <br />m J <br />y U <br />a� <br />F <br /><w <br />� <br />�¢ <br />2Z <br />U <br />�L <br />W <br />r$ <br />T <br />a� <br />N� <br />p <br />wa <br />�6 <br />A <br />� <br />C) <br />J <br />1 <br />> co;i <br />m <br />c� <br />o <br />c0 N <br />co <br />o <br />Cr 0 <br />N <br />m <br />o <br />N <br />~ <br />L0 <br />_ <br />O LL <br />Y <br />m 0 <br />N <br />o0 00 <br />L0 <br />Q CV)p`p <br />T <br />ai <br />w CD CV) <br />� <br />o <br />z <br />E (� yZ`o <br />E • • o :� <br />c <br />c <br />a <br />U _j Q p <br />_° <br />JOB <br />NO: 23-02469 <br />SCALE : AS NOTED <br />SHEET NO. <br />3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.