My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6365 Ten Acre Ct
Zephyrhills
>
Building Department
>
Building Plans
>
6365 Ten Acre Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 2:35:40 PM
Creation date
2/27/2025 11:23:08 AM
Metadata
Fields
Template:
Building Plans
Street #
6365
Location
Ten Acre Ct
Contractor
Lennar Homes
Building Plans - Permit #
5547
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METAL LATH <br />II lk <br />fl it <br />III -a 7�1 s l ll <br />F—,k.. I <br />ti 2"" LONG (314%1" CROWN)I. L <br />16GA,:1-1'.� L't M,4)t``�.. .....11.. t. i l .. <br />STAPLES C& 6" O.C. VERT BETWEEN <br />STUDS (NOTED THUS:—) - OFFSET I I I I 1 1 <br />STAPLES BETWEEN STUDS AS SHOWN _.__ <br />METAL LATH ATTACHMENT DETAIL <br />WALL SHEATHING <br />16GAx1-1 �" LONG i3.4"-1" <br />CROWNI STAPLES ia) 6" <br />O.C. VERT INTO STUDS <br />(NOTED THUS:—) <br />REV. 09.24._21 SCALE: 3.4" = T-Or" <br />`DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 703.7,1 LATH' <br />*"ONLY APPLIES TO LENNAR TPA-IJAX** <br />LATHING ACCESSORIES: <br />ATTACHMENTS SHALL BE OF CORROSION -RESISTANT MATERIALS. <br />WOOD APPLICATION: 16 GA. x 1-1/2" LONG (3/4"-1" CROWN) STAPLES @ 6" O.C. <br />VERTICALLY/HORIZONTALLY INTO FRAMING MEMBERS. <br />MASONRY APPLICATION: CONCRETE STUB NAIL, 3/8" (10 MM) HEAD DIA. MIN. @ <br />6" O.C. VERTICALLY/HORIZONTALLY OR COMPATIBLE ADHESIVES, EXTERIOR <br />GUN -GRADE, CONSTRUCTION ADHESIVE WITH 1" DABS @ 6" O.C. OR IN A <br />SEMI -CONTINUOUS BEAD BETWEEN THE SOLID PLASTER BASE AND THE SOLID <br />PORTION OF THE KEY ATTACHMENT FLANGE. <br />CONTROL JOINTS: INSTALL CONTROL JOINT LATHING ACCESSORIES IN <br />CONFORMANCE WITH C1063. LATH SHALL NOT BE CONTINUOUS THROUGH <br />CONTROL JOINTS, BUT SHALL BE STOPPED AND TIED AT EACH SIDE. <br />ALL ACCESSORIES SHALL BE IN ACCORDANCE WITH THE LATEST ASTM C1063 & <br />ASTM C1861. <br />CORNER OF <br />HOME <br />GARAGE SIDE <br />10'-0" <br />TANK -LESS W/H <br />5'-0" _ <br />STUB -OUT FOR ' <br />GAS METER 0 — <br />O <br />(V <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) -12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY'"* <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS" <br />2" X 4" @ 16" O.C. <br />7'-5" <br />(2) 16d TOENAILS <br />2" X 6" @ 16" O.C. <br />1G'-8" <br />(2) 16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2) 16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'-4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />lo <br />W <br />O <br />ROOF DIAPHRAGM NAILING SCHEDULE <br />RIDGE LINE <br />+ + <br />+ + + + + + + + + <br />+ + + + + + + + + + + + + + <br />+ <br />+ <br />+ + + + + + + + 4 <br />+ + + + + + + + + + + + + + <br />+ + <br />+ + <br />+ + + + + + + + + zo <br />+ + + + + + + -I- + + + + + + <br />+ <br />+ 4f <br />+ + + + + + + + + <br />+ + + + + + + + + + + + + + <br />+ + <br />+ + <br />+ <br />+ <br />+ <br />+ '-0" (TYP.)+ <br />4'-0 <br />+ +4'-0" <br />++++ + +Ll+++ <br />+l <br />+ <br />Zd <br />+ + <br />+++ <br />+++ <br />+ 4+ <br />+ + + + + + + <br />+ <br />+ + + + + + + + + + <br />+ + <br />+ + <br />+ + + + + + + o <br />+ + <br />+ + + + + + + + + <br />\++_+�++ <br />+ <br />+ <br />+ + + + + + + + Cb <br />+ <br />+ + + + + + + + <br />+ + <br />+ + <br />+ + + <br />+ + <br />+ + + + ++ <br />0i <br />`— 15/32" CDX <br />PLYWOOD OR <br />7/16" OSB <br />\—RIDGE LINE <br />140 MPH 003 SECOND GUST EXPOSURE "C" WIND ZONE 140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE <br />8d RING SHANK NAILS @ 6" O.C. & 8d RING SHANK NAILS @ 6" O.C. EDGES & <br />+ + + 4" O.C. @GABLE END WALL OR GABLE TRUSS 8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE + + a <br />0.113 INCH NOMINAL SHANK DIAMETER 0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH 16 TO 20 RINGS PER INCH <br />0.280 INCH FULL ROUND HEAD DIAMETER 0.280 INCH FULL ROUND HEAD DIAMETER <br />2-3/8 INCH NAIL LENGTH 2-3/8 INCH NAIL LENGTH <br />NOTE: FOR 8d RING SHANK NAILS 0.113x 2x 3/8" RING SHANK COIL GUN NAILS MAY BE USED <br />1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. <br />2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. <br />3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING CONSISTS <br />OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" orp <br />5000s 1.8/1.7 <br />nel <br />wood panels <br />Two 3/4" wood panels or 2 x <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2 x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from aboN <br />Filler blocking1/8" gap <br />FILL CELL <br />STD. 90° HOOK BOND BEAM <br />w <br />.... <br />. <br />............ <br />....... <br />....... 11 <br />.................. <br />......... ......... <br />........... ...... <br />Q STD. 90° <br />CONT. #5 <br />CONT. #5 HOOK <br />BAR <br />BAR <br />#5 COAT. <br />.. . <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />SEE PLAN FOR REQ'D <br />PLYWOOD FLOOR <br />COLUMN AND <br />SHEATHING PER PLAN <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br /># OF 2nd FLOOR <br />Solid block all posts from <br />STUDS <br />above to bearing below. <br />SECTION @ INT. BRG. WALL <br />N.T.S. <br />1/8" min. 2" min. <br />}Small gap <br />2" <br />max. � 4 max. <br />Clinch nails <br />when <br />possible 1 <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4) Place joists together and nail from each side with 2 rows of 10d nails 2x4/Plywood/OSB web stiffener 4" max. <br />2x—: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite required when indicated or <br />OF THE JOIST ASA REQUIRED LEAVINGY" GAP TOP sides b 6". - Hangers with side nailing. <br />@ Y -Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />DOUBLE JOIST CONNECTION -Birdsmouthcuts. N.T.S. <br />N.T.S. - Under 2nd floor column w/ loads <br />higher than 15nnih <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />"Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />wall or beam below.* <br />consideration. Check <br />local building <br />�1/16" <br />code for appropriate <br />details in1--or--20 <br />One 10d box <br />areas=20 of high <br />sinker <br />lateral load. <br />nail each side <br />at bearing. <br />Boise Joist Blocking <br />for each lapped joist. <br />Squash block 10d nails SECTION @ INT. BRG. WALL <br />(2x4 minimum) — <br />Bearing wall, Versa -Lam LVL or N.T.S. <br />Glulam Beam <br />"N CKOU MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D (KNOCKOUT EXEMPTS) <br />(see table below) D <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls: - for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below." <br />Joist <br />When joists meet over wall, provide <br />1 3/4" minimum bearing for each. I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel "Non -stacking walls <br />require additional consideration.— <br />6," A 1 Z' ROUND HOLE MAY 6." 6". DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1Y" <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Yz" <br />Round Hole Diameter (in) <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />8.875 <br />10 <br />11 <br />12 <br />13 <br />Rectangular Hole Side (in) <br />2 <br />3 <br />5 <br />6 <br />8 <br />9 <br />10 <br />Any 16" joist <br />Span (ft) <br />8 <br />V-0" <br />1'-1" <br />V-2"' <br />V-2'" <br />V-3'" <br />V-3"' <br />V-7" <br />1'-11" <br />2'-4" <br />2'-9" <br />3'-2" <br />T-7," <br />12 <br />V-0" <br />V-1" <br />1'-2"' <br />V-2" <br />V-3" <br />V-9" <br />2'-4" <br />2'-11" <br />3' 7" <br />4'-2" <br />4'-9"' <br />5'-4 <br />16 <br />V-0"' <br />1'-1° <br />1'-2"' <br />1"-2" <br />1'-7" <br />2"-5" <br />3'-2" <br />3°-10" <br />4'-9"' <br />5'-7" <br />6'-4" <br />T-2"" <br />20 <br />V-0" <br />V-1" <br />V-2"' <br />V-2" <br />2'-0" <br />T-0" <br />4'-0" <br />4'-10" <br />5'-11" <br />6'-11" <br />7'-11" <br />8- <br />24 <br />V_0'" <br />V-1 " <br />V-2'" <br />V-3" <br />2'-5" <br />3'-7'" <br />4'-9"' <br />5'-10"' <br />7'-2" <br />8'-4" <br />9'-6" <br />10'-9" <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1Y" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE 1Yz" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />N.T.S. <br />A <br />Backer block (12" wide min.) <br />Nail with 10-10d nails. <br />\Install tight to -top flange, <br />y \ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gap — <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4%2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if clanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />0.6 X Joist <br />p depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />Web Stiffener Fastener Schedule <br />Joist Bearin Location <br />Series De th End Intermediate <br />BCI5000s <br />9-1/2" <br />2-8d <br />2-8d <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />BC16000s <br />BC16500s <br />9-1/2" <br />2-8d <br />2-8d <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI 60s® <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI90s® <br />" <br />3-16d <br />3-16d <br />14"' <br />-1 <br />5-16d <br />16" <br />6-16d <br />6-16d <br />SIMPSC <br />w/(22)' <br />NAILS T <br />5/8"0 <br />THRU <br />BOLT <br />SIMPSC <br />w/ (22) <br />NAILS T <br />R TRUSS <br />OP PLATE <br />I.0 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />AIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON HETA20 / <br />Plumbing HETAL20 INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />NO <br />FINI$H GRADE <br />SLEEVE THRU STEM <br />SEE PLAN FOR °• a . • , e - • <br />FOUNDATION INFO <br />STEM FOUNDATION <br />-REINF. SEE PLAN <br />ij — b <br />. . ... ... ... <br />�A/C CHASE 4" PVC (2) #5 REBAR <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON HETA20 / HETAL20 <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />LOCATION OF <br />SECOND H10A <br />SIMPSON H10A ° ° (WHEN <br />w/ (18)10d x 1 1/2" ° REQUIRED) <br />NAILS <br />UPLIFT = 1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" v <br />CENTERED @ PIPE <br />PENETRATION <br />a ° <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />° <br />IIf L - <br />SEE FAD. PLN. <br />SIZE & REINF. <br />12" BELOW PIPE VERTICAL THRU FND. <br />GRADE <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION PLUMBING LINE <br />° d <br />d <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION <br />PLUMBING LINE ° a/ <br />1 dva <br />IrE <br />1 a —I-a a .. ' <br />—1 <br />Al <br />2F i <br />OCT 2 8 2022 <br />SEE FND. PLN. <br />SIZE & REINF. <br />Virtual Review Assist, Inc. <br />Plans Review completed and approved <br />for compliance with the 2020 FBC 7th Edition <br />by Debra Anne Klahr PX2300 <br />N <br />.•g er_ -�,..� <br />N <br />LO <br />t•,���— <br />00 <br />o <br />� <br />`. <br />Q <br />k. . <br />uJ <br />0 <br />w <br />0 <br />z <br />Q <br />E <br />(11 > O M o <br />V/ <br />CSA <br />N V -0 D- y a <br />=— M <br />z <br />E •c "c o <br />C: D O E 0o <br />O 11- o N Q <br />Ua"R <br />°—t <br />in V W p.- <br />Q� >` o E M 2 <br />W <br />W <br />W o <br />o w rri W O I- <br />wmo <br />�Q o q��z� <br />MOM_,<O<Q <br />Q <br />Q I- <br /><LLU0J0 <br />F X o <br />aZ O 00 <br />000E gzoxoomzz <br />Ci O O <br />U� 0 Z <br />�(9a0zYeo Z�OOWO�d <br />��WOWHF—gwp2U�Q <br />Q <br />F LL <br />r1 <br />O <br />zCN <br />W <br />CD <br />co <br />Q U) CO I,-- <br />Cl) <br />li ti <br />11") <br />I— 11 (M <br />00 <br />z V � <br />WC) <br />W <br />(O <br />I <br />I <br />I <br />r <br />I <br />O <br />o <br />0 <br />o' <br />0 <br />o <br />0 <br />0 <br />W <br />ClC)o <br />0 <br />0 <br />N <br />I <br />I <br />I <br />I <br />I <br />I <br />Z <br />O <br />N'^W <br />O: <br />N <br />M <br />I <br />I <br />I <br />V/ <br />Lo <br />' <br />♦C <br />CO <br />i <br />zH <br />VJ <br />Qz <br />W <br />0 <br />U <br />00 <br />��� <br />p <br />ow- <br />gas <br />z <br />y 1 <br />= <br />W=Q <br />F- 1— <br />(� <br />I— 2 <br />iV <br />0Y <br />O <br />�O� <br />■ ■ <br />W <br />a- <br /><�D <br />m <br />Q <br />z <br />gWX <br />a- z <br />Z <br />Q <br />� <br />�� <br />U <br />0 <br />� <br />_0 <br />W <br />W <br />z <br />SN1 <br />Q <br />z <br />Z <br />UJ <br />J <br />Il- <br />V/ <br />N <br />>a 0 <br />LAST PLOT DATE <br />■ <br />z 0 <br />STRUCTURAL <br />DETAILS <br />