My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6392 Ten Acre Ct
Zephyrhills
>
Building Department
>
Building Plans
>
6392 Ten Acre Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 6:49:28 PM
Creation date
2/27/2025 11:23:27 AM
Metadata
Fields
Template:
Building Plans
Street #
6392
Location
Ten Acre Ct
Contractor
Lennar Homes
Building Plans - Permit #
5545
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br />) <br />ZONE-2 <br />ATTIC SPACE <br />60 SQ. FT. <br />o <br />Ak <br />0„ 4:12 SLOPE 4:12 SLOPE J <br />I I <br />40 <br />I I <br />I <br />w I <br />i <br />i <br />oCN <br />I <br />CN <br />r <br />I y�A Lh �\Q <br />VENT <br />4'-0" OFF RIDGE VE <br />� I <br />5:12SLOPE <br />1�—— <br />ZONE-3 <br />ATTIC SPACE <br />1071 SQ. FT. <br />H <br />Z <br />w <br />LU 5:12 SLOPE <br />0 <br />w <br />10,11109) <br />ti% <br />I <br />w <br />a <br />O <br />I U) <br />LO <br />LU <br />a <br />5:12 SLOPE �,Q O <br />rn <br />r <br />I <br />- - - - - - - - - - <br />ZONE-1 w <br />1 0- i <br />ATTIC SPACE cn <br />CN <br />97 SQ. FT. <br />ATTIC VENTILATION CALCULATIONS - A <br />ATTIC VENTILATION REQUIRED <br />UPPER VENTILATION PROVIDED <br />Rule <br />1/300 Rule <br />Rid e <br />g <br />Vent Amt <br />Off -Ridge <br />(No UpperOVentilators <br />(Must Provide Upper Ventilators) <br />(Ft) <br />Amt. <br />Re q•) <br />Total <br />Ventilation <br />ATTIC <br />Provided <br />SPACE <br />SQ. FT. <br />Total SQ. <br />SQ. FT. <br />SQ. IN. of <br />by Upper <br />SQ. IN. of <br />of vented <br />IN. of <br />of <br />ventilation to <br />SQ. IN. of <br />SQ. IN. of <br />Ventilators <br />ventilation <br />soffit <br />ventilation <br />vented <br />be provided <br />Ventilation <br />Ventilation <br />(See Elev) <br />required <br />needed <br />required <br />soffit <br />by upper <br />needed <br />ventilators <br />Main <br />0.0 <br />0.0 <br />Floor <br />97 <br />93 <br />13 <br />47 <br />3 <br />23 <br />0.0 <br />(Zone 1) <br />0.0 <br />0.0 <br />Main <br />0.0 <br />0.0 <br />Floor <br />60 <br />58 <br />8 <br />29 <br />2 <br />14 <br />0.0 <br />(Zone 2) <br />0.0 <br />0.0 <br />Upper <br />9.0 <br />1.0 <br />Floor <br />1071 <br />1028 <br />147 <br />514 <br />37 <br />257 <br />273.0 <br />135.0 <br />138.0 <br />(Zone 3) <br />**NOTE — <br />GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS <br />REQUIRED BY FLORIDA BUILDING CODE 7TH EDITION (2020) RESIDENTIAL. <br />ROOF PLAN -A <br />SCALE: Y4"=1'-0" <br />
The URL can be used to link to this page
Your browser does not support the video tag.