My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6417 Ten Acre Ct
Zephyrhills
>
Building Department
>
Building Plans
>
6417 Ten Acre Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2025 10:37:04 AM
Creation date
2/27/2025 11:24:20 AM
Metadata
Fields
Template:
Building Plans
Street #
6417
Location
Ten Acre Ct
Contractor
Lennar Homes
Building Plans - Permit #
5399
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ABBREVIATIONS GENERAL NOTES VERSION CHANGES INDEX OF DRAWINGS <br />ABV -ABOVE MLDG - MOULDING VERSION DESCRIPTION OF CHANGES SHT NO: TITLE <br />AFF - ABOVE FINISH FLOOR MNT - MOUNT OR MOUNTING THE FOLLOWING TECHNICAL CODES SHALL APPLY: 1.0 PLAN REVISIONS CS COVER SHEET <br />AHU - AIR HANDLER UNIT MO - MASONRY OPENING N <br />N <br />A/C - AIR CONDITIONING MUNT - MUNTINS 2020 FLORIDA BUILDING CODE RESIDENTIAL, PLUMBING, MECHANICAL, FUEL GAS, 2.0 PLAN REVISIONS Al FOUNDATION PLAN <br />A2 1ST AND 2ND FLOOR PLAN A N <br />ALUM - ALUMINUM # -NUMBER ENERGY EFFICIENCY, ACCESSIBILITY, AND NFPA 70 NATIONAL ELECTRICAL CODES 2017 <br />AT - ALUMINUM THRESHOLD OC - ON CENTER 3.0 TRUSS CONNECTOR REVISION A3 STAIR DETAILS N <br />A4 FRAMING PLANS A <br />AB - ANCHOR BOLT OGD - OVERHEAD GARAGE DOOR 2020 FBC PLUMBING RESIDENTIAL SECTION 604 4.0 FLORIDA BUILDING CODE 7TH EDITION 2020 UPDATE <br />AVG -AVERAGE OPNG - OPENING 1. TANK TYPE WATER CLOSET VOLUME ( ) A5 EXTERIOR ELEVATIONS &ROOF PLAN �. C1 <br />BFE - BASE FLOOD ELEVATION OPP - OPPOSITE 1A6.1 1ST FLOOR ELECTRICAL PLAN r` - - _ 00 <br />BM -BEAM OPT - OPTIONAL .6 GALLONS 5.0 ADDING K, L & M ELEVATIONS A6.2 2ND FLOOR ELECTRICAL PLANBLK n <br />BLDG - BUILDING OH - OVER HANG <br />SNO STRUCTURAL NOTES ¢ <br />OH CABS- OVERHEAD CABS ' WATER - FLOW RATE. <br />BRD -BOARD SN1 STRUCTURAL NOTES o <br />PNT -PAINT FINISH <br />PUBLIC FACILITIES LAV 0.5 G.P.M. , P z <br />BRG - BEARING PTD - PAINTED PRIVATE FACILITIES LAV 2.2 G.P.M. S3 FOUNDATION DETAILS <br />BTM - BOTTOM PED -PEDESTAL SHOWER HEADS 2.5 G.P.M. DETAILS <br />S4 FRAME WALL BUC -BUILT UP COLUMN PERF -PERFORATED S5 STRUCTURAL DETAILS ' ;` O <br />CAB -CABINET PLT - PLATE 3. ALL PLUMBING WATER LINES S6 WALL SECTION DETAILS <br />0 <br />CD -CONSTRUCTION DOCUMENTS PLYWD -PLYWOOD TO BE CPVC SS RETRO FIT DETAILS <br />CLG - CEILING PKT -POCKET ST STAIR DETAILS w <br />CLG HT - CEILING HEIGHT LB -POUND VTR LOCATIONS ARE APPROXIMATE AND MAY CHANGE DUE TO S11 PRECAST DETAILS <br />CEMT - CEMENTITIOUS PSF - POUNDS PER SQUARE FOOT JOBSITE CONDITIONS =� -� <br />S12 PRECAST DETAILS zz <br />CL - CENTERLINE PSI - POUNDS PER SQUARE PA 1.0 PRODUCT APPROVAL <br />COL -COLUMN PT - PRESSURE TREATED THE FOLLOWING SHALL COMPLY WITH THE 2020 FBC RESIDENTIAL PA 1.1 PRODUCT APPROVAL <br />CONC -CONCRETE PB - PUSH BUTTON CODE PA 1.2 PRODUCT APPROVAL <br />CMU - CONCRETE MASONRY UNIT REF - REFRIGERATOR PA 1.3 PRODUCT APPROVAL <br />CONST - CONSTRUCT OR CONSTRUCTION RECP -RECEPTACLE Q PORCHES AND BALCONIES <br />CONT - CONTINUOUS OR CONTINUES REINF - REINFORCING CHAP. 3 PA 1.4 PRODUCT APPROVAL > 0 u <br />SH 1.0 HURRICANE SHUTTERS 0 M N �; CTR -CENTER READ -REQUIRED tom., <br />CJ - CONTROL JOINT R/A - RETURN AIR 0 HANDRAILS - CHAP. 3 SH 1.1 HURRICANE SHUTTERS a-- •e= j ci 2 <br />DP - DEEP OR DEPTH RO - ROUGH OPENING SH 1.2 HURRICANE SHUTTERS to V -0-0 0 <br />DTL - DETAIL RS ROUGH SAWN E r <br />DIA - DIAMETER 8 <br />SC -SOLID CORE GUARDRAILS - CHAP. 3 SH 1.3 HURRICANE SHUTTERS � <br />DIM - DIMENSION SCP -SCUPPER <br />DISCON -DISCONNECT \SOH 114 HURRICANE SHUTTERS .N U Qg Q <br />SCRN -SCREEN STAIRS - CHAP. 3 SH 1.5 HURRICANE SHUTTERS Z U p °' <br />DR -DOOR DISHWASHER SIM - SIMILAR CHIMNEY & FIREPLACE L o � N _ <br />0 WATERPROOFING DETAILS <br />SHLVS -SHELVES Q �I <br />DBL -DOUBLE f- a <br />DWG - DRAWING S/R - SHELF & ROD CHAP. 10 W <br />SH - SINGLE HUNG WINDOW y <br />A - ELECTRICAL SGD - SLIDING GLASS DOOR ❑ EGRESS WINDOWS <br />Ed <br />ELEV -ELEVATOR SPECS - SPECIFICATIONS CHAP. 3 <br />SQ FT - SQUARE FEET <br />EQ -EQUAL SQ IN - SQUARE INCH 5. ALL OPENINGS SHALL COMPLY WITH 2O20 FBC RESIDENTIAL WIND LOADS AS STATED <br />EQUP - EQUIPMENT STD -STANDARD BELOW. ATTACHMENTS OF WINDOWS, DOORS, SLIDING GLASS DOORS AND O.H. <br />EXP JT - EXPANSION JOINT STL -STEEL GARAGE DOORS ARE TO DELEGATED THE MANUFACTURER OF THESE ITEMS. THE <br />EXT - EXTERIOR STRUCT -STRUCTURAL MANUFACTURER OF THESE ITEMS SHALL SUBMIT ATTACHMENTS FOR SITE <br />FIN FLR - FINISHED FLOOR TEMP -TEMPERED INSTALLATION. <br />FIN - FIN THK - THICK OR THICKNESS <br />EW - EACH WAY TB - TOWEL BAR SEE ATTACHED SPECIFICATION SHEETS FOR MANUFACTURERS DESIGN CRITERIA <br />FG - FIXED GLASS TOC - TOP OF CONCRETE AND INSTALLATION METHODS FOR WINDOWS, DOORS, SLIDING GLASS DOORS, <br />FD - FLOOR DRAIN TOM - TOP OF MASONRY OVERHEAD GARAGE DOORS, AND ROOFING. <br />FE - FIRE EXTINGUISHER TOP - TOP OF PLATE <br />FLR -FLOOR TP - TOILET PAPER HOLDER <br />FLOUR - FLUORESCENT TYP - TYPICAL 6. ALL DOORS INTERIOR & EXTERIOR ARE 6'-8" UNLESS OTHERWISE NOTED ALL <br />FTG - FOOTING UNO - UNLESS NOTED OTHERWISE SHOWER ENCLOSURES TO BE TEMPERED GLASS <br />FR DR - FRENCH DOOR VAC -VACUUM W '� rw- i cc z f <br />GALV -GALVANIZED VAL - VALANCE 7. ALL WINDOWS WITHIN 24" OF DOORS (INTERIOR & EXTERIOR) AND WITHIN 18" OF FLR (� W W o m ¢ o ¢ ¢ � y o ° _o <br />TO BE TEMPERED GLASS. (SECTION R308) Q o z w LL_ z M 0 o��¢ <br />GA -GAUGE VERT -VERTICAL Q U a x m�� o m o o � <br />GB - GRAB BAR VIF - VERIFY IN FIELD �- I- o W � o z o W ° � 0° z : � p <br />GFI / GFCI- GROUND FAULT CIRCUIT INTERRUPTOR VTR - VENT THROUGH ROOF O O �' o a z o z ¢ o a <br />GLS - GLASS V - VOLT (n Z ¢ ~ w � � , g Y <br />DIMENSIONING: ¢¢ o w Z w z o w c� o a <br />GWB - GYPSUM WALL BOARD WC - WATER CLOSET A. DIMENSIONS INDICATED ARE TO: g ¢ cr m o 25 � ¢ <br />GYPBRD -GYPSUM BOARD WH -WATER HEATER <br />HD - HEAD WL - WIND LOAD A.I. CMU WALL: OUTSIDE FACE OF WALL <br />HVAC - HEATING, VENTILATING, AIR CONDITIONING WP - WEATHERPROOF A.2. INTERIOR FRAMED WALLS: PLAN WEST (OR PLAN NORTH) FROM FACE OF <br />HT - HEIGHT WWM - WELDED WIRE MESH CORE -STUD <br />HB - HOSE BIB W - WIDE OR WIDTH A.2.1. DIMENSIONS ARE NOT FROM ELEMENTS ATTACHED TO CORE STUD - I.E. <br />HC - HANDICAP WDW - WINDOW FURRING\ <br />INSUL - INSULATION W/ - WITH A.3. EXTERIOR FRAMED WALLS: TO OUTSIDE FACE OF STRUCTURAL CORE -STUD Z N <br />INT - INTERIOR WD -WOOD W <br />A.4. WINDOW OPENINGS: <br />LVL - LAMINATED VENEER LUMBER A.4.1. CMU WALLS: TO LEFT SIDE OF ROUGH OPENING ~ <br />LT - LAUNDRY TUB A.4.2. EXTERIOR FRAMED WALLS: TO CENTER OF OPENING (1) <br />LGT - LIGHT <br />MAX - MAXIMUM A.5. DOOR OPENINGS: p <br />MATL - MATERIAL A.5.1. CMU WALLS: TO LEFT SIDE OF ROUGH OPENING `M `O <br />MFR -MANUFACTURER A.5.2. EXTERIOR FRAMED WALLS: TO CENTER OF OPENING <br />MECH - MECHANICAL A.5.3. INTERIOR FRAMED WALLS: ADJACENT TO SIDE WALL: 5" RETURN MEASURED -t <br />MTL - METAL FROM THE FINISH FACE OF ADJACENT WALL TO INTERIOR FACE OF DOOR W <br />MC - MEDICINE CABINET FRAME Q Q <br />MIN -MINIMUM A.5.4. INTERIOR FRAMED WALLS: AWAY FROM SIDE WALLS: DIMENSIONED TO CENTER <br />OF DOOR <br />A.6. SPECIAL AND CODE REQUIRED CLEARANCES - AS INDICATED ON PLANS OR FINISH Q >- Q 00 <br />SURFACE TO FINISH SURFACE Z U F- <br />SYM BOL LEGEND. A.6.1. EXAMPLE: 3'-0" CLEAR INSIDE FINISH FOR ADA TRANSFER SHOWER Z <br />B. ALIGNMENT OF WALLS AND FINISHES AS SCHEDULED SHALL BE STRAIGHT, TRUE AND WuJ <br />❑A = STAIR CALL OUT HEIGHT OF SHEET NUMBER PLUMB. _j �O <br />co STEP DOWN C. THE PRIORITY FOR PROJECT DIMENSIONS SHALL BE IN THE FOLLOWING ORDER: (p <br />l�� l INT ELEV NUMBER C.1. CODE MINIMUM - MAXIMUM DIMENSIONS AND CLEARANCES W <br />FOOTING CALL OUT - STEP DOWN ARROW SHOWS C.2. LOAD BEARING CONCRETE MASONRY UNIT WALLS <br />SEE FOOTING CALLOUT DIRECTION OF VIEW C.3. FRAMED WALLS EXTERIOR <br />SCHEDULE <br />ARROW SHOWS INTERIOR ELEVATION CA. FRAMED WALLS INTERIOR <br />= KEYNOTE CALL OUT DIRECTION OF VIEW MARKER C.5. DOORS AND WINDOWS <br />1 D. FLOOR ELEVATIONS ARE INDICATED TO THE FACE OF THE STRUCTURAL SLAB - <br />A9 ELEV NUMBER ARROW SHOWS UNLESS OTHERWISE NOTED <br />PRE -CAST LINTEL CALL SHEET NUMBER DIRECTION OF CUT E. VERTICAL DIMENSIONS ARE INDICATED FROM THE FLOOR ELEVATION TO THE FACE <br />CD= OUT - SEE LENTEL EXTERIOR 1 OF MATERIAL AT THE DIMENSION POINT - UNLESS OTHERWISE NOTED <br />SCHEDULE ELEVATION MARKER Al SECTION NUMBER F. CEILING HEIGHTS ARE INDICATED FROM THE FLOOR ELEVATION TO FACE OF THE <br />< i <br />1 ELEV NUMBER SHEET NUMBER STRUCTURAL MATERIAL ABOVE AS SCHEDULED <br />G. DIMENSIONS SHOWN ON THE DRAWINGS SHALL INDICATE THE REQUIRED SIZE, <br />LEDGER CALL OUT - SEE <br />LEDGER SCHEDULE 4 A15 2 SHEET NUMBER CLEARANCE AND DIMENSIONAL RELATIONSHIP BETWEEN PROJECT SYSTEMS AND <br />LOCATION OF CUT COMPONENTS - DIMENSIONS SHALL NOT BE DETERMINED BY SCALING THE <br />E---ARROW SHOWS DRAWINGS. <br />3 DIRECTION OF VIEW co <br />MULTI VIEW INTERIOR SECTION <br />ELEVATION MARKER MARKER O O O o- N <br />N o0000 <br />0 6 2022 ►� � M .�- <br />OCT O N o <br />GAD O) O N 0 I 7 <br />O O - O O 1 <br />Z <br />0 <br />\I�AN a' ! <br />Virtual Review Assist, Inc. <br />W N 'i 4 6 1 t <br />Plans Review completed and approved <br />K LO qq <br />for compliance with the 2020 FBC 7th Edition <br />by Debra Anne Klahr PX2300 M r� Z� <br />w vJ ¢Z <br />0 55 <br />w <br />-LE N NARM Lo�+-+ W 0 0 0 <br />_V VU— <br />0 <br />0W5 <br />Z a -a <br />LENNAR TAMPA DIVISION <br />LO <br />�n = Lux <br />4600 W CYPRESS ST, SUITE 200 r`' z <br />NOTICE TO BUILDER & ALL SUBCONTRACTORS N zoo <br />TAMPA, F L 33607 IT IS THE INTENT OF DESIGN PROFESSIONAL LISTED IN THE TITLE r Q U g W LL <br />Z �z <br />813. 574. 5700 BLOCK THAT THESE DOCUMENTS ARE ACCURATE, PROVIDING =z <br />LICENSED PROFESSIONALS CLEAR INFORMATION. EVERY ATTEMPT 2 Z z <br />HAS BEEN MADE TO PREVENT ERRORS: THE BUILDER AND ALL O <br />SUBCONTRACTORS ARE REQUIRED TO REVIEW ALL THE 0 CL <br />INFORMATION CONTAINED IN THESE DOCUMENTS, PRIOR TO THE <br />COMMENCEMENT OF ANY WORK. THE DESIGN PROFESSIONAL ARE MM <br />NOT RESPONSIBLE FOR ANY PLAN ERRORS, OMISSIONS,OR W <br />MISINTERPRETATIONS UNDETECTED AND NOT REPORTED TO THE ¢ <br />DESIGN PROFESSIONAL PRIOR TO CONSTRUCTION. ALL z W C S CONSTRUCTION MUST BE IN ACCORDANCE TO THE INFORMATION <br />FOUND IN THESE DOCUMENTS. ANY QUESTIONS REGARDING THE <br />co <br />INFORMATION FOUND IN THESE PLANS SHOULD BE DIRECTED TO THE O <br />DESIGN PROFESSIONAL LISTED IN THIS TITLE PAGE. NO BACK 0 LAST PLOT DATE2551 " <br />CHARGES WILL BE CONSIDERED FOR REIMBURSEMENT BY THE �-+ July 21, 2022 <br />DESIGN PROFESSIONAL WITHOUT ADVANCED NOTIFICATION AND O <br />APPROVAL BY THE DESIGN PROFESSIONAL. <br />COVER SHEET <br />
The URL can be used to link to this page
Your browser does not support the video tag.