My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6417 Ten Acre Ct
Zephyrhills
>
Building Department
>
Building Plans
>
6417 Ten Acre Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2025 10:37:04 AM
Creation date
2/27/2025 11:24:20 AM
Metadata
Fields
Template:
Building Plans
Street #
6417
Location
Ten Acre Ct
Contractor
Lennar Homes
Building Plans - Permit #
5399
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SECOND FLOOR ELECTRICAL PLAN (ALL ELEVATIONS' <br />1 /4„ = 1'-011 <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />OCT o 6 2022 <br />Virtual Review Assist. Inc. <br />Plans Review completed and appro d <br />for compliance with the 2020 FBC 7th Edition <br />by Debra Anne Klahr PX2300 <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />is <br />SWITCH Uj <br />° <br />4 1/2" <br />DOOR JAMB DUPLEX, <br />OUTLET co <br />TRIM o <br />0 <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />p Z <br />kS 1__' <br />SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />11 OV DUPLEX OUTLET AT 12" <br />Q� 11 OV DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />11 OV DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />11 OV DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 11 OV DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />11 OV QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />11 OV DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />�} TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />-ee SWITCH AT 36" <br />3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />-0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />--o DIMMER SWITCH AT 36" <br />-0 PUSH-BUTTON DOORBELL <br />-- CLG MNT LT FIXTURE <br />CLG MNT PREWIRE - FIXTURE BY OWNER <br />+ SURFACE MNT FIXTURE <br />- <br />WALL MNT FIXTURE <br />NOTE: <br />40W A 6" ROUND OPALEX - <br />ALTERNATE <br />TUB/SHOWER <br />CANS MAY BE <br />4 <br />5OW PAR30 NFL 6" WHITE BAFFLE <br />USEDIF <br />APPROVED BY <br />6� <br />5OW MR16 4" LOW VOLTAGE <br />OWNER <br />SOW PAR20 NFL 4" MINI ROUND RECESS <br />�0 <br />50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />} CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />cs SMOKE DETECTOR <br />Q SMOKE DETECTOR <br />-U-18- UNDER CABINET 18" <br />cS-18n SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= <br />SINGLE 24" FLUOR STRIP <br />=D-24= <br />DOUBLE 24" FLUOR STRIP <br />— U-36 = <br />UNDER CABINET 36" <br />— S-36 — <br />SINGLE 36" FLUOR STRIP <br />— D-36 — <br />DOUBLE 36" FLUOR STRIP <br />— S-48 <br />SINGLE 48" FLUOR STRIP <br />— D-48 <br />DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />® 48"CLG MNT WRAPPED FLUOR LIGHT <br />97r24-;9 24" VANITY LIGHTING <br />R;-m 36 :FR 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />Q EXHAUST FAN <br />0 & DOUBLE FLOOD LIGHT W/ COVERS AND <br />CT 15OW PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />GM CHIMES (DELETE W/ INTERCOM) <br />MASTER STATION <br />Ii.,1 ELEC PANEL <br />VACUM OUTLET AT 12" <br />CEILING RETURN AIR <br />iM A/C REGISTER <br />® THERMOSTAT <br />ED SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />/I\ <br />4) E <br />'0 M O <br />W <br />i <br />'Q N di <br />r � `O 2 <br />Q� <br />S <br />�- O"� 9Q <br />s <br />0 <br />._ <br />N <br />a) <br />�� <br />V w n N C <br />o E C <br />EC�-a °c N <br />a <br />V, <br />LI.I <br />u <br />w <br />�w w w M <br />LU O Q JaZ <br />O�W0LL VOO O <br />Q a <br />U <br />icy ZLLLL°z�°0F <br />F- <br />0 <br />Z <br />C�WwOZOWOCr <br />cn a rnww <br />ap< W zo- <br />Z��U <br />XQ <br />iYOL%a. <br />0 <br />U) <br />LL <br />OQ n <br />oQZ� <br />LL <br />a LL <br />O <br />Z <br />W <br />OF- <br />0 <br />p M <br />QU)Mt) <br />�LL <br />� <br />I-�<Lq <br />M_ <br />00 <br />ZUF- <br />Z <br />W <br />Wo <br />J 0 <br />d' <br />CM <br />9 <br />i <br />i <br />CDN <br />N <br />N <br />N <br />N <br />N <br />o0000 <br />N <br />N <br />N <br />N <br />N <br />r <br />rn <br />00 <br />0 <br />C) <br />0 <br />iCD <br />a <br />� <br />cn <br />a <br />Co <br />�- <br />a' <br />o <br />z <br />O <br />NLo <br />W <br />> <br />o <br />r- <br />0 <br />c�i <br />0 <br />ri <br />0 <br />v <br />C)I <br />ui <br />I <br />I <br />I <br />LO <br />V , <br />NT <br />z <br />W <br />U) <br />z <br />w <br />CDo <br />W <br />z <br />6- <br />O <br />V <br />wO_O Fn <br />U U <br />Lo <br />-0 <br />O <br />OF_o <br />-0Z <br />Q <br />�--I <br />a~Ca <br />Q <br />3: <br />wLn <br />In <br />mites <br />F- �_ 2 <br />(V <br />O <br />zoo <br />. . <br />W <br /><�� <br />N <br />Q <br />Z <br />r0, <br />U <br />ZWO <br />az <br />Z <br />�z <br />F � <br />pU <br />_o <br />W <br />z <br />z <br />W <br />J <br />ce) <br />0 <br />C) <br />LAST PLOT DATE <br />. . <br />July 21, 2022 <br />z <br />0 <br />J <br />2ND FLOOR <br />ELECTRICAL PLAN <br />
The URL can be used to link to this page
Your browser does not support the video tag.